Ahmad A. Almazloum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmad A. Almazloum has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- José Wilson Magalhães Bassani
Brazilian Laboratory for the Study of Cell Calcium (LabNECC), Center for Biomedical Engineering, Universidade Estadual de Campinas, Campinas, Brazil
2 shared publications - Abdel-Razzak Al-Hinnawi
Department of Radiographic Technology, Faculty of Allied Medical Sciences, Isra University, Amman 11622, Jordan
1 shared publication - Monica Alonso Cotta
Universidade Estadual de Campinas
1 shared publication - Paolo Visconti
Department of Innovation Engineering, University of Salento, 73100 Lecce, Italy
1 shared publication - Paulo Guimarães Gandra
Department of Biochemistry and Tissue Biology, Institute of Biology, UNICAMP, Campinas, SP, Brazil; National Laboratory for Study of Cell Calcium (LabNECC), Center for Biomedical Engineering (CEB), UNICAMP, Campinas, SP, Brazil
1 shared publication - Roberto De Fazio
Department of Innovation Engineering, University of Salento, 73100 Lecce, Italy
1 shared publication
Latest Publications
- 7 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 144 (1) , 104393
Electrical pulse generator for electroporation induction in myocytes: Compared effects on skeletal and cardiac cells
High-intensity, external electric fields (HIEF) have been used in research and therapy for abnormal generation/propagation of the cardiac electrical activity (e.g., defibrillation), and for promoting access of membrane-impermeant molecules into the cytosol through electropores. This report proposes the architecture of a pulse generator designed for both pacing and electroporation induction in isolated myocytes for the study of HIEF impact and membrane repair mechanisms. The instrument was used for quantitative characterization and comparison of the sensitivity of myocytes isolated from skeletal and cardiac muscle to HIEF-induced lethal damage, which requires severe electroporation. The pulse generator was able to produce lethal injury in both cell types, even though skeletal myocytes required fields ∼50 % greater than cardiomyocytes, thus underscoring the suitability of the proposed instrument for electroporation induction in muscle cells. It is thus likely that the reported greater myocardial vulnerability to severe electrical injury, compared to other tissues, is due to the greater cardiomyocyte sensitivity to HIEF.
- 7 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 144 (1) , 104393
Electrical pulse generator for electroporation induction in myocytes: Compared effects on skeletal and cardiac cells
High-intensity, external electric fields (HIEF) have been used in research and therapy for abnormal generation/propagation of the cardiac electrical activity (e.g., defibrillation), and for promoting access of membrane-impermeant molecules into the cytosol through electropores. This report proposes the architecture of a pulse generator designed for both pacing and electroporation induction in isolated myocytes for the study of HIEF impact and membrane repair mechanisms. The instrument was used for quantitative characterization and comparison of the sensitivity of myocytes isolated from skeletal and cardiac muscle to HIEF-induced lethal damage, which requires severe electroporation. The pulse generator was able to produce lethal injury in both cell types, even though skeletal myocytes required fields ∼50 % greater than cardiomyocytes, thus underscoring the suitability of the proposed instrument for electroporation induction in muscle cells. It is thus likely that the reported greater myocardial vulnerability to severe electrical injury, compared to other tissues, is due to the greater cardiomyocyte sensitivity to HIEF.
- 17 December 2023
- Published by Springer Nature
- p. 176-187
Evaluating the Mechanical Properties of Isolated Rat Cardiomyocytes Sarcolemma Using Atomic Force Microscopy
- 17 December 2023
- Published by Springer Nature
- p. 176-187
Evaluating the Mechanical Properties of Isolated Rat Cardiomyocytes Sarcolemma Using Atomic Force Microscopy
- Open Access
Assessment of Multi-Layer Perceptron Neural Network for Pulmonary Function Test’s Diagnosis Using ATS and ERS Respiratory Standard Parameters
The aim of the research work is to investigate the operability of the entire 23 pulmonary function parameters, which are stipulated by the American Thoracic Society (ATS) and the European Respiratory Society (ERS), to design a medical decision support system capable of classifying the pulmonary function tests into normal, obstructive, restrictive, or mixed cases. The 23 respiratory parameters specified by the ATS and the ERS guidelines, obtained from the Pulmonary Function Test (PFT) device, were employed as input features to a Multi-Layer Perceptron (MLP) neural network. Thirteen possible MLP Back Propagation (BP) algorithms were assessed. Three different categories of respiratory diseases were evaluated, namely obstructive, restrictive, and mixed conditions. The framework was applied on 201 PFT examinations: 103 normal and 98 abnormal cases. The PFT decision support system’s outcomes were compared with both the clinical truth (physician decision) and the PFT built-in diagnostic software. It yielded 92–99% and 87–92% accuracies on the training and the test sets, respectively. An 88–94% area under the receiver operating characteristic curve (ROC) was recorded on the test set. The system exceeded the performance of the PFT machine by 9%. All 23 ATS\ERS standard PFT parameters can be used as inputs to design a PFT decision support system, yielding a favorable performance compared with the literature and the PFT machine’s diagnosis program.
Open AccessAssessment of Multi-Layer Perceptron Neural Network for Pulmonary Function Test’s Diagnosis Using ATS and ERS Respiratory Standard Parameters
The aim of the research work is to investigate the operability of the entire 23 pulmonary function parameters, which are stipulated by the American Thoracic Society (ATS) and the European Respiratory Society (ERS), to design a medical decision support system capable of classifying the pulmonary function tests into normal, obstructive, restrictive, or mixed cases. The 23 respiratory parameters specified by the ATS and the ERS guidelines, obtained from the Pulmonary Function Test (PFT) device, were employed as input features to a Multi-Layer Perceptron (MLP) neural network. Thirteen possible MLP Back Propagation (BP) algorithms were assessed. Three different categories of respiratory diseases were evaluated, namely obstructive, restrictive, and mixed conditions. The framework was applied on 201 PFT examinations: 103 normal and 98 abnormal cases. The PFT decision support system’s outcomes were compared with both the clinical truth (physician decision) and the PFT built-in diagnostic software. It yielded 92–99% and 87–92% accuracies on the training and the test sets, respectively. An 88–94% area under the receiver operating characteristic curve (ROC) was recorded on the test set. The system exceeded the performance of the PFT machine by 9%. All 23 ATS\ERS standard PFT parameters can be used as inputs to design a PFT decision support system, yielding a favorable performance compared with the literature and the PFT machine’s diagnosis program.