Zhongyun Tian
Research Subjects
Zhongyun Tian has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Yiqiang Jiang
6 shared publicationsWenke Zheng
5 shared publicationsJiwei Guo
4 shared publicationsYaolong Wang
4 shared publicationsXiaoguang Mi
2 shared publicationsChangfei Tian
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China
1 shared publication
Latest Publications
- Open Access
A Study on the Thermal Management Performance of Server-Oriented Memory Liquid Cooling Solutions
The rapid increase in memory power density has made memory thermal management a critical challenge in high-density servers, where extremely limited DIMM spacing significantly reduces the effectiveness of air cooling. Compared with CPUs and GPUs, memory-level liquid cooling has received less systematic study, particularly regarding the influence of cold plate structural design on thermal and hydraulic performance under realistic server conditions. In this paper, three engineering-feasible memory liquid cooling solutions (water-flowing cold plate, clamp-type cold plate and heat-pipe-based cold plate) are experimentally compared on a high-density server system. Experiments are conducted at coolant inlet temperatures of 37–50 °C with a fixed flow rate of 0.8–1.5 L/min. Memory, CPU, and voltage regulator temperatures, as well as system pressure drop, are measured. Results show that memory temperature increases with coolant inlet temperature for all configurations, while their relative performance remains unchanged. Memory temperatures range from 62.04 to 71.13 °C, 57.65 to 66.98 °C, and 66.22 to 76.07 °C, with corresponding pressure drops of 24.19–26.69 kPa, 32.73–35.98 kPa, and 27.00–29.96 kPa. These results provide insight into the role of coolant distribution and flow-path topology in memory thermal performance.
Open AccessA Study on the Thermal Management Performance of Server-Oriented Memory Liquid Cooling Solutions
The rapid increase in memory power density has made memory thermal management a critical challenge in high-density servers, where extremely limited DIMM spacing significantly reduces the effectiveness of air cooling. Compared with CPUs and GPUs, memory-level liquid cooling has received less systematic study, particularly regarding the influence of cold plate structural design on thermal and hydraulic performance under realistic server conditions. In this paper, three engineering-feasible memory liquid cooling solutions (water-flowing cold plate, clamp-type cold plate and heat-pipe-based cold plate) are experimentally compared on a high-density server system. Experiments are conducted at coolant inlet temperatures of 37–50 °C with a fixed flow rate of 0.8–1.5 L/min. Memory, CPU, and voltage regulator temperatures, as well as system pressure drop, are measured. Results show that memory temperature increases with coolant inlet temperature for all configurations, while their relative performance remains unchanged. Memory temperatures range from 62.04 to 71.13 °C, 57.65 to 66.98 °C, and 66.22 to 76.07 °C, with corresponding pressure drops of 24.19–26.69 kPa, 32.73–35.98 kPa, and 27.00–29.96 kPa. These results provide insight into the role of coolant distribution and flow-path topology in memory thermal performance.
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Intraday Optimization of Photovoltaic and Energy Storage‐Driven HVAC Systems Based on an Equivalent RC Model
Efficient management of building energy systems, particularly those integrating photovoltaic (PV) generation and energy storage systems (ESSs), is challenging due to the fluctuating nature of energy demand, supply, and electricity prices. Traditional optimization methods, such as day‐ahead or intraday scheduling, often fail to fully meet the operational needs of energy systems, leading to wasted renewable energy, unmet load demand, and suboptimal cost‐efficiency. This study addresses these gaps by proposing an integrated optimization strategy that combines day‐ahead predictive scheduling with intraday adjustments, leveraging a second‐order equivalent resistance–capacitance (RC) model to manage ESS charging and discharging. The strategy optimizes energy storage utilization and minimizes reliance on grid power by dynamically adjusting charging and discharging based on intraday conditions and price fluctuations. Tested on an office building, the proposed strategy reduced operating costs by 29.66% compared to day‐ahead scheduling alone and by 15.48% compared to intraday optimization while eliminating unmet load demand and minimizing wasted PV generation. Grid reliance was also reduced by 33.33%. These findings underscore the critical role of coordinated charging and discharging strategies in improving energy management efficiency and reducing costs in PV–ESS integrated systems.
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Open AccessIntraday Optimization of Photovoltaic and Energy Storage‐Driven HVAC Systems Based on an Equivalent RC Model
Efficient management of building energy systems, particularly those integrating photovoltaic (PV) generation and energy storage systems (ESSs), is challenging due to the fluctuating nature of energy demand, supply, and electricity prices. Traditional optimization methods, such as day‐ahead or intraday scheduling, often fail to fully meet the operational needs of energy systems, leading to wasted renewable energy, unmet load demand, and suboptimal cost‐efficiency. This study addresses these gaps by proposing an integrated optimization strategy that combines day‐ahead predictive scheduling with intraday adjustments, leveraging a second‐order equivalent resistance–capacitance (RC) model to manage ESS charging and discharging. The strategy optimizes energy storage utilization and minimizes reliance on grid power by dynamically adjusting charging and discharging based on intraday conditions and price fluctuations. Tested on an office building, the proposed strategy reduced operating costs by 29.66% compared to day‐ahead scheduling alone and by 15.48% compared to intraday optimization while eliminating unmet load demand and minimizing wasted PV generation. Grid reliance was also reduced by 33.33%. These findings underscore the critical role of coordinated charging and discharging strategies in improving energy management efficiency and reducing costs in PV–ESS integrated systems.
- 19 November 2024
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 56
Research on prediction model of two-phase flow and friction pressure drop in spiral pipe based on flow regimes
- 19 November 2024
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 56
Research on prediction model of two-phase flow and friction pressure drop in spiral pipe based on flow regimes
- 12 June 2024
- Published by Elsevier in Experimental Thermal and Fluid Science
- Vol. 158, 111245
Experimental analysis on the flow patterns and conversion mechanisms of condensing flow with non-azeotropic mixtures in spiral tube
- 12 June 2024
- Published by Elsevier in Experimental Thermal and Fluid Science
- Vol. 158, 111245
Experimental analysis on the flow patterns and conversion mechanisms of condensing flow with non-azeotropic mixtures in spiral tube
- Open Access
Analysis of Flow and Pressure Drop on Tube Side of Spiral Tube Heat Exchanger under Sloshing Conditions
The utilization of the spiral tube heat exchanger (SHE) has become increasingly prevalent in large-scale liquefaction processes. However, the flow pattern and frictional pressure drop of two-phase flow in the spiral tube have been scarcely studied, particularly under offshore sloshing conditions. An experimental system had been developed to explore the flow pattern and frictional pressure drop characteristics of mixed hydrocarbon fluid in a spiral tube. Moreover, these have been developed in order to examine the effects of sloshing style (roll, pitch, heave), sloshing period (5–15 s), sloshing amplitude (5–15° or 50–150 mm), mass flux (200–800 kg/(m2·s)), vapor quality (0–1), and saturation pressure (2–4 MPa) on the frictional pressure drop of methane/ethane mixture in the spiral tube. The results indicated that sloshing conditions reduce the frictional pressure drop, thereby enhancing fluid flow. A correlation was established to predict the sloshing factor of frictional pressure drop, and the MARD under verification conditions was 6.04%. Furthermore, three flow pattern boundaries were proposed based on We* as an indicator.
Open AccessAnalysis of Flow and Pressure Drop on Tube Side of Spiral Tube Heat Exchanger under Sloshing Conditions
The utilization of the spiral tube heat exchanger (SHE) has become increasingly prevalent in large-scale liquefaction processes. However, the flow pattern and frictional pressure drop of two-phase flow in the spiral tube have been scarcely studied, particularly under offshore sloshing conditions. An experimental system had been developed to explore the flow pattern and frictional pressure drop characteristics of mixed hydrocarbon fluid in a spiral tube. Moreover, these have been developed in order to examine the effects of sloshing style (roll, pitch, heave), sloshing period (5–15 s), sloshing amplitude (5–15° or 50–150 mm), mass flux (200–800 kg/(m2·s)), vapor quality (0–1), and saturation pressure (2–4 MPa) on the frictional pressure drop of methane/ethane mixture in the spiral tube. The results indicated that sloshing conditions reduce the frictional pressure drop, thereby enhancing fluid flow. A correlation was established to predict the sloshing factor of frictional pressure drop, and the MARD under verification conditions was 6.04%. Furthermore, three flow pattern boundaries were proposed based on We* as an indicator.
- 1 January 2021
- Published by Elsevier in International Journal of Refrigeration
- Vol. 121, 206-215
Research on waste heat recovery from gas engine for auxiliary heating: An emerging operation strategy to gas engine-driven heat pump
- 1 January 2021
- Published by Elsevier in International Journal of Refrigeration
- Vol. 121, 206-215
Research on waste heat recovery from gas engine for auxiliary heating: An emerging operation strategy to gas engine-driven heat pump