AEAhmed F. Elmaria

Ahmed F. Elmaria

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed F. Elmaria has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic accuracy of quantitative anterior segment optical coherence tomography parameters for identifying occludable angles: a cross-sectional study

    by Mona M. Amer, Tarek M. Eid, Ahmed M. Ghoneim, Ahmed F. Elmaria

    Objective: To assess the diagnostic accuracy of quantitative swept-source anterior segment optical coherence tomography (AS-OCT) parameters in identifying occludable anterior chamber angles, using clinical gonioscopy as the reference standard. Patients and methods: This prospective, cross-sectional diagnostic accuracy study enrolled 80 eyes from 80 participants at the Ophthalmology Department of Tanta University between January 2018 and December 2019. Before image quality-based exclusions, eyes were clinically divided into four groups ( n =20 each): control, primary open-angle glaucoma (POAG), primary angle closure without synechiae (PAC−), and with synechiae (PAC+). All participants underwent standardized gonioscopy and AS-OCT imaging under dim illumination. Quantitative AS-OCT parameters—angle width (AW), angle opening distances (AOD) at 500 μm and 750 μm from the scleral spur (SS) (AOD500, AOD750), trabecular iris contact length (TICL), and peripheral iris thickness (IT500, IT750)—were measured in superior and inferior quadrants. Correlations with Shaffer gonioscopic grading were evaluated. Diagnostic accuracy was assessed using the area under the receiver operating characteristic curve (AUC). Results: Seventy-four eyes were included in the final analysis after excluding six eyes due to unreliable SS identification. Group sizes were: control ( n =19), POAG ( n =19), PAC− ( n =18), PAC+ ( n =18). AW and AOD values decreased progressively, while TICL increased from control/POAG to PAC− and PAC+ groups ( P < 0.001). IT500 showed modest differences ( P < 0.05); IT750 was not significant. AW, AOD500, and AOD750 correlated strongly with Shaffer grading ( P =0.876–0.915, P < 0.001), while TICL showed a strong inverse correlation ( P =–0.833 to −0.846, P < 0.001). Receiver operating characteristic analysis showed excellent diagnostic performance (AUC 0.919–0.975 superior; 0.936–0.972 inferior). Conclusion: Quantitative AS-OCT parameters offer high diagnostic accuracy and correlate well with gonioscopic grading for detecting occludable angles. Limitations include the cross-sectional design and manual identification of the SS.

  • Open Access

    Machine learning based diagnosis and staging of primary open angle glaucoma using lamina cribrosa parameters

    by Ahmed A. Elbasty, Tarek R. Hussein, Ahmed F. Elmaria

    Purpose: The aim of this study was to build and internally validate a machine learning (ML) model that can discriminate between normal individuals and patients with different glaucoma stages using the lamina cribrosa (LC) structural parameters. Patients and methods: This retrospective analysis used a dataset of 92 eyes (52 glaucomatous eyes of 28 primary open angle glaucoma patients and 40 normal eyes of 20 age-matched normal participants). Five LC parameters, specifically prelaminar neural tissue (PLNT) area, PLNT thickness, LC thickness, LC area, and anterior LC surface depth, were derived from enhanced depth imaging optical coherence tomography of the LC. These parameters were used to train a Random Forest Classifier for classifying the eyes into three groups: normal, mild to moderate glaucoma, and severe glaucoma. Internal validation was performed using a five-fold stratified cross-validation, and SHapley Additive exPlanations (SHAP) values applied to determine the model interpretability. Results: The ML model average accuracy was 0.6392±0.1270, with F1-scores (the harmonic mean of precision and recall) of 0.7124 for “normal,” 0.5514 for “mild to moderate glaucoma,” and 0.5921 for “severe glaucoma.” The SHAP analysis identified PLNT area, PLNT thickness, and anterior LC surface depth as the most influential parameters for classification. Conclusion: The ML model created using enhanced depth imaging optical coherence tomography LC parameters provided an objective approach in glaucoma diagnosis and staging, while offering clear explanations for its classifications. By identifying parameters such as PLNT area as highly predictive features, the model enhanced the clinical understanding of the structural changes in the LC. External validation is required for broad clinical application.

  • Open Access

    Prevalence of Plateau Iris in Primary Angle Closure Glaucoma: An Egyptian Hospital Based Ultrasound Biomicroscopy Study

    by Amira E Hamad, Ahmed F Elmaria, Tarek R Hussein, Said M Shalaby

    Purpose: To determine the distribution and the anatomical characteristics of plateau iris (PI) in primary angle closure glaucoma (PACG) using ultrasound biomicroscopy (UBM). Methods: Fifty UBM images of PACG cases were studied over one year by retrospective analysis. The data from UBM images including angle opening distance at 500 and 750 mu m (AOD500 and A0D750), trabecular-iris angle (TIA), angle recess area at 750 mu m (ARA750), maximum ciliary body thickness (CBTmax), anterior placement of ciliary processes (APCP), central anterior chamber depth (CACD), axial lens thickness (ALT), and ciliary sulcus status were analyzed and compared between the PI and non-PI cases. Results: Eighteen cases had PI (36%). The mean AOD500, A0D750, and TIA were significantly smaller in PI than in non-PI eyes (P = 0.01; P = 0.046; and P = 0.026). Values of the ARA750 and CBTmax were not significantly different between the two groups (P = 0.208 and P = 0.368). CACD was deeper in the PI group (P = 0.011). ALT was higher in the non-PI group (P = 0.001). The mean APCP of the PI group was more than those of the non-PI group (P < 0.001). The number of cases with obliterated ciliary sulcus in more than two quadrants was significantly more in the PI group (P < 0.001). Conclusion: Around one-third of PACG eyes were found to have PI on UBM imaging The number of obliterated ciliary sulcus and APCP were important UBM parameters that help in PI diagnosis.


  • Open Access

    Correlation Between Changes in Lamina Cribrosa Structure and Visual Field in Primary Open-Angle Glaucoma

    by Ahmed El Basty, Raouf Gaber, Ahmed Elmaria, Moataz Sabry, Tarek R Hussein

    Purpose: To investigate the correlation between changes in lamina cribrosa (LC) structure using enhanced depth imaging (EDI) and severity of visual field (VF) affection in primary open-angle glaucoma (POAG). Patients and Methods: This prospective cross-sectional study was carried out on 52 glaucomatous eyes of 28 POAG patients who attended Tanta University Eye Hospital and 40 normal eyes of 20 age-matched normal subjects from April 2020 to March 2021. POAG patients were classified according to the modified Hodapp–Anderson–Parrish grading scale based on the MD of the standard automated perimetry (SAP) visual field into two groups: group (1) – mild-to-moderate POAG patients (MD ≤ 12 dB), group (2) – severe POAG patients (MD ≥ 12 dB) and the third group included normal (control) age- and gender-matched individuals. Results: There was no statistically significant difference between the three groups regarding lamina cribrosa thickness nor lamina cribrosa area and there was no statistically significant correlation between MD and LC thickness, LC area (P-value=0.395 and 0.644). There was a statistically significant correlation between MD and anterior lamina cribrosa surface depth (P-value=0.002) and there was a statistically significant positive correlation between MD and prelaminar neural tissue (PLNT) thickness and prelaminar neural tissue (PLNT) area (P-value= 0.023 and < 0.001, respectively). Conclusion: EDI-OCT is a useful biomarker of structural changes in ONH and LC, and we recommended it to be a part of the routine monitoring of patients with POAG.