Jennifer A. Kirwan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jennifer A. Kirwan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Anna Bauer
Berlin Institute of Health (BIH) @ Charité—Universitätsmedizin Berlin, BIH Metabolomics Platform, 13125 Berlin, Germany
1 shared publication - Christina A. Fleming
Department of Colorectal Surgery, University Hospital Limerick, Limerick, Ireland; Department of Surgery, Royal College of Surgeons Ireland, Dublin, Ireland; School of Medicine, University of Limerick, Limerick, Ireland
1 shared publication - Henry Paul Redmond
Department of Academic Surgery, University College Cork, Cork University Hospital, Cork, Ireland
1 shared publication - Raphaela Fritsche-Guenther
Berlin Institute of Health at Charité–Universitätsmedizin Berlin
1 shared publication - Stefan Kempa
Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC)
1 shared publication - Tobias Opialla
Department of Proteomics and Metabolomics Max-Delbrück-Center for Molecular Medicine Berlin, Berlin Institute for Medical Systems Biology, Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 18 December 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (12) , 888
Optimized Workflow for On-Line Derivatization for Targeted Metabolomics Approach by Gas Chromatography-Mass Spectrometry
Using manual derivatization in gas chromatography-mass spectrometry samples have varying equilibration times before analysis which increases technical variability and limits the number of potential samples analyzed. By contrast, automated derivatization methods can derivatize and inject each sample in an identical manner. We present a fully automated (on-line) derivatization method used for targeted analysis of different matrices. We describe method optimization and compare results from using off-line and on-line derivatization protocols, including the robustness and reproducibility of the methods. Our final parameters for the derivatization process were 20 µL of methoxyamine (MeOx) in pyridine for 60 min at 30 °C followed by 80 µL N-Methyl-N-trimethylsilyltrifluoracetamide (MSTFA) for 30 min at 30 °C combined with 4 h of equilibration time. The repeatability test in plasma and liver revealed a median relative standard deviation (RSD) of 16% and 10%, respectively. Serum samples showed a consistent intra-batch median RSD of 20% with an inter-batch variability of 27% across three batches. The direct comparison of on-line versus off-line demonstrated that on-line was fit for purpose and improves repeatability with a measured median RSD of 11% compared to 17% using the same method off-line. In summary, we recommend that optimized on-line methods may improve results for metabolomics and should be used where available.
- 18 December 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (12) , 888
Open AccessOptimized Workflow for On-Line Derivatization for Targeted Metabolomics Approach by Gas Chromatography-Mass Spectrometry
Using manual derivatization in gas chromatography-mass spectrometry samples have varying equilibration times before analysis which increases technical variability and limits the number of potential samples analyzed. By contrast, automated derivatization methods can derivatize and inject each sample in an identical manner. We present a fully automated (on-line) derivatization method used for targeted analysis of different matrices. We describe method optimization and compare results from using off-line and on-line derivatization protocols, including the robustness and reproducibility of the methods. Our final parameters for the derivatization process were 20 µL of methoxyamine (MeOx) in pyridine for 60 min at 30 °C followed by 80 µL N-Methyl-N-trimethylsilyltrifluoracetamide (MSTFA) for 30 min at 30 °C combined with 4 h of equilibration time. The repeatability test in plasma and liver revealed a median relative standard deviation (RSD) of 16% and 10%, respectively. Serum samples showed a consistent intra-batch median RSD of 20% with an inter-batch variability of 27% across three batches. The direct comparison of on-line versus off-line demonstrated that on-line was fit for purpose and improves repeatability with a measured median RSD of 11% compared to 17% using the same method off-line. In summary, we recommend that optimized on-line methods may improve results for metabolomics and should be used where available.