Bin Qin has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single‑Field, Single‑Switch: A Framework for Proton Bragg Peak FLASH Radiotherapy Using Universal Range Shifters

    by Qi Zhang, Hong Quan, Bo Pang, Muyu Liu, Shuoyan Chen, Hexiao Wang, Cong He, Qingguo Xie, Bin Qin, Xu Liu, et al.

    Background and purpose: Single-field optimization (SFO) is intrinsically attractive for proton Bragg Peak (BP) FLASH radiotherapy (FLASH-RT) because it delivers the entire fractional dose with a single beam, thus reducing field overlap and temporal interruptions that can lead to the degradation of ultra-high dose rate (UHDR) conditions. However, SFO is associated with limited degrees of freedom that pose a challenge for efforts to achieve clinically acceptable dose conformality, particularly for BP proton FLASH delivery. This study presents an SFO-based optimization framework that integrates universal range shifter (URS) modulation to enable single-switch BP proton FLASH-RT with preserved UHDR performance and improved dose conformality.Materials and Methods: A sparsity-promoting inverse planning framework was developed to perform SFO under a single-switch delivery paradigm. For each beam, optimization of URS thickness was performed to position the BP at the distal target edge, with the option of introducing a second URS thickness, allowing only a single URS switch event per beam to enhance longitudinal dose conformality. Beam angles, couch angles, URS configurations, spot weights, and fractional doses were jointly optimized while employing non-uniform fractionation to maintain a cumulative tumor biological effective dose (BED) of 100 Gy. The proposed SFO-based URS-modulated BP FLASH plans were generated for 10 brain, 10 lung, and 10 liver cases, and compared with conventional multi-energy Intensity-Modulated Proton Therapy (IMPT) plans and single-energy transmission beam (TB) FLASH plans with uniform fractionation. Plan quality, delivery efficiency, and dose-rate performance were evaluated through the use of dosimetric indices, beam delivery time, and dose-rate metrics based on dose-averaged dose rate (DADR) and average dose rate (ADR).Results: Across all sites, the SFO-based URS-modulated BP FLASH plans achieved sub-second beam delivery times (0.22 ± 0.06 s for brain; p < 0.001, URS-modulated BP vs. IMPT; 0.14 ± 0.04 s for lung; p = 0.002, URS-modulated BP vs. IMPT; and 0.31 ± 0.11 s for liver; p = 0.006, URS-modulated BP vs. IMPT), compared with 4.3–7.6 s per beam in IMPT plans. Target conformality was substantially improved relative to TB FLASH plans, with conformality indices of 0.62 ± 0.06, 0.64 ± 0.01, and 0.65 ± 0.11 for brain, lung, and liver cases, respectively, compared with 0.35–0.40 for TB plans (p < 0.001, URS-modulated BP vs. TB for all sites), while remaining below those of IMPT (0.81–0.84; p < 0.001, URS-modulated BP vs. IMPT for all sites). In normal tissues, near-complete UHDR coverage based on DADR was achieved for URS-modulated BP plans (>97% across all sites), whereas IMPT plans afforded negligible UHDR coverage (<2%; p < 0.001, URS-modulated BP vs. IMPT for all sites). ADR-based V40Gy/s in normal tissues reached 55.6% ± 4.0% for brain, 70.6% ± 10.4% for lung, and 59.1% ± 6.2% for liver cases in URS-modulated BP plans.Conclusion: Through the explicit formulation of proton FLASH planning within an SFO framework and augmenting it with limited URS-modulated BP modulation, clinically feasible single-switch BP FLASH-RT can be achieved with preserved UHDR conditions, markedly reduced delivery time, and substantially improved dose conformality over transmission FLASH.

  • Miniaturization design study of a dipole magnet applied to proton therapy beamline

    by Xuchuan Liang, Yu Chen, Yicheng Liao, Qushan Chen, Ziyi Yang, Zhenyi Yang, Xu Liu, Bin Qin

    The miniaturization of magnets is crucial for reducing both the physical footprint and the construction cost of a proton therapy facility. The configuration of dipole magnets significantly influences the design of the compact gantry. However, current research demonstrates a degree of subjectivity in achieving an optimal balance between magnet compactness and saturation levels. This study introduces a novel design principle aimed at miniaturizing the yoke of dipole magnets. To be specific, two metrics (i.e. magnet efficiency and magnetization uniformity) are adopted to develop an optimized design that achieves significant weight reduction while maintaining essential magnetic performance characteristics. For the 57-degree dipole magnet discussed in this paper, finite element simulations demonstrate that the optimized design achieves a weight reduction of 39.6% for the yoke (from 5.38 to 3.24 tons) while maintaining transverse and integrated field homogeneity within the stringent [ ] tolerance threshold, and exhibits satisfactory excitation linearity. The design of this study can provide insight for the subsequent construction of a compact gantry.


  • A data-efficient surrogate modeling method for a cyclotron-based proton therapy beamline based on active learning

    by Yu Chen, Bin Qin, Xu Liu, Wei Wang, Yicheng Liao

    High-fidelity beamline models typically involve particle-tracking and particle–matter interaction, which are intensive computationally demanding and time-consuming. This has led researchers to adopt data-driven surrogate models as an alternative to complex physics simulations. Training a data-driven model requires many labeled data, prompting researchers to simulate diverse beamline settings and obtain corresponding labels. However, the required dataset grows increasingly large as the number of adjustable parameters increases. Therefore, this study proposes a data-efficient surrogate modeling method that employs a student–teacher framework combined with active learning (AL) query strategies to minimize labeled samples while ensuring model accuracy. The proposed method is evaluated on the energy selection system (ESS) design of the Huazhong University of Science and Technology proton therapy facility (HUST-PTF). The results show that: (i) Training the surrogate model using 684 labeled samples selected via query strategy achieves a relative error below 5% for 90% of the samples in the test set. (ii) Compared to the beamline model built by Beam Delivery Simulation (BDSIM), the computational efficiency of the surrogate model is enhanced by a factor of [ ].


  • Design of a large momentum acceptance proton therapy gantry utilizing AG-CCT magnets

    by Yi-Cheng Liao, Xu Liu, Wei Wang, Zi-Yi Yang, Qu-Shan Chen, Bin Qin


  • A Framework for the Magnetic Design of Large Bore, Curved AG-CCT Magnets for Proton Therapy Facilities

    by Yicheng Liao, Xu Liu, Chunyi Li, Zhenyi Yang, Qushan Chen, Bin Qin

    The canted-cosine-theta (CCT) magnet is a promising candidate for shrinking the volume of the gantry for radiotherapy facilities. The magnets are often demanded to have large bores and small bending radii in the gantry design, which would lead to complex harmonic coupling and non-negligible fringe-field effects. To address these issues, a design framework is proposed in this contribution. The winding coefficients of the CCT coils are firstly determined by an improved backcasting algorithm to cancel out the harmonics. A toroidal shielding iron is mounted outside of the coil afterward, which can not only lower the stray field but also significantly eliminate the overshooting of the fringe field. The excitation efficiency of the magnet is enhanced by the shield without introducing any high-order harmonics. This framework is validated on an AG-CCT magnet being developed for our superconducting proton therapy gantry. The field derivatives and particle tracking results meet our optical design value well.


  • Feasibility study of multiple‐energy Bragg peak proton FLASH on a superconducting gantry with large momentum acceptance

    by Yiling Zeng, Heng Li, Wei Wang, Xu Liu, Bin Qin, Shuyang Dai, Bo Pang, Muyu Liu, Hong Quan, Kunyu Yang, et al.

    Background: While the Bragg peak proton beam (BP) is capable of superior target conformity and organs‐at‐risk sparing than the transmission proton beam (TB), its efficacy in FLASH‐RT is hindered by both a slow energy switching process and the beam current. A universal range shifter (URS) can pull back the high‐energy proton beam while preserving the beam current. Meanwhile, a superconducting gantry with large momentum acceptance (LMA‐SC gantry) enables fast energy switching.Purpose: This study explores the feasibility of multiple‐energy BP FLASH‐RT on the LMA‐SC gantry.Method and Materials: A simultaneous dose and spot map optimization algorithm was developed for BP FLASH‐RT treatment planning to improve the dose delivery efficiency. The URS was designed to be 0–27 cm thick, with 1 cm per step. BP plans using the URS were optimized using single‐field optimization (SFO) and multiple‐field optimization (MFO) for ten prostate cancer patients and ten lung cancer patients. The plan delivery parameters, dose, and dose rate metrics of BP plans were compared to those of TB plans using the parameters of the LMA‐SC gantry.Results: Compared to TB plans, BP plans significantly reduced MUs by 42.7% (P < 0.001) with SFO and 33.3% (P < 0.001) with MFO for prostate cases. For lung cases, the reduction in MUs was 56.8% (P < 0.001) with SFO and 36.4% (P < 0.001) with MFO. BP plans also outperformed TB plans by reducing mean normal tissue doses. BP‐SFO plans achieved a reduction of 56.7% (P < 0.001) for prostate cases and 57.7% (P < 0.001) for lung cases, while BP‐MFO plans achieved a reduction of 54.2% (P < 0.001) for the prostate case and 40.0% (P < 0.001) for lung cases. For both TB and BP plans, normal tissues in prostate and lung cases received 100.0% FLASH dose rate coverage (>40 Gy/s).Conclusions: By utilizing the URS and the LMA‐SC gantry, it is possible to perform multiple‐energy BP FLASH‐RT, resulting in better normal tissue sparing, as compared to TB plans.


  • Structural Analysis of a 4-Layer Curved Alternating Gradient Canted-Cosine-Theta Magnet Applied for Light-Weight Gantry

    by Aote Chen, Xu Liu, Dong Li, Qushan Chen, ChunYi Li, Bin Qin

    Superconducting magnets are preferable for the gantry applied to particle therapy, which are ascribed to their higher magnetic fields and relatively smaller size/weight compared to normal conducting magnets. Due to the large excitation current and inconsistent coefficient of thermal expansion of the different materials of the superconducting alternating gradient canted-cosine-theta magnet (AG-CCT), the Lorentz force and thermal stress are two main considerations in the AG-CCT structural analysis. However, a lot of computing power and time are needed to finish the AG-CCT full model stress analysis because of the complex structure of the mandrel. In this paper, a curved tube without ribs is employed to accelerate the stress analysis process. In the area with stress concentrations, the stress values with radial distribution on the mandrel are compared between the simplified model and the real AG-CCT model. The result shows that the relative deviation of stress in most regions is less than 10 $\%$ . Besides, a fast-modeling process was presented which can generate the AG-CCT model in an hour.