MTMateus Samuel Tonetto

Mateus Samuel Tonetto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mateus Samuel Tonetto has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a customized three-dimensional airway model

    by Mateus Samuel Tonetto, Hugo Goulart de Oliveira, Andre Frotta Muller, Paulo Roberto Stefani Sanches, Luciano Folador, Felipe Soares Torres, Tiago Severo Garcia

    This study aimed to develop a customized, three-dimensional airway model based on relevant medical images, using additive manufacturing techniques. We evaluated the model’s ability to replicate the dimensions of the images acquired from the chest of a patient using multi-detector computed tomography (CT). Using dedicated software, a three-dimensional mesh was created based on the images. A multi-detector CT study of the full-scale printed three-dimensional airways model was subsequently carried out to compare its dimensions with that of the original study at four predetermined points. The observed median differences at the four points were 0.4 mm (p = 0.686), -1.3 mm (p = 0.138), 0.7 mm (p = 0.141), and 0.1 mm (p = 0.892). The intraclass correlation coefficient between the measurements made on the patient and those on the model was 0.98 (95% confidence interval: 0.96–0.99, p < 0.001). We successfully developed a three-dimensional model of the airway based on its corresponding medical images. The differences in the dimensions between the model and the original images were in line with those observed in previous studies and are presumably irrelevant for most applications.


  • Open Access

    Interobserver agreement regarding the Fleischner Society diagnostic criteria for usual interstitial pneumonia patterns on computed tomography

    by Stephanie Sander Westphalen, Felipe Soares Torres, Mateus Samuel Tonetto, Juliana Fischman Zampieri, Giovanni Brondani Torri, Tiago Severo Garcia

    Objective: To assess interobserver agreement among radiologists regarding the current Fleischner Society diagnostic criteria for usual interstitial pneumonia (UIP) patterns on computed tomography (CT). Materials and Methods: Using the Fleischner Society criteria for UIP CT patterns, five raters, working independently, categorized the high-resolution CT (HRCT) scans of 44 patients with interstitial lung disease who underwent lung biopsy. The raters also evaluated the presence, extent, and distribution of the most relevant imaging findings, as well as indicating their level of confidence in the most likely diagnosis and in up to three diagnostic hypotheses. Results: There was moderate to substantial interobserver agreement regarding the UIP patterns on HRCT—kappa statistic (κ) = 0.59-0.61. Interobserver agreement for the binary scores was substantial (κ = 0.77-0.79), whereas that for the presence of honeycombing was almost perfect (κ = 0.81-0.96). There was agreement regarding at least one of the three diagnostic hypotheses in only 36.4% of the cases. For the level of confidence in the most likely diagnosis, there was only slight to fair agreement (κ = 0.19-0.21). Conclusion: Interobserver agreement regarding the current Fleischner Society CT criteria for UIP was moderate to substantial among raters with varying levels of experience. There was only slight to fair agreement regarding the diagnostic hypotheses and for the level of confidence in the most likely diagnosis.


  • Open Access

    Navegação em software livre e impressão 3D: princípios básicos e simulações em Cirurgia e Traumatologia Buco-Maxilo-Faciais

    by Leandro Rios Guidolin, André Frotta Müller, Mateus Samuel Tonetto, Amália Pletsch Furlanetto, Edela Puricelli, Alexandre Silva de Quevedo, Deise Ponzoni

    A utilização de sistemas computacionais permite a educação continuada aos profissionais, o estudo e planejamento cirúrgico virtual e a obtenção de objetos físicos diretamente a partir dos dados gerados. As imagens obtidas a partir da tomografia computadorizada podem ser manipuladas através de softwares livres. A prototipagem rápida é amplamente utilizada em Cirurgia e Traumatologia Buco-maxilo-faciais permitindo aumentar a previsibilidade cirúrgica, reduzindo o tempo associado ao procedimento e consequentemente resultando em menor morbidade ao paciente, baixando os custos vinculados à assistência em saúde. Este trabalho descreve o protocolo do emprego de técnicas de prototipagem rápida aplicadas a pacientes com necessidades de tratamento na especialidade de Cirurgia e Traumatologia Buco-maxilo-faciais, em nível terciário de atenção em saúde, vinculados ao Sistema Único de Saúde, em um hospital escola do sul do Brasil. Explora ainda, parâmetros relacionados a aquisição da imagem por tomografia computadorizada, características estruturais dos softwares utilizados, dos equipamentos e critérios de qualidade dimensional dos materiais utilizados. A adoção dessas tecnologias poderá trazer melhora na qualidade assistencial, devendo ser estimulada dentro do Sistema Único de Saúde.


  • Open Access

    Diagnostic performance of the RSNA-proposed classification for COVID-19 pneumonia versus pre-pandemic controls

    by Cauã O. Rocha, Tássia A.D. Prioste, Carlo S. Faccin, Luciano Folador, Mateus S. Tonetto, Pedro G. Knijnik, Natalia B. Mainardi, Rogério B. Borges, Tiago S. Garcia