Anjan Kumar Dash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anjan Kumar Dash has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Mangavu Ganesh
School of Mechanical Engineering SASTRA University, Thanjavur, India-613401
8 shared publications - I-Ming Chen
Nanyang Technological University
6 shared publications Song Huat Yeo
5 shared publicationsGuilin Yang
4 shared publicationsBanke Bihari
School of Mechanical Engineering, SASTRA University, Thanjavur, 613401, Tamil Nadu, India
2 shared publicationsDhiraj Kumar
School of Mechanical Engineering, SASTRA University, Thanjavur, 613401, Tamil Nadu, India
2 shared publications
Latest Publications
- 3 July 2026
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 21 (7) , 3919-3933
Design and development of a dual-power stroke lever-propelled wheelchair in limited resource setting: a pilot user evaluation
This study presents the design and development of a lever-propelled wheelchair with a novel propulsion system aimed at reducing user effort and fatigue by improving propulsion efficiency and ergonomics. A cost-effective and user-friendly prototype was developed to benefit individuals with lower limb disabilities, particularly those in low-income settings. A descriptive review of the literature and patents was conducted to identify the current advancements in wheelchair design and features. Essential features from the tricycle and lever-propelled wheelchairs are considered in the prototype design, in adherence to the WHO wheelchair standards. A CAD model was designed based on these standards and considering the low-cost manufacturing process to match the low-resource setting. The prototype was then fabricated using the standard manufacturing process. Trials were conducted with 25 unimpaired participants following a brief familiarisation and training session. Participants performed repeated propulsion trials along a predefined outdoor course involving straight-line motion, turning, and braking. User feedback on ease of use, comfort, safety, and propulsion effectiveness was collected using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0). Based on the participants trials, received positive feedback, which provides preliminary support for the developed wheelchairs propulsion mechanism, stability, and overall build quality. The user provides feedback on ease of use because of the dual-power stroke mechanism, which reduces a significant amount of user effort in propelling the wheelchair, manufactured in limited-resource settings.
- 3 July 2026
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 21 (7) , 3919-3933
Design and development of a dual-power stroke lever-propelled wheelchair in limited resource setting: a pilot user evaluation
This study presents the design and development of a lever-propelled wheelchair with a novel propulsion system aimed at reducing user effort and fatigue by improving propulsion efficiency and ergonomics. A cost-effective and user-friendly prototype was developed to benefit individuals with lower limb disabilities, particularly those in low-income settings. A descriptive review of the literature and patents was conducted to identify the current advancements in wheelchair design and features. Essential features from the tricycle and lever-propelled wheelchairs are considered in the prototype design, in adherence to the WHO wheelchair standards. A CAD model was designed based on these standards and considering the low-cost manufacturing process to match the low-resource setting. The prototype was then fabricated using the standard manufacturing process. Trials were conducted with 25 unimpaired participants following a brief familiarisation and training session. Participants performed repeated propulsion trials along a predefined outdoor course involving straight-line motion, turning, and braking. User feedback on ease of use, comfort, safety, and propulsion effectiveness was collected using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0). Based on the participants trials, received positive feedback, which provides preliminary support for the developed wheelchairs propulsion mechanism, stability, and overall build quality. The user provides feedback on ease of use because of the dual-power stroke mechanism, which reduces a significant amount of user effort in propelling the wheelchair, manufactured in limited-resource settings.
- 1 January 2022
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 37 (6) , 411-420
DETERMINATION OF CLOSED-FORM MATHEMATICAL EXPRESSION OF VOLUME OF CONSTANT ORIENTATION WORKSPACE FOR GOUGH–STEWART PLATFORM
Gough–Stewart platform is the most celebrated 6-Degrees of freedom (DOF) parallel manipulator.
- 1 January 2022
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 37 (6) , 411-420
DETERMINATION OF CLOSED-FORM MATHEMATICAL EXPRESSION OF VOLUME OF CONSTANT ORIENTATION WORKSPACE FOR GOUGH–STEWART PLATFORM
Gough–Stewart platform is the most celebrated 6-Degrees of freedom (DOF) parallel manipulator.
- 2 June 2021
- Published by Springer Nature
- p. 773-782
7-DOF Bionic Arm: Mapping Between data gloves and EMG arm band and Control by EMG arm band
- 2 June 2021
- Published by Springer Nature
- p. 773-782
7-DOF Bionic Arm: Mapping Between data gloves and EMG arm band and Control by EMG arm band
- 6 May 2020
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 39 (1) , 88-106
Static Characteristic Analysis of Spatial (Non-Planar) Links in Planar Parallel Manipulator
Conventional planar manipulators have their links in a single plane. Increasing payload at the end effector/mobile platform can induce high stress in the links due to the cantilever nature of links. Thus, it limits the total vertical load that can be applied on the mobile platform. In contrast to the links in conventional planar parallel mechanisms, non-planar links are proposed in this paper, that is, links are made inclined to the horizontal plane and non-planar legs are constructed. Though the links are made non-planar, the end effectors’ planar motion is retained. For studying the application of such non-planar links in planar manipulators, new models of inertia, stiffness and leg dynamics have to be developed. In this article, these models are developed by the static analysis of the planar manipulators with non-planar links, and the performance is compared with the corresponding conventional planar manipulators.
- 6 May 2020
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 39 (1) , 88-106
Static Characteristic Analysis of Spatial (Non-Planar) Links in Planar Parallel Manipulator
Conventional planar manipulators have their links in a single plane. Increasing payload at the end effector/mobile platform can induce high stress in the links due to the cantilever nature of links. Thus, it limits the total vertical load that can be applied on the mobile platform. In contrast to the links in conventional planar parallel mechanisms, non-planar links are proposed in this paper, that is, links are made inclined to the horizontal plane and non-planar legs are constructed. Though the links are made non-planar, the end effectors’ planar motion is retained. For studying the application of such non-planar links in planar manipulators, new models of inertia, stiffness and leg dynamics have to be developed. In this article, these models are developed by the static analysis of the planar manipulators with non-planar links, and the performance is compared with the corresponding conventional planar manipulators.
- Open Access
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 764 (1)
Modelling and analysis of femur bone from CT scan
About 200 million peoples around the world are affected by different types of bone diseases. Osteoporosis is one among them which is a low bone density disease which increases the porosity of the bone and leads to severe pain and fracture of the human bone. Women’s are most affected by this disease due to various reasons. It can be only predicted after the failure or fracture of the bone when the sudden impact of the load. The femur is the longest bone in the human body which is mainly affected by means of fracture due to osteoporosis. The strength of the bone mainly depends on its density and can be determined by the Bone Mineral Density (BMD) Test. Hence it is necessary to numerically predict the stress and deformation of bone for the osteoporosis patient in their daily activities. Nowadays many researches have been undergone in Finite Element Analysis (FEA) of human bone in order to predict the stress and deformation when subjected to various loads in daily life. In this work, Structural analysis is carried out on femur bone which is modelled from CT scan report and material properties are assigned from osteoporosis patient. The loading conditions are based on the force which exerts on the femur bone during routine activities. The analysis is carried out with two different boundary conditions and it is seen that the femur head and distal end of the femur is subjected towards maximum normal stress and deformation.
- 1 February 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 764 (1)
Open AccessModelling and analysis of femur bone from CT scan
About 200 million peoples around the world are affected by different types of bone diseases. Osteoporosis is one among them which is a low bone density disease which increases the porosity of the bone and leads to severe pain and fracture of the human bone. Women’s are most affected by this disease due to various reasons. It can be only predicted after the failure or fracture of the bone when the sudden impact of the load. The femur is the longest bone in the human body which is mainly affected by means of fracture due to osteoporosis. The strength of the bone mainly depends on its density and can be determined by the Bone Mineral Density (BMD) Test. Hence it is necessary to numerically predict the stress and deformation of bone for the osteoporosis patient in their daily activities. Nowadays many researches have been undergone in Finite Element Analysis (FEA) of human bone in order to predict the stress and deformation when subjected to various loads in daily life. In this work, Structural analysis is carried out on femur bone which is modelled from CT scan report and material properties are assigned from osteoporosis patient. The loading conditions are based on the force which exerts on the femur bone during routine activities. The analysis is carried out with two different boundary conditions and it is seen that the femur head and distal end of the femur is subjected towards maximum normal stress and deformation.
- Open Access
- 1 January 2020
- Published by Chinese Institute of Automation Engineers in International Journal of Automation and Smart Technology
- Vol. 10 (1) , 501-509
An Application of a 3-RRRS 6 DOF Parallel Manipulator
A new drive simulator is designed and fabricated through three legged, 6-DOF 3-RRRS (Revolute- Revolute- Revolute- Spherical) parallel manipulator having three 1-DOF joints which are of revolute type and the middle joint being passive. The three legs are placed equilaterally on the base. Base joint rotates about a vertical axis whereas the other two joints rotate parallel to horizontal plane. The main objective of this drive simulator is to reduce the overall cost of a drive simulator which is done by replacing the conventional drive simulators having linear actuators with ones having rotatory actuators. Conventional drive simulators are 6 legged and each actuator is a linear actuator. The proposed design of drive simulator is having 3 legs which leads to increase in workspace and since prismatic actuators are replaced by rotary actuators the overall cost is also reduced. For the proposed drive simulator, inverse kinematics model is generated in a closed form way and workspace of the fabricated drive simulator is verified and workspace volume is calculated for all possible orientations and plotted. Kinematic control is done through Arduino based on inverse kinematics model.
- 1 January 2020
- Published by Chinese Institute of Automation Engineers in International Journal of Automation and Smart Technology
- Vol. 10 (1) , 501-509
Open AccessAn Application of a 3-RRRS 6 DOF Parallel Manipulator
A new drive simulator is designed and fabricated through three legged, 6-DOF 3-RRRS (Revolute- Revolute- Revolute- Spherical) parallel manipulator having three 1-DOF joints which are of revolute type and the middle joint being passive. The three legs are placed equilaterally on the base. Base joint rotates about a vertical axis whereas the other two joints rotate parallel to horizontal plane. The main objective of this drive simulator is to reduce the overall cost of a drive simulator which is done by replacing the conventional drive simulators having linear actuators with ones having rotatory actuators. Conventional drive simulators are 6 legged and each actuator is a linear actuator. The proposed design of drive simulator is having 3 legs which leads to increase in workspace and since prismatic actuators are replaced by rotary actuators the overall cost is also reduced. For the proposed drive simulator, inverse kinematics model is generated in a closed form way and workspace of the fabricated drive simulator is verified and workspace volume is calculated for all possible orientations and plotted. Kinematic control is done through Arduino based on inverse kinematics model.
- 1 January 2019
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 34 (2) , 135-145
A NEW WORKSPACE ANALYSIS METHOD FOR 6-DOF 3-RRRS PARALLEL MANIPULATORS
Considering spatial parallel manipulators, volume and shape of the workspace are two important parameters foroptimum design.
- 1 January 2019
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 34 (2) , 135-145
A NEW WORKSPACE ANALYSIS METHOD FOR 6-DOF 3-RRRS PARALLEL MANIPULATORS
Considering spatial parallel manipulators, volume and shape of the workspace are two important parameters foroptimum design.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Workspace Analysis Of A 6-DOF 3-RRRS Parallel Manipulator
The design of a spatial parallel robot is governed by two factors: volume of the workspace and shape of the workspace. In this paper, we subject a 6-DOF 3RRRS parallel manipulator having symmetric link lengths, under research. The most commonly used method to solve robot kinematics based on the Denavit-Hartenberg (D-H) notation. Since its inverse kinematics involves complicated calculations and solutions, there has been a need to develop a new method which can meet the demands of real-time applications. Derived from the basis of screw theory, a new improved inverse kinematic approach, which improves the efficiency of the inverse kinematics, is used. Along with Paden-Kahan sub-problems, a new and improved subproblem is used to counter the aforementioned problems. In order to arrive at a robust design, the required volume is taken as input while all parameters relating to a manipulator design, such as the link lengths, the moving plate and base plate radius, the orientation, the home angle configuration are all treated as variables while computing the inverse kinematics. In each case, the corresponding geometric relationship between the parameters of the manipulators is established. The configuration which satisfies the user requirements as well as with the least amount of singularities is provided as the result.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Workspace Analysis Of A 6-DOF 3-RRRS Parallel Manipulator
The design of a spatial parallel robot is governed by two factors: volume of the workspace and shape of the workspace. In this paper, we subject a 6-DOF 3RRRS parallel manipulator having symmetric link lengths, under research. The most commonly used method to solve robot kinematics based on the Denavit-Hartenberg (D-H) notation. Since its inverse kinematics involves complicated calculations and solutions, there has been a need to develop a new method which can meet the demands of real-time applications. Derived from the basis of screw theory, a new improved inverse kinematic approach, which improves the efficiency of the inverse kinematics, is used. Along with Paden-Kahan sub-problems, a new and improved subproblem is used to counter the aforementioned problems. In order to arrive at a robust design, the required volume is taken as input while all parameters relating to a manipulator design, such as the link lengths, the moving plate and base plate radius, the orientation, the home angle configuration are all treated as variables while computing the inverse kinematics. In each case, the corresponding geometric relationship between the parameters of the manipulators is established. The configuration which satisfies the user requirements as well as with the least amount of singularities is provided as the result.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 108-112
Innovative Application of Slider-Crank Mechanism
Slider-Crank is an age-old, well-proven mechanism. In this paper, its application in a manually powered wheelchair is explored. Detailed design is given and a prototype based on the design is also fabricated. It is also compared to existing wheel chairs in the national and international market. Analysis proves that it is better than its counter parts.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 108-112
Innovative Application of Slider-Crank Mechanism
Slider-Crank is an age-old, well-proven mechanism. In this paper, its application in a manually powered wheelchair is explored. Detailed design is given and a prototype based on the design is also fabricated. It is also compared to existing wheel chairs in the national and international market. Analysis proves that it is better than its counter parts.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-376
Modal analysis of a 6 D.O.F seismic simulator
Buildings built these days are made earthquake resistant. To test the efficiency of the buildings to withstand the seismic vibrations, a scaled model (or sometimes 1:1 prototype) is placed over a table called as `shake table'. This shake table has 6 degrees of freedom (DOF) and motions or vibrations are imparted to this table using actuators to test the earthquake resistance of the building. The risk is that if the natural frequency of the shake table matches with the imparted frequency, there will be a resonance and the shake table will fail. To ensure that the natural frequency of the shake table is not within the range of frequency of earthquake vibration, modal analysis is performed. In this paper, a methodology is proposed how to do the modal analysis of a 6 DOF parallel manipulator based on RPRS topology which is used as a shake table. An FFT analysis is also performed to determine the predominant frequency of the imparted earthquake data on the shale table.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 373-376
Modal analysis of a 6 D.O.F seismic simulator
Buildings built these days are made earthquake resistant. To test the efficiency of the buildings to withstand the seismic vibrations, a scaled model (or sometimes 1:1 prototype) is placed over a table called as `shake table'. This shake table has 6 degrees of freedom (DOF) and motions or vibrations are imparted to this table using actuators to test the earthquake resistance of the building. The risk is that if the natural frequency of the shake table matches with the imparted frequency, there will be a resonance and the shake table will fail. To ensure that the natural frequency of the shake table is not within the range of frequency of earthquake vibration, modal analysis is performed. In this paper, a methodology is proposed how to do the modal analysis of a 6 DOF parallel manipulator based on RPRS topology which is used as a shake table. An FFT analysis is also performed to determine the predominant frequency of the imparted earthquake data on the shale table.