Praveen K. Parashiva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Praveen K. Parashiva has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
A P Vinod
Department of Electrical Engineering, Indian Institute of Technology Palakkad, India
1 shared publicationA. P. Vinod
The Hong Kong University of Science and Technology,Dept. of Electronic and Computer Engineering,Hong Kong
1 shared publication- A. P. Vinod
Infocomm Technology, Singapore Institute of Technology, Singapore 828608, Singapore
1 shared publication - Sagila Gangadharan Kutteri
Infocomm Technology, Singapore Institute of Technology, Singapore 828608, Singapore
1 shared publication
Latest Publications
- Open Access
Subject-Specific Deep Learning Model for Motor Imagery Direction Decoding
Hemispheric strokes impair motor control in contralateral body parts, necessitating effective rehabilitation strategies. Motor imagery-based brain–computer interfaces (MI-BCIs) promote neuroplasticity, aiding the recovery of motor functions. While deep learning has shown promise in decoding MI actions for stroke rehabilitation, existing studies largely focus on bilateral MI actions and are limited to offline evaluations. Decoding directional information from unilateral MI, however, offers a more natural control interface with greater degrees of freedom but remains challenging due to spatially overlapping neural activity. This work proposes a novel deep learning framework for online decoding of binary directional MI signals from the dominant hand of 20 healthy subjects. The proposed method employs EEGNet-based convolutional filters to extract temporal and spatial features. The EEGNet model is enhanced by squeeze-and-excitation (SE) layers that rank the electrode importance and feature maps. A subject-independent model is initially trained using calibration data from multiple subjects and fine-tuned for subject-specific adaptation. The performance of the proposed method is evaluated using subject-specific online session data. The proposed method achieved an average right vs. left binary direction-decoding accuracy of for unilateral MI tasks, outperforming the existing deep learning models. Additionally, the SE-layer ranking offers insights into electrode contribution, enabling potential subject-specific BCI optimization. The findings highlight the efficacy of the proposed method in advancing MI-BCI applications for a more natural and effective control of BCI systems.Open AccessSubject-Specific Deep Learning Model for Motor Imagery Direction Decoding
Hemispheric strokes impair motor control in contralateral body parts, necessitating effective rehabilitation strategies. Motor imagery-based brain–computer interfaces (MI-BCIs) promote neuroplasticity, aiding the recovery of motor functions. While deep learning has shown promise in decoding MI actions for stroke rehabilitation, existing studies largely focus on bilateral MI actions and are limited to offline evaluations. Decoding directional information from unilateral MI, however, offers a more natural control interface with greater degrees of freedom but remains challenging due to spatially overlapping neural activity. This work proposes a novel deep learning framework for online decoding of binary directional MI signals from the dominant hand of 20 healthy subjects. The proposed method employs EEGNet-based convolutional filters to extract temporal and spatial features. The EEGNet model is enhanced by squeeze-and-excitation (SE) layers that rank the electrode importance and feature maps. A subject-independent model is initially trained using calibration data from multiple subjects and fine-tuned for subject-specific adaptation. The performance of the proposed method is evaluated using subject-specific online session data. The proposed method achieved an average right vs. left binary direction-decoding accuracy of for unilateral MI tasks, outperforming the existing deep learning models. Additionally, the SE-layer ranking offers insights into electrode contribution, enabling potential subject-specific BCI optimization. The findings highlight the efficacy of the proposed method in advancing MI-BCI applications for a more natural and effective control of BCI systems. - 22 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015026
Single-trial detection of EEG error-related potentials in serial visual presentation paradigm
When the outcome of an event is not the same as expected, the cognitive state that monitors performance elicits a time-locked brain response termed as Error-Related Potential (ErrP). Objective —In the existing work, ErrP is not recorded when there is a disassociation between an object and its description. The objective of this work is to propose a Serial Visual Presentation (SVP) experimental paradigm to record ErrP when an image and its label are disassociated. Additionally, this work aims to propose a novel method for detecting ErrP on a single-trial basis. Method— The method followed in this work includes designing of SVP paradigm in which labeled images from six categories (bike, car, flower, fruit, cat, and dog) are presented serially. In this work, a text (visual) or an audio clip describing the image in one word is presented as the label. Further, the ErrP is detected on a single-trial basis using novel electrode-averaged features. Results - The ErrP data recorded from 11 subjects’ have consistent characteristics compared to existing ErrP literature. Detection of ErrP on a single-trial basis is carried out using a novel feature extraction method on two type labeling types separately. The best average classification accuracy achieved is 69.09 ± 4.70 % and 63.33 ± 4.56 % for the audio and visual type of labeling the image, respectively. The proposed feature extraction method achieved higher classification accuracy when compared with two existing feature extraction methods. Significance - The significance of this work is that it can be used as a Brain-Computer Interface (BCI) system for quantitative evaluation and treatment of mild cognitive impairment. This work can also find non-clinical BCI applications such as image annotation.
- 22 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015026
Single-trial detection of EEG error-related potentials in serial visual presentation paradigm
When the outcome of an event is not the same as expected, the cognitive state that monitors performance elicits a time-locked brain response termed as Error-Related Potential (ErrP). Objective —In the existing work, ErrP is not recorded when there is a disassociation between an object and its description. The objective of this work is to propose a Serial Visual Presentation (SVP) experimental paradigm to record ErrP when an image and its label are disassociated. Additionally, this work aims to propose a novel method for detecting ErrP on a single-trial basis. Method— The method followed in this work includes designing of SVP paradigm in which labeled images from six categories (bike, car, flower, fruit, cat, and dog) are presented serially. In this work, a text (visual) or an audio clip describing the image in one word is presented as the label. Further, the ErrP is detected on a single-trial basis using novel electrode-averaged features. Results - The ErrP data recorded from 11 subjects’ have consistent characteristics compared to existing ErrP literature. Detection of ErrP on a single-trial basis is carried out using a novel feature extraction method on two type labeling types separately. The best average classification accuracy achieved is 69.09 ± 4.70 % and 63.33 ± 4.56 % for the audio and visual type of labeling the image, respectively. The proposed feature extraction method achieved higher classification accuracy when compared with two existing feature extraction methods. Significance - The significance of this work is that it can be used as a Brain-Computer Interface (BCI) system for quantitative evaluation and treatment of mild cognitive impairment. This work can also find non-clinical BCI applications such as image annotation.
- 8 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An Efficient Electrode Ranking Method for Single Trial Detection of EEG Error-Related Potentials
The human brain's response to mistakes or erroneous events is termed as Error-Related Potential (ErrP). The ErrP can be recorded non-invasively using Electroencephalogram (EEG). The ErrP activity is localized and gets reflected in a few EEG electrodes only. Further, EEG offers a poor signal-to-noise ratio. Therefore, single-trial detection of ErrP from EEG data is challenging. The objective of this work is to propose an efficient method for selecting electrodes that carry ErrP related information to enhance single-trial detection accuracy. In this work, the cosine similarity and Euclidian distance measures are used to rank the EEG electrodes. The selected top-ranked electrodes are used to extract electrode-average features followed by a classifier. This work is implemented on a public dataset containing 6 subjects' datasets each having 2 sessions of EEG data. The two proposed electrode ranking methods - cosine similarity measure and Euclidian distance measure are implemented separately. Both electrode ranking methods aided in achieving equally good ErrP detection rates. The cross-validated average detection rates achieved using the proposed electrode ranking methods are ~73.5% and ~80% for error and correct trials respectively. Further, the results are compared with three existing methods including Convolutional Neural Network (CNN) implemented on the same dataset used in this work to show the efficiency of the proposed method. The significance of this work is that the single-trial detection of ErrP can aid in improving the classification accuracy of decoding EEG tasks in Brain-Computer Interface systems.
- 8 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An Efficient Electrode Ranking Method for Single Trial Detection of EEG Error-Related Potentials
The human brain's response to mistakes or erroneous events is termed as Error-Related Potential (ErrP). The ErrP can be recorded non-invasively using Electroencephalogram (EEG). The ErrP activity is localized and gets reflected in a few EEG electrodes only. Further, EEG offers a poor signal-to-noise ratio. Therefore, single-trial detection of ErrP from EEG data is challenging. The objective of this work is to propose an efficient method for selecting electrodes that carry ErrP related information to enhance single-trial detection accuracy. In this work, the cosine similarity and Euclidian distance measures are used to rank the EEG electrodes. The selected top-ranked electrodes are used to extract electrode-average features followed by a classifier. This work is implemented on a public dataset containing 6 subjects' datasets each having 2 sessions of EEG data. The two proposed electrode ranking methods - cosine similarity measure and Euclidian distance measure are implemented separately. Both electrode ranking methods aided in achieving equally good ErrP detection rates. The cross-validated average detection rates achieved using the proposed electrode ranking methods are ~73.5% and ~80% for error and correct trials respectively. Further, the results are compared with three existing methods including Convolutional Neural Network (CNN) implemented on the same dataset used in this work to show the efficiency of the proposed method. The significance of this work is that the single-trial detection of ErrP can aid in improving the classification accuracy of decoding EEG tasks in Brain-Computer Interface systems.