Andrea Prestia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Prestia has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Mongardi
Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
6 shared publications - Danilo Demarchi
Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
6 shared publications - Fabio Rossi
Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
6 shared publications - Paolo Motto Ros
Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
4 shared publications - Massimo Ruo Roch
Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy
2 shared publications - Maurizio Martina
Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy
2 shared publications
Latest Publications
- Open Access
- 18 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (6) , 701
A Compositional Calibration Framework for Multi-Channel Functional Electrical Stimulation Enabling Hand Gesture Generation
The application of functional electrical stimulation (FES) to restore hand motor function remains challenging due to the difficulty of calibrating multi-channel stimulation to produce coordinated finger movements. This study proposes a compositional FES calibration framework to customize the stimulation of isolated finger actions and enable their combination into functional hand gestures. The proposed method was validated through a two-session experimental study involving thirteen participants. In the first session, subject-specific stimulation sites and parameters were identified for eight individual finger movements using a structured spatial grid defined over the forearm. The second session, conducted on a subset of five participants, evaluated the generation of seven hand gestures derived from combinations of the isolated movements. Results showed that ten of the thirteen participants achieved at least six movements, while three participants successfully elicited all targeted motions. Successfully elicited movements were generally well isolated, although thumb and ring/little finger extensions proved more difficult to isolate. The second session demonstrated that individually calibrated finger activations can be combined to produce coordinated multi-finger movement patterns, with average finger excursions matching the expected motions. Overall, these preliminary results support the use of compositional calibration strategies to achieve functional multi-finger control with multi-channel FES.
- 18 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (6) , 701
Open AccessA Compositional Calibration Framework for Multi-Channel Functional Electrical Stimulation Enabling Hand Gesture Generation
The application of functional electrical stimulation (FES) to restore hand motor function remains challenging due to the difficulty of calibrating multi-channel stimulation to produce coordinated finger movements. This study proposes a compositional FES calibration framework to customize the stimulation of isolated finger actions and enable their combination into functional hand gestures. The proposed method was validated through a two-session experimental study involving thirteen participants. In the first session, subject-specific stimulation sites and parameters were identified for eight individual finger movements using a structured spatial grid defined over the forearm. The second session, conducted on a subset of five participants, evaluated the generation of seven hand gestures derived from combinations of the isolated movements. Results showed that ten of the thirteen participants achieved at least six movements, while three participants successfully elicited all targeted motions. Successfully elicited movements were generally well isolated, although thumb and ring/little finger extensions proved more difficult to isolate. The second session demonstrated that individually calibrated finger activations can be combined to produce coordinated multi-finger movement patterns, with average finger excursions matching the expected motions. Overall, these preliminary results support the use of compositional calibration strategies to achieve functional multi-finger control with multi-channel FES.
- Open Access
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 148992-149009
Motion Tracking for Automatically Controlled Functional Electrical Stimulation System in Mirror Therapy Configuration: The Enhanced Lazarus Solution
In this work, we present the potential application of an automatic control system for adjusting the parameter values of Functional Electrical Stimulation (FES). FES is a key enabling technology in the functional recovery of patients undergoing neuro-muscular rehabilitation. In this application, successful stimulation outcomes depend on the accurate setting of patient-specific parameters – such as pulse width and stimulation frequency – which are typically determined by physiotherapists based on their clinical experience. The proposed system is implemented in a Mirror Therapy setup, where an injured limb is controlled via FES to replicate the movement of a healthy limb – either belonging to the same patient or to a physiotherapist. The FES activation signal is derived from surface Electromyography (sEMG) recordings of the healthy limb and transmitted to the FES unit after compression using an Average Threshold Crossing (ATC) algorithm. Optimal FES parameters are adjusted through a closed-loop feedback system based on motion tracking of the injured limb, which is continuously compared to the movement of the healthy limb. Additionally, we explore the possibility of replacing the ATC algorithm used for compressing the sEMG signal from the healthy limb with a Compressed Sensing-based approach. This alternative would enable full reconstruction of the sEMG signal – unlike ATC – at the cost of only a minimal increase in computational effort. A prototype was tested on 22 healthy subjects under five different parameter configurations, confirming the feasibility and adaptability of the proposed system.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 148992-149009
Open AccessMotion Tracking for Automatically Controlled Functional Electrical Stimulation System in Mirror Therapy Configuration: The Enhanced Lazarus Solution
In this work, we present the potential application of an automatic control system for adjusting the parameter values of Functional Electrical Stimulation (FES). FES is a key enabling technology in the functional recovery of patients undergoing neuro-muscular rehabilitation. In this application, successful stimulation outcomes depend on the accurate setting of patient-specific parameters – such as pulse width and stimulation frequency – which are typically determined by physiotherapists based on their clinical experience. The proposed system is implemented in a Mirror Therapy setup, where an injured limb is controlled via FES to replicate the movement of a healthy limb – either belonging to the same patient or to a physiotherapist. The FES activation signal is derived from surface Electromyography (sEMG) recordings of the healthy limb and transmitted to the FES unit after compression using an Average Threshold Crossing (ATC) algorithm. Optimal FES parameters are adjusted through a closed-loop feedback system based on motion tracking of the injured limb, which is continuously compared to the movement of the healthy limb. Additionally, we explore the possibility of replacing the ATC algorithm used for compressing the sEMG signal from the healthy limb with a Compressed Sensing-based approach. This alternative would enable full reconstruction of the sEMG signal – unlike ATC – at the cost of only a minimal increase in computational effort. A prototype was tested on 22 healthy subjects under five different parameter configurations, confirming the feasibility and adaptability of the proposed system.
- Open Access
A Fast and Low-Impact Embedded Orientation Correction Algorithm for Hand Gesture Recognition Armbands
Hand gesture recognition is a prominent topic in the recent literature, with surface ElectroMyoGraphy (sEMG) recognized as a key method for wearable Human–Machine Interfaces (HMIs). However, sensor placement still significantly impacts systems performance. This study addresses sensor displacement by introducing a fast and low-impact orientation correction algorithm for sEMG-based HMI armbands. The algorithm includes a calibration phase to estimate armband orientation and real-time data correction, requiring only two distinct hand gestures in terms of sEMG activation. This ensures hardware and database independence and eliminates the need for model retraining, as data correction occurs prior to classification or prediction. The algorithm was implemented in a hand gesture HMI system featuring a custom seven-channel sEMG armband with an Artificial Neural Network (ANN) capable of recognizing nine gestures. Validation demonstrated its effectiveness, achieving % average prediction accuracy with arbitrary armband wearing orientation. The algorithm also has minimal impact on power consumption and latency, requiring just an additional 500 μW and introducing a latency increase of 408 μs. These results highlight the algorithm’s efficacy, general applicability, and efficiency, presenting it as a promising solution to the electrode-shift issue in sEMG-based HMI applications.Open AccessA Fast and Low-Impact Embedded Orientation Correction Algorithm for Hand Gesture Recognition Armbands
Hand gesture recognition is a prominent topic in the recent literature, with surface ElectroMyoGraphy (sEMG) recognized as a key method for wearable Human–Machine Interfaces (HMIs). However, sensor placement still significantly impacts systems performance. This study addresses sensor displacement by introducing a fast and low-impact orientation correction algorithm for sEMG-based HMI armbands. The algorithm includes a calibration phase to estimate armband orientation and real-time data correction, requiring only two distinct hand gestures in terms of sEMG activation. This ensures hardware and database independence and eliminates the need for model retraining, as data correction occurs prior to classification or prediction. The algorithm was implemented in a hand gesture HMI system featuring a custom seven-channel sEMG armband with an Artificial Neural Network (ANN) capable of recognizing nine gestures. Validation demonstrated its effectiveness, achieving % average prediction accuracy with arbitrary armband wearing orientation. The algorithm also has minimal impact on power consumption and latency, requiring just an additional 500 μW and introducing a latency increase of 408 μs. These results highlight the algorithm’s efficacy, general applicability, and efficiency, presenting it as a promising solution to the electrode-shift issue in sEMG-based HMI applications. - Open Access
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (6) , 1348-1365
Hand Gestures Recognition for Human-Machine Interfaces: A Low-Power Bio-Inspired Armband
Hand gesture recognition has recently increased its popularity as Human-Machine Interface (HMI) in the biomedical field. Indeed, it can be performed involving many different non-invasive techniques, e.g., surface ElectroMyoGraphy (sEMG) or PhotoPlethysmoGraphy (PPG). In the last few years, the interest demonstrated by both academia and industry brought to a continuous spawning of commercial and custom wearable devices, which tried to address different challenges in many application fields, from tele-rehabilitation to sign language recognition. In this work, we propose a novel 7-channel sEMG armband, which can be employed as HMI for both serious gaming control and rehabilitation support. In particular, we designed the prototype focusing on the capability of our device to compute the Average Threshold Crossing (ATC) parameter, which is evaluated by counting how many times the sEMG signal crosses a threshold during a fixed time duration (i.e., 130 ms), directly on the wearable device. Exploiting the event-driven characteristic of the ATC, our armband is able to accomplish the on-board prediction of common hand gestures requiring less power w.r.t. state of the art devices. At the end of an acquisition campaign that involved the participation of 26 people, we obtained an average classifier accuracy of 91.9% when aiming to recognize in real time 8 active hand gestures plus the idle state. Furthermore, with 2.92mA of current absorption during active functioning and 1.34mA prediction latency, this prototype confirmed our expectations and can be an appealing solution for long-term (up to 60 h) medical and consumer applications.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (6) , 1348-1365
Open AccessHand Gestures Recognition for Human-Machine Interfaces: A Low-Power Bio-Inspired Armband
Hand gesture recognition has recently increased its popularity as Human-Machine Interface (HMI) in the biomedical field. Indeed, it can be performed involving many different non-invasive techniques, e.g., surface ElectroMyoGraphy (sEMG) or PhotoPlethysmoGraphy (PPG). In the last few years, the interest demonstrated by both academia and industry brought to a continuous spawning of commercial and custom wearable devices, which tried to address different challenges in many application fields, from tele-rehabilitation to sign language recognition. In this work, we propose a novel 7-channel sEMG armband, which can be employed as HMI for both serious gaming control and rehabilitation support. In particular, we designed the prototype focusing on the capability of our device to compute the Average Threshold Crossing (ATC) parameter, which is evaluated by counting how many times the sEMG signal crosses a threshold during a fixed time duration (i.e., 130 ms), directly on the wearable device. Exploiting the event-driven characteristic of the ATC, our armband is able to accomplish the on-board prediction of common hand gestures requiring less power w.r.t. state of the art devices. At the end of an acquisition campaign that involved the participation of 26 people, we obtained an average classifier accuracy of 91.9% when aiming to recognize in real time 8 active hand gestures plus the idle state. Furthermore, with 2.92mA of current absorption during active functioning and 1.34mA prediction latency, this prototype confirmed our expectations and can be an appealing solution for long-term (up to 60 h) medical and consumer applications.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (1) , 3-14
Motion Analysis for Experimental Evaluation of an Event-Driven FES System
In this work, a system for controlling Functional Electrical Stimulation (FES) has been experimentally evaluated. The peculiarity of the system is to use an event-driven approach to modulate stimulation intensity, instead of the typical feature extraction of surface ElectroMyoGraphic (sEMG) signal. To validate our methodology, the system capability to control FES was tested on a population of 17 subjects, reproducing 6 different movements. Limbs trajectories were acquired using a gold standard motion tracking tool. The implemented segmentation algorithm has been detailed, together with the designed experimental protocol. A motion analysis was performed through a multiparametric evaluation, including the extraction of features such as the trajectory area and the movement velocity. The obtained results show a median cross-correlation coefficient of 0.910 and a median delay of 800 ms, between each couple of voluntary and stimulated exercise, making our system comparable w.r.t. state-of-the-art works. Furthermore, a 97.39% successful rate on movement replication demonstrates the feasibility of the system for rehabilitation purposes.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (1) , 3-14
Motion Analysis for Experimental Evaluation of an Event-Driven FES System
In this work, a system for controlling Functional Electrical Stimulation (FES) has been experimentally evaluated. The peculiarity of the system is to use an event-driven approach to modulate stimulation intensity, instead of the typical feature extraction of surface ElectroMyoGraphic (sEMG) signal. To validate our methodology, the system capability to control FES was tested on a population of 17 subjects, reproducing 6 different movements. Limbs trajectories were acquired using a gold standard motion tracking tool. The implemented segmentation algorithm has been detailed, together with the designed experimental protocol. A motion analysis was performed through a multiparametric evaluation, including the extraction of features such as the trajectory area and the movement velocity. The obtained results show a median cross-correlation coefficient of 0.910 and a median delay of 800 ms, between each couple of voluntary and stimulated exercise, making our system comparable w.r.t. state-of-the-art works. Furthermore, a 97.39% successful rate on movement replication demonstrates the feasibility of the system for rehabilitation purposes.
- Open Access
Combining Action Observation Treatment with a Brain–Computer Interface System: Perspectives on Neurorehabilitation
Action observation treatment (AOT) exploits a neurophysiological mechanism, matching an observed action on the neural substrates where that action is motorically represented. This mechanism is also known as mirror mechanism. In a typical AOT session, one can distinguish an observation phase and an execution phase. During the observation phase, the patient observes a daily action and soon after, during the execution phase, he/she is asked to perform the observed action at the best of his/her ability. Indeed, the execution phase may sometimes be difficult for those patients where motor impairment is severe. Although, in the current practice, the physiotherapist does not intervene on the quality of the execution phase, here, we propose a stimulation system based on neurophysiological parameters. This perspective article focuses on the possibility to combine AOT with a brain–computer interface system (BCI) that stimulates upper limb muscles, thus facilitating the execution of actions during a rehabilitation session. Combining a rehabilitation tool that is well-grounded in neurophysiology with a stimulation system, such as the one proposed, may improve the efficacy of AOT in the treatment of severe neurological patients, including stroke patients, Parkinson’s disease patients, and children with cerebral palsy.
Open AccessCombining Action Observation Treatment with a Brain–Computer Interface System: Perspectives on Neurorehabilitation
Action observation treatment (AOT) exploits a neurophysiological mechanism, matching an observed action on the neural substrates where that action is motorically represented. This mechanism is also known as mirror mechanism. In a typical AOT session, one can distinguish an observation phase and an execution phase. During the observation phase, the patient observes a daily action and soon after, during the execution phase, he/she is asked to perform the observed action at the best of his/her ability. Indeed, the execution phase may sometimes be difficult for those patients where motor impairment is severe. Although, in the current practice, the physiotherapist does not intervene on the quality of the execution phase, here, we propose a stimulation system based on neurophysiological parameters. This perspective article focuses on the possibility to combine AOT with a brain–computer interface system (BCI) that stimulates upper limb muscles, thus facilitating the execution of actions during a rehabilitation session. Combining a rehabilitation tool that is well-grounded in neurophysiology with a stimulation system, such as the one proposed, may improve the efficacy of AOT in the treatment of severe neurological patients, including stroke patients, Parkinson’s disease patients, and children with cerebral palsy.