Peteris Prieditis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peteris Prieditis has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Maija Radzina
Radiology Research Laboratory, Riga Stradins University, Riga, Latvia
2 shared publications - Mara Liepa
Radiology Research Laboratory, Riga Stradins University, LV-1007 Riga, Latvia
2 shared publications - Arturs Ozolins
Department of Surgery, Pauls Stradiņš Clinical University Hospital, Riga, Latvia
1 shared publication - Cosimo Durante
Department of Translational and Precision Medicine, Sapienza University of Rome, 00185 Rome, Italy
1 shared publication - Elina Tauvena
Faculty of Medicine, Riga Stradins University, LV-1007 Riga, Latvia
1 shared publication - Giorgio Grani
Department of Translational and Precision Medicine, Sapienza University of Rome, 00185 Rome, Italy
1 shared publication
Latest Publications
- Open Access
Non-Marked Hypoechogenic Nodules: Multicenter Study on the Thyroid Malignancy Risk Stratification and Accuracy Based on TIRADS Systems Comparison
Background and Objectives: The aim of the study was to evaluate the predictive value of the ultrasound criterion “non-marked hypoechogenicity” for malignancy and to determine whether classification of these nodules as TIRADS 3 could improve the overall accuracy of consequently adjusted M-TIRADS score. Materials and Methods: A total of 767 patients with 795 thyroid nodules were subject to ultrasonography examination and ultrasound-guided fine needle aspiration biopsy. Nodules were classified by Kwak TIRADS and modified (M-TIRADS) categories 4A, 4B, and 5 according to number of suspicious US features (marked hypoechogenicity, microlobulated or irregular margins, microcalcifications, taller-than-wide shape, metastatic lymph nodes). Non-marked hypoechoic nodules were classified as TIRADS 3. Results: Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, and 5 in 14.5, 57.5, 14.2, 8.1, and 5.7%, respectively. Only histopathologic results (125 nodules underwent surgery) and highly specific cytology results (Bethesda II, VI) were accepted as a standard of reference, forming a sub-cohort of 562/795 nodules (70.7%). Malignancy was found in 7.7%. Overall, M-TIRADS showed sensitivity/specificity of 93.02/81.31%, and for PPV/NPV, these were 29.2/99.29%, respectively (OR—18.62). Irregular margins showed the highest sensitivity and specificity (75.68/93.74%, respectively). In TIRADS 3 category, 37.2% nodules were isoechoic, 6.6% hyperechoic, and 52.2% hypoechoic (there was no difference of malignancy risk in hypoechoic nodules between M-TIRADS and Kwak systems—0.9 vs. 0.8, respectively). Accuracy of M-TIRADS classification in this cohort was 78.26% vs. 48.11% for Kwak. Conclusions: The non-marked hypoechoic nodule pattern correlated with low risk of malignancy; classification of these nodules as TIRADS 3 significantly improved the predictive value and overall accuracy of the proposed M-TIRADS scoring with malignancy risk increase in TIRADS 4 categories by 20%; and no significant alteration of malignancy risk in TIRADS 3 could contribute to reducing overdiagnosis, obviating the need for FNA.
Open AccessNon-Marked Hypoechogenic Nodules: Multicenter Study on the Thyroid Malignancy Risk Stratification and Accuracy Based on TIRADS Systems Comparison
Background and Objectives: The aim of the study was to evaluate the predictive value of the ultrasound criterion “non-marked hypoechogenicity” for malignancy and to determine whether classification of these nodules as TIRADS 3 could improve the overall accuracy of consequently adjusted M-TIRADS score. Materials and Methods: A total of 767 patients with 795 thyroid nodules were subject to ultrasonography examination and ultrasound-guided fine needle aspiration biopsy. Nodules were classified by Kwak TIRADS and modified (M-TIRADS) categories 4A, 4B, and 5 according to number of suspicious US features (marked hypoechogenicity, microlobulated or irregular margins, microcalcifications, taller-than-wide shape, metastatic lymph nodes). Non-marked hypoechoic nodules were classified as TIRADS 3. Results: Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, and 5 in 14.5, 57.5, 14.2, 8.1, and 5.7%, respectively. Only histopathologic results (125 nodules underwent surgery) and highly specific cytology results (Bethesda II, VI) were accepted as a standard of reference, forming a sub-cohort of 562/795 nodules (70.7%). Malignancy was found in 7.7%. Overall, M-TIRADS showed sensitivity/specificity of 93.02/81.31%, and for PPV/NPV, these were 29.2/99.29%, respectively (OR—18.62). Irregular margins showed the highest sensitivity and specificity (75.68/93.74%, respectively). In TIRADS 3 category, 37.2% nodules were isoechoic, 6.6% hyperechoic, and 52.2% hypoechoic (there was no difference of malignancy risk in hypoechoic nodules between M-TIRADS and Kwak systems—0.9 vs. 0.8, respectively). Accuracy of M-TIRADS classification in this cohort was 78.26% vs. 48.11% for Kwak. Conclusions: The non-marked hypoechoic nodule pattern correlated with low risk of malignancy; classification of these nodules as TIRADS 3 significantly improved the predictive value and overall accuracy of the proposed M-TIRADS scoring with malignancy risk increase in TIRADS 4 categories by 20%; and no significant alteration of malignancy risk in TIRADS 3 could contribute to reducing overdiagnosis, obviating the need for FNA.
- Open Access
Contrast-Enhanced Ultrasound Qualitative and Quantitative Characteristics of Parathyroid Gland Lesions
Background and Objectives: preoperative differentiation of enlarged parathyroid glands may be challenging in conventional B-mode ultrasound. The aim of our study was to analyse qualitative and quantitative characteristics of parathyroid gland lesions, using multiparametric ultrasound protocol—B-mode, Colour Doppler (CD), and contrast-enhanced ultrasound (CEUS)—and to evaluate correlation with morphology in patients with hyperparathyroidism (HPT). Materials and Methods: consecutive 75 patients with 88 parathyroid lesions and biochemically confirmed HPT prior to parathyroidectomy were enrolled in the prospective study. B-mode ultrasound, CD, and CEUS were performed with the subsequent qualitative and quantitative evaluation of acquired data. We used 1 mL or 2 mL of intravenous ultrasound contrast agent during the CEUS examination. Correlation with post-surgical morphology was evaluated. Results: seventy parathyroid adenomas were hypoechoic and well contoured with increased central echogenicity (44.3%), peripheral-central vascularization (47%), and polar feeding vessel (100%). Twelve hyperplasias presented with similar ultrasound appearance and were smaller in volume (p = 0.036). Hyperplasias had a tendency for homogenous, marked intense enhancement vs. peripherally enhanced adenomas with central wash-out in CEUS after quantitative analysis. No significant difference was observed in contrasting dynamics, regardless of contrast media volume use (1 mL vs. 2 mL). We achieved 90.9% sensitivity and 72.7% specificity, 93% positive predictive value (PPV), 87.3% negative predictive value (NPV), and 87.3% accuracy in the differentiation of parathyroid lesions prior to post-processing. In a quantitative lesion analysis, our sensitivity increased up to 98%, specificity 80%, PPV 98%, and NPV 80% with an accuracy of 96.4%. Conclusions: CEUS of parathyroid lesions shows potential in the differentiation of adenoma from hyperplasia, regardless of the amount of contrast media injected. The quantitative analysis improved the sensitivity and specificity of differentiation between parathyroid lesions. Hyperplasia was characterized by homogeneous enhancement, fast uptake, and homogeneous wash-out appearance; adenoma—by peripheral uptake, central wash-out, and reduced hemodynamics. The use of CEUS quantification methods are advised to improve the ultrasound diagnostic role in suspected parathyroid lesions.
Open AccessContrast-Enhanced Ultrasound Qualitative and Quantitative Characteristics of Parathyroid Gland Lesions
Background and Objectives: preoperative differentiation of enlarged parathyroid glands may be challenging in conventional B-mode ultrasound. The aim of our study was to analyse qualitative and quantitative characteristics of parathyroid gland lesions, using multiparametric ultrasound protocol—B-mode, Colour Doppler (CD), and contrast-enhanced ultrasound (CEUS)—and to evaluate correlation with morphology in patients with hyperparathyroidism (HPT). Materials and Methods: consecutive 75 patients with 88 parathyroid lesions and biochemically confirmed HPT prior to parathyroidectomy were enrolled in the prospective study. B-mode ultrasound, CD, and CEUS were performed with the subsequent qualitative and quantitative evaluation of acquired data. We used 1 mL or 2 mL of intravenous ultrasound contrast agent during the CEUS examination. Correlation with post-surgical morphology was evaluated. Results: seventy parathyroid adenomas were hypoechoic and well contoured with increased central echogenicity (44.3%), peripheral-central vascularization (47%), and polar feeding vessel (100%). Twelve hyperplasias presented with similar ultrasound appearance and were smaller in volume (p = 0.036). Hyperplasias had a tendency for homogenous, marked intense enhancement vs. peripherally enhanced adenomas with central wash-out in CEUS after quantitative analysis. No significant difference was observed in contrasting dynamics, regardless of contrast media volume use (1 mL vs. 2 mL). We achieved 90.9% sensitivity and 72.7% specificity, 93% positive predictive value (PPV), 87.3% negative predictive value (NPV), and 87.3% accuracy in the differentiation of parathyroid lesions prior to post-processing. In a quantitative lesion analysis, our sensitivity increased up to 98%, specificity 80%, PPV 98%, and NPV 80% with an accuracy of 96.4%. Conclusions: CEUS of parathyroid lesions shows potential in the differentiation of adenoma from hyperplasia, regardless of the amount of contrast media injected. The quantitative analysis improved the sensitivity and specificity of differentiation between parathyroid lesions. Hyperplasia was characterized by homogeneous enhancement, fast uptake, and homogeneous wash-out appearance; adenoma—by peripheral uptake, central wash-out, and reduced hemodynamics. The use of CEUS quantification methods are advised to improve the ultrasound diagnostic role in suspected parathyroid lesions.