MGMaria Teresa Gandia-Ferrero

Maria Teresa Gandia-Ferrero

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maria Teresa Gandia-Ferrero has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Begoña Martínez-Sanchis

    Nuclear Medicine Department, La Fe University and Polytechnic Hospital, València, Spain

    3 shared publications
  • Irene Torres-Espallardo

    Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute (IIS La Fe), Valencia, Spain

    3 shared publications
  • Luis Martí-Bonmatí

    Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute (IIS La Fe), Valencia, Spain

    3 shared publications
  • Miquel Baquero-Toledo

    Polytech Hosp, Ave Fernando Abril Martorell, Valencia 46026, Spain

    3 shared publications
  • Constantino Morera-Ballester

    Oncovision, Carrer Jeroni Montsoriu 92, Valencia 46022, Spain

    2 shared publications
  • Consuelo Cháfer-Pericás

    Neurology Service, La Fe University and Polytechnic Hospital, Avenida Fernando Abril Martorell, Valencia, Spain

    2 shared publications

Latest Publications

  • Amyloid brain-dedicated PET images can diagnose Alzheimer’s pathology with Centiloid Scale

    by Maria Teresa Gandia-Ferrero, Irene Torres-Espallardo, Begoña Martínez-Sanchis, Enrique Muñoz, Constantino Morera-Ballester, Pablo Sopena-Novales, Lourdes Álvarez-Sánchez, Miquel Baquero-Toledo, Luis Martí-Bonmatí


  • Objective Image Quality Comparison Between Brain-Dedicated PET and PET/CT Scanners

    by Maria Teresa Gandia-Ferrero, Irene Torres-Espallardo, Begoña Martínez-Sanchis, Constantino Morera-Ballester, Enrique Muñoz, Pablo Sopena-Novales, Gabriel González-Pavón, Luis Martí-Bonmatí

    As part of a clinical validation of a new brain-dedicated PET system (CMB), image quality of this scanner has been compared to that of a whole-body PET/CT scanner. To that goal, Hoffman phantom and patient data were obtined with both devices. Since CMB does not use a CT for attenuation correction (AC) which is crucial for PET images quality, this study includes the evaluation of CMB PET images using emission-based or CT-based attenuation maps. PET images were compared using 34 image quality metrics. Moreover, a neural network was used to evaluate the degree of agreement between both devices on the patients diagnosis prediction. Overall, results showed that CMB images have higher contrast and recovery coefficient but higher noise than PET/CT images. Although SUVr values presented statistically significant differences in many brain regions, relative differences were low. An asymmetry between left and right hemispheres, however, was identified. Even so, the variations between the two devices were minor. Finally, there is a greater similarity between PET/CT and CMB CT-based AC PET images than between PET/CT and the CMB emission-based AC PET images.


  • Open Access

    Objective image quality evaluation in a brain dedicated PET scanner

    by Gandia-Ferrero Maria Teresa, Torres-Espallardo Irene, Martínez-Sanchis Begoña, Morera-Ballester Constantino, Muñoz Enrique, Sopena-Novales Pablo, González-Pavón Gabriel, Martí-Bonmatí Luis

    The image quality of a brain-dedicated PET system (CMB) compared to that of a whole-body PET/CT scanner has been evaluated. To that goal, Hoffman phantom and patient data were obtined with both devices. Since CMB does not use a CT for attenuation correction (AC) which is crucial for PET images quality, this study includes the evaluation of CMB PET images using emission-based or CT-based attenuation maps. PET images were compared using 34 image quality metrics. Moreover, a neural network was used to evaluate the degree of agreement between both devices on the patients diagnosis prediction. Overall, results showed that CMB images have higher contrast and recovery coefficient but higher noise than PET/CT images. Although SUVr values presented statistically significant differences in many brain regions, relative differences were low. An asymmetry between left and right hemispheres, however, was identified. Even so, the variations between the two devices were minor. Finally, there is a greater similarity between PET/CT and CMB CT-based AC PET images than between PET/CT and the CMB emission-based AC PET images.

  • Artificial Intelligence on FDG PET Images Identifies Mild Cognitive Impairment Patients with Neurodegenerative Disease

    by Joan Prats-Climent, Maria Teresa Gandia-Ferrero, Irene Torres-Espallardo, Lourdes Álvarez-Sanchez, Begoña Martínez-Sanchis, Consuelo Cháfer-Pericás, Ignacio Gómez-Rico, Leonor Cerdá-Alberich, Fernando Aparici-Robles, Miquel Baquero-Toledo, et al.

    The purpose of this project is to develop and validate a Deep Learning (DL) FDG PET imaging algorithm able to identify patients with any neurodegenerative diseases (Alzheimer's Disease (AD), Frontotemporal Degeneration (FTD) or Dementia with Lewy Bodies (DLB)) among patients with Mild Cognitive Impairment (MCI). A 3D Convolutional neural network was trained using images from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database. The ADNI dataset used for the model training and testing consisted of 822 subjects (472 AD and 350 MCI). The validation was performed on an independent dataset from La Fe University and Polytechnic Hospital. This dataset contained 90 subjects with MCI, 71 of them developed a neurodegenerative disease (64 AD, 4 FTD and 3 DLB) while 19 did not associate any neurodegenerative disease. The model had 79% accuracy, 88% sensitivity and 71% specificity in the identification of patients with neurodegenerative diseases tested on the 10% ADNI dataset, achieving an area under the receiver operating characteristic curve (AUC) of 0.90. On the external validation, the model preserved 80% balanced accuracy, 75% sensitivity, 84% specificity and 0.86 AUC. This binary classifier model based on FDG PET images allows the early prediction of neurodegenerative diseases in MCI patients in standard clinical settings with an overall 80% classification balanced accuracy.


  • Open Access

    Mild Cognitive Impairment Stratification by Artificial Intelligence on FDG PET

    by Joan Prats-Climent, Maria Teresa Gandia-Ferrero, Irene Torres-Espallardo, Lourdes Álvarez-Sanchez, Begoña Martínez-Sanchis, Consuelo Cháfer-Pericás, Ignacio Gómez-Rico-Junquero, Leonor Cerdá-Alberich, Fernando Aparici-Robles, Miquel Baquero-Toledo, et al.

    Purpose The purpose of this project is to develop and externally validate a Deep Learning (DL) FDG PET imaging algorithm able to identify patients with Alzheimer's Disease (AD), Frontotemporal Degeneration (FTD) and Dementia with Lewy Bodies (DLB) among a group of patients with Mild Cognitive Impairment (MCI). Methods A 3D Convolutional neural network, trained using images from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database, was implemented. The ADNI dataset used for training and testing the model consisted of 822 subjects (472 AD and 350 MCI). The external validation was performed on an independent dataset from our hospital. The hospital real world dataset contains 90 subjects with MCI: 71 patients that developed a neurodegenerative disease (64 AD, 4 FTD and 3 DLB) and 19 subjects without associated neurodegenerative disease. Results The ADNI model had 79% accuracy, 88% sensitivity and 71% specificity in the identification of patients with neurodegenerative diseases tested on the 10% ADNI dataset, achieving an area under the receiver operating characteristic curve (AUC) of 0.897. When used for the external validation, the model preserved 77% accuracy, 75% sensitivity, 84% specificity and 0.860 area under the ROC curve. Conclusion This model based on FDG PET images can help the early non-invasive prediction of neurodegenerative diseases in MCI patients in standard clinical settings with an overall 77% classification accuracy.