Sayed Abdullah Sadat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sayed Abdullah Sadat has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mostafa Sahraei-Ardakani
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
2 shared publications Benjamin Hwang
1 shared publicationJan Kleissl
1 shared publicationJorge Cortés
1 shared publication- Kibaek Kim
Mathematics and Computer Science Division Argonne National Laboratory Lemont IL USA
1 shared publication Kohei Murakami
1 shared publication
Latest Publications
- Open Access
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Real-Time Distributed Voltage Regulation of the UCSD Microgrid using the DERConnect Testbed
As distributed energy resources (DERs) become more widespread, they are fundamentally changing power system operations and creating new operational challenges. Controllable DERs have been found to be particularly effective in providing grid ancillary services such as voltage regulation. Leveraging advanced metering and communication infrastructure, scalable distributed control algorithms can further strengthen system reliability via DERs. This paper presents a novel distributed algorithm, based on the Alternating Direction Method of Multipliers (ADMM), for real-time voltage regulation in distribution systems. The algorithm coordinates DER control setpoints to deliver robust voltage support and is validated on the University of California, San Diego microgrid under varied and extreme loading conditions. Its effectiveness is both theoretically established and experimentally verified using the DERConnect testbed, which integrates control hardware-in-the-loop with large-scale simulation. Our results demonstrate the algorithm's adaptability and practical performance in realistic operational environments.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessReal-Time Distributed Voltage Regulation of the UCSD Microgrid using the DERConnect Testbed
As distributed energy resources (DERs) become more widespread, they are fundamentally changing power system operations and creating new operational challenges. Controllable DERs have been found to be particularly effective in providing grid ancillary services such as voltage regulation. Leveraging advanced metering and communication infrastructure, scalable distributed control algorithms can further strengthen system reliability via DERs. This paper presents a novel distributed algorithm, based on the Alternating Direction Method of Multipliers (ADMM), for real-time voltage regulation in distribution systems. The algorithm coordinates DER control setpoints to deliver robust voltage support and is validated on the University of California, San Diego microgrid under varied and extreme loading conditions. Its effectiveness is both theoretically established and experimentally verified using the DERConnect testbed, which integrates control hardware-in-the-loop with large-scale simulation. Our results demonstrate the algorithm's adaptability and practical performance in realistic operational environments.
- Open Access
- 29 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Tuning Successive Linear Programming to Solve AC Optimal Power Flow Problem for Large Networks
Successive linear programming (SLP) is a practical approach for solving large-scale nonlinear optimization problems. Alternating current optimal power flow (ACOPF) is no exception, particularly the large size of real-world networks. However, in order to achieve tractability, it is essential to tune the SLP algorithm presented in the literature. This paper presents a modified SLP algorithm to solve the ACOPF problem, specified by the U.S. Department of Energy’s (DOE) Grid Optimization (GO) Competition Challenge 1, within strict time limits. The algorithm first finds a near-optimal solution for the relaxed problem (i.e., Stage 1). Then, it finds a feasible solution in the proximity of the near-optimal solution (i.e., Stage 2 and Stage 3). The numerical experiments on test cases ranging from 500-bus to 30,000-bus systems show that the algorithm is tractable. The results show that our proposed algorithm is tractable and can solve more than 80\% of test cases faster than the well-known Interior Point Method while significantly reduce the number of iterations required to solve ACOPF. The number of iterations is considered an important factor in the examination of tractability which can drastically reduce the computational time required within each iteration.
- 29 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessTuning Successive Linear Programming to Solve AC Optimal Power Flow Problem for Large Networks
Successive linear programming (SLP) is a practical approach for solving large-scale nonlinear optimization problems. Alternating current optimal power flow (ACOPF) is no exception, particularly the large size of real-world networks. However, in order to achieve tractability, it is essential to tune the SLP algorithm presented in the literature. This paper presents a modified SLP algorithm to solve the ACOPF problem, specified by the U.S. Department of Energy’s (DOE) Grid Optimization (GO) Competition Challenge 1, within strict time limits. The algorithm first finds a near-optimal solution for the relaxed problem (i.e., Stage 1). Then, it finds a feasible solution in the proximity of the near-optimal solution (i.e., Stage 2 and Stage 3). The numerical experiments on test cases ranging from 500-bus to 30,000-bus systems show that the algorithm is tractable. The results show that our proposed algorithm is tractable and can solve more than 80\% of test cases faster than the well-known Interior Point Method while significantly reduce the number of iterations required to solve ACOPF. The number of iterations is considered an important factor in the examination of tractability which can drastically reduce the computational time required within each iteration.
- Open Access
- 12 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Customized Sequential Quadratic Programming for Solving Large-Scale AC Optimal Power Flow
After decades of research, efficient computation of AC Optimal Power Flow (ACOPF) still remains a challenge. ACOPF is a nonlinear nonconvex problem, and operators would need to solve ACOPF for large networks in almost real-time. Sequential Quadratic Programming (SQP) is one of the powerful second-order methods for solving large-scale nonlinear optimization problems and is a suitable approach for solving ACOPF with large-scale real-world transmission networks. However, SQP, in its general form, is still unable to solve large-scale problems within industry time limits. This paper presents a customized Sequential Quadratic Programming (CSQP) algorithm, taking advantage of physical properties of the ACOPF problem and the choice of the best performing ACOPF formulation. The numerical experiments suggest that CSQP outperforms commercial and noncommercial nonlinear solvers and solves test cases within the industry time limits. A wide range of test cases, ranging from 500-bus systems to 30,000-bus systems, are used to verify the test results.
- 12 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessCustomized Sequential Quadratic Programming for Solving Large-Scale AC Optimal Power Flow
After decades of research, efficient computation of AC Optimal Power Flow (ACOPF) still remains a challenge. ACOPF is a nonlinear nonconvex problem, and operators would need to solve ACOPF for large networks in almost real-time. Sequential Quadratic Programming (SQP) is one of the powerful second-order methods for solving large-scale nonlinear optimization problems and is a suitable approach for solving ACOPF with large-scale real-world transmission networks. However, SQP, in its general form, is still unable to solve large-scale problems within industry time limits. This paper presents a customized Sequential Quadratic Programming (CSQP) algorithm, taking advantage of physical properties of the ACOPF problem and the choice of the best performing ACOPF formulation. The numerical experiments suggest that CSQP outperforms commercial and noncommercial nonlinear solvers and solves test cases within the industry time limits. A wide range of test cases, ranging from 500-bus systems to 30,000-bus systems, are used to verify the test results.
- Open Access
Numerical Performance of Different Formulations for Alternating Current Optimal Power Flow
Alternating current optimal power flow (ACOPF) problems are nonconvex and nonlinear optimization problems. Utilities and independent service operators (ISO) require ACOPF to be solved in almost real time. Interior point methods (IPMs) are one of the powerful methods for solving large-scale nonlinear optimization problems and are a suitable approach for solving ACOPF with large-scale real-world transmission networks. Moreover, the choice of the formulation is as important as choosing the algorithm for solving an ACOPF problem. In this paper, different ACOPF formulations with various linear solvers and the impact of employing box constraints are evaluated for computational viability and best performance when using IPMs. Different optimization structures are used in these formulations to model the ACOPF problem representing a range of sparsity. The numerical experiments suggest that the least sparse ACOPF formulations with polar voltages yield the best computational results. Additionally, nodal injected models and current-based branch flow models are improved by enforcing box constraints. A wide range of test cases, ranging from 500-bus systems to 9591-bus systems, are used to verify the test results.
Open AccessNumerical Performance of Different Formulations for Alternating Current Optimal Power Flow
Alternating current optimal power flow (ACOPF) problems are nonconvex and nonlinear optimization problems. Utilities and independent service operators (ISO) require ACOPF to be solved in almost real time. Interior point methods (IPMs) are one of the powerful methods for solving large-scale nonlinear optimization problems and are a suitable approach for solving ACOPF with large-scale real-world transmission networks. Moreover, the choice of the formulation is as important as choosing the algorithm for solving an ACOPF problem. In this paper, different ACOPF formulations with various linear solvers and the impact of employing box constraints are evaluated for computational viability and best performance when using IPMs. Different optimization structures are used in these formulations to model the ACOPF problem representing a range of sparsity. The numerical experiments suggest that the least sparse ACOPF formulations with polar voltages yield the best computational results. Additionally, nodal injected models and current-based branch flow models are improved by enforcing box constraints. A wide range of test cases, ranging from 500-bus systems to 9591-bus systems, are used to verify the test results.
- Open Access
- 9 May 2018
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Design Automation of Electronic Systems
- Vol. 23 (4) , 1-15
Optimal Allocation of LDOs and Decoupling Capacitors within a Distributed On-Chip Power Grid
Parallel on-chip voltage regulation, where multiple regulators are connected to the same power grid, has recently attracted significant attention with the proliferation of small on-chip voltage regulators. In this article, the number, size, and location of parallel low-dropout (LDO) regulators and intentional decoupling capacitors are optimized using mixed integer non-linear programming formulation. The proposed optimization function concurrently considers multiple objectives such as area, power noise, and overall power consumption. Certain objectives are optimized by putting constraints on the other objectives with the proposed technique. Additional constraints have been added to avoid the overlap of LDOs and decoupling capacitors in the optimization process. The results of an optimized LDO allocation in the POWER8 chip is compared with the recent LDO allocation in the same IBM chip in a case study where a 20% reduction in the noise is achieved. The results of the proposed multi-criteria objective function under a different area, power, and noise constraints are also evaluated with a sample ISPD’11 benchmark circuits in another case study.
- 9 May 2018
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Design Automation of Electronic Systems
- Vol. 23 (4) , 1-15
Open AccessOptimal Allocation of LDOs and Decoupling Capacitors within a Distributed On-Chip Power Grid
Parallel on-chip voltage regulation, where multiple regulators are connected to the same power grid, has recently attracted significant attention with the proliferation of small on-chip voltage regulators. In this article, the number, size, and location of parallel low-dropout (LDO) regulators and intentional decoupling capacitors are optimized using mixed integer non-linear programming formulation. The proposed optimization function concurrently considers multiple objectives such as area, power noise, and overall power consumption. Certain objectives are optimized by putting constraints on the other objectives with the proposed technique. Additional constraints have been added to avoid the overlap of LDOs and decoupling capacitors in the optimization process. The results of an optimized LDO allocation in the POWER8 chip is compared with the recent LDO allocation in the same IBM chip in a case study where a 20% reduction in the noise is achieved. The results of the proposed multi-criteria objective function under a different area, power, and noise constraints are also evaluated with a sample ISPD’11 benchmark circuits in another case study.