Yucheng Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yucheng Shi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Deren Kong
School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
3 shared publications Chunyan Zhang
School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, China
2 shared publications- Xuejiao Ma
School of Mechanical Engineering, Nanjing University of Science and Technology, Jiangsu, Nanjing, China
2 shared publications - Chunyan Zhang
School of Traffic Engineering, Nanjing Institute of Technology, Nanjing, China
1 shared publication - Deren Kong
School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
1 shared publication
Latest Publications
- 24 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11704-11712
Dynamic Calibration Method of Blast Pressure Pencil Probes Based on Adjustable Shock Tube
Dynamic calibration is one of the important ways to obtain the dynamic performance parameters of pressure sensors, and shock tube calibration is a common method for dynamic calibration of pressure sensors. To study the dynamic calibration method of the shock tube of the blast pressure pencil probes, such as free-field pressure sensors and dynamic pressure sensors, a convenient and adjustable PVC-U (unplasticized polyvinyl chloride) shock tube is developed. Taking the dynamic pressure sensor as the research object, the feasibility of dynamic calibration of shock tube based on CFD (Computational Fluid Dynamics) techniques is discussed. Finally, the dynamic calibration experiment based on shock tube is carried out, and the time-domain and frequency-domain signals are analyzed. The results are in good agreement with the theoretical analysis. The results show that the shock tube can effectively excite the natural frequency of the dynamic pressure sensor, and the developed shock tube can indeed achieve the dynamic calibration and dynamic experiments of pencil probes.
- 24 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11704-11712
Dynamic Calibration Method of Blast Pressure Pencil Probes Based on Adjustable Shock Tube
Dynamic calibration is one of the important ways to obtain the dynamic performance parameters of pressure sensors, and shock tube calibration is a common method for dynamic calibration of pressure sensors. To study the dynamic calibration method of the shock tube of the blast pressure pencil probes, such as free-field pressure sensors and dynamic pressure sensors, a convenient and adjustable PVC-U (unplasticized polyvinyl chloride) shock tube is developed. Taking the dynamic pressure sensor as the research object, the feasibility of dynamic calibration of shock tube based on CFD (Computational Fluid Dynamics) techniques is discussed. Finally, the dynamic calibration experiment based on shock tube is carried out, and the time-domain and frequency-domain signals are analyzed. The results are in good agreement with the theoretical analysis. The results show that the shock tube can effectively excite the natural frequency of the dynamic pressure sensor, and the developed shock tube can indeed achieve the dynamic calibration and dynamic experiments of pencil probes.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (21) , 20312-20320
Research on Natural Frequency of Piezoelectric Pressure Sensor Affected by Preload
The natural frequency of piezoelectric pressure sensors is seriously affected by preload, but there is currently a lack of relevant quantitative analysis, resulting in the lack of corresponding theoretical basis for sensor design and packaging. In order to solve the above problems, based on the fractal theory, the relationship between the preload and the normal contact stiffness under different surface topography and element materials is deduced and simply verified by finite element simulation. Based on the sensor structure and size, a dynamics model is established, and the relationship between the preload and the natural frequency is obtained. Shock tube calibration experiments with different preload are used to verify the correctness of the relationship. The experimental results are similar to the theoretical calculations, proving the correctness and feasibility of the theory. The theoretical calculation results can be used for the selection of the preload and the estimation of the natural frequency of the actual piezoelectric pressure sensor, which is of great significance for the mass production of piezoelectric pressure sensors.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (21) , 20312-20320
Research on Natural Frequency of Piezoelectric Pressure Sensor Affected by Preload
The natural frequency of piezoelectric pressure sensors is seriously affected by preload, but there is currently a lack of relevant quantitative analysis, resulting in the lack of corresponding theoretical basis for sensor design and packaging. In order to solve the above problems, based on the fractal theory, the relationship between the preload and the normal contact stiffness under different surface topography and element materials is deduced and simply verified by finite element simulation. Based on the sensor structure and size, a dynamics model is established, and the relationship between the preload and the natural frequency is obtained. Shock tube calibration experiments with different preload are used to verify the correctness of the relationship. The experimental results are similar to the theoretical calculations, proving the correctness and feasibility of the theory. The theoretical calculation results can be used for the selection of the preload and the estimation of the natural frequency of the actual piezoelectric pressure sensor, which is of great significance for the mass production of piezoelectric pressure sensors.
- Open Access
Measurement and Analysis of Shock Wave Pressure in Moving Charge and Stationary Charge Explosions
Shock wave pressure is one of the most important parameters in an explosion. However, there have been few experimental and analytical investigations of moving charge explosions. In this article, we present an experimental method to measure the shock wave pressure from a moving charge explosion. Tests of stationary charges and moving charges with speeds of 580 m/s, 703 m/s and 717 m/s were carried out. The shock wave pressure curves and parameters at different measurement points were obtained and analyzed. The theoretical calculation of the shock wave overpressure was studied and compared with the experimental result. The differences between the stationary charge and moving charge explosions were investigated. The results showed that the shock wave pressure distribution of a moving charge had strong directionality. The shock wave pressure parameters (including overpressure, arrival time, duration and impulse) were influenced by the charge’s moving velocity, direction angle and distance from the blast point. The shock wave overpressure value was greater than that of a stationary charge explosion at angles between 0° and 90°. The correlation model based on the velocity vector superposition method could describe the relationship of overpressure between the stationary charge and moving charge explosions.
Open AccessMeasurement and Analysis of Shock Wave Pressure in Moving Charge and Stationary Charge Explosions
Shock wave pressure is one of the most important parameters in an explosion. However, there have been few experimental and analytical investigations of moving charge explosions. In this article, we present an experimental method to measure the shock wave pressure from a moving charge explosion. Tests of stationary charges and moving charges with speeds of 580 m/s, 703 m/s and 717 m/s were carried out. The shock wave pressure curves and parameters at different measurement points were obtained and analyzed. The theoretical calculation of the shock wave overpressure was studied and compared with the experimental result. The differences between the stationary charge and moving charge explosions were investigated. The results showed that the shock wave pressure distribution of a moving charge had strong directionality. The shock wave pressure parameters (including overpressure, arrival time, duration and impulse) were influenced by the charge’s moving velocity, direction angle and distance from the blast point. The shock wave overpressure value was greater than that of a stationary charge explosion at angles between 0° and 90°. The correlation model based on the velocity vector superposition method could describe the relationship of overpressure between the stationary charge and moving charge explosions.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (24) , 27325-27334
Research of a Sensor Used to Calculate the Dynamic Pressure of Chemical Explosions
To meet the growing demand for shock wave dynamic pressure measurements of conventional chemical explosion, based on the pitot tube measurement principle, a sensor used to calculate the dynamic pressure is designed. The so-called dynamic pressure sensor is an updated model of pitot-static tube and free-field pressure sensor. Based on the principle of dynamic pressure formation in the explosion field and the relationship between total pressure, static pressure and dynamic pressure, using computational fluid dynamics simulation, the aerodynamic characteristics of the sensor are explored, the structural dimensions of the sensor and the installation positions of the sensitive elements are determined. In view of the special environment of the explosion field, a dynamic pressure test system is built, 10kg, 20kg and 30kg cylindrical TNT explosion experiments are completed, the dynamic pressure signal processing methods are proposed and the complete dynamic pressure waveforms are obtained. The final results show that the sensor can effectively measure the dynamic pressure signal, which is essential to improve the dynamic pressure measurement capability and promote the development of new high-energy warheads.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (24) , 27325-27334
Research of a Sensor Used to Calculate the Dynamic Pressure of Chemical Explosions
To meet the growing demand for shock wave dynamic pressure measurements of conventional chemical explosion, based on the pitot tube measurement principle, a sensor used to calculate the dynamic pressure is designed. The so-called dynamic pressure sensor is an updated model of pitot-static tube and free-field pressure sensor. Based on the principle of dynamic pressure formation in the explosion field and the relationship between total pressure, static pressure and dynamic pressure, using computational fluid dynamics simulation, the aerodynamic characteristics of the sensor are explored, the structural dimensions of the sensor and the installation positions of the sensitive elements are determined. In view of the special environment of the explosion field, a dynamic pressure test system is built, 10kg, 20kg and 30kg cylindrical TNT explosion experiments are completed, the dynamic pressure signal processing methods are proposed and the complete dynamic pressure waveforms are obtained. The final results show that the sensor can effectively measure the dynamic pressure signal, which is essential to improve the dynamic pressure measurement capability and promote the development of new high-energy warheads.