Somnath Sarkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Somnath Sarkar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ariel Bulua Bourla
Flatiron Health, New York, NY
2 shared publications - Blythe Adamson
Flatiron Health, New York, USA
2 shared publications Elizabeth M. Sweeney
2 shared publicationsSandra D. Griffith
2 shared publications- Xinran Ma
Flatiron Health, Inc., Seattle, WA
2 shared publications - Atanu Roy
Department of Pediatric Medicine, Medical College and Hospital, Kolkata, West Bengal, India
1 shared publication
Latest Publications
- Open Access
- 19 December 2021
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 31 (1)
Cover Image, Volume 31, Issue 1
- 19 December 2021
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 31 (1)
Open AccessCover Image, Volume 31, Issue 1
- Open Access
- 5 July 2021
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 31 (1) , 46-54
Differential frequency in imaging‐based outcome measurement: Bias in real‐world oncology comparative‐effectiveness studies
Background: Comparative‐effectiveness studies using real‐world data (RWD) can be susceptible to surveillance bias. In solid tumor oncology studies, analyses of endpoints such as progression‐free survival (PFS) are based on progression events detected by imaging assessments. This study aimed to evaluate the potential bias introduced by differential imaging assessment frequency when using electronic health record (EHR)‐derived data to investigate the comparative effectiveness of cancer therapies.Methods: Using a nationwide de‐identified EHR‐derived database, we first analyzed imaging assessment frequency patterns in patients diagnosed with advanced non‐small cell lung cancer (aNSCLC). We used those RWD inputs to develop a discrete event simulation model of two treatments where disease progression was the outcome and PFS was the endpoint. Using this model, we induced bias with differential imaging assessment timing and quantified its effect on observed versus true treatment effectiveness. We assessed percent bias in the estimated hazard ratio (HR).Results: The frequency of assessments differed by cancer treatment types. In simulated comparative‐effectiveness studies, PFS HRs estimated using real‐world imaging assessment frequencies differed from the true HR by less than 10% in all scenarios (range: 0.4% to −9.6%). The greatest risk of biased effect estimates was found comparing treatments with widely different imaging frequencies, most exaggerated in disease settings where time to progression is very short.Conclusions: This study provided evidence that the frequency of imaging assessments to detect disease progression can differ by treatment type in real‐world patients with cancer and may induce some bias in comparative‐effectiveness studies in some situations.
- 5 July 2021
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 31 (1) , 46-54
Open AccessDifferential frequency in imaging‐based outcome measurement: Bias in real‐world oncology comparative‐effectiveness studies
Background: Comparative‐effectiveness studies using real‐world data (RWD) can be susceptible to surveillance bias. In solid tumor oncology studies, analyses of endpoints such as progression‐free survival (PFS) are based on progression events detected by imaging assessments. This study aimed to evaluate the potential bias introduced by differential imaging assessment frequency when using electronic health record (EHR)‐derived data to investigate the comparative effectiveness of cancer therapies.Methods: Using a nationwide de‐identified EHR‐derived database, we first analyzed imaging assessment frequency patterns in patients diagnosed with advanced non‐small cell lung cancer (aNSCLC). We used those RWD inputs to develop a discrete event simulation model of two treatments where disease progression was the outcome and PFS was the endpoint. Using this model, we induced bias with differential imaging assessment timing and quantified its effect on observed versus true treatment effectiveness. We assessed percent bias in the estimated hazard ratio (HR).Results: The frequency of assessments differed by cancer treatment types. In simulated comparative‐effectiveness studies, PFS HRs estimated using real‐world imaging assessment frequencies differed from the true HR by less than 10% in all scenarios (range: 0.4% to −9.6%). The greatest risk of biased effect estimates was found comparing treatments with widely different imaging frequencies, most exaggerated in disease settings where time to progression is very short.Conclusions: This study provided evidence that the frequency of imaging assessments to detect disease progression can differ by treatment type in real‐world patients with cancer and may induce some bias in comparative‐effectiveness studies in some situations.
- Open Access
- 20 June 2016
- Published by Akshantala Enterprises Private Limited in Journal of Evolution of Medical and Dental Sciences
- Vol. 5 (49) , 3168-3172
A REVIEW OF OCULAR FUNGAL INFECTIONS OTHER THAN KERATOMYCOSIS: THE GLOBAL AND INDIAN SCENARIO
- 20 June 2016
- Published by Akshantala Enterprises Private Limited in Journal of Evolution of Medical and Dental Sciences
- Vol. 5 (49) , 3168-3172
Open AccessA REVIEW OF OCULAR FUNGAL INFECTIONS OTHER THAN KERATOMYCOSIS: THE GLOBAL AND INDIAN SCENARIO