Josefin Ammon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Josefin Ammon has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Reinhard Loose
Paracelsus Medizinische Privatuniversität
2 shared publications- Barbara Schmid
Department of Neurology, Nuremberg Hospital Campus South, Paracelsus Medical University (PMU), Breslauer Str. 201, 90471 Nuremberg, Germany
1 shared publication Birgit Sabine Müller
Institute of Medical Physics, Klinikum Nurnberg, Paracelsus Medical University, Nurnberg, Germany
1 shared publication- Clemens Huettenbrink
Department of Urology, Nuremberg General Hospital, Paracelsus Medical University, 90419 Nuremberg, Germany
1 shared publication Eugenia Rerich
Institute of Medical Physics, Klinikum Nurnberg, Paracelsus Medical University, Nurnberg, Germany
1 shared publication- Florian A. Distler
Department of Urology, Nuremberg General Hospital, Paracelsus Medical University, 90419 Nuremberg, Germany
1 shared publication
Latest Publications
- Open Access
- 28 February 2026
- Published by MDPI AG in Brain Sciences
- Vol. 16 (3) , 279
Establishing a Sex-Specific Cut-Off for Temporal Bone Thickness in Transcranial Color-Coded Duplex Sonography
Background/Objectives: The aim of this study was to identify predictors of temporal window failure (TWF) in transcranial color-coded duplex sonography (TCCS) based on demographical and computed tomography (CT)-based parameters such as temporal bone thickness (TBT), and to define sex-specific thresholds for predicting TWF. Methods: We retrospectively analyzed a series of adult patients who underwent cranial CT and TCCS. Bitemporal TBT was measured in nine standardized regions on CT, and mean TBT per side was calculated. Temporal bone window (TBW) quality was graded with two semiquantitative TCCS scores assessing the visibility of the middle cerebral artery (MCA), contralateral temporal bone, mesencephalon, and ipsilateral sphenoid bone. Associations between TBT, sex, age, and TBW visibility were analyzed by correlation, chi-square tests, and logistic regression. Results: 200 patients (102 men, 98 women; mean age 68 ± 16 years) were enrolled. Mean TBT was 3.1 ± 0.7 mm (right) and 3.2 ± 0.7 mm (left). TBT correlated weakly with age (r = 0.15–0.18, p < 0.05) and was higher in women (p < 0.05). Age and sex influenced TBW visibility (p < 0.05) with small effect sizes. Increased TBT strongly predicted poor TBW (β ≈ –1.7, p < 0.001). Optimal TBT cut-offs predicting adequate TBW were 3.8 mm (men) and 3.3 mm (women), maximizing specificity (men: 0.95, women: 0.85) and negative predictive value (men: 0.87, women: 0.66). Conclusions: Advanced age and female sex were both associated with TWF. CT-assessed TBT represents a robust predictor of TCCS feasibility. Implementation of sex-specific TBT threshold values may facilitate patient pre-selection and improve procedural efficiency in neurosonographic diagnostics.
- 28 February 2026
- Published by MDPI AG in Brain Sciences
- Vol. 16 (3) , 279
Open AccessEstablishing a Sex-Specific Cut-Off for Temporal Bone Thickness in Transcranial Color-Coded Duplex Sonography
Background/Objectives: The aim of this study was to identify predictors of temporal window failure (TWF) in transcranial color-coded duplex sonography (TCCS) based on demographical and computed tomography (CT)-based parameters such as temporal bone thickness (TBT), and to define sex-specific thresholds for predicting TWF. Methods: We retrospectively analyzed a series of adult patients who underwent cranial CT and TCCS. Bitemporal TBT was measured in nine standardized regions on CT, and mean TBT per side was calculated. Temporal bone window (TBW) quality was graded with two semiquantitative TCCS scores assessing the visibility of the middle cerebral artery (MCA), contralateral temporal bone, mesencephalon, and ipsilateral sphenoid bone. Associations between TBT, sex, age, and TBW visibility were analyzed by correlation, chi-square tests, and logistic regression. Results: 200 patients (102 men, 98 women; mean age 68 ± 16 years) were enrolled. Mean TBT was 3.1 ± 0.7 mm (right) and 3.2 ± 0.7 mm (left). TBT correlated weakly with age (r = 0.15–0.18, p < 0.05) and was higher in women (p < 0.05). Age and sex influenced TBW visibility (p < 0.05) with small effect sizes. Increased TBT strongly predicted poor TBW (β ≈ –1.7, p < 0.001). Optimal TBT cut-offs predicting adequate TBW were 3.8 mm (men) and 3.3 mm (women), maximizing specificity (men: 0.95, women: 0.85) and negative predictive value (men: 0.87, women: 0.66). Conclusions: Advanced age and female sex were both associated with TWF. CT-assessed TBT represents a robust predictor of TCCS feasibility. Implementation of sex-specific TBT threshold values may facilitate patient pre-selection and improve procedural efficiency in neurosonographic diagnostics.
- 26 September 2025
- Published by Springer Nature
- p. 357-361
Strahlenschutz
- Open Access
- 7 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 643
Personalized Prediction of Patient Radiation Exposure for Therapy of Urolithiasis: An Application and Comparison of Six Machine Learning Algorithms
The prediction of radiation exposure is an important tool for the choice of therapy modality and becomes, as a component of patient-informed consent, increasingly important for both surgeon and patient. The final goal is the implementation of a trained and tested machine learning model in a real-time computer system allowing the surgeon and patient to better assess patient’s personal radiation risk. In summary, 995 patients with ureterorenoscopy over a period from May 2016 to December 2019 were included. According to the suggestions based on actual literature evidence, dose area product (DAP) was categorized into ‘low doses’ ≤ 2.8 Gy·cm2 and ‘high doses’ > 2.8 Gy·cm2 for ureterorenoscopy (URS). To forecast the level of radiation exposure during treatment, six different machine learning models were trained, and 10-fold crossvalidated and their model performances evaluated in training and independent test samples. The negative predictive value for low DAP during ureterorenoscopy was 94% (95% CI: 92–96%). Factors influencing the radiation exposure were: age (p = 0.0002), gender (p = 0.011), weight (p < 0.0001), stone size (p < 0.000001), surgeon experience (p = 0.039), number of stones (p = 0.0007), stone density (p = 0.023), use of flexible endoscope (p < 0.0001) and preoperative stone position (p < 0.00001). The machine learning algorithm identified a subgroup of patients of 81% of the total sample, for which highly accurate predictions (94%) were possible allowing the surgeon to assess patient’s personal radiation risk. Patients without prediction (19%), the medical expert can make decisions as usual. Next step will be the implementation of the trained model in real-time computer systems for clinical decision processes in daily practice.
- 7 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 643
Open AccessPersonalized Prediction of Patient Radiation Exposure for Therapy of Urolithiasis: An Application and Comparison of Six Machine Learning Algorithms
The prediction of radiation exposure is an important tool for the choice of therapy modality and becomes, as a component of patient-informed consent, increasingly important for both surgeon and patient. The final goal is the implementation of a trained and tested machine learning model in a real-time computer system allowing the surgeon and patient to better assess patient’s personal radiation risk. In summary, 995 patients with ureterorenoscopy over a period from May 2016 to December 2019 were included. According to the suggestions based on actual literature evidence, dose area product (DAP) was categorized into ‘low doses’ ≤ 2.8 Gy·cm2 and ‘high doses’ > 2.8 Gy·cm2 for ureterorenoscopy (URS). To forecast the level of radiation exposure during treatment, six different machine learning models were trained, and 10-fold crossvalidated and their model performances evaluated in training and independent test samples. The negative predictive value for low DAP during ureterorenoscopy was 94% (95% CI: 92–96%). Factors influencing the radiation exposure were: age (p = 0.0002), gender (p = 0.011), weight (p < 0.0001), stone size (p < 0.000001), surgeon experience (p = 0.039), number of stones (p = 0.0007), stone density (p = 0.023), use of flexible endoscope (p < 0.0001) and preoperative stone position (p < 0.00001). The machine learning algorithm identified a subgroup of patients of 81% of the total sample, for which highly accurate predictions (94%) were possible allowing the surgeon to assess patient’s personal radiation risk. Patients without prediction (19%), the medical expert can make decisions as usual. Next step will be the implementation of the trained model in real-time computer systems for clinical decision processes in daily practice.
- 22 November 2022
- Published by Springer Nature in Die Radiologie
- Vol. 62 (12) , 1079-1088
Strahlenschutz bei fluoroskopischen Interventionen
- 22 November 2022
- Published by Springer Nature in Die Radiologie
- Vol. 62 (12) , 1079-1088
Strahlenschutz bei fluoroskopischen Interventionen
- 1 January 2022
- Published by Springer Nature
- p. 1-5
Strahlenschutz
- 21 December 2021
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 194 (04) , 400-408
Handling of Incidents in the Clinical Application of Ionizing Radiation in Diagnostic and Interventional Radiology – a Multi-center Study
Purpose According to the German legislation and regulation of radiation protection, i. e. Strahlenschutzgesetz und Strahlenschutzverordnung (StrlSchG and StrlSchV), which came into force on 31st December 2018, significant unintended or accidential exposures have to be reported to the competent authority. Furthermore, facilities have to implement measures to prevent and to recognize unintended or accidental exposures as well as to reduce their consequences. We developed a process to register incidents and tested its application in the framework of a multi-center-study. Materials and Methods Over a period of 12 months, 16 institutions for x-ray diagnostics and interventions, documented their incidents. Documentation of the incidents was conducted using the software CIRSrad, which was developed, released for testing purposes and implemented in the frame of the study. Reporting criteria of the project were selected to be more sensitive compared to the legal criteria specifying “significant incidents”. Reported incidents were evaluated after four, eight, and twelve months. Finally, all participating institutions were interviewed on their experience with the software and the correlated effort. Results The rate of reported incidents varied between institutions as well as between modalities. The majority of incidents were reported in conventional x-ray imaging, followed by computed tomography and therapeutic interventions. Incidents were attributed to several different causes, amongst others to the technical setup and patient positioning (19 %) and patient movement or insufficient cooperativeness of the patient (18 %). Most incidents were below corresponding thresholds stated in StrlSchV. The workload for documenting the incidents was rated as appropriate. Conclusion It is possible to monitor and handle incidents complient with legal requirements with an acceptable effort. The number of reported incidents can be increased by frequent trainings on the detection and the processing workflow, on the software and legal regulation as well as by a transparent error handling within the institution. Key Points: Citation Format Received: 28 March 2021 Accepted: 30 September 2021 Publication Date: 21 December 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 21 December 2021
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 194 (04) , 400-408
Handling of Incidents in the Clinical Application of Ionizing Radiation in Diagnostic and Interventional Radiology – a Multi-center Study
Purpose According to the German legislation and regulation of radiation protection, i. e. Strahlenschutzgesetz und Strahlenschutzverordnung (StrlSchG and StrlSchV), which came into force on 31st December 2018, significant unintended or accidential exposures have to be reported to the competent authority. Furthermore, facilities have to implement measures to prevent and to recognize unintended or accidental exposures as well as to reduce their consequences. We developed a process to register incidents and tested its application in the framework of a multi-center-study. Materials and Methods Over a period of 12 months, 16 institutions for x-ray diagnostics and interventions, documented their incidents. Documentation of the incidents was conducted using the software CIRSrad, which was developed, released for testing purposes and implemented in the frame of the study. Reporting criteria of the project were selected to be more sensitive compared to the legal criteria specifying “significant incidents”. Reported incidents were evaluated after four, eight, and twelve months. Finally, all participating institutions were interviewed on their experience with the software and the correlated effort. Results The rate of reported incidents varied between institutions as well as between modalities. The majority of incidents were reported in conventional x-ray imaging, followed by computed tomography and therapeutic interventions. Incidents were attributed to several different causes, amongst others to the technical setup and patient positioning (19 %) and patient movement or insufficient cooperativeness of the patient (18 %). Most incidents were below corresponding thresholds stated in StrlSchV. The workload for documenting the incidents was rated as appropriate. Conclusion It is possible to monitor and handle incidents complient with legal requirements with an acceptable effort. The number of reported incidents can be increased by frequent trainings on the detection and the processing workflow, on the software and legal regulation as well as by a transparent error handling within the institution. Key Points: Citation Format Received: 28 March 2021 Accepted: 30 September 2021 Publication Date: 21 December 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany