JDJohannes Hugo Decker

Johannes Hugo Decker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Johannes Hugo Decker has a total of 69 co-authors. Here are the top co-authors by number of shared publications:

  • Tim Sprenger

    2 shared publications
  • Akshay Chaudhari

    Department of Radiology, Stanford University School of Medicine, Palo Alto, CA, USA

    1 shared publication
  • Alec Schielke

    Department of Integrated Primary Care, VA Palo Alto, Palo Alto, CA, USA

    1 shared publication
  • Alexander T. Mazal

    From Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University, Stanford, CA, USA (J.H.D., A.T.M.,A.B., N.F., G.Z.); MR Applied Science Laboratory Europe, GE Healthcare, Stockholm, Sweden (T.M.); Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden (T.M., S.S.)

    1 shared publication
  • Amy Bui

    From Division of Neuroimaging and Neurointervention, Department of Radiology, Stanford University, Stanford, CA, USA (J.H.D., A.T.M.,A.B., N.F., G.Z.); MR Applied Science Laboratory Europe, GE Healthcare, Stockholm, Sweden (T.M.); Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden (T.M., S.S.)

    1 shared publication
  • Anand Veeravagu

    Department of Neurosurgery, Stanford University School of Medicine, Palo Alto, CA, USA

    1 shared publication

Latest Publications

  • Open Access

    MRI-derived spatial morphometrics of calvarial diploic venous lakes for designing next-generation cerebrospinal fluid diversionary devices

    by Christopher J. Shin, Nicholas S. Bates, Johannes H. Decker, Tarik F. Massoud

  • Open Access

    Patterns of Muscle Health in Single- and Multi-Site Chronic Pain: A UK Biobank Normative Modeling Study

    by Merve Kaptan, Yiyu Wang, Augustijn de Boer, Ananya Goyal, Skylar Holmes, Kerem Ozkan, Sandrine Bédard, Teresa Indriolo, Christine S W Law, Dario Pfyffer, et al.

    Background: Chronic pain is associated with impaired muscle health, but whether these changes reflect site-specific factors, broader systemic factors, or both remains unclear. The purpose of this study is to determine whether normative markers of muscle health derived from MRI show site-specific patterns in chronic pain. Methods: UK Biobank participants who underwent whole-body MRI from 2006 to 2010 were included in this retrospective cross-sectional study. The MuscleMap Toolbox quantified volume and intramuscular fat (IMF) in 42 muscles of the abdomen, pelvis, and thigh. Normative models trained on a no pain group generated muscle-specific deviations from normal (i.e., Z-scores) for single- and multi-site chronic and acute pain. Results: Of 17,843 participants, the primary site-specific analysis included 9,704 no pain, 885 single-site chronic back pain (CBP), 438 single-site chronic hip pain (CHP), and 1,315 single-site chronic knee pain (CKP) participants (n=12,342; mean age 63.7±7.5 years; 52.7% female). Additional analyses included single-site chronic neck/shoulder pain, acute pain, and multi-site chronic pain groups. In CBP, deviations were localized to abdominal muscles, with decreased volume in 6/8 and increased IMF in 6/8. In CHP, deviations were broad, with decreased volume in 3/8 of the abdominal and 14/26 of the thigh muscles, and increased IMF in 6/8 of the abdominal, 5/8 of the pelvic, and 4/26 of the thigh muscles. In CKP, deviations were localized to thigh muscles, with decreased volume in 8/26 and increased IMF in 6/26. Acute pain groups showed no significant differences except for decreased volume in one thigh muscle in acute knee pain. With each additional chronic pain site, volume decreased (β=−.078;IQR:−0.100−0.051), and IMF increased (β=.085;IQR:0.066−0.101). Combined Z-scores classified chronic pain groups better than chance (accuracy: 48.6%;p<.001), but not acute pain groups (accuracy: 39.0%;p=.20). Conclusions: Whole-body MRI combined with AI-driven muscle segmentation and normative modeling revealed site-specific patterns of muscle health in single-site chronic pain.

  • A Comprehensive 2.5-Minute Brain MRI Protocol in the Pediatric Emergency Department: Diagnostic Evaluation of the Multicontrast NeuroMix Sequence

    by Mateus A. Esmeraldo, Bruno P. Soares, Eduardo P. Reis, Hisham Dahmoush, Anish Bhandari, Andrew W. Campion, Tim Sprenger, Stefan Skare, Greg Zaharchuk, Johannes H. Decker

    Prolonged acquisition times and motion artifacts limit the use of MRI in the pediatric emergency department, frequently necessitating sedation and reducing workflow efficiency, or prompting the use of CT with associated ionizing radiation. Recent MRI advances enable fast, comprehensive neuroimaging without radiation exposure. This study evaluates the diagnostic interchangeability of a fast 2.5-minute MRI multicontrast sequence (NeuroMix) with a standard MRI protocol for detecting clinically relevant intracranial findings in the pediatric emergency department. We retrospectively identified sequential pediatric patients who underwent both a standard pediatric emergency department MRI protocol and NeuroMix over a one-year period. A finding-enriched cohort of 100 studies was constructed (44 positives and 56 controls). Three radiologists independently reviewed NeuroMix and standard protocol imaging sets in randomized batches. Diagnostic interchangeability was assessed using an agreement-based mixed-effects modeling approach using a noninferiority threshold of 10%. Acquisition times, examination completeness, artifact prevalence, interreader agreement, and diagnostic performance metrics were compared between protocols, in accordance with STARD. NeuroMix demonstrated diagnostic interchangeability with the standard pediatric emergency MRI protocol for detection of clinically relevant findings, with an interchangeability estimate of -3.1% (95% CI, -6.6% to +0.3%), remaining within the noninferiority margin. Overall diagnostic accuracy was identical for NeuroMix and standard imaging (87.7%). Interreader agreement for detection of clinically relevant findings was substantial for both NeuroMix (κ = 0.65) and the standard protocol (κ = 0.73). Mean acquisition time was markedly shorter for NeuroMix when compared with the standard protocol (median 2.67 minutes vs 15.26 minutes, p < 0.001). Moderate to severe artifacts and repeat sequence acquisitions occurred less frequently with NeuroMix. A 2.5-minute NeuroMix-based MRI protocol demonstrated diagnostic interchangeability with a standard pediatric emergency MRI protocol for clinically relevant intracranial findings with substantially reduced acquisition time and imaging artifacts. These results support NeuroMix as a fast, radiation-free approach that may serve, depending on the clinical scenario, as a supplementary or alternative neuroimaging protocol in pediatric emergency care.

  • Neurodegenerative Disorders

    by Johannes H. Decker, Max Wintermark, Michael Zeineh

  • NeuroMix with MRA: A Fast MR Protocol to Reduce Head and Neck CTA for Patients with Acute Neurologic Presentations

    by Johannes H. Decker, Alexander T. Mazal, Amy Bui, Tim Sprenger, Stefan Skare, Nancy Fischbein, Greg Zaharchuk

    BACKGROUND AND PURPOSE: Overuse of computed tomography (CT)-based cerebrovascular imaging in the emergency department (ED) and inpatient settings, notably CT angiography of the head and neck (CTAHN) for minor and non-focal neurological presentations, stresses imaging services and exposes patients to radiation and contrast. Furthermore, such CT-based imaging is often insufficient for definitive diagnosis, necessitating additional MR imaging. Recent advances in fast MRI may allow for timely assessment and reduced need for CTAHN in select populations. MATERIALS AND METHODS: We identified inpatients or ED patients who underwent CTAHN (including non-contrast and post-contrast CTH, with or without CT perfusion [CTP] imaging) followed within 24 hours by a 3T MRI study that included NeuroMix (an unenhanced 2.5 min multi-contrast sequence) and intracranial time-of-flight MR angiography (MRA; a 5 min sequence) during a 9-month period (April to December 2022). Cases were classified by 4 radiologists in consensus as to whether NeuroMix and NeuroMix+MRA detected equivalent findings, detected unique findings, or missed findings relative to CTAHN. RESULTS: 174 cases (mean age 67±16 yrs; 56% female) met the inclusion criteria. NeuroMix alone and NeuroMix+MRA protocols were determined to be equivalent or better compared to CTAHN in 71% and 95% of patients, respectively. NeuroMix always provided equivalent or better assessment of the brain parenchyma, with unique findings on NeuroMix and NeuroMix+MRA in 35% and 36% of cases, respectively, most commonly acute infarction or multiple microhemorrhages. In 8/174 cases (5%), CTAHN identified vascular abnormalities not seen on the NeuroMix+MRA protocol due to CTAHN’s wider coverage of the cervical arteries. CONCLUSIONS: A fast MR imaging protocol consisting of NeuroMix+MRA provided equivalent or better information compared to CTAHN in 95% of cases in our population of patients with an acute neurological presentation. The findings provide a deeper understanding of the benefits and challenges of a fast unenhanced MR-first approach with NeuroMix+MRA, which could be used to design prospective trials in select patient groups, with the potential to reduce radiation dose, mitigate adverse contrast-related patient and environmental effects, and lessen the burden on radiologists and healthcare systems. ABBREVIATIONS: CTAHN = CTA Head and Neck including non-contrast and delayed post-contrast CT Head with or without CT perfusion, NeuroMix = unenhanced multi-contrast MR brain sequence.


  • Automated Identification and Measurement Extraction of Pancreatic Cystic Lesions from Free-Text Radiology Reports Using Natural Language Processing

    by Rikiya Yamashita, Kristen Bird, Philip Yue-Cheng Cheung, Johannes Hugo Decker, Marta Nicole Flory, Daniel Goff, Linda Nayeli Morimoto, Andy Shon, Andrew Louis Wentland, Daniel L. Rubin, et al.

    “Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...