Satoshi Yasukochi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Satoshi Yasukochi has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Kisaburo Sakamoto
Department of Cardiovascular Surgery, Mt. Fuji Shizuoka Children’s Hospital , Shizuoka, 420-8660
3 shared publications - Ryo Inuzuka
University of Tokyo
3 shared publications - Masaaki Yamagishi
Kyoto Prefectural University of Medicine
2 shared publications - Akio Ikai
Department of Cardiovascular Surgery, Mt. Fuji Shizuoka Children’s Hospital , Shizuoka, Japan
1 shared publication - Atsuhito Takeda
Department of Pediatrics, Hokkaido University, Kita 15, Nishi 7, Sapporo 060-8638, Japan
1 shared publication - Atsuko Kato
Osaka University Graduate School of Medicine
1 shared publication
Latest Publications
- Open Access
- 3 December 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (12) , 387
Evaluation of the Efficacy and Accuracy of Super-Flexible Three-Dimensional Heart Models of Congenital Heart Disease Made via Stereolithography Printing and Vacuum Casting: A Multicenter Clinical Trial
Three-dimensional (3D) printing is an advanced technology for accurately understanding anatomy and supporting the successful surgical management of complex congenital heart disease (CHD). We aimed to evaluate whether our super-flexible 3D heart models could facilitate preoperative decision-making and surgical simulation for complex CHD. The super-flexible heart models were fabricated by stereolithography 3D printing of the internal and external contours of the heart from cardiac computed tomography (CT) data, followed by vacuum casting with a polyurethane material similar in elasticity to a child’s heart. Nineteen pediatric patients with complex CHD were enrolled (median age, 10 months). The primary endpoint was defined as the percentage of patients rated as “essential” on the surgeons’ postoperative 5-point Likert scale. The accuracy of the models was validated by a non-destructive method using industrial CT. The super-flexible heart models allowed detailed anatomical diagnosis and simulated surgery with incisions and sutures. Thirteen patients (68.4%) were classified as “essential” by the primary surgeons after surgery, with a 95% confidence interval of 43.4–87.4%, meeting the primary endpoint. The product error within 90% of the total external and internal surfaces was 0.54 ± 0.21 mm. The super-flexible 3D heart models are accurate, reliable, and useful tools to assist surgeons in decision-making and allow for preoperative simulation in CHD.
- 3 December 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (12) , 387
Open AccessEvaluation of the Efficacy and Accuracy of Super-Flexible Three-Dimensional Heart Models of Congenital Heart Disease Made via Stereolithography Printing and Vacuum Casting: A Multicenter Clinical Trial
Three-dimensional (3D) printing is an advanced technology for accurately understanding anatomy and supporting the successful surgical management of complex congenital heart disease (CHD). We aimed to evaluate whether our super-flexible 3D heart models could facilitate preoperative decision-making and surgical simulation for complex CHD. The super-flexible heart models were fabricated by stereolithography 3D printing of the internal and external contours of the heart from cardiac computed tomography (CT) data, followed by vacuum casting with a polyurethane material similar in elasticity to a child’s heart. Nineteen pediatric patients with complex CHD were enrolled (median age, 10 months). The primary endpoint was defined as the percentage of patients rated as “essential” on the surgeons’ postoperative 5-point Likert scale. The accuracy of the models was validated by a non-destructive method using industrial CT. The super-flexible heart models allowed detailed anatomical diagnosis and simulated surgery with incisions and sutures. Thirteen patients (68.4%) were classified as “essential” by the primary surgeons after surgery, with a 95% confidence interval of 43.4–87.4%, meeting the primary endpoint. The product error within 90% of the total external and internal surfaces was 0.54 ± 0.21 mm. The super-flexible 3D heart models are accurate, reliable, and useful tools to assist surgeons in decision-making and allow for preoperative simulation in CHD.
- 30 October 2024
- Published by Springer Nature in Heart and Vessels
- Vol. 40 (5) , 414-425
Normal values and distribution of ventricular global longitudinal strain in 513 healthy fetuses measured by two-dimensional speckle-tracking echocardiography: a multi-institutional cohort study
This study aimed to determine the normal reference values and distribution of global longitudinal strain (GLS) in the right and left ventricles of healthy Japanese fetuses during pregnancy. This multi-institutional cohort study included healthy Japanese fetuses during normal pregnancies without maternal or fetal complications between 18 and 40 weeks of gestation. Two-dimensional fetal echocardiographic images of the four-chamber view with a high frame rate were acquired and stored as DICOM clips. Data were collected and analyzed in a central laboratory to measure the left ventricular (LV) and right ventricular (RV) GLS using two-dimensional speckle tracking. In total, 513 fetuses were enrolled. The mean LV-GLS and RV-GLS were − 24.3% ± 3.5% and − 23.5% ± 3.7%, respectively. The magnitude of the GLS, with normal limits in both ventricles, decreased with advancing gestation. LV values were r = 0.34 (95% confidence interval, 0.27–0.42) and p < 0.0001; RV values were r = 0.33 (95% confidence interval, 0.25–0.41) and p < 0.0001. The normal values of healthy Japanese fetuses in healthy pregnancies is the first to be established by the large-scale, multi-institutional cohort study as LV-GLS of 24.3% ± 3.5% and RV-GLS of − 23.5% ± 3.7%, respectively. This can serve as a basic reference for assessing the cardiac functions in Japanese fetuses with various heart diseases.
- 30 October 2024
- Published by Springer Nature in Heart and Vessels
- Vol. 40 (5) , 414-425
Normal values and distribution of ventricular global longitudinal strain in 513 healthy fetuses measured by two-dimensional speckle-tracking echocardiography: a multi-institutional cohort study
This study aimed to determine the normal reference values and distribution of global longitudinal strain (GLS) in the right and left ventricles of healthy Japanese fetuses during pregnancy. This multi-institutional cohort study included healthy Japanese fetuses during normal pregnancies without maternal or fetal complications between 18 and 40 weeks of gestation. Two-dimensional fetal echocardiographic images of the four-chamber view with a high frame rate were acquired and stored as DICOM clips. Data were collected and analyzed in a central laboratory to measure the left ventricular (LV) and right ventricular (RV) GLS using two-dimensional speckle tracking. In total, 513 fetuses were enrolled. The mean LV-GLS and RV-GLS were − 24.3% ± 3.5% and − 23.5% ± 3.7%, respectively. The magnitude of the GLS, with normal limits in both ventricles, decreased with advancing gestation. LV values were r = 0.34 (95% confidence interval, 0.27–0.42) and p < 0.0001; RV values were r = 0.33 (95% confidence interval, 0.25–0.41) and p < 0.0001. The normal values of healthy Japanese fetuses in healthy pregnancies is the first to be established by the large-scale, multi-institutional cohort study as LV-GLS of 24.3% ± 3.5% and RV-GLS of − 23.5% ± 3.7%, respectively. This can serve as a basic reference for assessing the cardiac functions in Japanese fetuses with various heart diseases.
- 21 December 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 144 (25) , 2043-2045
Incidence and Expected Probability of Liver Cirrhosis and Hepatocellular Carcinoma After Fontan Operation
- 21 December 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 144 (25) , 2043-2045
Incidence and Expected Probability of Liver Cirrhosis and Hepatocellular Carcinoma After Fontan Operation
- Open Access
- 10 March 2021
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 3 (3) , 153-160
Pediatric Medical Devices ― Survey of Pediatric Cardiologists and Cardiovascular Surgeons in Japan ―
Background:In Japan, the choice of pediatric medical devices is limited because of 2 “device lag” problems: Japan lags behind the USA and Europe in device development, and development of pediatric devices lags behind that of adult devices. We aimed to identify the problems with and impediments to pediatric medical device development as recognized by pediatric physicians in Japan.Methods and Results:A voluntary survey of pediatric medical devices for all council members of the Japanese Society of Pediatric Cardiology and Cardiac Surgery was conducted in 2019. The response rate was 47.1% (154/327). The respondents were 115 pediatric cardiologists (74.7%) and 39 cardiovascular surgeons (25.3%). Approximately 90% believed that difficulties in development existed. Approximately 70% were dissatisfied with the pediatric medical devices currently available in Japan, which was a result of the unavailability of medical devices approved overseas, few types and sizes, and off-label use. Factors that hindered the development of pediatric medical devices included anatomical issues specific to children with congenital heart disease, as well as system issues such as lack of corporate profitability, development cost, and amount of time for development.Conclusions:Pediatric cardiologists and cardiovascular surgeons regard “device lag” and “off-label use” in Japan as important hindrances to the delivery of better medical care for pediatric patients with congenital heart disease.
- 10 March 2021
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 3 (3) , 153-160
Open AccessPediatric Medical Devices ― Survey of Pediatric Cardiologists and Cardiovascular Surgeons in Japan ―
Background:In Japan, the choice of pediatric medical devices is limited because of 2 “device lag” problems: Japan lags behind the USA and Europe in device development, and development of pediatric devices lags behind that of adult devices. We aimed to identify the problems with and impediments to pediatric medical device development as recognized by pediatric physicians in Japan.Methods and Results:A voluntary survey of pediatric medical devices for all council members of the Japanese Society of Pediatric Cardiology and Cardiac Surgery was conducted in 2019. The response rate was 47.1% (154/327). The respondents were 115 pediatric cardiologists (74.7%) and 39 cardiovascular surgeons (25.3%). Approximately 90% believed that difficulties in development existed. Approximately 70% were dissatisfied with the pediatric medical devices currently available in Japan, which was a result of the unavailability of medical devices approved overseas, few types and sizes, and off-label use. Factors that hindered the development of pediatric medical devices included anatomical issues specific to children with congenital heart disease, as well as system issues such as lack of corporate profitability, development cost, and amount of time for development.Conclusions:Pediatric cardiologists and cardiovascular surgeons regard “device lag” and “off-label use” in Japan as important hindrances to the delivery of better medical care for pediatric patients with congenital heart disease.
- Open Access
- 1 May 2019
- Published by The Japanese Society of Pediatric Cardiology and Cardiac Surgery in Pediatric Cardiology and Cardiac Surgery
- Vol. 35 (2) , 61-69
Training of Novice Pediatric Cardiac Surgeons in Japan: Report of Questionnaire
背景:日本小児循環器学会では外科系教育部会を設置し,次世代小児心臓外科医育成プロジェクトを立ち上げることとなった.方法:今回,プロジェクトの一環として我が国の小児心臓外科医の労働環境,修練状況等に関する情報を得るために,日本小児循環器学会の外科系会員を対象にアンケート調査を行った.2018年6月26日(火)~8月6日(火)の期間に,日本小児循環器学会正会員の心臓血管外科医師420名に対し匿名式によるWEBアンケートを依頼し,176名から回答が得られた(回答率42%).結果:小児心臓外科医の15%が月10回以上の当直を行っており,実に85%が法定労働時間の上限を超えていた.また,今回のアンケート結果から,小児心臓外科医の修練環境は「施設によって大きなばらつきがある」ということが確認された.外科医ひとりあたりの手術症例数にもばらつきが生じてしまい,十分な数の執刀経験が得られているとは言いがたく,過酷な労働環境も相まって,多くの外科医が不満と不安を抱えているのが現状であった.結語:「執刀症例の数や難易度等ある程度プログラム化された修練環境」,「出身大学や所属する医局に左右されない修練施設の運用」,「過酷な労働環境の改善」が必要であり,「オールジャパンで次世代を育てる」というシステムを構築していく必要がある.
- 1 May 2019
- Published by The Japanese Society of Pediatric Cardiology and Cardiac Surgery in Pediatric Cardiology and Cardiac Surgery
- Vol. 35 (2) , 61-69
Open AccessTraining of Novice Pediatric Cardiac Surgeons in Japan: Report of Questionnaire
背景:日本小児循環器学会では外科系教育部会を設置し,次世代小児心臓外科医育成プロジェクトを立ち上げることとなった.方法:今回,プロジェクトの一環として我が国の小児心臓外科医の労働環境,修練状況等に関する情報を得るために,日本小児循環器学会の外科系会員を対象にアンケート調査を行った.2018年6月26日(火)~8月6日(火)の期間に,日本小児循環器学会正会員の心臓血管外科医師420名に対し匿名式によるWEBアンケートを依頼し,176名から回答が得られた(回答率42%).結果:小児心臓外科医の15%が月10回以上の当直を行っており,実に85%が法定労働時間の上限を超えていた.また,今回のアンケート結果から,小児心臓外科医の修練環境は「施設によって大きなばらつきがある」ということが確認された.外科医ひとりあたりの手術症例数にもばらつきが生じてしまい,十分な数の執刀経験が得られているとは言いがたく,過酷な労働環境も相まって,多くの外科医が不満と不安を抱えているのが現状であった.結語:「執刀症例の数や難易度等ある程度プログラム化された修練環境」,「出身大学や所属する医局に左右されない修練施設の運用」,「過酷な労働環境の改善」が必要であり,「オールジャパンで次世代を育てる」というシステムを構築していく必要がある.
- 8 November 2014
- Published by Springer Nature
- p. 43-70
Assessment of Intracardiac Anatomy by Magnetic Resonance Imaging
- 8 November 2014
- Published by Springer Nature
- p. 43-70
Assessment of Intracardiac Anatomy by Magnetic Resonance Imaging
- Open Access
- 1 January 2014
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 78 (7) , 1710-1716
Current Trends in Use of Implantable Cardioverter Defibrillators and Cardiac Resynchronization Therapy With a Pacemaker or Defibrillator in Japanese Pediatric Patients
In Japan, the use of implantable cardioverter defibrillators (ICDs), cardiac resynchronization therapy with a biventricular pacemaker (CRTP) and CRT with a defibrillator (CRTD) in children has not been studied statistically, and dual-chamber (DDD) pacemakers are still used for pediatric CRT because of current government regulations. Data were obtained from 15 children's and 74 general hospitals through a questionnaire survey regarding the aforementioned therapies performed before 2012 in Japanese children (<16 years old). ICD, CRT with DDD, CRTP and CRTD were used in 64 (42%), 47 (31%), 34 (22%) and 7 (5%), respectively, of all cases reported (n=152). Among all CRTP and CRT-DDD cases (n=81), the use of DDD accounted for 41% in general hospitals vs. 89% in children's hospitals, and CRT-DDD and CRTP were effective in 67 cases (83%). Of 64 ICD cases, appropriate shocks were experienced in 28 cases (44%), and inappropriate shocks in 19 cases (29%). Additionally, data from the Japan Arrhythmia Device Industry Association obtained for overall device usage analysis revealed that CRTP was more commonly used in children than in adults. There is an increasing need for pediatric device therapy, especially CRTP. However, many children's hospitals were still using DDD pacemakers in 2012. Although the demand for device therapy in children may be small, it is indispensable in pediatric cardiology.
- 1 January 2014
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 78 (7) , 1710-1716
Open AccessCurrent Trends in Use of Implantable Cardioverter Defibrillators and Cardiac Resynchronization Therapy With a Pacemaker or Defibrillator in Japanese Pediatric Patients
In Japan, the use of implantable cardioverter defibrillators (ICDs), cardiac resynchronization therapy with a biventricular pacemaker (CRTP) and CRT with a defibrillator (CRTD) in children has not been studied statistically, and dual-chamber (DDD) pacemakers are still used for pediatric CRT because of current government regulations. Data were obtained from 15 children's and 74 general hospitals through a questionnaire survey regarding the aforementioned therapies performed before 2012 in Japanese children (<16 years old). ICD, CRT with DDD, CRTP and CRTD were used in 64 (42%), 47 (31%), 34 (22%) and 7 (5%), respectively, of all cases reported (n=152). Among all CRTP and CRT-DDD cases (n=81), the use of DDD accounted for 41% in general hospitals vs. 89% in children's hospitals, and CRT-DDD and CRTP were effective in 67 cases (83%). Of 64 ICD cases, appropriate shocks were experienced in 28 cases (44%), and inappropriate shocks in 19 cases (29%). Additionally, data from the Japan Arrhythmia Device Industry Association obtained for overall device usage analysis revealed that CRTP was more commonly used in children than in adults. There is an increasing need for pediatric device therapy, especially CRTP. However, many children's hospitals were still using DDD pacemakers in 2012. Although the demand for device therapy in children may be small, it is indispensable in pediatric cardiology.