Robert Hawes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Hawes has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
- Alan N. Barkun
Division of Gastroenterology, McGill University Health Center, McGill University, Montreal, Quebec, Canada
5 shared publications - Ji Young Bang
Digestive Health Institute, Orlando Health, Orlando, Florida, USA
5 shared publications - Shyam Varadarajulu
Digestive Health Institute, Orlando Health, Orlando, Florida, USA
5 shared publications Adam Slivka
Professor of Medicine School of Medicine Chief Division of Gastroenterology Western Reserve University University Hospitals of Cleveland Cleveland Hyderabad Beijing Ohio India
4 shared publicationsAjay Kumar
Professor of Medicine School of Medicine Chief Division of Gastroenterology Western Reserve University University Hospitals of Cleveland Cleveland Hyderabad Beijing Ohio India
4 shared publicationsAksel Kruse
Professor of Medicine School of Medicine Chief Division of Gastroenterology Western Reserve University University Hospitals of Cleveland Cleveland Hyderabad Beijing Ohio India
4 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 121 (11) , 2813-2816
Radiation Scatter at Fluoroscopy-Guided Endoscopic Procedures: Building Toward Further Optimization
INTRODUCTION: Exposure to ionizing radiation by endoscopy personnel during fluoroscopy-guided procedures remains a health hazard. We aimed to evaluate a novel lead flap-enhanced artificial intelligence-enabled fluoroscopy (LE-AIF) system to minimize radiation scatter. METHODS: We conducted prospective study of 218 patients who underwent fluoroscopy-guided endoscopic procedures using conventional AIF or LE-AIF systems. The primary outcome measure was comparison of radiation scatter to endoscopists. RESULTS: Radiation scatter to endoscopists and anesthesia personnel were significantly lower using LE-AIF. On linear regression analysis, conventional AIF and fluoroscopy duration were associated with radiation scatter. DISCUSSION: LE-AIF significantly reduced radiation scatter at endoscopic procedures.
- 26 June 2026
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 121 (11) , 2813-2816
Open AccessRadiation Scatter at Fluoroscopy-Guided Endoscopic Procedures: Building Toward Further Optimization
INTRODUCTION: Exposure to ionizing radiation by endoscopy personnel during fluoroscopy-guided procedures remains a health hazard. We aimed to evaluate a novel lead flap-enhanced artificial intelligence-enabled fluoroscopy (LE-AIF) system to minimize radiation scatter. METHODS: We conducted prospective study of 218 patients who underwent fluoroscopy-guided endoscopic procedures using conventional AIF or LE-AIF systems. The primary outcome measure was comparison of radiation scatter to endoscopists. RESULTS: Radiation scatter to endoscopists and anesthesia personnel were significantly lower using LE-AIF. On linear regression analysis, conventional AIF and fluoroscopy duration were associated with radiation scatter. DISCUSSION: LE-AIF significantly reduced radiation scatter at endoscopic procedures.
- Open Access
- 30 May 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (3) , 360-369
Peroral cholangioscopy: past, present and future
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold standard for the evaluation of biliary strictures and the management of bile duct stones. However, standard ERCP techniques sometimes fail for both indications. In such situations, peroral cholangioscopy (POCS), which allows direct visualization of the bile duct, can play a significant role in diagnosis and treatment. Direct visualization using POCS can help differentiate between malignant and benign conditions and is more accurate in defining the extent of cholangiocarcinoma. Furthermore, POCS enables visually guided biopsies. Certain types of difficult bile duct stones, such as impacted and intrahepatic stones, require POCS for visually guided lithotripsy. Recent advancements in POCS will broaden its applicability and improve its diagnostic utility. In this review, we provide perspectives on the past, present, and future of POCS.
- 30 May 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (3) , 360-369
Open AccessPeroral cholangioscopy: past, present and future
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold standard for the evaluation of biliary strictures and the management of bile duct stones. However, standard ERCP techniques sometimes fail for both indications. In such situations, peroral cholangioscopy (POCS), which allows direct visualization of the bile duct, can play a significant role in diagnosis and treatment. Direct visualization using POCS can help differentiate between malignant and benign conditions and is more accurate in defining the extent of cholangiocarcinoma. Furthermore, POCS enables visually guided biopsies. Certain types of difficult bile duct stones, such as impacted and intrahepatic stones, require POCS for visually guided lithotripsy. Recent advancements in POCS will broaden its applicability and improve its diagnostic utility. In this review, we provide perspectives on the past, present, and future of POCS.
- Open Access
- 21 November 2023
- Published by Wolters Kluwer Health in Journal of Clinical Gastroenterology
- Vol. 58 (8) , 830-835
Impact of Slim Linear Echoendoscope on the Practice of EUS
Background: Standard linear echoendoscopes have a large distal tip and bending radius, which can preclude adequate examination in some patients. Objective: We examined the impact of having available slim linear echoendoscopes (SLE) on our endoscopic ultrasound (EUS) practice. Materials and Methods: As a quality improvement measure, data on the need for the use of SLE were documented in 2000 consecutive procedures performed over a 10-month period from February to November 2022. When examination using a standard size echoendoscope failed due to technical limitations, the procedure was reattempted in the same session using a SLE. The main outcome was the impact of SLE, which was defined as the establishment of a new diagnosis or if findings altered treatment plan. Results: A complete EUS examination failed in 23 of 2000 procedures (1.15%, 95% CI, 0.73-1.72%) performed using standard size echoendoscope (14 male, median age 73 y [IQR 66 to 79]). The examination was technically successful when using SLE in 22 of 23 (95.6%) patients. SLE impacted clinical management in all 22 patients (100%) by establishing tissue diagnosis in 19 and/or altering subsequent treatment plan in 5. Adverse event of transient hypoxia was observed in one patient (4.3%). Conclusions: A very experienced EUS team required SLE in 1.1% of consecutive examinations. Our findings suggest that when used, 95% of patients benefitted as it had a significant impact on their clinical management.
- 21 November 2023
- Published by Wolters Kluwer Health in Journal of Clinical Gastroenterology
- Vol. 58 (8) , 830-835
Open AccessImpact of Slim Linear Echoendoscope on the Practice of EUS
Background: Standard linear echoendoscopes have a large distal tip and bending radius, which can preclude adequate examination in some patients. Objective: We examined the impact of having available slim linear echoendoscopes (SLE) on our endoscopic ultrasound (EUS) practice. Materials and Methods: As a quality improvement measure, data on the need for the use of SLE were documented in 2000 consecutive procedures performed over a 10-month period from February to November 2022. When examination using a standard size echoendoscope failed due to technical limitations, the procedure was reattempted in the same session using a SLE. The main outcome was the impact of SLE, which was defined as the establishment of a new diagnosis or if findings altered treatment plan. Results: A complete EUS examination failed in 23 of 2000 procedures (1.15%, 95% CI, 0.73-1.72%) performed using standard size echoendoscope (14 male, median age 73 y [IQR 66 to 79]). The examination was technically successful when using SLE in 22 of 23 (95.6%) patients. SLE impacted clinical management in all 22 patients (100%) by establishing tissue diagnosis in 19 and/or altering subsequent treatment plan in 5. Adverse event of transient hypoxia was observed in one patient (4.3%). Conclusions: A very experienced EUS team required SLE in 1.1% of consecutive examinations. Our findings suggest that when used, 95% of patients benefitted as it had a significant impact on their clinical management.
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S25
Description of technique for EUS-guided tissue acquisition in pancreatic cancer for comprehensive molecular profiling: Results of a randomized trial
Aims As theoretically actionable genomic lesions are found in 50% of pancreatic cancers which can impact clinical management in up to 30% of patients, there is increased focus on molecular profiling. Although EUS-FNB is an established method for pathological diagnosis in pancreatic cancers, technique for comprehensive molecular profiling (CMP) has not been described. Methods Patients with pancreatic adenocarcinoma on ROSE at EUS were randomized to 2 or 3 dedicated FNB passes for CMP. Tissue was procured using 22G Franseen needle adopting fanning technique and stylet-retraction maneuver. Genomic DNA and total RNA were extracted from cell blocks. Next-generation sequencing was performed for analyzing 69 gene DNA mutations and 53 RNA somatic oncogenic gene fusions. Main outcome measure was specimens in which adequate DNA and RNA were extracted for CMP. Results 33 patients were randomized to 2(n=17) or 3(n=16) FNB passes. While sufficient DNA was extracted from all 33 cell blocks, adequate RNA was extracted from 93.8% in 3-pass vs. 94.1% in 2-pass cohort (p=0.99). There was no significant difference in mean DNA concentration (2-pass 10.7[SD 7.1] vs. 3-pass 7.9ng/ul[SD 4.4]; p=0.19) or RNA (2-pass 37.1[SD 26.5] vs. 3-pass 28.9ug/ul[SD 13.2]; p=0.29) between groups. While somatic oncogene RNA fusion (LDAH-ETV1) predictive of metastatic disease was identified in 1, DNA mutations were identified in all 33 pts (inc. 1 BRCA1 for Oxaliplatin based chemotherapy) ([Table 1]). Conclusions Specimens of adequate quantity and of high quality for CMP in pancreatic cancer can be procured in nearly 95% of patients by performing 2 dedicated passes using 22G Franseen needle, adopting fanning maneuver and stylet-retraction technique. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S25
Description of technique for EUS-guided tissue acquisition in pancreatic cancer for comprehensive molecular profiling: Results of a randomized trial
Aims As theoretically actionable genomic lesions are found in 50% of pancreatic cancers which can impact clinical management in up to 30% of patients, there is increased focus on molecular profiling. Although EUS-FNB is an established method for pathological diagnosis in pancreatic cancers, technique for comprehensive molecular profiling (CMP) has not been described. Methods Patients with pancreatic adenocarcinoma on ROSE at EUS were randomized to 2 or 3 dedicated FNB passes for CMP. Tissue was procured using 22G Franseen needle adopting fanning technique and stylet-retraction maneuver. Genomic DNA and total RNA were extracted from cell blocks. Next-generation sequencing was performed for analyzing 69 gene DNA mutations and 53 RNA somatic oncogenic gene fusions. Main outcome measure was specimens in which adequate DNA and RNA were extracted for CMP. Results 33 patients were randomized to 2(n=17) or 3(n=16) FNB passes. While sufficient DNA was extracted from all 33 cell blocks, adequate RNA was extracted from 93.8% in 3-pass vs. 94.1% in 2-pass cohort (p=0.99). There was no significant difference in mean DNA concentration (2-pass 10.7[SD 7.1] vs. 3-pass 7.9ng/ul[SD 4.4]; p=0.19) or RNA (2-pass 37.1[SD 26.5] vs. 3-pass 28.9ug/ul[SD 13.2]; p=0.29) between groups. While somatic oncogene RNA fusion (LDAH-ETV1) predictive of metastatic disease was identified in 1, DNA mutations were identified in all 33 pts (inc. 1 BRCA1 for Oxaliplatin based chemotherapy) ([Table 1]). Conclusions Specimens of adequate quantity and of high quality for CMP in pancreatic cancer can be procured in nearly 95% of patients by performing 2 dedicated passes using 22G Franseen needle, adopting fanning maneuver and stylet-retraction technique. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S298
Validation of a protocol-based approach for endoscopic management of common bile duct stones (CBDS)
Aims Despite being practiced for 45 years, approach to endoscopic management of CBDS has not been standardized. We prospectively examined outcomes of predetermined ERCP protocol. Methods Based on predetermined protocol, after biliary sphincterotomy, stone extraction was attempted by standard techniques. When standard techniques failed, presence of tapered duct (distal to widest CBD diameter) and stone-duct ratio were estimated to guide management. Large balloon sphincteroplasty (LBS) performed for tapered duct (ratio1). Main outcome was single session ductal clearance ([Fig. 1]). Results Of 260 pts, 20.8% had prior failed CBDS extraction and 7.7% required advanced cannulation. 208 of 260 (80%) pts had no tapered duct or stone-duct mismatch. In these 208 pts, single-session ductal clearance was achieved using standard techniques in 99.5%. Of 52 (20%) patients with challenging CBDS, tapered duct was in 86.5% and/or stone-duct mismatch in 38.5%. Single-session ductal clearance was achieved in all 52 pts by LBS in 90.4%, ML in 19.2%, SOCL in 17.3%. On multiple logistic regression, there was significant association between stone-duct mismatch and lithotripsy technique with SOCL indispensable for stone-duct ratio>1.1 (OR53.9,p=0.02). Overall single-session ductal clearance rate was 99.6%, adverse events in 3.8%. Conclusions Predetermined protocol enabled efficient single-session ductal clearance of CBDS with high technical success and low adverse events. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S298
Validation of a protocol-based approach for endoscopic management of common bile duct stones (CBDS)
Aims Despite being practiced for 45 years, approach to endoscopic management of CBDS has not been standardized. We prospectively examined outcomes of predetermined ERCP protocol. Methods Based on predetermined protocol, after biliary sphincterotomy, stone extraction was attempted by standard techniques. When standard techniques failed, presence of tapered duct (distal to widest CBD diameter) and stone-duct ratio were estimated to guide management. Large balloon sphincteroplasty (LBS) performed for tapered duct (ratio1). Main outcome was single session ductal clearance ([Fig. 1]). Results Of 260 pts, 20.8% had prior failed CBDS extraction and 7.7% required advanced cannulation. 208 of 260 (80%) pts had no tapered duct or stone-duct mismatch. In these 208 pts, single-session ductal clearance was achieved using standard techniques in 99.5%. Of 52 (20%) patients with challenging CBDS, tapered duct was in 86.5% and/or stone-duct mismatch in 38.5%. Single-session ductal clearance was achieved in all 52 pts by LBS in 90.4%, ML in 19.2%, SOCL in 17.3%. On multiple logistic regression, there was significant association between stone-duct mismatch and lithotripsy technique with SOCL indispensable for stone-duct ratio>1.1 (OR53.9,p=0.02). Overall single-session ductal clearance rate was 99.6%, adverse events in 3.8%. Conclusions Predetermined protocol enabled efficient single-session ductal clearance of CBDS with high technical success and low adverse events. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S49
Impact of slim linear echoendoscope (SLE) on the practice of EUS
Aims There is limited data on the impact of slim linear echoendoscopes (SLE) on the practice of EUS. Methods As a part of quality-assessment and improvement process, data on the need for use of SLE (Pentax EG34-J10U; distal rigid tip 11.5mm, insertion tube 11.5mm, instrument channel 2.8mm) were documented prospectively in 2,000 consecutive procedures over a 10-month period. When EUS examination using a standard size echoendoscope (Olympus, Pentax or Fujifilm) failed due to technical limitations, the procedure was reattempted in the same session using a SLE. Main outcome was to evaluate the impact of SLE, which was defined as the establishment of a new diagnosis or if the findings altered subsequent management. Results Examination failed in 23 of 2,000 EUS procedures (1.15%, 95% CI, 0.7-1.7%) performed using a standard size echoendoscope (14 male, median age 73 [range 56-86]). Examination was technically successful when using SLE in 22 of 23 (95.7%) procedures with median procedure duration of 12 mins (range 5-40 mins) ([Fig. 1]). Failure in 1 patient was due to inability to navigate SLE across malignant laryngeal stricture. SLE impacted clinical management in all 22 patients (100%) in whom the procedure was technically successful by establishing a tissue diagnosis in 19 (malignancy 16; benign 3) and altering the treatment plan in 3 (excluding malignancy in 2 and chronic pancreatitis in 1). There were no adverse events. Conclusions Although only a select 1.15% of patients undergoing EUS merited examination using the slim linear echoendoscope, the procedure had a significant impact on the clinical management in more than 95% of this cohort. Our findings suggest that the slim linear echoendoscope would be a useful addition to the endoscopy armamentarium at large volume EUS referral centers. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S49
Impact of slim linear echoendoscope (SLE) on the practice of EUS
Aims There is limited data on the impact of slim linear echoendoscopes (SLE) on the practice of EUS. Methods As a part of quality-assessment and improvement process, data on the need for use of SLE (Pentax EG34-J10U; distal rigid tip 11.5mm, insertion tube 11.5mm, instrument channel 2.8mm) were documented prospectively in 2,000 consecutive procedures over a 10-month period. When EUS examination using a standard size echoendoscope (Olympus, Pentax or Fujifilm) failed due to technical limitations, the procedure was reattempted in the same session using a SLE. Main outcome was to evaluate the impact of SLE, which was defined as the establishment of a new diagnosis or if the findings altered subsequent management. Results Examination failed in 23 of 2,000 EUS procedures (1.15%, 95% CI, 0.7-1.7%) performed using a standard size echoendoscope (14 male, median age 73 [range 56-86]). Examination was technically successful when using SLE in 22 of 23 (95.7%) procedures with median procedure duration of 12 mins (range 5-40 mins) ([Fig. 1]). Failure in 1 patient was due to inability to navigate SLE across malignant laryngeal stricture. SLE impacted clinical management in all 22 patients (100%) in whom the procedure was technically successful by establishing a tissue diagnosis in 19 (malignancy 16; benign 3) and altering the treatment plan in 3 (excluding malignancy in 2 and chronic pancreatitis in 1). There were no adverse events. Conclusions Although only a select 1.15% of patients undergoing EUS merited examination using the slim linear echoendoscope, the procedure had a significant impact on the clinical management in more than 95% of this cohort. Our findings suggest that the slim linear echoendoscope would be a useful addition to the endoscopy armamentarium at large volume EUS referral centers. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 5 May 2022
- Published by Elsevier in Gastrointestinal Endoscopy Clinics of North America
- Vol. 32 (3) , 385-395
Basic and Advanced Biliary Cannulation
- 5 May 2022
- Published by Elsevier in Gastrointestinal Endoscopy Clinics of North America
- Vol. 32 (3) , 385-395
Basic and Advanced Biliary Cannulation
- Open Access
- 31 July 2019
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 52 (4) , 299-300
Endoscopic Ultrasound-Guided Drainage of Peripancreatic Fluid Collections
- 31 July 2019
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 52 (4) , 299-300
Open AccessEndoscopic Ultrasound-Guided Drainage of Peripancreatic Fluid Collections
- 5 April 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (16_supplem)
Short- and Long-Term Safety of PEG-J Used for Continuous Infusion of Levodopa-Carbidopa Intestinal Gel (P6.377)
- 5 April 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (16_supplem)
Short- and Long-Term Safety of PEG-J Used for Continuous Infusion of Levodopa-Carbidopa Intestinal Gel (P6.377)
- 1 April 2016
- Published by Elsevier in Gastrointestinal Endoscopy Clinics of North America
- Vol. 26 (2) , 221-227
Lessons Learned from Traditional NOTES
- 1 April 2016
- Published by Elsevier in Gastrointestinal Endoscopy Clinics of North America
- Vol. 26 (2) , 221-227
Lessons Learned from Traditional NOTES