Serhat Özsoy
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Serhat Özsoy has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ebuderda Günay
Department of Wild Animal Disease and Ecology, Faculty of Veterinary Medicine, Istanbul University-Cerrahpasa, Istanbul 34320, Türkiye
2 shared publications - Yetkin Öztürk
Department of Molecular Biology and Genetics, Faculty of Science and Literature İstanbul Technical University İstanbul Turkey
2 shared publications - Ali Koçyiğit
Harran Universitesi
1 shared publication - Ana Pešić
Department of Equine, Small Animal, Poultry and Wild Animal Diseases, Faculty of Veterinary Medicine, University of Belgrade, 11000 Belgrade, Serbia
1 shared publication - Atakan Arabacı
Metallurgical and Materials Engineering Department, Chemical, and Metallurgical Engineering Faculty, Istanbul Technical University, Istanbul, Turkey
1 shared publication - Emine Irem Deveci
Department of Wild Animal Diseases and Ecology, Faculty of Veterinary Medicine, Istanbul University-Cerrahpasa, Istanbul, Türkiye
1 shared publication
Latest Publications
- 29 August 2026
- Published by Erciyes Universitesi (DergiPark) in Erciyes Üniversitesi Veteriner Fakültesi Dergisi
- Vol. 23 (2) , 209-219
Computed Tomographic Assessment of Splenic Size in Healthy Common Buzzards (Buteo buteo): Establishment of Preliminary Observational Ranges and a Case Presentation of Suspected Splenomegaly
The spleen is one of the principal immune-associated organs in avian species, and changes in splenic size may accompany systemic pathological conditions. However, imaging-based data on splenic size in raptors, particularly during the antemortem period, remain limited. This study aimed to describe preliminary observational ranges for splenic size in clinically healthy common buzzards (Buteo buteo) using computed tomography (CT), based on linear measurements obtained in three anatomical planes: transversal, dorsal, and sagittal. Ten clinically healthy adult common buzzards (n = 10) were included in the descriptive analysis. In addition, one common buzzard showing markedly increased splenic dimensions was evaluated separately as an illustrative case and compared descriptively with the observational ranges derived from the clinically healthy group. Based on descriptive statistics and non-parametric percentile analysis, preliminary observational ranges were identified as 7.4-14.1 mm in the transversal plane, 7.2-12.1 mm in the dorsal plane, and 7.6-13.2 mm in the sagittal plane. Splenic measurements obtained from the illustrative case exceeded these ranges substantially in all planes, indicating marked splenic enlargement under the applied imaging protocol. This study provides preliminary CT-based morphometric data on splenic size in the common buzzard. The presented values should be interpreted as descriptive orientation data rather than formal reference intervals and may support the assessment of splenic morphology in clinical and research settings when interpreted alongside other clinical and clinicopathological findings.
- 29 August 2026
- Published by Erciyes Universitesi (DergiPark) in Erciyes Üniversitesi Veteriner Fakültesi Dergisi
- Vol. 23 (2) , 209-219
Computed Tomographic Assessment of Splenic Size in Healthy Common Buzzards (Buteo buteo): Establishment of Preliminary Observational Ranges and a Case Presentation of Suspected Splenomegaly
The spleen is one of the principal immune-associated organs in avian species, and changes in splenic size may accompany systemic pathological conditions. However, imaging-based data on splenic size in raptors, particularly during the antemortem period, remain limited. This study aimed to describe preliminary observational ranges for splenic size in clinically healthy common buzzards (Buteo buteo) using computed tomography (CT), based on linear measurements obtained in three anatomical planes: transversal, dorsal, and sagittal. Ten clinically healthy adult common buzzards (n = 10) were included in the descriptive analysis. In addition, one common buzzard showing markedly increased splenic dimensions was evaluated separately as an illustrative case and compared descriptively with the observational ranges derived from the clinically healthy group. Based on descriptive statistics and non-parametric percentile analysis, preliminary observational ranges were identified as 7.4-14.1 mm in the transversal plane, 7.2-12.1 mm in the dorsal plane, and 7.6-13.2 mm in the sagittal plane. Splenic measurements obtained from the illustrative case exceeded these ranges substantially in all planes, indicating marked splenic enlargement under the applied imaging protocol. This study provides preliminary CT-based morphometric data on splenic size in the common buzzard. The presented values should be interpreted as descriptive orientation data rather than formal reference intervals and may support the assessment of splenic morphology in clinical and research settings when interpreted alongside other clinical and clinicopathological findings.
- 30 March 2026
- Published by Kütahya Dumlupinar Üniversitesi in Journal of Scientific Reports-A
- No. 064,p. 6-14
Surgical treatment of preovulatory follicular stasis in a Hermann's tortoise with central plastronotomy: A case report
An 8-year-old female Hermann's tortoise (Testudo hermanni) was presented to our clinic with a three-month history of anorexia and lethargy. A diagnostic evaluation was performed, including a complete blood count (CBC), serum biochemistry analysis, and radiographic, ultrasonographic, and computed tomography (CT) imaging. Based on these findings, preovulatory follicular stasis was diagnosed. Surgical intervention was planned using a central plastronotomy approach. The procedure was performed under general anaesthesia, and all retained follicles were successfully removed from the coelomic cavity. The plastron was repositioned and stabilized using titanium mini-plates and screws. The patient was discharged on the same day, regained voluntary appetite by the third postoperative day, and exhibited progressive recovery over a one-year follow-up period.
- 30 March 2026
- Published by Kütahya Dumlupinar Üniversitesi in Journal of Scientific Reports-A
- No. 064,p. 6-14
Surgical treatment of preovulatory follicular stasis in a Hermann's tortoise with central plastronotomy: A case report
An 8-year-old female Hermann's tortoise (Testudo hermanni) was presented to our clinic with a three-month history of anorexia and lethargy. A diagnostic evaluation was performed, including a complete blood count (CBC), serum biochemistry analysis, and radiographic, ultrasonographic, and computed tomography (CT) imaging. Based on these findings, preovulatory follicular stasis was diagnosed. Surgical intervention was planned using a central plastronotomy approach. The procedure was performed under general anaesthesia, and all retained follicles were successfully removed from the coelomic cavity. The plastron was repositioned and stabilized using titanium mini-plates and screws. The patient was discharged on the same day, regained voluntary appetite by the third postoperative day, and exhibited progressive recovery over a one-year follow-up period.
- Open Access
- 15 March 2024
- Published by AVES YAYINCILIK A.Ş.
- p. 29-45
Kliniğe Giriş ve Klinik Uygulamalar
- 15 March 2024
- Published by AVES YAYINCILIK A.Ş.
- p. 29-45
Open AccessKliniğe Giriş ve Klinik Uygulamalar
- Open Access
- 24 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
A new patient-specific overformed anatomical implant design method to reconstruct dysplastic femur trochlea
Patellar luxation with condylar defect is a challenging situation for reconstruction in humans. Patella reluxation, cartilage damage and pain are the most common complications. This study aims to present a new patient specific method of overformed implant design and clinical implantation that prevents luxation of patella without damaging the cartilage in a dog. Design processes are Computer Tomography, Computer Assisted Design, rapid prototyping of the bone replica, creation of the implant with surgeon’s haptic knowledge on the bone replica, 3D printing of the implant and clinical application. The implant was fully seated on the bone. Patella reluxation or implant-related bone problem was not observed 80 days after the operation. However, before the implant application, there were soft tissue problems due to previous surgeries. Three-point bending test and finite element analysis were performed to determine the biomechanical safety of the implant. The stress acting on the implant was below the biomechanical limits of the implant. More cases with long-term follow-up are needed to confirm the success of this method in patellar luxation. Compared with trochlear sulcoplasty and total knee replacement, there was no cartilage damage done by surgeons with this method, and the implant keeps the patella functionally in sulcus. This is a promising multidisciplinary method that can be applied to any part of the bone and can solve some orthopaedic problems with surgeon’s haptic knowledge.
- 24 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Open AccessA new patient-specific overformed anatomical implant design method to reconstruct dysplastic femur trochlea
Patellar luxation with condylar defect is a challenging situation for reconstruction in humans. Patella reluxation, cartilage damage and pain are the most common complications. This study aims to present a new patient specific method of overformed implant design and clinical implantation that prevents luxation of patella without damaging the cartilage in a dog. Design processes are Computer Tomography, Computer Assisted Design, rapid prototyping of the bone replica, creation of the implant with surgeon’s haptic knowledge on the bone replica, 3D printing of the implant and clinical application. The implant was fully seated on the bone. Patella reluxation or implant-related bone problem was not observed 80 days after the operation. However, before the implant application, there were soft tissue problems due to previous surgeries. Three-point bending test and finite element analysis were performed to determine the biomechanical safety of the implant. The stress acting on the implant was below the biomechanical limits of the implant. More cases with long-term follow-up are needed to confirm the success of this method in patellar luxation. Compared with trochlear sulcoplasty and total knee replacement, there was no cartilage damage done by surgeons with this method, and the implant keeps the patella functionally in sulcus. This is a promising multidisciplinary method that can be applied to any part of the bone and can solve some orthopaedic problems with surgeon’s haptic knowledge.
- Open Access
- 23 December 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Brazilian Journal of Veterinary Research and Animal Science
- Vol. 58, e182908
Treatment of fractures and other orthopedic problems in cats and dogs using versatile external fixator
Many complicated bone fractures can be healed by different techniques including linear external fixation. New generation linear external fixators enhanced the scope of application for bone fractures by mechanical progress. Difficulties include implementing enough pins through fixation clamps to the comminuted fragments or clamp addition and fixing it properly to the rod with the correct pin insertion angle. Effective configurations may not always result. This study sought to reveal the clinical efficiency of modified clamps of a versatile external fixator (VEF) to fix different types of fractures and orthopedic problems according to the radiographic and clinical results. We used this fixator on 17 cats and 17 dogs of different ages and sizes, having different types of antebrachium, humerus, tibia, ulna fractures, and bone-muscle deformities. Clamps had different features to connect fixator pins. Many fixator configurations were created according to the fracture type and body weight of the animals. The most used ones were unilateral and bilateral configurations. The callus formation and visual gait analysis were observed after the operations, until the removal of the fixator. After fixator removal, the visual gait status of the limbs was excellent in 67% of the cases, good in 15%, fair in 12%, and poor in 6%. We found that rods and fixator pins were connected easily by semi-locked clamps. Also, the double pin holding clamps saved space on the fixation rod by the application of two pins through one clamp. We think that clamps of versatile external fixators can easily be constructed to limb fractures and save time during surgery.
- 23 December 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Brazilian Journal of Veterinary Research and Animal Science
- Vol. 58, e182908
Open AccessTreatment of fractures and other orthopedic problems in cats and dogs using versatile external fixator
Many complicated bone fractures can be healed by different techniques including linear external fixation. New generation linear external fixators enhanced the scope of application for bone fractures by mechanical progress. Difficulties include implementing enough pins through fixation clamps to the comminuted fragments or clamp addition and fixing it properly to the rod with the correct pin insertion angle. Effective configurations may not always result. This study sought to reveal the clinical efficiency of modified clamps of a versatile external fixator (VEF) to fix different types of fractures and orthopedic problems according to the radiographic and clinical results. We used this fixator on 17 cats and 17 dogs of different ages and sizes, having different types of antebrachium, humerus, tibia, ulna fractures, and bone-muscle deformities. Clamps had different features to connect fixator pins. Many fixator configurations were created according to the fracture type and body weight of the animals. The most used ones were unilateral and bilateral configurations. The callus formation and visual gait analysis were observed after the operations, until the removal of the fixator. After fixator removal, the visual gait status of the limbs was excellent in 67% of the cases, good in 15%, fair in 12%, and poor in 6%. We found that rods and fixator pins were connected easily by semi-locked clamps. Also, the double pin holding clamps saved space on the fixation rod by the application of two pins through one clamp. We think that clamps of versatile external fixators can easily be constructed to limb fractures and save time during surgery.