Jason E. Brant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jason E. Brant has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Adam J. Mirarchi
Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, OR
1 shared publication Alden Wyland
Department of Orthopaedics & Rehabilitation, Oregon Health & Science University, Sam Jackson Hall, Suite 2360, 3181 S.W. Sam Jackson Park Rd, Portland, OR 97239, USA
1 shared publication- Austin R. Thompson
Department of Epidemiology and Biostatistics, University of California, San Francisco , San Francisco, CA 94158
1 shared publication Elizabeth G. Lieberman
Department of Orthopaedics & Rehabilitation, Oregon Health & Science University, Sam Jackson Hall, Suite 2360, 3181 S.W. Sam Jackson Park Rd, Portland, OR 97239, USA
1 shared publication- Erik R. Ensrud
Department of Orthopaedics and Rehabilitation Oregon Health & Science University Portland Oregon
1 shared publication - Jorge R. Walker
Department of Radiology, Oregon Health and Science University, Portland, Oregon
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Effect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation
Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle. Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes. Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001). Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Open AccessEffect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation
Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle. Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes. Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001). Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (5) , 810-818
Effects of delayed postoperative void and preoperative urologic symptoms on delay in time of discharge for elective lumbar decompression surgery
- 1 May 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (5) , 810-818
Effects of delayed postoperative void and preoperative urologic symptoms on delay in time of discharge for elective lumbar decompression surgery
- 1 April 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (2)
Tendon Transfers for the Treatment of Finger Flexion Weakness in a Patient With Inclusion Body Myositis
Case: We describe a 71-year-old patient with inclusion body myositis (IBM), characterized by progressive atrophy and weakness in his left upper extremity. This patient underwent extensor carpi radialis longus to flexor pollicis longus and brachioradialis to flexor digitorum profundus tendon transfers in the left upper extremity to reduce IBM-related functional deficits. He had noticeable improvements in finger flexion after the transfers, which have been sustained for 2 years after the procedure. Conclusion: This case reinforces that this novel tendon transfer may be an effective treatment option to improve hand function and activities of daily living in patients with IBM.
- 1 April 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (2)
Tendon Transfers for the Treatment of Finger Flexion Weakness in a Patient With Inclusion Body Myositis
Case: We describe a 71-year-old patient with inclusion body myositis (IBM), characterized by progressive atrophy and weakness in his left upper extremity. This patient underwent extensor carpi radialis longus to flexor pollicis longus and brachioradialis to flexor digitorum profundus tendon transfers in the left upper extremity to reduce IBM-related functional deficits. He had noticeable improvements in finger flexion after the transfers, which have been sustained for 2 years after the procedure. Conclusion: This case reinforces that this novel tendon transfer may be an effective treatment option to improve hand function and activities of daily living in patients with IBM.