EOEdna Maria Morais Oliveira

Edna Maria Morais Oliveira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edna Maria Morais Oliveira has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    QCM Genosensor for Detection of Golden Mosaic-Resistant Transgenic Common Beans in Non-Amplified Samples

    by Isabella C. S. Nascimento, Andressa M. Souza, Andrea P. Parente, Edna M. M. Oliveira, Andrea Valdman, Rossana O. M. Folly, Andrea M. Salgado

    A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (L.) cultivar (BRS FC401 RMD) with resistance to Bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor’s analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor’s potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.

  • Open Access

    QCM Genosensor for Detection of Golden Mosaic-Resistant Transgenic Common Beans in Non-Amplified Samples

    by Isabella C. S. Nascimento, Andressa M. Souza, Andrea P. Parente, Edna M. M. Oliveira, Andrea Valdman, Rossana O. M. Folly, Andrea M. Salgado

    A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (Phaseolus vulgaris L.) cultivar (BRS FC401 RMD) with resistance to bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor's analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor's potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.

  • Open Access

    Near-Infrared Spectroscopy Applied to the Detection of Multiple Adulterants in Roasted and Ground Arabica Coffee

    by Cinthia de Carvalho Couto, Otniel Freitas-Silva, Edna Maria Morais Oliveira, Clara Sousa, Susana Casal

    Roasted coffee has been the target of increasingly complex adulterations. Sensitive, non-destructive, rapid and multicomponent techniques for their detection are sought after. This work proposes the detection of several common adulterants (corn, barley, soybean, rice, coffee husks and robusta coffee) in roasted ground arabica coffee (from different geographic regions), combining near-infrared (NIR) spectroscopy and chemometrics (Principal Component Analysis—PCA). Adulterated samples were composed of one to six adulterants, ranging from 0.25 to 80% (w/w). The results showed that NIR spectroscopy was able to discriminate pure arabica coffee samples from adulterated ones (for all the concentrations tested), including robusta coffees or coffee husks, and independently of being single or multiple adulterations. The identification of the adulterant in the sample was only feasible for single or double adulterations and in concentrations ≥10%. NIR spectroscopy also showed potential for the geographical discrimination of arabica coffees (South and Central America).


  • Using Real-Time PCR as a tool for monitoring the authenticity of commercial coffees

    by Thiago Ferreira, Adriana Farah, Tatiane C. Oliveira, Ivanilda S. Lima, Felipe Vitório, Edna M.M. Oliveira