YGYann Le Guillou

Yann Le Guillou

*This is an algorithmically generated author record based on publicly available information.

Yann Le Guillou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Preventing hospital readmissions of COPD patients : alerting rules on vital signs for remote patient monitoring

    by Yann Le Guillou, Florian Tilquin, Sylvain Le Liepvre, Graziella Brinchault, Tiphaine Guy, Fanny Thépault

    Introduction: After hospital discharge following an acute exacerbation of COPD (AECOPD), remote patient monitoring (RPM) can prevent readmissions [1] by alerting healthcare professionals when vital signs exceed some limits. Objectives: Compare the performance of different vital signs alert configurations in early detection of readmission. Methods: Breath rate (BR), heart rate (HR) and SpO2 of COPD patients were monitored by Bora Care RPM solution during hospitalization for AECOPD and 30 days after discharge. Results: 21 COPD patients (GOLD grade: 9.5% I, 19% II, 33% III, 24% IV; mean age 67 years) were monitored for an average session duration of 37 days (SD 11 days), 5 patients (23.8%) were readmitted. The area under the curve (AUC) of the Receiver Operating Characteristic curve (ROC) was computed to rank the performance of several alert rules on 1) fixed thresholds and 2) variable thresholds based on deviation of the last 48-hour median value from a 15-day baseline. The variable threshold applied simultaneously to SpO2, HR and BR is the best performing alert (AUC=0.84), followed by the fixed threshold applied to SpO2, HR and BR (0.82) and the variable threshold applied to HR only (0.76). Conclusion: Early detection of a patient9s risk of readmission is optimized when SpO2, HR and BR all exceed variable thresholds derived from the patient9s 15-day baseline. [1] Brinchault, G., et al. Rev Mal Resp 15.1 (2023): 70

  • Open Access

    Validity of Ultra-Short-Term HRV Analysis Using PPG—A Preliminary Study

    by Aline Taoum, Alexis Bisiaux, Florian Tilquin, Yann Le Guillou, Guy Carrault

    Continuous measurement of heart rate variability (HRV) in the short and ultra-short-term using wearable devices allows monitoring of physiological status and prevention of diseases. This study aims to evaluate the agreement of HRV features between a commercial device (Bora Band, Biosency) measuring photoplethysmography (PPG) and reference electrocardiography (ECG) and to assess the validity of ultra-short-term HRV as a surrogate for short-term HRV features. PPG and ECG recordings were acquired from 5 healthy subjects over 18 nights in total. HRV features include time-domain, frequency-domain, nonlinear, and visibility graph features and are extracted from 5 min 30 s and 1 min 30 s duration PPG recordings. The extracted features are compared with reference features of 5 min 30 s duration ECG recordings using repeated-measures correlation, Bland–Altman plots with 95% limits of agreements, Cliff’s delta, and an equivalence test. Results showed agreement between PPG recordings and ECG reference recordings for 37 out of 48 HRV features in short-term durations. Sixteen of the forty-eight HRV features were valid and retained very strong correlations, negligible to small bias, with statistical equivalence in the ultra-short recordings (1 min 30 s). The current study concludes that the Bora Band provides valid and reliable measurement of HRV features in short and ultra-short duration recordings.