Richard Kobza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard Kobza has a total of 406 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Osswald
Cardiology Division, Department of Medicine, University Hospital Basel, Basel, Switzerland
8 shared publications - Tobias Reichlin
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern , Bern
8 shared publications - Benjamin Berte
Heart Center, Luzerner Kantonsspital, Lucerne, Switzerland
7 shared publications Florim Cuculi
Department of Cardiology, Kantonsspital Lucerne , Lucerne , Switzerland
7 shared publications- Michael Kühne
Department of Cardiology, University Hospital Basel , Petersgraben 4, Basel 4031
7 shared publications - Christian Grebmer
Kantonsspital Lucerne , Lucerne , Switzerland
6 shared publications
Latest Publications
- Open Access
- 7 January 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (1) , e034365
Coffee Consumption Correlates With Better Cognitive Performance in Patients With a High Incidence for Stroke
Background: Atrial fibrillation is an independent risk factor for the development of cognitive impairments. Regular coffee consumption has shown cognitive benefits in healthy individuals. Whether regular consumption reduces cognitive decline in vulnerable patients is controversial. We investigated the association in elderly people with atrial fibrillation. Methods and Results: Daily coffee consumption was assessed using a structured nutrition questionnaire, and cognitive function was evaluated by a detailed neurocognitive‐test‐battery, including the Montreal Cognitive Assessment, Trail‐Making Test, semantic fluency, and Digit‐Symbol‐Substitution Test. The cognitive construct score combines all neurocognitive tests mentioned and provides an overall cognitive performance indicator. Hs‐CRP (high‐sensitivity C‐reactive protein) and IL‐6 (interleukin‐6) were measured to explore an association with inflammation. Results were estimated using linear mixed‐effects‐models with detailed adjustments for confounders. The 5 cups/day) was at −0.10 (95% CI, –0.10 to 0.04; p =0.048). Montreal Cognitive Assessment score in the reference group was 24.58 (95% CI, 24.58–25.32); the group with the highest intake achieved 25.25 (95% CI, 24.98–26.85; p =0.163). Inflammatory markers decreased with higher coffee consumption (hs‐CRP with 5 compared with p = 0.188, IL‐6 significantly by factor 0.73 [95% CI, 0.57–0.95], p =0.017). Conclusions: Coffee consumption in patients with atrial fibrillation may be associated with improved cognitive performance and reduced inflammatory markers. Further research is needed to confirm these findings and to consider implementation in dietary counseling for atrial fibrillation management. Registration: URL: https://www.clinicaltrials.gov ; Identifier: NCT02105844.
- 7 January 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (1) , e034365
Open AccessCoffee Consumption Correlates With Better Cognitive Performance in Patients With a High Incidence for Stroke
Background: Atrial fibrillation is an independent risk factor for the development of cognitive impairments. Regular coffee consumption has shown cognitive benefits in healthy individuals. Whether regular consumption reduces cognitive decline in vulnerable patients is controversial. We investigated the association in elderly people with atrial fibrillation. Methods and Results: Daily coffee consumption was assessed using a structured nutrition questionnaire, and cognitive function was evaluated by a detailed neurocognitive‐test‐battery, including the Montreal Cognitive Assessment, Trail‐Making Test, semantic fluency, and Digit‐Symbol‐Substitution Test. The cognitive construct score combines all neurocognitive tests mentioned and provides an overall cognitive performance indicator. Hs‐CRP (high‐sensitivity C‐reactive protein) and IL‐6 (interleukin‐6) were measured to explore an association with inflammation. Results were estimated using linear mixed‐effects‐models with detailed adjustments for confounders. The 5 cups/day) was at −0.10 (95% CI, –0.10 to 0.04; p =0.048). Montreal Cognitive Assessment score in the reference group was 24.58 (95% CI, 24.58–25.32); the group with the highest intake achieved 25.25 (95% CI, 24.98–26.85; p =0.163). Inflammatory markers decreased with higher coffee consumption (hs‐CRP with 5 compared with p = 0.188, IL‐6 significantly by factor 0.73 [95% CI, 0.57–0.95], p =0.017). Conclusions: Coffee consumption in patients with atrial fibrillation may be associated with improved cognitive performance and reduced inflammatory markers. Further research is needed to confirm these findings and to consider implementation in dietary counseling for atrial fibrillation management. Registration: URL: https://www.clinicaltrials.gov ; Identifier: NCT02105844.
- 8 May 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (25) , 2254-2258
Cardiac biomarkers for diagnosing Takotsubo syndrome
Takotsubo syndrome (TTS) is characterized by transient left ventricular wall motion anomalies associated with coronary microvascular dysfunction in the absence of culprit lesions of epicardial coronary arteries.1 The clinical presentation of TTS resembles that of typical acute coronary syndrome (ACS).2 Despite coronary angiography being the gold standard for TTS diagnosis, its limitations and unessential role in disease management necessitate non-invasive diagnostic methods.2 Patients with TTS exhibit distinctive patterns of classic cardiac biomarkers compared to patients with ACS. Specifically, TTS is associated with higher brain natriuretic peptide (BNP) levels attributed to heightened filling pressures, and conversely, lower levels of troponin or creatine kinase (CK), as a consequence of distinct pathophysiological mechanisms.2,3 These variations in biomarker levels have been proposed as valuable indicators in differentiating these two entities from another.4 However, although previously proposed ratios of classic cardiac biomarkers exhibit promise in distinguishing TTS from ACS, their applicability was restricted by small sample sizes and a lack of validation.5–9 Thus, the present study aims to validate these ratios in the largest database dedicated to TTS worldwide, the International Takotsubo (InterTAK) Registry.1
- 8 May 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (25) , 2254-2258
Cardiac biomarkers for diagnosing Takotsubo syndrome
Takotsubo syndrome (TTS) is characterized by transient left ventricular wall motion anomalies associated with coronary microvascular dysfunction in the absence of culprit lesions of epicardial coronary arteries.1 The clinical presentation of TTS resembles that of typical acute coronary syndrome (ACS).2 Despite coronary angiography being the gold standard for TTS diagnosis, its limitations and unessential role in disease management necessitate non-invasive diagnostic methods.2 Patients with TTS exhibit distinctive patterns of classic cardiac biomarkers compared to patients with ACS. Specifically, TTS is associated with higher brain natriuretic peptide (BNP) levels attributed to heightened filling pressures, and conversely, lower levels of troponin or creatine kinase (CK), as a consequence of distinct pathophysiological mechanisms.2,3 These variations in biomarker levels have been proposed as valuable indicators in differentiating these two entities from another.4 However, although previously proposed ratios of classic cardiac biomarkers exhibit promise in distinguishing TTS from ACS, their applicability was restricted by small sample sizes and a lack of validation.5–9 Thus, the present study aims to validate these ratios in the largest database dedicated to TTS worldwide, the International Takotsubo (InterTAK) Registry.1
- Open Access
- 28 December 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Combined complex electrophysiological interventions due to improved standardization and efficiency: proof of concept
The field of cardiac electrophysiology (EP) is evolving rapidly. Over the years, with the evolution of ablation technologies, including the development of irrigated ablation catheters with contact force sensing, steerable sheaths, 3D mapping systems, multipolar mapping catheters, and pre- and peri-procedural imaging, the treatment of complex arrhythmias with catheter ablation has expanded significantly. Implementation of lean management strategies for complex EP procedures, with standardized, simplified, shorter, and more predictable workflows, has the potential to significantly enhance procedural efficiency.1–6
- 28 December 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Open AccessCombined complex electrophysiological interventions due to improved standardization and efficiency: proof of concept
The field of cardiac electrophysiology (EP) is evolving rapidly. Over the years, with the evolution of ablation technologies, including the development of irrigated ablation catheters with contact force sensing, steerable sheaths, 3D mapping systems, multipolar mapping catheters, and pre- and peri-procedural imaging, the treatment of complex arrhythmias with catheter ablation has expanded significantly. Implementation of lean management strategies for complex EP procedures, with standardized, simplified, shorter, and more predictable workflows, has the potential to significantly enhance procedural efficiency.1–6
- Open Access
- 28 December 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia
High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and the risk of steam pop. Consecutive patients undergoing ventricular ablation using QDOT were included in a prospective single-centre registry. Procedural data, complications, and follow-up were systematically analysed and compared with a historical ventricular tachycardia (VT) and premature ventricular complexes (PVC) cohort ablated using STSF. QMODE (≤50 W) ablation was performed in 107 patients [age 62 ± 13 years; 76% male; VT (n = 41); PVC (n = 66)]. A total of 2456 applications were analysed [power: 45.9 ± 5.0 W with minimal power titration (90% > 95% max power); duration 26 ± 8 s; impedance drop 9.4 ± 4.7 Ω; ablation index: 569 ± 163; mean–max temperature 44.3 ± 2.6°C]. Ventricular tachycardia ablation was associated with shorter radiofrequency (RF) time and a trend towards shorter procedure times using QDOT (QDOT vs. STSF: 20.1 ± 14.7 vs. 31 ± 17 min; P = 0.002, 151 ± 59 vs. 172 ± 48 min; P = 0.06). Complications, VT recurrence, and mortality rates were comparable (QDOT vs. STSF: 2% vs. 2%; P = 0.9, 24% vs. 27%; P = 0.82, and 2% vs. 4%; P = 0.67). Five audible steam pops (0.02%) occurred. Premature ventricular complex ablation was associated with comparable RF and procedure times (QDOT vs. STSF: 4.8 ± 4.6 vs. 3.9 ± 3.1 min; P = 0.25 and 96.1 ± 31.9 vs. 94.6 ± 24.7 min; P = 0.75). Complication and PVC recurrence were also comparable (QDOT vs. STSF: 0% vs. 3%; P = 0.17 and 19% vs. 22%; P = 0.71). Ventricular ablation using QMODE ≤ 50 W is safe and effective for both VT and PVC ablation and is associated with a low risk for steam pop.
- 28 December 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Open AccessPerformance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia
High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and the risk of steam pop. Consecutive patients undergoing ventricular ablation using QDOT were included in a prospective single-centre registry. Procedural data, complications, and follow-up were systematically analysed and compared with a historical ventricular tachycardia (VT) and premature ventricular complexes (PVC) cohort ablated using STSF. QMODE (≤50 W) ablation was performed in 107 patients [age 62 ± 13 years; 76% male; VT (n = 41); PVC (n = 66)]. A total of 2456 applications were analysed [power: 45.9 ± 5.0 W with minimal power titration (90% > 95% max power); duration 26 ± 8 s; impedance drop 9.4 ± 4.7 Ω; ablation index: 569 ± 163; mean–max temperature 44.3 ± 2.6°C]. Ventricular tachycardia ablation was associated with shorter radiofrequency (RF) time and a trend towards shorter procedure times using QDOT (QDOT vs. STSF: 20.1 ± 14.7 vs. 31 ± 17 min; P = 0.002, 151 ± 59 vs. 172 ± 48 min; P = 0.06). Complications, VT recurrence, and mortality rates were comparable (QDOT vs. STSF: 2% vs. 2%; P = 0.9, 24% vs. 27%; P = 0.82, and 2% vs. 4%; P = 0.67). Five audible steam pops (0.02%) occurred. Premature ventricular complex ablation was associated with comparable RF and procedure times (QDOT vs. STSF: 4.8 ± 4.6 vs. 3.9 ± 3.1 min; P = 0.25 and 96.1 ± 31.9 vs. 94.6 ± 24.7 min; P = 0.75). Complication and PVC recurrence were also comparable (QDOT vs. STSF: 0% vs. 3%; P = 0.17 and 19% vs. 22%; P = 0.71). Ventricular ablation using QMODE ≤ 50 W is safe and effective for both VT and PVC ablation and is associated with a low risk for steam pop.
- Open Access
- 8 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5175
Transvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry
Background: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. Methods: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. Results: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14–1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). Conclusions: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.
- 8 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5175
Open AccessTransvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry
Background: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. Methods: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. Results: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14–1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). Conclusions: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.
- Open Access
- 21 March 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (6) , e028255
Bone Morphogenetic Protein 10—A Novel Biomarker to Predict Adverse Outcomes in Patients With Atrial Fibrillation
Background: Patients with atrial fibrillation (AF) face an increased risk of death and major adverse cardiovascular events (MACE). We aimed to assess the predictive value of the novel atrial‐specific biomarker BMP10 (bone morphogenetic protein 10) for death and MACE in patients with AF in comparison with NT‐proBNP (N‐terminal prohormone of B‐type natriuretic peptide). Methods and Results: BMP10 and NT‐proBNP were measured in patients with AF enrolled in Swiss‐AF (Swiss Atrial Fibrillation Study), a prospective multicenter cohort study. A total of 2219 patients were included (median follow‐up 4.3 years [interquartile range 3.9, 5.1], mean age 73±9 years, 73% male). In multivariable Cox proportional hazard models, the adjusted hazard ratio (aHR) associated with 1 ng/mL increase of BMP10 was 1.60 (95% CI, 1.37–1.87) for all‐cause death, and 1.54 (95% CI, 1.35–1.76) for MACE. For all‐cause death, the concordance index was 0.783 (95% CI, 0.763–0.809) for BMP10, 0.784 (95% CI, 0.765–0.810) for NT‐proBNP, and 0.789 (95% CI, 0.771–0.815) for both biomarkers combined. For MACE, the concordance index was 0.732 (95% CI, 0.715–0.754) for BMP10, 0.747 (95% CI, 0.731–0.768) for NT‐proBNP, and 0.750 (95% CI, 0.734–0.771) for both biomarkers combined. When grouping patients according to NT‐proBNP categories (900 ng/L), higher aHRs were observed in patients with high BMP10 in the categories of low NT‐proBNP (all‐cause death aHR, 2.28 [95% CI, 1.15–4.52], MACE aHR, 1.88 [95% CI, 1.07–3.28]) and high NT‐proBNP (all‐cause death aHR, 1.61 [95% CI, 1.14–2.26], MACE aHR, 1.38 [95% CI, 1.07–1.80]). Conclusions: BMP10 strongly predicted all‐cause death and MACE in patients with AF. BMP10 provided additional prognostic information in low‐ and high‐risk patients according to NT‐proBNP stratification. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02105844.
- 21 March 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (6) , e028255
Open AccessBone Morphogenetic Protein 10—A Novel Biomarker to Predict Adverse Outcomes in Patients With Atrial Fibrillation
Background: Patients with atrial fibrillation (AF) face an increased risk of death and major adverse cardiovascular events (MACE). We aimed to assess the predictive value of the novel atrial‐specific biomarker BMP10 (bone morphogenetic protein 10) for death and MACE in patients with AF in comparison with NT‐proBNP (N‐terminal prohormone of B‐type natriuretic peptide). Methods and Results: BMP10 and NT‐proBNP were measured in patients with AF enrolled in Swiss‐AF (Swiss Atrial Fibrillation Study), a prospective multicenter cohort study. A total of 2219 patients were included (median follow‐up 4.3 years [interquartile range 3.9, 5.1], mean age 73±9 years, 73% male). In multivariable Cox proportional hazard models, the adjusted hazard ratio (aHR) associated with 1 ng/mL increase of BMP10 was 1.60 (95% CI, 1.37–1.87) for all‐cause death, and 1.54 (95% CI, 1.35–1.76) for MACE. For all‐cause death, the concordance index was 0.783 (95% CI, 0.763–0.809) for BMP10, 0.784 (95% CI, 0.765–0.810) for NT‐proBNP, and 0.789 (95% CI, 0.771–0.815) for both biomarkers combined. For MACE, the concordance index was 0.732 (95% CI, 0.715–0.754) for BMP10, 0.747 (95% CI, 0.731–0.768) for NT‐proBNP, and 0.750 (95% CI, 0.734–0.771) for both biomarkers combined. When grouping patients according to NT‐proBNP categories (900 ng/L), higher aHRs were observed in patients with high BMP10 in the categories of low NT‐proBNP (all‐cause death aHR, 2.28 [95% CI, 1.15–4.52], MACE aHR, 1.88 [95% CI, 1.07–3.28]) and high NT‐proBNP (all‐cause death aHR, 1.61 [95% CI, 1.14–2.26], MACE aHR, 1.38 [95% CI, 1.07–1.80]). Conclusions: BMP10 strongly predicted all‐cause death and MACE in patients with AF. BMP10 provided additional prognostic information in low‐ and high‐risk patients according to NT‐proBNP stratification. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02105844.
- Open Access
- 9 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (4) , 1500-1502
Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath
Aims: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP.Methods and Results: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8–16 min).Conclusion: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.
- 9 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (4) , 1500-1502
Open AccessEliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath
Aims: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP.Methods and Results: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8–16 min).Conclusion: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.
- 26 February 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 194, 113-121
Direct Oral Anticoagulants Versus Vitamin K Antagonists for the Treatment of Left Ventricular Thrombi—Insights from a Swiss Multicenter Registry
- 26 February 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 194, 113-121
Direct Oral Anticoagulants Versus Vitamin K Antagonists for the Treatment of Left Ventricular Thrombi—Insights from a Swiss Multicenter Registry
- Open Access
- 1 January 2023
- Published by Hogrefe Publishing Group in Praxis
- Vol. 112 (1) , 36-41
Eine transiente hypertrophe Kardiomyopathie?
Zusammenfassung. Wir berichten über eine 79-jährige Patientin nach stumpfem Thoraxtrauma. Aufgrund der T-Negativierungen im 12-Ableitungs-EKG und einer apikalen linksventrikulären Hypertrophie in der Echokardiografie und in der Herz-MRT-Untersuchung wurde eine apikale hypertrophe Kardiopathie postuliert. In der Folge zeigte sich, dass diese Befunde nur transient vorhanden waren und sich im Verlauf komplett normalisierten. Die apikalen Veränderungen kamen nicht durch eine Hypertrophie der Kardiomyozyten, sondern durch ein myokardiales Ödem zustande. Als Ursache kam sowohl ein Takotsubo-Syndrom als auch eine Contusio cordis in Betracht.
- 1 January 2023
- Published by Hogrefe Publishing Group in Praxis
- Vol. 112 (1) , 36-41
Open AccessEine transiente hypertrophe Kardiomyopathie?
Zusammenfassung. Wir berichten über eine 79-jährige Patientin nach stumpfem Thoraxtrauma. Aufgrund der T-Negativierungen im 12-Ableitungs-EKG und einer apikalen linksventrikulären Hypertrophie in der Echokardiografie und in der Herz-MRT-Untersuchung wurde eine apikale hypertrophe Kardiopathie postuliert. In der Folge zeigte sich, dass diese Befunde nur transient vorhanden waren und sich im Verlauf komplett normalisierten. Die apikalen Veränderungen kamen nicht durch eine Hypertrophie der Kardiomyozyten, sondern durch ein myokardiales Ödem zustande. Als Ursache kam sowohl ein Takotsubo-Syndrom als auch eine Contusio cordis in Betracht.
- Open Access
- 29 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 7070
Early Experience with the Biotronik Protego ICD Lead
Background: In the last decade, newer generation ICD leads have been developed based on mechanistic insides of priorly failing leads. The aim of our study was to assess the long-term performance and mechanisms of failure of the 2013-introduced Biotronik Protego ICD lead in a real-world population. Methods: All patients, who underwent implantation of a Protego ICD lead at the Heart Centre Lucerne (Lucerne, Switzerland) between November 2013 and March 2017, were followed up with semi-annual device-controls. The primary endpoint was defined as lead failure, secondary endpoints compromised all-cause death, (in)appropriate shocks and the need for reintervention. Results: A total of 64 patients (mean age 66.7 ± 8.7 years, 30% female) underwent implantation of a Protego ICD lead: 78% for primary prevention, 53% had underlying ischemic heart disease, and 40.6% had a dilated cardiomyopathy (DCM). Mean left ventricular ejection fraction (LVEF) was 32.6 ± 10.5%. A total of 24 patients were treated with cardiac resynchronization therapy (CRT), and their baseline LVEF improved from 27.8 ± 7.3% before to 39.8 ± 12.5 after implantation (p < 0.001). Mean time to follow-up was 5.5 ± 0.9 years. Overall, 14 patients (26.6%) suffered from at least one episode of sustained ventricular tachycardia; in total 10 patients (15.6%) died. Two patients experienced lead failure due to lead fracture after 5.5 and 5.7 years, which was clinically apparent by an abrupt rise in lead impedance (>2000 Ω) and by repetitive inappropriate shocks, respectively. Conclusions: In this retrospective observational study, the calculated annual lead failure rate of the Biotronik Protego ICD lead was 0.59% per patient—thus, the durability and long-term performance seem to be promising.
- 29 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 7070
Open AccessEarly Experience with the Biotronik Protego ICD Lead
Background: In the last decade, newer generation ICD leads have been developed based on mechanistic insides of priorly failing leads. The aim of our study was to assess the long-term performance and mechanisms of failure of the 2013-introduced Biotronik Protego ICD lead in a real-world population. Methods: All patients, who underwent implantation of a Protego ICD lead at the Heart Centre Lucerne (Lucerne, Switzerland) between November 2013 and March 2017, were followed up with semi-annual device-controls. The primary endpoint was defined as lead failure, secondary endpoints compromised all-cause death, (in)appropriate shocks and the need for reintervention. Results: A total of 64 patients (mean age 66.7 ± 8.7 years, 30% female) underwent implantation of a Protego ICD lead: 78% for primary prevention, 53% had underlying ischemic heart disease, and 40.6% had a dilated cardiomyopathy (DCM). Mean left ventricular ejection fraction (LVEF) was 32.6 ± 10.5%. A total of 24 patients were treated with cardiac resynchronization therapy (CRT), and their baseline LVEF improved from 27.8 ± 7.3% before to 39.8 ± 12.5 after implantation (p < 0.001). Mean time to follow-up was 5.5 ± 0.9 years. Overall, 14 patients (26.6%) suffered from at least one episode of sustained ventricular tachycardia; in total 10 patients (15.6%) died. Two patients experienced lead failure due to lead fracture after 5.5 and 5.7 years, which was clinically apparent by an abrupt rise in lead impedance (>2000 Ω) and by repetitive inappropriate shocks, respectively. Conclusions: In this retrospective observational study, the calculated annual lead failure rate of the Biotronik Protego ICD lead was 0.59% per patient—thus, the durability and long-term performance seem to be promising.