JGJoaquin Eduardo Urrutia Gomez

Joaquin Eduardo Urrutia Gomez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joaquin Eduardo Urrutia Gomez has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Markus Reischl

    Institute for Automation and Applied Informatics (IAI), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany

    4 shared publications
  • Pavel A. Levkin

    Institute of Biological and Chemical Systems – Functional Molecular Systems Karlsruhe Institute of Technology (KIT) Kaiserstraße 12 76131 Karlsruhe Germany

    4 shared publications
  • Pavel Andreevich Levkin

    Institute of Biological and Chemical Systems‐Functional Molecular Systems (IBCS‐FMS) Karlsruhe Institute of Technology (KIT) Eggenstein‐Leopoldshafen Germany

    4 shared publications
  • Anna A. Popova

    Institute of Biological and Chemical Systems (IBCS‐FMS) Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany

    3 shared publications
  • Anna Alexandrovna Popova

    Institute of Biological and Chemical Systems – Functional Molecular Systems (IBCS‐FMS) Karlsruhe Institute of Technology (KIT) Hermann‐von‐Helmholtz‐Platz 1 76344 Eggenstein‐Leopoldshafen Germany

    3 shared publications
  • David Exler

    Institute for Automation and Applied Informatics (IAI) Karlsruher Institute of Technology (KIT) Eggenstein‐Leopoldshafen Baden‐Württemberg Germany

    3 shared publications

Latest Publications

  • Open Access

    Bayesian optimization for design parameters of 3D image data analysis

    by David Exler, Joaquin Eduardo Urrutia Gómez, Martin Krüger, Maike Schliephake, John Jbeily, Mario Vitacolonna, Rüdiger Rudolf, Markus Reischl

  • Open Access

    LLM‐Based Scientific Assistants for Knowledge Extraction: Which Design Choices Matter?

    by David Exler, Manuel Raimann, Marc Münker, Maxim Rosin, Joaquin E. Urrutia Gómez, Christof M. Niemeyer, Markus Reischl, Luca Rettenberger

    Large Language Model chatbots have gained significant popularity, offering knowledge to support specialists in diverse fields. However, adapting models to specific use cases and specialized domains presents considerable challenges. Hence, we introduce the LLM Playground, a comprehensive approach to optimizing LLMs for specialist applications with respect to their accuracy in answering domain‐specific questions, addressing the limitations of unmodified models. The utilized optimization techniques begin with Prompt Engineering, advance to the integration of external knowledge, and culminate in complex reasoning strategies or self‐feedback loops. This paper introduces various architectures for scientific assistants, comprising individual enhancement techniques, both in isolation and in combination with others, designed to facilitate comparisons. To demonstrate the efficacy of the LLM Playground, a chemical chatbot is set up as a case study, and the optimization techniques are compared using ChemBench, an independent question–answer benchmark for the chemical domain, to measure its performance. By providing tested, ready‐to‐deploy architectures and clear use‐case guidance, this work helps researchers and practitioners leverage LLMs in domain‐specific applications. The insights and methodologies presented in this paper contribute to the growing body of knowledge on tailoring LLMs to meet the unique demands of specialized fields.

  • Open Access

    Bayesian Optimization for Design Parameters of 3D Image Data Analysis

    by David Exler, Joaquin Eduardo Urrutia Gómez, Martin Krüger, Maike Schliephake, John Jbeily, Mario Vitacolonna, Rüdiger Rudolf, Markus Reischl

    Deep learning-based segmentation and classification are crucial to large-scale biomedical imaging, particularly for 3D data, where manual analysis is impractical. Although many methods exist, selecting suitable models and tuning parameters remains a major bottleneck in practice. Hence, we introduce the 3D data Analysis Optimization Pipeline, a method designed to facilitate the design and parameterization of segmentation and classification using two Bayesian Optimization stages. First, the pipeline selects a segmentation model and optimizes postprocessing parameters using a domain-adapted syntactic benchmark dataset. To ensure a concise evaluation of segmentation performance, we introduce a segmentation quality metric that serves as the objective function. Second, the pipeline optimizes design choices of a classifier, such as encoder and classifier head architectures, incorporation of prior knowledge, and pretraining strategies. To reduce manual annotation effort, this stage includes an assisted class-annotation workflow that extracts predicted instances from the segmentation results and sequentially presents them to the operator, eliminating the need for manual tracking. In four case studies, the 3D data Analysis Optimization Pipeline efficiently identifies effective model and parameter configurations for individual datasets.

  • Open Access

    A review on the advances in non-application specific laboratory automation

    by Aziza El Hariry, Maxim Polomoshnov, Joaquin Eduardo Urrutia Gómez, Felix Zellner, Rüdiger Bauer, Adrian O'HEa, Kolja A. Bartscherer, Markus Reischl


  • Open Access

    Droplet Microarrays for Miniaturized and High‐Throughput Experiments: Progress and Prospectives

    by D.D. Kartsev, Urrutia Gómez Joaquin E, Popova A. Anna, Pavel A. Levkin

    Miniaturization in life sciences and chemical sciences offers substantial advantages to experimental workflows, such as increased throughput, reduced costs, and lower environmental impact. While microtiter plates are effective, further miniaturization is necessary to enhance efficiency and throughput. However, microtiter plates cannot be easily miniaturized to volumes below 5 µL, primarily because adhesive and capillary forces become stronger than the gravitational forces needed to confine the liquid within the wells. To overcome this, the droplet microarray (DMA) is developed, utilizing patterned adhesive regions on a liquid‐repellent background to immobilize and confine sub‐microliter droplets without physical barriers. This unique format enables novel applications such as droplet merging and parallel ultra‐high‐throughput manipulations. This review provides an overview of DMA's diverse applications and highlights the new experimental opportunities it offers, establishing it as a versatile tool for highly miniaturized, high‐throughput biological and chemical experiments. The evolving requirements and future applications of the DMA approach are also discussed.


  • Open Access

    Highly Parallel and High‐Throughput Nanoliter‐Scale Liquid, Cell, and Spheroid Manipulation on Droplet Microarray

    by Joaquin E. Urrutia Gómez, Meijun Zhou, Nikolaj K. Mandsberg, Julian A. Serna, Julius von Padberg, Sida Liu, Markus Reischl, Pavel A. Levkin, Anna A. Popova

    The droplet microarray (DMA) platform is a powerful tool for high‐throughput biological and chemical applications, enabling miniaturization and parallelization of experimental processes. Capable of holding hundreds of nanoliter droplets, it facilitates the screening and analysis of samples, such as cells, bacteria, embryos, and spheroids. Handling thousands of small volumes in parallel presents significant challenges. In this study, we utilize the open format of the DMA for controlled, parallel high‐throughput liquid manipulations using the sandwich technique. We demonstrate high‐throughput medium replacement at nanoliter‐scale, maintaining high cell viability on DMA for up to 7 days; for HeLa‐CLL2 cells (adherent) and SU‐DHL4 cells (suspension), and up to 14 days for HEK293 spheroids. Additionally, we achieve highly parallel aliquot uptake from nanoliter droplets, enabling non‐destructive cell viability assessments. Furthermore, the presented method enables the parallel transfer of cell spheroids between different DMAs, allowing transfer and pooling of spheroids in seconds without damage. These advances significantly enhance the capabilities of the DMA platform, enabling long‐term cell culture in nanoliter droplets and parallel sampling for high‐throughput cell or spheroid manipulation. This broadens the scope of DMA's potential applications in fields such as cell‐based high‐throughput screening, formation of complex 3D cell models for drug screening, and microtissue engineering.


  • Open Access

    Electrode Droplet Microarray (eDMA): An Impedance Platform for Label‐Free Parallel Monitoring of Cellular Drug Response in Nanoliter Droplets

    by Meijun Zhou, Joaquin E. Urrutia Gomez, Nikolaj K. Mandsberg, Sida Liu, Sabine Schmidt, Matthias Meier, Pavel A. Levkin, Heinz‐Georg Jahnke, Anna Popova

    Label‐free real‐time monitoring of cellular behavior using impedance spectroscopy is important for drug development and toxicological assessments. Parallelization and miniaturization of such experiments are essential for increasing throughput and enabling experiments with low abundant stem or primary cells. Traditional methods are not miniaturized and require large volumes of reagents and number of cells, limiting their suitability for cost effective high‐throughput screening of cells of limited availability. Here, the fabrication, optimization, and application of a bioelectrical signaling monitoring system – electrode droplet microarray (eDMA) are demonstrated. The eDMA platform is based on preparation of a hydrophilic‐superhydrophobic patterns covering an array of individually addressable microelectrodes, which confines cells to individual microelectrodes, allowing for parallel, real‐time, and label‐free detection of cellular responses to drug treatments in nanoliter droplets. The real‐time monitoring of cytotoxic effect of an anticancer drug is demonstrated over 48 h with real‐time calculation of the half‐inhibitory concentration (IC50) values through impedance spectroscopy. This demonstrates eDMA's ability to dynamically assess responses to various drugs in parallel at any given time point, which is crucial for functional personalized oncology. Specifically, the platform can be employed for monitoring anticancer drug toxicity using limited patient samples, where the miniaturization provided by eDMA is essential.


  • Open Access

    Enhancing Temperature Responsiveness of PNIPAM Through 3D‐Printed Hierarchical Porosity

    by Weiyi Liu, Zhenwu Wang, Julian A. Serna, Rafaela Debastiani, Joaquin E. Urrutia Gomez, Lutong Lu, Wenwu Yang, Zheqin Dong, Pavel A. Levkin

    Materials with ultra‐fast responsive properties are essential for various applications. Among the responsive materials, poly(N‐isopropylacrylamide) (PNIPAM) stands out due to its well‐studied temperature‐responsive properties. Improving the kinetics of the responsive properties of PNIPAM is, however, still essential for advancing its practical use. Here, the responsive rate of PNIPAM hydrogels is enhanced by first incorporating sub‐micrometer porosity into the material through polymerization‐induced phase separation (PIPS), followed by introducing millimeter scale pores via 3D printing, thereby rendering the material with hierarchical porosity. The 3D‐printed porous PNIPAM structures show accelerated swelling and deswelling, when compared to non‐porous PNIPAM structures, due to enhanced water permeability associated with the continuous network of micrometer to millimeter‐sized pores. Additionally, thinner polymer structures result in faster temperature response rates. At the same time, the mechanical strength of PNIPAM hydrogels with high porosity and thinner polymer walls is not compromised, overcoming the common trade‐off between swelling and mechanical properties.


  • Front Cover, Volume 3, Number 1, January 2024

    by Yanchen Wu, Joaquin E. Urrutia Gomez, Hongmin Zhang, Fei Wang, Pavel A. Levkin, Anna A. Popova, Britta Nestler


  • Open Access

    Digital twin of a droplet microarray platform: Evaporation behavior for multiple droplets on patterned chips for cell culture

    by Yanchen Wu, Joaquin E. Urrutia Gomez, Hongmin Zhang, Fei Wang, Pavel A. Levkin, Anna A. Popova, Britta Nestler

    Precise control of the evaporation of multiple droplets on patterned surfaces is crucial in many technological applications, such as anti‐icing, coating, and high‐throughput assays. Yet, the complex evaporation process of multiple droplets on well‐defined patterned surfaces is still poorly understood. Herein, we develop a digital twin system for real‐time monitoring of key processes on a droplet microarray (DMA), which is essential for parallelization and automation of the operations for cell culture. Specifically, we investigate the evaporation of multiple nanoliter droplets under different conditions via experiments and numerical simulations. We demonstrate that the evaporation rate is not only affected by the environmental humidity and temperature but is also strongly linked to the droplet distribution on the patterned surfaces, being significantly reduced when the droplets are densely distributed. Furthermore, we propose a theoretical method to aid in the experimental detection of volumes and pH variation of evaporating droplets on patterned substrates. This versatile and practical strategy allows us to achieve active maneuvering of the collective evaporation of droplets on a DMA, which provides essential implications for a wide range of applications including cell culture, heat management, microreactors, biochips, and so on.