Yayoi N. Miura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yayoi N. Miura has a total of 320 co-authors. Here are the top co-authors by number of shared publications:
- Yoshinori Takano
Biogeochemistry Research Center (BGC), Japan Agency for Marine-Earth Science and Technology (JAMSTEC), Yokosuka, Japan
9 shared publications - Seiji Sugita
Department of Earth and Planetary Science, The University of Tokyo, Bunkyo, Tokyo, Japan
8 shared publications - Shogo Tachibana
The University of Tokyo
8 shared publications - Tomohiro Usui
Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, Sagamihara, Japan
8 shared publications - Yuichiro Cho
Department of Earth and Planetary Science, The University of Tokyo, Bunkyo, Tokyo, Japan
7 shared publications - Aiko Nakato
Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, Sagamihara, Japan
6 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 7 (2) , 39
Dating Young, Low-K Martian Meteorites with an In Situ K–Ar Isochron Technique for Mars Missions
Accurate age determination is fundamental to advancing our understanding of planetary evolution. While sample-return missions provide the most accurate age measurements, in situ methods via one-way missions offer a significantly lower-cost alternative, enabling more frequent mission opportunities. The K–Ar isochron method, which combines spot-by-spot analysis using laser-induced breakdown spectroscopy (LIBS) for K and mass spectrometry (MS) for Ar, shows promise for in situ age dating since LIBS and MS have been used in planetary missions. Previous studies analyzed K-rich terrestrial rocks and chondrites using this LIBS–MS method. Martian meteorites, the only available samples of Martian rocks, are crucial for validating this technique for Mars missions. However, their low K concentrations and young ages have precluded measurements using this method. To overcome these challenges, we updated a LIBS–MS instrument for in situ K–Ar dating and applied it to three Martian meteorites: NWA 817, Zagami, and NWA 1068. We obtained isochron ages of 1351 ± 337 Ma, 165 ± 74 Ma, and 122 ± 163 Ma (2 σ ), respectively, in agreement with previously reported crystallization ages. The amounts of nonradiogenic 40 Ar estimated using the y -intercept on the isochron plot are also consistent with those of previous studies. Our results suggest that this instrument is sufficiently precise to calibrate Martian crater age models and determine the absolute ages of young volcanic activity on Mars in the Amazonian period.
- 1 February 2026
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 7 (2) , 39
Open AccessDating Young, Low-K Martian Meteorites with an In Situ K–Ar Isochron Technique for Mars Missions
Accurate age determination is fundamental to advancing our understanding of planetary evolution. While sample-return missions provide the most accurate age measurements, in situ methods via one-way missions offer a significantly lower-cost alternative, enabling more frequent mission opportunities. The K–Ar isochron method, which combines spot-by-spot analysis using laser-induced breakdown spectroscopy (LIBS) for K and mass spectrometry (MS) for Ar, shows promise for in situ age dating since LIBS and MS have been used in planetary missions. Previous studies analyzed K-rich terrestrial rocks and chondrites using this LIBS–MS method. Martian meteorites, the only available samples of Martian rocks, are crucial for validating this technique for Mars missions. However, their low K concentrations and young ages have precluded measurements using this method. To overcome these challenges, we updated a LIBS–MS instrument for in situ K–Ar dating and applied it to three Martian meteorites: NWA 817, Zagami, and NWA 1068. We obtained isochron ages of 1351 ± 337 Ma, 165 ± 74 Ma, and 122 ± 163 Ma (2 σ ), respectively, in agreement with previously reported crystallization ages. The amounts of nonradiogenic 40 Ar estimated using the y -intercept on the isochron plot are also consistent with those of previous studies. Our results suggest that this instrument is sufficiently precise to calibrate Martian crater age models and determine the absolute ages of young volcanic activity on Mars in the Amazonian period.
- Open Access
- 1 January 2026
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 60 (3) , 71-81
Neon permeation experiments using a polyimide sheet at low temperatures: Towards in situ Martian atmospheric Ne measurements
The compositions of planetary atmospheres provide key constraints on the origin and evolution of the planets. Mars has a thin atmosphere dominated by CO2, with Ne detected by the Viking mission, although its abundance and isotopic composition is not well defined. A major technical challenge for in situ Ne measurements on Mars is to separate Ne from Ar before mass spectrometry, because 40Ar2+ interferes with 20Ne+. Previous studies have demonstrated that Ne–Ar separation can be achieved using polyimide membranes. In order to characterize the temperature dependence of permeation relevant to Martian mission, we investigated gas permeation through a 100-µm-thick polyimide sheet at 6 °C, −18 °C, and −38 °C, and measured the permeated He, Ne, and Ar amounts, as well as 20Ne/22Ne ratio. The amounts of permeated He and Ne decrease with decreasing temperature. At −38 °C, the permeated 4He and 20Ne amounts are lower than the room temperature values by factors of ~6 and ~7, respectively. No permeated 40Ar above background level was detected. The 20Ne/22Ne ratios corrected for mass-dependent fractionation agree with the terrestrial atmospheric ratio within analytical uncertainty, except during initial non-steady-state permeation at −38 °C. Temperature dependency of permeated amounts indicates that the permeation fluxes through a 100-µm-thick polyimide at 20 °C give 2.2 × 10−11 and 2.7 × 10−12 cm3STP/sec/cm2/Pa for 4He and 20Ne, respectively. Under Martian atmospheric pressure, permeation through a 100-µm-thick polyimide for 40–60 min at temperature between ~10 °C and room temperature provides a Ne amount of 1–2 × 10−9 cm3STP/100 cm2 with effective Ne-Ar separation.
- 1 January 2026
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 60 (3) , 71-81
Open AccessNeon permeation experiments using a polyimide sheet at low temperatures: Towards in situ Martian atmospheric Ne measurements
The compositions of planetary atmospheres provide key constraints on the origin and evolution of the planets. Mars has a thin atmosphere dominated by CO2, with Ne detected by the Viking mission, although its abundance and isotopic composition is not well defined. A major technical challenge for in situ Ne measurements on Mars is to separate Ne from Ar before mass spectrometry, because 40Ar2+ interferes with 20Ne+. Previous studies have demonstrated that Ne–Ar separation can be achieved using polyimide membranes. In order to characterize the temperature dependence of permeation relevant to Martian mission, we investigated gas permeation through a 100-µm-thick polyimide sheet at 6 °C, −18 °C, and −38 °C, and measured the permeated He, Ne, and Ar amounts, as well as 20Ne/22Ne ratio. The amounts of permeated He and Ne decrease with decreasing temperature. At −38 °C, the permeated 4He and 20Ne amounts are lower than the room temperature values by factors of ~6 and ~7, respectively. No permeated 40Ar above background level was detected. The 20Ne/22Ne ratios corrected for mass-dependent fractionation agree with the terrestrial atmospheric ratio within analytical uncertainty, except during initial non-steady-state permeation at −38 °C. Temperature dependency of permeated amounts indicates that the permeation fluxes through a 100-µm-thick polyimide at 20 °C give 2.2 × 10−11 and 2.7 × 10−12 cm3STP/sec/cm2/Pa for 4He and 20Ne, respectively. Under Martian atmospheric pressure, permeation through a 100-µm-thick polyimide for 40–60 min at temperature between ~10 °C and room temperature provides a Ne amount of 1–2 × 10−9 cm3STP/100 cm2 with effective Ne-Ar separation.
- Open Access
- 10 December 2025
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 413, 218-232
An I-Xe age 8 Myr after solar system formation in a Hayabusa2 sample records alteration on the parent planetesimal of asteroid Ryugu
- 10 December 2025
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 413, 218-232
Open AccessAn I-Xe age 8 Myr after solar system formation in a Hayabusa2 sample records alteration on the parent planetesimal of asteroid Ryugu
- Open Access
- 7 August 2025
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 60 (9) , 2076-2098
Feasibility of in situ K‐Ar isochron dating on Mars: Assessment using the mineralogy of Martian meteorites
Dating rocks with a 2σ precision of 200 Ma is required to understand the history of Martian habitability and volcanic activity since ~4000 Ma. In situ K‐Ar dating using a spot‐by‐spot laser ablation technique has been developed for isochron dating on Mars. The precision of isochron ages is determined mainly by the relationship between the laser spot diameter and the grain size of the sample. However, the achievable precision of age estimates using a realistic mineralogy of Martian rocks has yet to be investigated. We simulated isochrons under various conditions, including different laser spot sizes, K and Ar measurement errors, and numbers of analyses based on the mineral abundances of representative Martian meteorites (NWA 817, Zagami, and NWA 1068) analyzed using an electron probe microanalyzer. We found that attaining a precision of 200 Ma necessitates an isochron data range, defined as the ratio of the maximum to minimum K concentrations, of >6, a laser spot diameter of 250 μm, and measurement errors of <10% for both K and Ar. Reducing the laser spot size and selecting a sample with a large grain size are effective in obtaining a large K range. Furthermore, minimizing the variance in measurement errors between K and Ar is essential to increase the accuracy of the age estimates. We demonstrate that the precision required for in situ dating on Mars is achievable with realistic instrument settings, thus demonstrating the feasibility of establishing an in situ K‐Ar geochronology for Mars.
- 7 August 2025
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 60 (9) , 2076-2098
Open AccessFeasibility of in situ K‐Ar isochron dating on Mars: Assessment using the mineralogy of Martian meteorites
Dating rocks with a 2σ precision of 200 Ma is required to understand the history of Martian habitability and volcanic activity since ~4000 Ma. In situ K‐Ar dating using a spot‐by‐spot laser ablation technique has been developed for isochron dating on Mars. The precision of isochron ages is determined mainly by the relationship between the laser spot diameter and the grain size of the sample. However, the achievable precision of age estimates using a realistic mineralogy of Martian rocks has yet to be investigated. We simulated isochrons under various conditions, including different laser spot sizes, K and Ar measurement errors, and numbers of analyses based on the mineral abundances of representative Martian meteorites (NWA 817, Zagami, and NWA 1068) analyzed using an electron probe microanalyzer. We found that attaining a precision of 200 Ma necessitates an isochron data range, defined as the ratio of the maximum to minimum K concentrations, of >6, a laser spot diameter of 250 μm, and measurement errors of <10% for both K and Ar. Reducing the laser spot size and selecting a sample with a large grain size are effective in obtaining a large K range. Furthermore, minimizing the variance in measurement errors between K and Ar is essential to increase the accuracy of the age estimates. We demonstrate that the precision required for in situ dating on Mars is achievable with realistic instrument settings, thus demonstrating the feasibility of establishing an in situ K‐Ar geochronology for Mars.
- Open Access
- 1 August 2024
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 5 (8) , 187
Validation Experiments for In Situ Ne Isotope Analysis on Mars: Gas Separation Flange Assembly Using Polyimide Membrane and Metal Seal
The Martian atmospheric Ne may reflect recent gas supply from its mantle via volcanic degassing, due to its short (∼100 Myr) escape timescale. The isotopic ratio of the Martian atmospheric Ne would therefore provide insights into that of the Martian mantle, further suggesting the origin of Mars volatiles during planetary formation. Mass spectrometric analysis of the Martian atmospheric Ne, however, has faced challenges from interference between 20Ne+ and 40Ar++. Previous studies using a polyimide membrane for 20Ne/40Ar separation were limited by the drawbacks of elastomeric O-rings to support the membrane, such as low-temperature intolerance, outgassing, and the need to endure environmental conditions during the launch and before/after landing on Mars. This study proposes a new method employing a metal C-ring to secure a 100 μm polyimide sheet within vacuum flanges. Environmental tests, including vibration, shock, extreme temperatures, and radiation exposure, were conducted on the gas separation flanges. Pre- and post-test analyses for He, Ne, and Ar demonstrated the membrane-flange system’s resilience. Gas permeation measurements using terrestrial air effectively permeated 4He and 20Ne, while reducing 40Ar by more than six orders of magnitude. This study achieved a 20Ne/22Ne ratio, sufficient for assessing the origins of Ne in the Martian mantle. Furthermore, experiments with a 590 Pa gas mixture simulating the Martian atmosphere achieved a 10% accuracy for the 20Ne/22Ne isotope ratio, with gas abundances consistent with numerical predictions based on individual partial pressures. These results validate the suitability of the developed polyimide membrane assembly for in situ Martian Ne analyses.
- 1 August 2024
- Published by American Astronomical Society in The Planetary Science Journal
- Vol. 5 (8) , 187
Open AccessValidation Experiments for In Situ Ne Isotope Analysis on Mars: Gas Separation Flange Assembly Using Polyimide Membrane and Metal Seal
The Martian atmospheric Ne may reflect recent gas supply from its mantle via volcanic degassing, due to its short (∼100 Myr) escape timescale. The isotopic ratio of the Martian atmospheric Ne would therefore provide insights into that of the Martian mantle, further suggesting the origin of Mars volatiles during planetary formation. Mass spectrometric analysis of the Martian atmospheric Ne, however, has faced challenges from interference between 20Ne+ and 40Ar++. Previous studies using a polyimide membrane for 20Ne/40Ar separation were limited by the drawbacks of elastomeric O-rings to support the membrane, such as low-temperature intolerance, outgassing, and the need to endure environmental conditions during the launch and before/after landing on Mars. This study proposes a new method employing a metal C-ring to secure a 100 μm polyimide sheet within vacuum flanges. Environmental tests, including vibration, shock, extreme temperatures, and radiation exposure, were conducted on the gas separation flanges. Pre- and post-test analyses for He, Ne, and Ar demonstrated the membrane-flange system’s resilience. Gas permeation measurements using terrestrial air effectively permeated 4He and 20Ne, while reducing 40Ar by more than six orders of magnitude. This study achieved a 20Ne/22Ne ratio, sufficient for assessing the origins of Ne in the Martian mantle. Furthermore, experiments with a 590 Pa gas mixture simulating the Martian atmosphere achieved a 10% accuracy for the 20Ne/22Ne isotope ratio, with gas abundances consistent with numerical predictions based on individual partial pressures. These results validate the suitability of the developed polyimide membrane assembly for in situ Martian Ne analyses.
- Open Access
- 11 January 2024
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 59 (2) , 321-337
Curation protocol of Phobos sample returned by Martian Moons eXploration
Japan Aerospace Exploration Agency's Martian Moons eXploration (MMX) mission will launch a spacecraft in 2024 to return samples from Phobos in 2029. Curatorial work for the returned Phobos samples is critical for the sample allocation without degrading the sample integrity and subsequent sample analysis that will provide new constraints on the origin of Phobos and the evolution of the circum‐Mars environment. The Sample Analysis Working Team of the MMX is designing the sample curation protocol. The curation protocol consists of three phases: (1) quick analysis (extraction and mass spectrometry for gases), (2) pre‐basic characterization (bulk‐scale observation), and (3) basic characterization (grain‐by‐grain observation and allocation of the sample aliquots). Nondestructive analyses within the clean chamber (e.g., visible and near‐infrared spectral imaging) and outside the chamber (e.g., gas mass spectrometry) are incorporated into the curation flow in coordination with the MMX mission instrument teams for ground‐truthing the remote‐sensing data sets. The MMX curation/sample analysis flow enables the seamless integration between the sample and remote‐sensing data sets to maximize the scientific value of the collected Phobos samples.
- 11 January 2024
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 59 (2) , 321-337
Open AccessCuration protocol of Phobos sample returned by Martian Moons eXploration
Japan Aerospace Exploration Agency's Martian Moons eXploration (MMX) mission will launch a spacecraft in 2024 to return samples from Phobos in 2029. Curatorial work for the returned Phobos samples is critical for the sample allocation without degrading the sample integrity and subsequent sample analysis that will provide new constraints on the origin of Phobos and the evolution of the circum‐Mars environment. The Sample Analysis Working Team of the MMX is designing the sample curation protocol. The curation protocol consists of three phases: (1) quick analysis (extraction and mass spectrometry for gases), (2) pre‐basic characterization (bulk‐scale observation), and (3) basic characterization (grain‐by‐grain observation and allocation of the sample aliquots). Nondestructive analyses within the clean chamber (e.g., visible and near‐infrared spectral imaging) and outside the chamber (e.g., gas mass spectrometry) are incorporated into the curation flow in coordination with the MMX mission instrument teams for ground‐truthing the remote‐sensing data sets. The MMX curation/sample analysis flow enables the seamless integration between the sample and remote‐sensing data sets to maximize the scientific value of the collected Phobos samples.
- 24 February 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 379 (6634) , 788-U52
Noble gases and nitrogen in samples of asteroid Ryugu record its volatile sources and recent surface evolution
The near-Earth carbonaceous asteroid (162173) Ryugu is expected to contain volatile chemical species that could provide information on the origin of Earth’s volatiles. Samples of Ryugu were retrieved by the Hayabusa2 spacecraft. We measured noble gas and nitrogen isotopes in Ryugu samples and found that they are dominated by presolar and primordial components, incorporated during Solar System formation. Noble gas concentrations are higher than those in Ivuna-type carbonaceous (CI) chondrite meteorites. Several host phases of isotopically distinct nitrogen have different abundances among the samples. Our measurements support a close relationship between Ryugu and CI chondrites. Noble gases produced by galactic cosmic rays, indicating a ~5 million year exposure, and from implanted solar wind record the recent irradiation history of Ryugu after it migrated to its current orbit.
- 24 February 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 379 (6634) , 788-U52
Noble gases and nitrogen in samples of asteroid Ryugu record its volatile sources and recent surface evolution
The near-Earth carbonaceous asteroid (162173) Ryugu is expected to contain volatile chemical species that could provide information on the origin of Earth’s volatiles. Samples of Ryugu were retrieved by the Hayabusa2 spacecraft. We measured noble gas and nitrogen isotopes in Ryugu samples and found that they are dominated by presolar and primordial components, incorporated during Solar System formation. Noble gas concentrations are higher than those in Ivuna-type carbonaceous (CI) chondrite meteorites. Several host phases of isotopically distinct nitrogen have different abundances among the samples. Our measurements support a close relationship between Ryugu and CI chondrites. Noble gases produced by galactic cosmic rays, indicating a ~5 million year exposure, and from implanted solar wind record the recent irradiation history of Ryugu after it migrated to its current orbit.
- Open Access
- 26 January 2023
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 345, 62-74
The noble gas and nitrogen relationship between Ryugu and carbonaceous chondrites
- 26 January 2023
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 345, 62-74
Open AccessThe noble gas and nitrogen relationship between Ryugu and carbonaceous chondrites
- Open Access
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eabo7239
First asteroid gas sample delivered by the Hayabusa2 mission: A treasure box from Ryugu
The Hayabusa2 spacecraft returned to Earth from the asteroid 162173 Ryugu on 6 December 2020. One day after the recovery, the gas species retained in the sample container were extracted and measured on-site and stored in gas collection bottles. The container gas consists of helium and neon with an extraterrestrial 3 He/ 4 He and 20 Ne/ 22 Ne ratios, along with some contaminant terrestrial atmospheric gases. A mixture of solar and Earth’s atmospheric gas is the best explanation for the container gas composition. Fragmentation of Ryugu grains within the sample container is discussed on the basis of the estimated amount of indigenous He and the size distribution of the recovered Ryugu grains. This is the first successful return of gas species from a near-Earth asteroid.
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eabo7239
Open AccessFirst asteroid gas sample delivered by the Hayabusa2 mission: A treasure box from Ryugu
The Hayabusa2 spacecraft returned to Earth from the asteroid 162173 Ryugu on 6 December 2020. One day after the recovery, the gas species retained in the sample container were extracted and measured on-site and stored in gas collection bottles. The container gas consists of helium and neon with an extraterrestrial 3 He/ 4 He and 20 Ne/ 22 Ne ratios, along with some contaminant terrestrial atmospheric gases. A mixture of solar and Earth’s atmospheric gas is the best explanation for the container gas composition. Fragmentation of Ryugu grains within the sample container is discussed on the basis of the estimated amount of indigenous He and the size distribution of the recovered Ryugu grains. This is the first successful return of gas species from a near-Earth asteroid.
- Open Access
- 24 May 2022
- Published by Springer Nature in Earth, Planets and Space
- Vol. 74 (1) , 1-17
The GAs Extraction and Analyses system (GAEA) for immediate extraction and measurements of volatiles in the Hayabusa2 sample container
Hayabusa2 returned surface samples from the C-type near-Earth asteroid (162173) Ryugu to Woomera, South Australia, in December 2020. The samples returned from Ryugu are expected to contain not only volatile components reflecting its primitive nature, but also solar wind components due to exposure to space. Such volatiles may partly be released inside the sealed sample container enclosing Ryugu samples due to particle destruction or container heating in a contingency case. In order to collect and analyze volatiles released in the container prior to the container-opening, we set up a gas extraction and analyses system (GAEA: GAs Extraction and Analyses system). The system requires ultra-high vacuum conditions, small vacuum line volume to minimize dead volume and simple configuration as well as having an interface to connect the container. The system includes gas bottles for passive collection of volatiles at room temperature and bottles for active collection at liquid nitrogen temperature. A quadrupole mass spectrometer is installed to analyze gases in the vacuum line, and a non-evaporative getter pump is also used when noble gases are analyzed. The rehearsal operation of the GAEA was made at ISAS/JAXA as well as transportation tests in Japan. In November 2020, it was transported safely to the Quick Look Facility (QLF) in Woomera. It was set up at the QLF and worked as planned for collection and analysis of gas components from the returned sample container. Here we report the concept, design and calibration results for the GAEA and an outline of analytical protocols applied in Woomera. Graphical Abstract
- 24 May 2022
- Published by Springer Nature in Earth, Planets and Space
- Vol. 74 (1) , 1-17
Open AccessThe GAs Extraction and Analyses system (GAEA) for immediate extraction and measurements of volatiles in the Hayabusa2 sample container
Hayabusa2 returned surface samples from the C-type near-Earth asteroid (162173) Ryugu to Woomera, South Australia, in December 2020. The samples returned from Ryugu are expected to contain not only volatile components reflecting its primitive nature, but also solar wind components due to exposure to space. Such volatiles may partly be released inside the sealed sample container enclosing Ryugu samples due to particle destruction or container heating in a contingency case. In order to collect and analyze volatiles released in the container prior to the container-opening, we set up a gas extraction and analyses system (GAEA: GAs Extraction and Analyses system). The system requires ultra-high vacuum conditions, small vacuum line volume to minimize dead volume and simple configuration as well as having an interface to connect the container. The system includes gas bottles for passive collection of volatiles at room temperature and bottles for active collection at liquid nitrogen temperature. A quadrupole mass spectrometer is installed to analyze gases in the vacuum line, and a non-evaporative getter pump is also used when noble gases are analyzed. The rehearsal operation of the GAEA was made at ISAS/JAXA as well as transportation tests in Japan. In November 2020, it was transported safely to the Quick Look Facility (QLF) in Woomera. It was set up at the QLF and worked as planned for collection and analysis of gas components from the returned sample container. Here we report the concept, design and calibration results for the GAEA and an outline of analytical protocols applied in Woomera. Graphical Abstract