Daniela Ribas Jané
Research Subjects
Daniela Ribas Jané has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Beatriz Perez Floriano
Universidade Federal de Santa Maria (UFSM), Santa Maria, RS, Brazil
2 shared publications - Nazilton de Paula Reis Filho
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Brasil
2 shared publications - Thomas Alexander Trein
UNESP, Brazil
2 shared publications - Andressa Rodrigues de Souza
Federal University of Santa Maria (UFSM) , Postgraduate student at the Department of Small Animal Clinic , Rio Grande do Sul State , Brazil
1 shared publication - André Vasconcelos Soares
Federal University of Santa Maria (UFSM) , Center for Rural Sciences, Department of Small Animal Clinic , Santa Maria , RS , Brazil
1 shared publication - Anna Luiza Zavataro
Centro Universitário de Ourinhos (Unifio), Brasil
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 56 (1)
Blind perineural injection for sciatic and femoral nerve block in cats: anatomical study and in vivo application
This study investigated staining of sciatic (SN) and femoral (FN) nerves in feline cadavers following injection of two different volumes of methylene blue, and the application of one chosen volume in vivo using lidocaine in healthy sedated cats. Fourteen adult feline cadavers weighing 2.8 ± 1.2 kg and 10 healthy adult cats weighing 3.5 ± 1.2 kg were used in the study. First, an anatomical study of the SN and FN was carried out on six feline cadavers to measure depth of each nerve, followed by injection of 1% methylene blue on another eight cadavers to compare 0.2 with 0.3 mL/kg on each pelvic limb. The volume associated with staining ≥ 2 cm of the nerves was considered adequate for application in vivo. Based on the cadaveric study, 10 healthy cats received 1.25% lidocaine on one side and saline on the contralateral side at 0.2 mL/kg to assess efficacy of perineural block. Injections were performed between the semimembranosus and semitendinosus muscles for the SN and in the femoral triangle, next to the iliopsoas muscle, for the FN. Motor assessment included a score of ataxia and patellar reflex testing. Sensory assessment comprised proprioception and skin clamping at the leg. Data were analyzed using paired t test. Results showed insufficient in vivo block, demonstrated by lack of difference between sides (P > 0.05). In conclusion, SN and FN block cannot be successfully performed in cats without the aid of imaging modalities or neurostimulation using low volumes of solution (0.2 mL/kg).
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 56 (1)
Open AccessBlind perineural injection for sciatic and femoral nerve block in cats: anatomical study and in vivo application
This study investigated staining of sciatic (SN) and femoral (FN) nerves in feline cadavers following injection of two different volumes of methylene blue, and the application of one chosen volume in vivo using lidocaine in healthy sedated cats. Fourteen adult feline cadavers weighing 2.8 ± 1.2 kg and 10 healthy adult cats weighing 3.5 ± 1.2 kg were used in the study. First, an anatomical study of the SN and FN was carried out on six feline cadavers to measure depth of each nerve, followed by injection of 1% methylene blue on another eight cadavers to compare 0.2 with 0.3 mL/kg on each pelvic limb. The volume associated with staining ≥ 2 cm of the nerves was considered adequate for application in vivo. Based on the cadaveric study, 10 healthy cats received 1.25% lidocaine on one side and saline on the contralateral side at 0.2 mL/kg to assess efficacy of perineural block. Injections were performed between the semimembranosus and semitendinosus muscles for the SN and in the femoral triangle, next to the iliopsoas muscle, for the FN. Motor assessment included a score of ataxia and patellar reflex testing. Sensory assessment comprised proprioception and skin clamping at the leg. Data were analyzed using paired t test. Results showed insufficient in vivo block, demonstrated by lack of difference between sides (P > 0.05). In conclusion, SN and FN block cannot be successfully performed in cats without the aid of imaging modalities or neurostimulation using low volumes of solution (0.2 mL/kg).
- Open Access
- 1 January 2025
- Published by Wiley in Veterinary Medicine International
- Vol. 2025 (1) , 5516116
Comparison Between Radiographic Vertebral Left Atrial Size (VLAS) and Echocardiographic Methods for Predicting Left Atrial Remodeling in Dogs With Mitral Valve Disease
Objective: To investigate whether there is a positive correlation between vertebral left atrial size (VLAS) and echocardiographic variables—left atrium‐to‐aorta ratio (LA/Ao), left ventricular fractional shortening (FS), left ventricular internal diameter in diastole normalized to body weight (LVIDdn), and left ventricular early filling velocity (E‐wave)—and the Mitral INsufficiency Echocardiographic (MINE) echocardiographic score. Study Design: Prospective randomized blinded study. Animals: A total of 26 dogs. Methods: Dogs diagnosed with MVD participated in the study. All patients underwent radiographic and echocardiographic evaluation. Results: A high correlation strength could be observed between the left atrial enlargement predictor VLAS and the LA/Ao ratio (88%), as well as with LVIDdn (75%) and E‐wave (74%). Furthermore, a correction strength of 84% was verified between VLAS and the MINE score. The analysis of the FS variable did not demonstrate a statistically significant relationship ( p value of 0.06). Conclusions and Clinics Relevance: VLAS has a positive relationship and important correlation with the echocardiographic variables and MINE score. Associated with its higher accessibility in clinical routine is a potential diagnostic method to detect left atrial enlargement in dogs, contributing to the diagnostic conduct in DVM.
- 1 January 2025
- Published by Wiley in Veterinary Medicine International
- Vol. 2025 (1) , 5516116
Open AccessComparison Between Radiographic Vertebral Left Atrial Size (VLAS) and Echocardiographic Methods for Predicting Left Atrial Remodeling in Dogs With Mitral Valve Disease
Objective: To investigate whether there is a positive correlation between vertebral left atrial size (VLAS) and echocardiographic variables—left atrium‐to‐aorta ratio (LA/Ao), left ventricular fractional shortening (FS), left ventricular internal diameter in diastole normalized to body weight (LVIDdn), and left ventricular early filling velocity (E‐wave)—and the Mitral INsufficiency Echocardiographic (MINE) echocardiographic score. Study Design: Prospective randomized blinded study. Animals: A total of 26 dogs. Methods: Dogs diagnosed with MVD participated in the study. All patients underwent radiographic and echocardiographic evaluation. Results: A high correlation strength could be observed between the left atrial enlargement predictor VLAS and the LA/Ao ratio (88%), as well as with LVIDdn (75%) and E‐wave (74%). Furthermore, a correction strength of 84% was verified between VLAS and the MINE score. The analysis of the FS variable did not demonstrate a statistically significant relationship ( p value of 0.06). Conclusions and Clinics Relevance: VLAS has a positive relationship and important correlation with the echocardiographic variables and MINE score. Associated with its higher accessibility in clinical routine is a potential diagnostic method to detect left atrial enlargement in dogs, contributing to the diagnostic conduct in DVM.
- Open Access
- 1 December 2021
- Published by FapUNIFESP (SciELO) in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
- Vol. 73 (6) , 1309-1314
Comparison of two volumes for sciatic perineural injection using 1% methylene blue in rabbit cadavers
The purpose of this study was to assess the efficacy of a blind technique for sciatic and femoral nerve block in rabbit cadavers by evaluating the spread of 1% methylene blue at two different volumes. Nine recently euthanized rabbits weighing 2.5(0.3kg were used. The sciatic (SN) and femoral (FN) nerves of each limb were randomly assigned for injection with 1% methylene blue at 0.2mL/kg (G0.2) or 0.3mL/kg (G0.3). Nerves were dissected and measured for depth and extension of staining (cm). Mean comparisons were performed using paired t test. The relation between volume and nerve staining ( 2cm was assessed using chi-square test. The mean depth of SN was 1.9±0.2 and 1.6±0.3cm and staining 1.9±1.4 and 2.0±1.2cm, respectively in G0.2 and G0.3. No relation was found between depth and dye spread and there was no association between nerve staining ( 2.0cm and volume of solution. The FN failed to be stained in all subjects. In conclusion, SN injection can be successfully performed without guidance in rabbits. The lower volume (0.2mL/kg) is recommended to avoid systemic toxicity.
- 1 December 2021
- Published by FapUNIFESP (SciELO) in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
- Vol. 73 (6) , 1309-1314
Open AccessComparison of two volumes for sciatic perineural injection using 1% methylene blue in rabbit cadavers
The purpose of this study was to assess the efficacy of a blind technique for sciatic and femoral nerve block in rabbit cadavers by evaluating the spread of 1% methylene blue at two different volumes. Nine recently euthanized rabbits weighing 2.5(0.3kg were used. The sciatic (SN) and femoral (FN) nerves of each limb were randomly assigned for injection with 1% methylene blue at 0.2mL/kg (G0.2) or 0.3mL/kg (G0.3). Nerves were dissected and measured for depth and extension of staining (cm). Mean comparisons were performed using paired t test. The relation between volume and nerve staining ( 2cm was assessed using chi-square test. The mean depth of SN was 1.9±0.2 and 1.6±0.3cm and staining 1.9±1.4 and 2.0±1.2cm, respectively in G0.2 and G0.3. No relation was found between depth and dye spread and there was no association between nerve staining ( 2.0cm and volume of solution. The FN failed to be stained in all subjects. In conclusion, SN injection can be successfully performed without guidance in rabbits. The lower volume (0.2mL/kg) is recommended to avoid systemic toxicity.