NTNicole V. Tolan

Nicole V. Tolan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicole V. Tolan has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Preanalytic Considerations for Preventing In Vitro Glycolysis: Practical Recommendations for Fasting and Glucose Tolerance Testing

    by Phillip Kang, Clara E. Wolf, Victoria L. Thomas, Stacy E.F. Melanson, Nicole V. Tolan


  • Open Access

    LC-MS/MS Detection of Tryptophan, Kynurenine, Kynurenic Acid, and Quinolinic Acid in Urine Samples from Drug-Positive and Illicit Drug-Negative Patients with a Known History of Substance Use Disorder

    by Lindsey Contella, Christopher L. Farrell, Luigi Boccuto, Alain H. Litwin, Hunter Flanagan, Stacy E. F. Melanson, Nicole V. Tolan, Marion L. Snyder, Dina N. Greene

    Introduction: Currently, there are few tools for monitoring recovery in substance use disorder. As substance use has increased in prevalence, tools for measuring recovery are needed to improve therapeutic outcomes. Measuring the kynurenine pathway for imbalances in metabolites could be a possible solution to monitor recovery. Methods: We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to quantify tryptophan, kynurenine, kynurenic acid, and quinolinic acid in urine. Metabolites were separated using a stepwise gradient and detected with an Agilent 6460 triple quadrupole mass analyzer. The samples were extracted using a simple protein precipitation protocol. Method validation was performed using routine toxicology urine samples and laboratory contrived samples. The performance characteristics assessed included precision, linearity, stability, interference, and matrix effects. Additionally, urine samples from two cohorts (illicit drug-negative and drug-positive; n = 120 per cohort) were analyzed for significant concentration differences in the four metabolites using Mann–Whitney, PCA, and Area Under the Receiver Operating Characteristic Curve statistical analysis. Results: The LC-MS/MS assay was linear from 195 to 100,000 ng/mL for tryptophan, 6 to 3000 ng/mL for kynurenine, 14 to 7200 ng/mL for kynurenic acid, and 125 to 64,000 ng/mL for quinolinic acid using an 8-point calibration curve. Imprecision ranged from 1.17% to 12.46% CV using two controls that spanned the analytical measurement range. Matrix effects were observed; however, the use of labeled internal standards matching the metabolites of interest minimized the impact on quantification. The extraction recovery efficiency was acceptable for the analytical validation. Ambient stability extended to 10 days, resulting in individual sample biases of up to 22%. A statistically significant increase in TRP, KYN, and QA was observed in drug-positive urine compared to illicit drug-negative urine (p < 0.01). Conclusion: We developed a rapid and sensitive LC-MS/MS method for quantifying tryptophan, kynurenine, kynurenic acid, and quinolinic acid in urine that can aid in future research elucidating the relationship between substance use disorders and tryptophan metabolism.


  • Open Access

    Urine methamphetamine-to-amphetamine ratio by LC-MS/MS to differentiate methamphetamine use from pharmaceutical impurity in patients prescribed amphetamine

    by Lindsey Contella, Phillip Kang, Clara E. Wolf, Victoria L. Thomas, Melissa Gildenberg, Marion L. Snyder, Stacy E.F. Melanson, Nicole V. Tolan

    Patients compliant with prescribed amphetamine (AMPH) should not have detectable methamphetamine (METH) in their urine; detectable METH typically indicates illicit use. However, we have identified patients with results suggestive of METH as an impurity in prescribed AMPH. Derive a METH:AMPH ratio cut-off from a training set of patients compliant with AMPH prescriptions to differentiate METH as an impurity from illicit use. Retrospective review of AMPH and METH-positive cases by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at Brigham and Women's Hospital (BWH) and Luxor Scientific. Correlated results with clinical and medication history and compliance with prescribed medications. The median ± interquartile range (IQR) METH:AMPH ratio for the Adderall training sets was 0.43 ± 0.31 % and 0.05 ± 0.040 %, with a maximum ratio of 1.125 % and 0.125 % at BWH and Luxor, respectively. The median ± IQR METH:AMPH ratio for the Luxor d-AMPH training set was 0.039 ± 0.028 %, with a maximum ratio of 0.09 %; not statistically different from the Adderall training set. Assessment of the BWH test set where METH < AMPH (n = 22) revealed that METH was likely due to an impurity (n = 10), distant METH mis/use (n = 11), or requiring further analysis (n = 1). METH was also detected by LC-MS/MS in a commercial AMPH calibrator and in Adderall XR. METH may represent an impurity in the AMPH formulation. Laboratories are encouraged to define a METH:AMPH ratio below which an impurity is the likely explanation for METH and/or to increase the METH positivity cut-off to 50 or 100 ng/mL to reduce potential false-accusations of illicit METH use.


  • Open Access

    Electronic tools to improve procalcitonin utilization

    by Julia A. Hisey, Grace K. Mahowald, Nicole V. Tolan, Phillip Kang, Ramy H. Elshaboury, Anand S. Dighe, Kent B. Lewandrowski, Christiana A. Demetriou, Stacy E.F. Melanson, Alyssa R. Letourneau


  • Clinical performance of a new lateral flow immunoassay for xylazine detection

    by Lindsey Contella, Marion L. Snyder, Phillip Kang, Nicole V. Tolan, Stacy E.F. Melanson

    Objectives: Xylazine is a potent sedative used in veterinary medicine. Recently, recreational drugs such as fentanyl have been found to contain xylazine, increasing the risk of respiratory depression and death. Despite a similar presentation to opioid overdose, patients who ingest xylazine do not respond to treatment with Narcan. Therefore, rapid detection of xylazine could improve patient management and prevent adverse outcomes. Methods: We evaluated the XYL500 one-step xylazine drug of abuse test for its ability to detect xylazine in 152 urine samples from patients on chronic opioid therapy for pain management or in treatment for substance use disorder. Results were compared to LC-MS/MS as the reference method. Precision, cross-reactivity, interference and stability studies were performed. Results: Pooled patient samples were consistently negative or positive when tested five times on the same day and over three days of testing. The diagnostic sensitivity, specificity and accuracy of the XYL500 assay were 74, 98, and 82 % respectively, as compared with LC-MS/MS. XYL500 detected 77 of the 104 LC-MS/MS positive samples identified in our initial evaluation, including some that contained low levels of xylazine (n=8), <10 ng/mL. Minimal cross-reactivity with other opioid analgesics and commonly encountered drugs was seen with only one false positive result. Interferences by common urine contaminants were negligible. Specimens were stable up to 160 days refrigerated and up to 80 days at room temperature. Conclusions: XYL500 allows for rapid detection of xylazine, illustrating its utility in monitoring patients who ingested recreational drugs containing the additive, xylazine, and its potential to improve patient management.


  • Open Access

    Despite the improved clinical sensitivity of the Roche benzodiazepines II assay it cannot replace mass spectrometry in all patient populations

    by Nicole V. Tolan, Sacha Uljon, M. Lauren Donnelly-Morell, Melissa Zhao, Grace K. Mahowald, Marion L. Snyder, Lindsey Contella, Elizabeth D. Urwiller, Maria Daluz Fernandes, Phillip Kang, et al.

    Benzodiazepines are frequently prescribed and misused therefore urine drug screening (UDS) is performed in many patient populations. Most current benzodiazepine immunoassays have poor sensitivity, particularly for detecting the metabolites of newer benzodiazepines such as lorazepam in urine. We aimed to verify the clinical performance of the new qualitative Roche Benzodiazepines II (BNZ2) immunoassay, as well as compare its performance to the Roche Benzodiazepines Plus (BENZ) assay in two patient populations: UDS in the emergency department (ED) and compliance monitoring. An initial verification study was performed, selecting for samples containing clonazepam and lorazepam metabolites. Performance of the BNZ2 and BENZ assays was compared to liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the reference method. Sensitivity, specificity, false positive rate (FPR) and false negative rate (FNR) were determined. We verified the performance claims in the initial verification and demonstrated similar precision, with coefficient of variations (CVs) of 12.8% and 7.7% for negative and positive controls, respectively. Furthermore, we observed higher clinical sensitivity and lower FNR with the BNZ2 assay in both the ED and compliance monitoring populations due to improved cross-reactivity for lorazepam and clonazepam metabolites. Despite these improvements, the BNZ2 assay was unable to detect 27% of specimens positive by LC-MS/MS, including specimens from patients using benzodiazepines without prescription. Due to its improved performance and rapid turnaround time, the BNZ2 assay should be implemented for UDS in the ED. However, the assay should not replace LC-MS/MS testing for compliance monitoring, as unsuspected benzodiazepine use may go undetected.


  • Commentary on Illegal Drug Use or Not—The Role of the Laboratory in Helping to Interpret Drug Test Results

    by Melissa M Zhao, Nicole V Tolan

    Interpretation of urine toxicology testing, including immunoassay screening and mass spectrometry-based confirmatory methods, is complicated. Carr et al. present a compelling case of an extremely knowledgeable patient (laboratorian and former College of American Pathologists inspector) who struggled to correct the misinterpretation of her own results. Following poppy seed ingestion, morphine concentrations are expected to exceed those of codeine, where only excessive poppy seed ingestion produces morphine concentrations up to 2000 ng/mL ( 1). This had led to the long-standing guidance that only codeine ingestion would produce urine codeine concentrations >300 ng/mL with morphine-to-codeine ratios 300 ng/mL and exceeding those of morphine, depending upon the species, growth conditions, and preparation methods of the poppy seeds ( 5). Considering this along with our own institutional experiences, our best practice recommendations are to first council patients to abstain from poppy seed-containing products prior to drug monitoring studies, perhaps including this in their treatment contract, and second, consider poppy seed ingestion as a possible etiology when samples screen positive for opiates and/or contain codeine concentrations exceeding those of morphine.

  • Cannabis positivity rates in 17 emergency departments across the United States with varying degrees of marijuana legalization

    by Nicole V. Tolan, Matthew D. Krasowski, Patrick C. Mathias, Joesph R. Wiencek, Nikolina Babic, Peter R. Chai, Allison B. Chambliss, Ibrahim Choucair, Christiana A. Demetriou, Timothy B. Erickson, et al.

    Many states in the United States have progressed towards legalization of marijuana including decriminalization, medicinal and/or recreational use. We studied the impact of legalization on cannabis-...


  • Lessons learned: A look back at the performance of nine COVID-19 serologic assays and their proposed utility

    by Nicole V. Tolan, Mia S DeSimone, Maria D Fernandes, Joshua E. Lewis, Daimon P Simmons, Peter H Schur, Manfred Brigl, Milenko J Tanasijevic, Michaël Desjardins, Amy C Sherman, et al.


  • Correctly Establishing and Interpreting Oxygenation Status in Sickle Cell Disease

    by Fabienne Lucas, Nathan T Connell, Nicole V Tolan

    As hypoxemia and hypoxia are central elements of disease pathophysiology and disease-related morbidity and mortality in individuals affected by sickle cell disease (SCD), clinical management aims to optimize oxygenation. Hypoxemia is primarily screened for with pulse oximetry. However, in SCD pulse oximetry can inaccurately reflect arterial saturation, posing the risk of undetected (occult) hypoxemia. Solely relying on pulse oximetry might therefore lead to misdiagnosis or mismanagement, with devastating effects on tissue oxygenation. The interpretation of oxygenation status is multifaceted, and “oxygen saturation” is often used as an umbrella term to refer to distinctly different measured quantities—estimated oxygen saturation (O2Sat), hemoglobin oxygen saturation (SO2) by either pulse oximetry or co-oximetry, and fractional oxyhemoglobin (FO2Hb). While in many clinical situations this ambiguous use is of little consequence, O2Sat, SO2, and FO2Hb cannot be used interchangeably in the setting of SCD, as dyshemoglobins, anemia, cardiopulmonary comorbidities, concomitant medications, and frequent transfusions need to be accounted for. This article describes the parameters that determine blood and tissue oxygen concentration, discusses laboratory method performance characteristics and the correct interpretation of currently available clinical laboratory testing, and reviews the literature on noninvasive vs invasive oxygenation measurements in SCD. By correctly establishing and interpreting oxygenation parameters, clinical and laboratory teams can ensure high-quality, equitable healthcare, counteracting systemic exacerbations of health disparities frequently experienced by individuals with SCD.