Sandeep Ghai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sandeep Ghai has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Frederick Au
Joint Department of Medical Imaging, Toronto General Hospital, Toronto, Ontario, Canada
4 shared publications - Supriya Kulkarni
University of Toronto, Princess Margaret Hospital
4 shared publications - Vivianne Freitas
Joint Department of Medical Imaging, University of Toronto, 610 University Ave, Toronto, ON, Canada M5G 2M9
4 shared publications Karina Bukhanov
2 shared publicationsXuan Li
2 shared publications- Abdullah Alabousi
McMaster University, St. Joseph’s Healthcare Hamilton
1 shared publication
Latest Publications
- 1 March 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 6 (2) , e230020
Breast Cancer Detection Using a Low-Dose Positron Emission Digital Mammography System
Purpose To investigate the feasibility of low-dose positron emission mammography (PEM) concurrently to MRI to identify breast cancer and determine its local extent. Materials and Methods In this research ethics board-approved prospective study, participants newly diagnosed with breast cancer with concurrent breast MRI acquisitions were assigned independently of breast density, tumor size, and histopathologic cancer subtype to undergo low-dose PEM with up to 185 MBq of fluorine 18-labeled fluorodeoxyglucose (18F-FDG). Two breast radiologists, unaware of the cancer location, reviewed PEM images taken 1 and 4 hours following 18F-FDG injection. Findings were correlated with histopathologic results. Detection accuracy and participant details were examined using logistic regression and summary statistics, and a comparative analysis assessed the efficacy of PEM and MRI additional lesions detection (ClinicalTrials.gov: NCT03520218). Results Twenty-five female participants (median age, 52 years; range, 32-85 years) comprised the cohort. Twenty-four of 25 (96%) cancers (19 invasive cancers and five in situ diseases) were identified with PEM from 100 sets of bilateral images, showcasing comparable performance even after 3 hours of radiotracer uptake. The median invasive cancer size was 31 mm (range, 10-120). Three additional in situ grade 2 lesions were missed at PEM. While not significant, PEM detected fewer false-positive additional lesions compared with MRI (one of six [16%] vs eight of 13 [62%]; P = .14). Conclusion This study suggests the feasibility of a low-dose PEM system in helping to detect invasive breast cancer. Though large-scale clinical trials are essential to confirm these preliminary results, this study underscores the potential of this low-dose PEM system as a promising imaging tool in breast cancer diagnosis. ClinicalTrials.gov registration no. NCT03520218 Keywords: Positron Emission Digital Mammography, Invasive Breast Cancer, Oncology, MRI Supplemental material is available for this article. © RSNA, 2024 See also commentary by Barreto and Rapelyea in this issue.
- 1 March 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 6 (2) , e230020
Breast Cancer Detection Using a Low-Dose Positron Emission Digital Mammography System
Purpose To investigate the feasibility of low-dose positron emission mammography (PEM) concurrently to MRI to identify breast cancer and determine its local extent. Materials and Methods In this research ethics board-approved prospective study, participants newly diagnosed with breast cancer with concurrent breast MRI acquisitions were assigned independently of breast density, tumor size, and histopathologic cancer subtype to undergo low-dose PEM with up to 185 MBq of fluorine 18-labeled fluorodeoxyglucose (18F-FDG). Two breast radiologists, unaware of the cancer location, reviewed PEM images taken 1 and 4 hours following 18F-FDG injection. Findings were correlated with histopathologic results. Detection accuracy and participant details were examined using logistic regression and summary statistics, and a comparative analysis assessed the efficacy of PEM and MRI additional lesions detection (ClinicalTrials.gov: NCT03520218). Results Twenty-five female participants (median age, 52 years; range, 32-85 years) comprised the cohort. Twenty-four of 25 (96%) cancers (19 invasive cancers and five in situ diseases) were identified with PEM from 100 sets of bilateral images, showcasing comparable performance even after 3 hours of radiotracer uptake. The median invasive cancer size was 31 mm (range, 10-120). Three additional in situ grade 2 lesions were missed at PEM. While not significant, PEM detected fewer false-positive additional lesions compared with MRI (one of six [16%] vs eight of 13 [62%]; P = .14). Conclusion This study suggests the feasibility of a low-dose PEM system in helping to detect invasive breast cancer. Though large-scale clinical trials are essential to confirm these preliminary results, this study underscores the potential of this low-dose PEM system as a promising imaging tool in breast cancer diagnosis. ClinicalTrials.gov registration no. NCT03520218 Keywords: Positron Emission Digital Mammography, Invasive Breast Cancer, Oncology, MRI Supplemental material is available for this article. © RSNA, 2024 See also commentary by Barreto and Rapelyea in this issue.
- Top Cited Papers
- 1 March 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e221785
Supplemental Breast Cancer Screening in Women with Dense Breasts and Negative Mammography: A Systematic Review and Meta-Analysis
Background The best supplemental breast cancer screening modality in women at average risk or intermediate risk for breast cancer with dense breast and negative mammogram remains to be determined. Purpose To conduct systematic review and meta-analysis comparing clinical outcomes of the most common available supplemental screening modalities in women at average risk or intermediate risk for breast cancer in patients with dense breasts and mammography with negative findings. Materials and Methods A comprehensive search was conducted until March 12, 2020, in Medline, Epub Ahead of Print and In-Process and Other Non-Indexed Citations; Embase Classic and Embase; Cochrane Central Register of Controlled Trials; and Cochrane Database of Systematic Reviews, for Randomized Controlled Trials and Prospective Observational Studies. Incremental cancer detection rate (CDR); positive predictive value of recall (PPV1); positive predictive value of biopsies performed (PPV3); and interval CDRs of supplemental imaging modalities, digital breast tomosynthesis, handheld US, automated breast US, and MRI in non-high-risk patients with dense breasts and mammography negative for cancer were reviewed. Data metrics and risk of bias were assessed. Random-effects meta-analysis and two-sided metaregression analyses comparing each imaging modality metrics were performed (PROSPERO; CRD42018080402). Results Twenty-two studies reporting 261 233 screened patients were included. Of 132 166 screened patients with dense breast and mammography negative for cancer who met inclusion criteria, a total of 541 cancers missed at mammography were detected with these supplemental modalities. Metaregression models showed that MRI was superior to other supplemental modalities in CDR (incremental CDR, 1.52 per 1000 screenings; 95% CI: 0.74, 2.33; P < .001), including invasive CDR (invasive CDR, 1.31 per 1000 screenings; 95% CI: 0.57, 2.06; P < .001), and in situ disease (rate of ductal carcinoma in situ, 1.91 per 1000 screenings; 95% CI: 0.10, 3.72; P < .04). No differences in PPV1 and PPV3 were identified. The limited number of studies prevented assessment of interval cancer metrics. Excluding MRI, no statistically significant difference in any metrics were identified among the remaining imaging modalities. Conclusion The pooled data showed that MRI was the best supplemental imaging modality in women at average risk or intermediate risk for breast cancer with dense breasts and mammography negative for cancer. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Hooley and Butler in this issue.
- 1 March 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e221785
Top Cited PapersSupplemental Breast Cancer Screening in Women with Dense Breasts and Negative Mammography: A Systematic Review and Meta-Analysis
Background The best supplemental breast cancer screening modality in women at average risk or intermediate risk for breast cancer with dense breast and negative mammogram remains to be determined. Purpose To conduct systematic review and meta-analysis comparing clinical outcomes of the most common available supplemental screening modalities in women at average risk or intermediate risk for breast cancer in patients with dense breasts and mammography with negative findings. Materials and Methods A comprehensive search was conducted until March 12, 2020, in Medline, Epub Ahead of Print and In-Process and Other Non-Indexed Citations; Embase Classic and Embase; Cochrane Central Register of Controlled Trials; and Cochrane Database of Systematic Reviews, for Randomized Controlled Trials and Prospective Observational Studies. Incremental cancer detection rate (CDR); positive predictive value of recall (PPV1); positive predictive value of biopsies performed (PPV3); and interval CDRs of supplemental imaging modalities, digital breast tomosynthesis, handheld US, automated breast US, and MRI in non-high-risk patients with dense breasts and mammography negative for cancer were reviewed. Data metrics and risk of bias were assessed. Random-effects meta-analysis and two-sided metaregression analyses comparing each imaging modality metrics were performed (PROSPERO; CRD42018080402). Results Twenty-two studies reporting 261 233 screened patients were included. Of 132 166 screened patients with dense breast and mammography negative for cancer who met inclusion criteria, a total of 541 cancers missed at mammography were detected with these supplemental modalities. Metaregression models showed that MRI was superior to other supplemental modalities in CDR (incremental CDR, 1.52 per 1000 screenings; 95% CI: 0.74, 2.33; P < .001), including invasive CDR (invasive CDR, 1.31 per 1000 screenings; 95% CI: 0.57, 2.06; P < .001), and in situ disease (rate of ductal carcinoma in situ, 1.91 per 1000 screenings; 95% CI: 0.10, 3.72; P < .04). No differences in PPV1 and PPV3 were identified. The limited number of studies prevented assessment of interval cancer metrics. Excluding MRI, no statistically significant difference in any metrics were identified among the remaining imaging modalities. Conclusion The pooled data showed that MRI was the best supplemental imaging modality in women at average risk or intermediate risk for breast cancer with dense breasts and mammography negative for cancer. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Hooley and Butler in this issue.
- 1 August 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (2) , 297-307
Contralateral Breast Screening with Preoperative MRI: Long-Term Outcomes for Newly Diagnosed Breast Cancer
In patients with newly diagnosed breast cancer, preoperative breast MRI depicted contralateral synchronous disease and was associated with improved overall survival. Background The diagnostic value of screening the contralateral breast with MRI in patients with newly diagnosed breast cancer is poorly understood. Purpose To assess the impact of MRI for screening...
- 1 August 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 304 (2) , 297-307
Contralateral Breast Screening with Preoperative MRI: Long-Term Outcomes for Newly Diagnosed Breast Cancer
In patients with newly diagnosed breast cancer, preoperative breast MRI depicted contralateral synchronous disease and was associated with improved overall survival. Background The diagnostic value of screening the contralateral breast with MRI in patients with newly diagnosed breast cancer is poorly understood. Purpose To assess the impact of MRI for screening...
- Open Access
- 28 December 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 17 (3) , 775-778
COVID-19 vaccine-related axillary edema in breast imaging setting
- 28 December 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 17 (3) , 775-778
Open AccessCOVID-19 vaccine-related axillary edema in breast imaging setting
- Open Access
- 3 November 2015
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 8 (6) , 722-728
Proliferative glomerulonephritis with monoclonal immunoglobulin in renal allografts
Glomerulopathy due to dysproteinemia can have a wide spectrum of pathologic and clinical features based on specific characteristics of the abnormal protein and the response induced within the parenchymal tissue. Monoclonal immunoglobulin G (IgG) deposition can manifest as a different glomerular disease. Proliferative glomerulonephritis (GN) with monoclonal IgG deposits (PGNMID) is a unique entity mimicking immune complex GN that does not conform to any of those subtypes. IgG monoclonal granular deposition in the glomeruli with a pattern similar to immune complex disease suggested by C3 and C1q deposition should prompt consideration of PGNMID. Literature is scarce in terms of recurrence of disease in renal allografts. In this article we present the clinical–pathologic features of three cases of PGNMID in the renal allograft showing the variable course and manifestation of the disease.
- 3 November 2015
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 8 (6) , 722-728
Open AccessProliferative glomerulonephritis with monoclonal immunoglobulin in renal allografts
Glomerulopathy due to dysproteinemia can have a wide spectrum of pathologic and clinical features based on specific characteristics of the abnormal protein and the response induced within the parenchymal tissue. Monoclonal immunoglobulin G (IgG) deposition can manifest as a different glomerular disease. Proliferative glomerulonephritis (GN) with monoclonal IgG deposits (PGNMID) is a unique entity mimicking immune complex GN that does not conform to any of those subtypes. IgG monoclonal granular deposition in the glomeruli with a pattern similar to immune complex disease suggested by C3 and C1q deposition should prompt consideration of PGNMID. Literature is scarce in terms of recurrence of disease in renal allografts. In this article we present the clinical–pathologic features of three cases of PGNMID in the renal allograft showing the variable course and manifestation of the disease.