Lina Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lina Zhang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alexandria Brackett
Harvey Cushing/John Hay Whitney Medical Library, Yale University, New Haven, CT, United States
1 shared publication - Dapeng Liu
Department of Orthopedics, The Fifth Affiliated Hospital, Xinjiang Medical University, Urumqi, Xinjiang, China
1 shared publication - Feng Dai
Pfizer Inc, New York, USA
1 shared publication Fuhao Mo
College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan, China
1 shared publication- Jing Yang
Department of Orthopedics, The Fifth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830011, China
1 shared publication - Junmei Xu
Department of Anesthesiology, the Second XiangYa Hospital, Central South University
1 shared publication
Latest Publications
- 28 December 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (6) , 760-768
Clinical Application of a 3D-Printed Positioning Module and Navigation Template for Percutaneous Vertebroplasty
Background: This study aimed to evaluate a personalized 3D-printed percutaneous vertebroplasty positioning module and navigation template based on preoperative CT scan data that was designed to treat patients with vertebral compression fractures caused by osteoporosis. Methods: A total of 22 patients with vertebral compression fractures admitted to our hospital were included in the study. Positioning was performed with the new 3D-printed positioning module, and the navigation template was used for patients in the experimental group, and the traditional perspective method was used for patients in the control group. The experimental group consisted of 11 patients, 2 males and 9 females, with a mean age of 67.27 ± 11.86 years (range: 48 to 80 years), and the control group consisted of 11 patients, 3 males and 8 females, with a mean age of 74.27 ± 7.24 years (range: 63 to 89 years). The puncture positioning duration, number of intraoperative fluoroscopy sessions, and preoperative and postoperative visual analog scale (VAS) scores were statistically analyzed in both groups. Results: The experimental group had shorter puncture positioning durations and fewer intraoperative fluoroscopy sessions than the control group, and the differences were statistically significant (P < .05). There were no significant differences in age or preoperative or postoperative VAS scores between the two groups (P > .05). Conclusions: The new 3D-printed vertebroplasty positioning module and navigation template shortened the operation time and reduced the number of intraoperative fluoroscopy sessions. It also reduced the difficulty in performing percutaneous vertebroplasty and influenced the learning curve of senior doctors learning this operation to a certain degree.
- 28 December 2021
- Published by SAGE Publications in Surgical Innovation
- Vol. 29 (6) , 760-768
Clinical Application of a 3D-Printed Positioning Module and Navigation Template for Percutaneous Vertebroplasty
Background: This study aimed to evaluate a personalized 3D-printed percutaneous vertebroplasty positioning module and navigation template based on preoperative CT scan data that was designed to treat patients with vertebral compression fractures caused by osteoporosis. Methods: A total of 22 patients with vertebral compression fractures admitted to our hospital were included in the study. Positioning was performed with the new 3D-printed positioning module, and the navigation template was used for patients in the experimental group, and the traditional perspective method was used for patients in the control group. The experimental group consisted of 11 patients, 2 males and 9 females, with a mean age of 67.27 ± 11.86 years (range: 48 to 80 years), and the control group consisted of 11 patients, 3 males and 8 females, with a mean age of 74.27 ± 7.24 years (range: 63 to 89 years). The puncture positioning duration, number of intraoperative fluoroscopy sessions, and preoperative and postoperative visual analog scale (VAS) scores were statistically analyzed in both groups. Results: The experimental group had shorter puncture positioning durations and fewer intraoperative fluoroscopy sessions than the control group, and the differences were statistically significant (P < .05). There were no significant differences in age or preoperative or postoperative VAS scores between the two groups (P > .05). Conclusions: The new 3D-printed vertebroplasty positioning module and navigation template shortened the operation time and reduced the number of intraoperative fluoroscopy sessions. It also reduced the difficulty in performing percutaneous vertebroplasty and influenced the learning curve of senior doctors learning this operation to a certain degree.
- Open Access
- 18 December 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (51) , e23764
Can bioimpedance cardiography assess hemodynamic response to passive leg raising in critically ill patients
Passive leg raising (PLR) is a convenient and reliable test to predict fluid responsiveness. The ability of thoracic electrical bioimpedance cardiography (TEB) to monitor changes of cardiac output (CO) during PLR is unknown. In the present study, we measured CO in 61 patients with shock or dyspnea by TEB and transthoracic echocardiography (TTE) during PLR procedure. Positive PLR responsiveness was defined as the velocity-time integral (VTI) ≥10% after PLR. TTE measured VTI in the left ventricular output tract. The predictive value of TEB parameters in PLR responders was tested. Furthermore, the agreement of absolute CO values between TEB and TTE measurements was assessed. Among the 61 patients, there were 28 PLR-responders and 33 non-responders. Twenty-seven patients were diagnosed with shock and 34 patients with dyspnea, with 55.6% (15/27) and 54.6% (18/34) non-responders, respectively. A change in TEB measured CO (ΔCO) ≥9.8% predicted PLR responders with 75.0% sensitivity and 78.8% specificity, the area under the receiver operating characteristic curve (AUROC) was 0.79. The Δd2 Z/dt 2 (a secondary derivative of the impedance wave) showed the best predictive value with AUROC of 0.90, the optimal cut point was −7.1% with 85.7% sensitivity and 87.9% specificity. Bias between TEB and TTE measured CO was 0.12 L/min, and the percentage error was 65.8%. TEB parameters had promising performance in predicting PLR responders, and the Δd2 Z/dt 2 had the best predictive value. The CO values measured by TEB were not interchangeable with TTE in critically ill settings.
- 18 December 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (51) , e23764
Open AccessCan bioimpedance cardiography assess hemodynamic response to passive leg raising in critically ill patients
Passive leg raising (PLR) is a convenient and reliable test to predict fluid responsiveness. The ability of thoracic electrical bioimpedance cardiography (TEB) to monitor changes of cardiac output (CO) during PLR is unknown. In the present study, we measured CO in 61 patients with shock or dyspnea by TEB and transthoracic echocardiography (TTE) during PLR procedure. Positive PLR responsiveness was defined as the velocity-time integral (VTI) ≥10% after PLR. TTE measured VTI in the left ventricular output tract. The predictive value of TEB parameters in PLR responders was tested. Furthermore, the agreement of absolute CO values between TEB and TTE measurements was assessed. Among the 61 patients, there were 28 PLR-responders and 33 non-responders. Twenty-seven patients were diagnosed with shock and 34 patients with dyspnea, with 55.6% (15/27) and 54.6% (18/34) non-responders, respectively. A change in TEB measured CO (ΔCO) ≥9.8% predicted PLR responders with 75.0% sensitivity and 78.8% specificity, the area under the receiver operating characteristic curve (AUROC) was 0.79. The Δd2 Z/dt 2 (a secondary derivative of the impedance wave) showed the best predictive value with AUROC of 0.90, the optimal cut point was −7.1% with 85.7% sensitivity and 87.9% specificity. Bias between TEB and TTE measured CO was 0.12 L/min, and the percentage error was 65.8%. TEB parameters had promising performance in predicting PLR responders, and the Δd2 Z/dt 2 had the best predictive value. The CO values measured by TEB were not interchangeable with TTE in critically ill settings.
- 1 December 2020
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 67, 110021
Hemodynamic management and surgical site infection: Network meta-analysis of randomized controlled trials
- 1 December 2020
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 67, 110021
Hemodynamic management and surgical site infection: Network meta-analysis of randomized controlled trials