Kazuma Date
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazuma Date has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Minoru Ono
Department of Cardiothoracic Surgery, The University of Tokyo, Tokyo, Japan
4 shared publicationsEisuke Tatsumi
Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
3 shared publicationsTomonori Tsukiya
Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
3 shared publicationsToshihide Mizuno
Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
3 shared publicationsYoshiaki Takewa
Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
3 shared publicationsAkihide Umeki
Department of Cardiothoracic Surgery, The University of Tokyo, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 29 December 2021
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (1) , 163-165
Perforation of the right atrial appendage during implantation of a leadless pacemaker
We report a case of perforation of the right atrial appendage during implantation of a leadless pacemaker in a 94 years old woman. We performed emergency surgery to repair the perforation site. To our konwledge, there are few reports of right atrial perforation during a leadless pacemaker indwelling.
- 29 December 2021
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (1) , 163-165
Open AccessPerforation of the right atrial appendage during implantation of a leadless pacemaker
We report a case of perforation of the right atrial appendage during implantation of a leadless pacemaker in a 94 years old woman. We performed emergency surgery to repair the perforation site. To our konwledge, there are few reports of right atrial perforation during a leadless pacemaker indwelling.
- 19 July 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (1) , 18-25
Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART®; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to P/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
- 19 July 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (1) , 18-25
Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART®; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to P/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
- 14 May 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (4) , 315-321
Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system
- 14 May 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (4) , 315-321
Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system
- 27 January 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (3) , 301-304
Effects of feeding state on anticoagulation in adult goats treated with warfarin
For the continued development of improved mechanical circulatory systems, longer term evaluation of new devices in animal model experiments may be critical. The effects of anticoagulants in adult goats have not been well studied. We assessed the effects of oral warfarin in three adult goats during fasting or after feeding. The goats [weighing 57.8 ± 8.1 kg (53.0–67.2 kg)] were administered warfarin orally beginning at a dose of 5 mg/day and then increasing to 10, 20, 40, and 60 mg every 2 weeks. One goat (receiving 10 mg/day warfarin) was killed on day 27 because of the inability to stand. After administration of 60 mg warfarin, the remaining goat received no warfarin for 4 days to return to coagulated state. The goats were then fasted and treated with 40 mg warfarin. During warfarin administration, both goats required a dose of 60 mg/day to achieve International Normalized Ratios (INRs) of approximately 2.5; however, when, the animals were in the fasted condition, precipitous extension of INR was observed in 5 days. After resuming feeding, the INR was reduced to the proper range. We showed the tendency that warfarin therapy in goats required higher doses than the doses administered to human patients and that the effects of therapy were related to the feeding state. The results of this study provide important information for development of anticoagulation protocols to assess mechanical circulatory support devices for long-term use in preclinical examination.
- 27 January 2016
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 19 (3) , 301-304
Effects of feeding state on anticoagulation in adult goats treated with warfarin
For the continued development of improved mechanical circulatory systems, longer term evaluation of new devices in animal model experiments may be critical. The effects of anticoagulants in adult goats have not been well studied. We assessed the effects of oral warfarin in three adult goats during fasting or after feeding. The goats [weighing 57.8 ± 8.1 kg (53.0–67.2 kg)] were administered warfarin orally beginning at a dose of 5 mg/day and then increasing to 10, 20, 40, and 60 mg every 2 weeks. One goat (receiving 10 mg/day warfarin) was killed on day 27 because of the inability to stand. After administration of 60 mg warfarin, the remaining goat received no warfarin for 4 days to return to coagulated state. The goats were then fasted and treated with 40 mg warfarin. During warfarin administration, both goats required a dose of 60 mg/day to achieve International Normalized Ratios (INRs) of approximately 2.5; however, when, the animals were in the fasted condition, precipitous extension of INR was observed in 5 days. After resuming feeding, the INR was reduced to the proper range. We showed the tendency that warfarin therapy in goats required higher doses than the doses administered to human patients and that the effects of therapy were related to the feeding state. The results of this study provide important information for development of anticoagulation protocols to assess mechanical circulatory support devices for long-term use in preclinical examination.
- 1 May 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 97 (5) , 1778-1781
Thoracoabdominal Aortic Aneurysm Repair in a Patient With a Left Ventricular Assist Device
- 1 May 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 97 (5) , 1778-1781
Thoracoabdominal Aortic Aneurysm Repair in a Patient With a Left Ventricular Assist Device
- 15 February 2014
- Published by Springer Nature in Heart and Vessels
- Vol. 30 (3) , 420-425
Aortoiliac aneurysm with congenital right pelvic kidney
The association of congenital pelvic kidney with abdominal aortoiliac aneurysm is an extremely rare clinical finding. Previous reports have described various methods of aneurysm repair with successful preservation of the function of pelvic kidney. However, to our knowledge, reconstruction of more than two renal arteries has not been established. We report a case of abdominal aortic aneurysm complicated by congenital right pelvic kidney in a 72-year-old man. Computed tomography (CT) revealed an abdominal aortic aneurysm with a maximum diameter of 54 mm and a right common iliac aneurysm of 45 mm. In addition, he had a congenital right pelvic kidney and CT angiography identified three right pelvic renal arteries. The upper artery originated from the bifurcation of the terminal aorta and the lower two originated from the right common iliac artery. Three-dimensional CT was helpful for the accurate planning of the operation. Open surgical repair of the aortoiliac aneurysm with a Dacron bifurcated graft replacement was decided and reimplantation of all three right pelvic kidney arteries to the right limb of the graft was also performed. For renal preservation, the right pelvic kidney arteries were perfused with cold Ringer’s lactate using a rapid infusion pump and coronary perfusion cannula. The patient’s postoperative course was uneventful, and worsening of renal function was not observed. The perfusion of renal arteries with cold Ringer’s solution was thought to be a simple and appropriate procedure for renal protection.
- 15 February 2014
- Published by Springer Nature in Heart and Vessels
- Vol. 30 (3) , 420-425
Aortoiliac aneurysm with congenital right pelvic kidney
The association of congenital pelvic kidney with abdominal aortoiliac aneurysm is an extremely rare clinical finding. Previous reports have described various methods of aneurysm repair with successful preservation of the function of pelvic kidney. However, to our knowledge, reconstruction of more than two renal arteries has not been established. We report a case of abdominal aortic aneurysm complicated by congenital right pelvic kidney in a 72-year-old man. Computed tomography (CT) revealed an abdominal aortic aneurysm with a maximum diameter of 54 mm and a right common iliac aneurysm of 45 mm. In addition, he had a congenital right pelvic kidney and CT angiography identified three right pelvic renal arteries. The upper artery originated from the bifurcation of the terminal aorta and the lower two originated from the right common iliac artery. Three-dimensional CT was helpful for the accurate planning of the operation. Open surgical repair of the aortoiliac aneurysm with a Dacron bifurcated graft replacement was decided and reimplantation of all three right pelvic kidney arteries to the right limb of the graft was also performed. For renal preservation, the right pelvic kidney arteries were perfused with cold Ringer’s lactate using a rapid infusion pump and coronary perfusion cannula. The patient’s postoperative course was uneventful, and worsening of renal function was not observed. The perfusion of renal arteries with cold Ringer’s solution was thought to be a simple and appropriate procedure for renal protection.