Ji Won Bak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ji Won Bak has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Minsoo Kim
Department of Anesthesiology, Kangwon National University School of Medicine, Chuncheon 24341, Kangwon-do, Republic of Korea
2 shared publications - Byeongmun Hwang
Department of Anesthesiology and Pain Medicine, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Korea
1 shared publication - Chan-Sik Kim
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea
1 shared publication - Giyong Yoon1 shared publication
- Hee Jeong Son
Department of Anesthesiology and Pain Medicine, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Korea
1 shared publication - Jihion Yu
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 8 September 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (10) , 3984-3989
Unilateral vocal cord paralysis following arthroscopic rotator cuff repair in the beach chair position: a case series
Introduction: Vocal cord paralysis (VCP) is a rare complication of endotracheal intubation. During shoulder surgery in the beach chair position, deliberate hypotension may compromise perfusion of laryngeal structures. This case series was conducted to describe the clinical characteristics of postoperative VCP in this setting and to explore the potential role of intraoperative hypotension as an underlying mechanism. Case presentations: This retrospective single-center case series included four consecutive female patients with hypertension who developed unilateral (left-sided) VCP after arthroscopic rotator cuff repair in the beach chair position under general anesthesia. Intraoperatively, mean blood pressure was maintained at low levels, with periods below 60 mmHg in all cases. Postoperatively, patients presented with hoarseness and aspiration. Laryngoscopic examination confirmed left-sided VCP in all cases, and laryngeal electromyography demonstrated recurrent laryngeal nerve neuropathy in two cases. All patients improved with conservative management, and no statistical analysis was performed given the descriptive nature of this case series. Discussion: Direct airway trauma, endotracheal tube malposition, and cuff overinflation were unlikely causes. Instead, reduced perfusion pressure related to head elevation and intraoperative hypotension may have contributed to ischemic injury of the recurrent laryngeal nerve. These findings suggest that postoperative VCP may involve factors beyond traditional mechanical airway-related mechanisms and warrant further investigation of perioperative hemodynamic influences. Conclusion: Shoulder surgery in the beach chair position combined with intraoperative hypotension may predispose patients to postoperative VCP. This case series extends previous observations by highlighting a potential association between intraoperative hemodynamic management and postoperative recurrent laryngeal nerve dysfunction. These findings underscore the potential importance of individualized intraoperative blood pressure management in reducing the risk of this complication. Further prospective studies are warranted to clarify the relationship between head elevation, regional perfusion, and laryngeal nerve injury during shoulder surgery.
- 8 September 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (10) , 3984-3989
Open AccessUnilateral vocal cord paralysis following arthroscopic rotator cuff repair in the beach chair position: a case series
Introduction: Vocal cord paralysis (VCP) is a rare complication of endotracheal intubation. During shoulder surgery in the beach chair position, deliberate hypotension may compromise perfusion of laryngeal structures. This case series was conducted to describe the clinical characteristics of postoperative VCP in this setting and to explore the potential role of intraoperative hypotension as an underlying mechanism. Case presentations: This retrospective single-center case series included four consecutive female patients with hypertension who developed unilateral (left-sided) VCP after arthroscopic rotator cuff repair in the beach chair position under general anesthesia. Intraoperatively, mean blood pressure was maintained at low levels, with periods below 60 mmHg in all cases. Postoperatively, patients presented with hoarseness and aspiration. Laryngoscopic examination confirmed left-sided VCP in all cases, and laryngeal electromyography demonstrated recurrent laryngeal nerve neuropathy in two cases. All patients improved with conservative management, and no statistical analysis was performed given the descriptive nature of this case series. Discussion: Direct airway trauma, endotracheal tube malposition, and cuff overinflation were unlikely causes. Instead, reduced perfusion pressure related to head elevation and intraoperative hypotension may have contributed to ischemic injury of the recurrent laryngeal nerve. These findings suggest that postoperative VCP may involve factors beyond traditional mechanical airway-related mechanisms and warrant further investigation of perioperative hemodynamic influences. Conclusion: Shoulder surgery in the beach chair position combined with intraoperative hypotension may predispose patients to postoperative VCP. This case series extends previous observations by highlighting a potential association between intraoperative hemodynamic management and postoperative recurrent laryngeal nerve dysfunction. These findings underscore the potential importance of individualized intraoperative blood pressure management in reducing the risk of this complication. Further prospective studies are warranted to clarify the relationship between head elevation, regional perfusion, and laryngeal nerve injury during shoulder surgery.
- 1 March 2023
- Published by Wiley in Anaesthesia
- Vol. 78 (6) , 730-738
Effect of pneumatic leg compression on post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy: a double‐blind randomised controlled trial
Summary: Post‐induction hypotension is common and associated with postoperative complications. We hypothesised that pneumatic leg compression reduces post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy. In this double‐blind randomised study, patients were allocated randomly to the pneumatic leg compression group (n = 50) or control (n = 50). In the intervention group, pneumatic leg compression was initiated before induction of anaesthesia. In the control group, pneumatic leg compression was initiated 20 min after anaesthesia induction. The primary outcome was the incidence of post‐induction hypotension in these groups. Post‐induction hypotension was defined as systolic blood pressure < 90 mmHg during the first 20 min after induction. Haemodynamic variables and area under the curve of post‐induction systolic blood pressure over time were assessed. Complications associated with pneumatic leg compression were recorded, including: peripheral neuropathy; compartment syndrome; extensive bullae beneath the leg sleeves; and pulmonary thromboembolism. The incidence of post‐induction hypotension decreased in the pneumatic leg compression group compared with that in the control group; 5 (10%) vs. 29 (58%), respectively, p < 0.001. In the pneumatic leg compression group, the lowest systolic, diastolic and mean blood pressures 20 min after induction of anaesthesia were significantly greater than the control group. Pneumatic leg compression resulted in an increased area under the curve of systolic blood pressure in the first 20 min after induction, p = 0.001. There were no pneumatic leg compression‐related complications. Pneumatic leg compression reduced post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy, suggesting that it is an effective and safe intervention to prevent post‐induction hypotension among elderly patients undergoing general anaesthesia.
- 1 March 2023
- Published by Wiley in Anaesthesia
- Vol. 78 (6) , 730-738
Effect of pneumatic leg compression on post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy: a double‐blind randomised controlled trial
Summary: Post‐induction hypotension is common and associated with postoperative complications. We hypothesised that pneumatic leg compression reduces post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy. In this double‐blind randomised study, patients were allocated randomly to the pneumatic leg compression group (n = 50) or control (n = 50). In the intervention group, pneumatic leg compression was initiated before induction of anaesthesia. In the control group, pneumatic leg compression was initiated 20 min after anaesthesia induction. The primary outcome was the incidence of post‐induction hypotension in these groups. Post‐induction hypotension was defined as systolic blood pressure < 90 mmHg during the first 20 min after induction. Haemodynamic variables and area under the curve of post‐induction systolic blood pressure over time were assessed. Complications associated with pneumatic leg compression were recorded, including: peripheral neuropathy; compartment syndrome; extensive bullae beneath the leg sleeves; and pulmonary thromboembolism. The incidence of post‐induction hypotension decreased in the pneumatic leg compression group compared with that in the control group; 5 (10%) vs. 29 (58%), respectively, p < 0.001. In the pneumatic leg compression group, the lowest systolic, diastolic and mean blood pressures 20 min after induction of anaesthesia were significantly greater than the control group. Pneumatic leg compression resulted in an increased area under the curve of systolic blood pressure in the first 20 min after induction, p = 0.001. There were no pneumatic leg compression‐related complications. Pneumatic leg compression reduced post‐induction hypotension in elderly patients undergoing robot‐assisted laparoscopic prostatectomy, suggesting that it is an effective and safe intervention to prevent post‐induction hypotension among elderly patients undergoing general anaesthesia.
- Open Access
- 31 January 2022
- Published by The Korean Society of Anesthesiologists in Anesthesia and Pain Medicine
- Vol. 17 (1) , 104-111
Comparison between GlideRite® rigid stylet and Parker Flex-It™ stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study
Background: The GlideScope® videolaryngoscope (GVL) is widely used in patients with difficult airways and provides a good glottic view. However, the acute angle of the blade can make insertion and advancement of an endotracheal tube (ETT) more difficult than direct laryngoscopy, and the use of a stylet is recommended. This randomized controlled trial compared Parker Flex-It™ stylet (PFS) with GlideRite® rigid stylet (GRS) to facilitate intubation with the GVL in simulated difficult intubations. Methods: Fifty-four patients were randomly allocated to undergo GVL intubation using either GRS (GRS group) or PFS (PFS group). The total intubation time (TIT), 100-mm visual analog scale (VAS) for ease of intubation, success rate at the first attempt, use of laryngeal manipulation, tube advancement rate by assistant, and complications were recorded. Results: There was no significant difference between the GRS and PFS groups regarding TIT (50.3 ± 12.0 s in the GRS group and 57.8 ± 18.8 s in the PFS group, P = 0.108). However, intubation was more difficult in the PFS group than in the GRS group according to VAS score (P = 0.011). Cases in which the ETT was advanced from the stylet by an assistant, were more frequent in the GRS group than in the PFS group (P = 0.002). The overall incidence of possible complications was not significantly different. Conclusions: In patients with a simulated difficult airway, there was no difference in TIT using either the PFS or GRS. However, endotracheal intubation with PFS is more difficult to perform than GRS.
- 31 January 2022
- Published by The Korean Society of Anesthesiologists in Anesthesia and Pain Medicine
- Vol. 17 (1) , 104-111
Open AccessComparison between GlideRite® rigid stylet and Parker Flex-It™ stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study
Background: The GlideScope® videolaryngoscope (GVL) is widely used in patients with difficult airways and provides a good glottic view. However, the acute angle of the blade can make insertion and advancement of an endotracheal tube (ETT) more difficult than direct laryngoscopy, and the use of a stylet is recommended. This randomized controlled trial compared Parker Flex-It™ stylet (PFS) with GlideRite® rigid stylet (GRS) to facilitate intubation with the GVL in simulated difficult intubations. Methods: Fifty-four patients were randomly allocated to undergo GVL intubation using either GRS (GRS group) or PFS (PFS group). The total intubation time (TIT), 100-mm visual analog scale (VAS) for ease of intubation, success rate at the first attempt, use of laryngeal manipulation, tube advancement rate by assistant, and complications were recorded. Results: There was no significant difference between the GRS and PFS groups regarding TIT (50.3 ± 12.0 s in the GRS group and 57.8 ± 18.8 s in the PFS group, P = 0.108). However, intubation was more difficult in the PFS group than in the GRS group according to VAS score (P = 0.011). Cases in which the ETT was advanced from the stylet by an assistant, were more frequent in the GRS group than in the PFS group (P = 0.002). The overall incidence of possible complications was not significantly different. Conclusions: In patients with a simulated difficult airway, there was no difference in TIT using either the PFS or GRS. However, endotracheal intubation with PFS is more difficult to perform than GRS.