Sungwook Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sungwook Park has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Hojun Kim
Center for Advanced Biomolecular Recognition Korea Institute of Science and Technology (KIST) Seoul Republic of Korea
5 shared publications - Kwan Hyi Lee
Korea Institute of Science and Technology
5 shared publications - Hyung Joon Park
Korea Institute of Science and Technology
3 shared publications Youngdo Jeong
Center for Advanced Biomolecular Recognition, Biomedical Research Division, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, University of Science and Technology (UST), Seoul, Republic of Korea; Department of HY-KIST Bio-convergence, Hanyang University, Seoul, 04763, Republic of Korea
3 shared publications- Hyunro Kim2 shared publications
Ji Sung Shim
Department of Urology, Korea University, School of Medicine, Seoul, 02841, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 9 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 189, 109980
Precision screening with sequential multi-algorithm reclassification technique (SMART): Saving bladders from unnecessary cystectomy
- 9 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 189, 109980
Open AccessPrecision screening with sequential multi-algorithm reclassification technique (SMART): Saving bladders from unnecessary cystectomy
- Open Access
- 21 January 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 506
Catapult-like DNA actuator for highly stable and ultrasensitive detection of urinary miRNA
- 21 January 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 506
Open AccessCatapult-like DNA actuator for highly stable and ultrasensitive detection of urinary miRNA
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (66) , 4990
Functional Group Discrimination of Neurotransmitters: A MOF-Based Electrochemical Sensor Array Approach
In the realm of small-molecule analysis, specifically neurotransmitters, the use of extended-gate field-effect transistor (EG-FET) transducers face hurdles due to the absence of target-specific receptors and interference from high-ionic-strength media. To address this challenge, our study introduces a novel approach employing two-dimensional conductive metal-organic frameworks (MOFs) as sensing components for EG-FET biosensors targeting neurotransmitters. By applying thin films of conductive MOFs onto the extended gate of EG-FET, we achieved remarkable sensitivity, enabling the detection of catecholamines in physiological solutions, even at an ultra-low concentration of around 2nM. The adsorption of analytes within the MOFs led to consistent voltage shifts, effectively mitigating the Debye shielding effect, regardless of the ionic strength of the sensing media. Furthermore, our research demonstrated the potential of a diverse MOF sensor array to distinguish chemically similar neurotransmitters through unique adsorption patterns, attributed to the tunable physicochemical properties of MOFs, such as pore size and surface characteristics. Notably, our study showcased the MOF sensor array's ability to simultaneously discriminate neurotransmitters amidst the presence of biologically relevant substances and artificial cerebrospinal fluid, highlighting its robustness in complex environments.
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (66) , 4990
Functional Group Discrimination of Neurotransmitters: A MOF-Based Electrochemical Sensor Array Approach
In the realm of small-molecule analysis, specifically neurotransmitters, the use of extended-gate field-effect transistor (EG-FET) transducers face hurdles due to the absence of target-specific receptors and interference from high-ionic-strength media. To address this challenge, our study introduces a novel approach employing two-dimensional conductive metal-organic frameworks (MOFs) as sensing components for EG-FET biosensors targeting neurotransmitters. By applying thin films of conductive MOFs onto the extended gate of EG-FET, we achieved remarkable sensitivity, enabling the detection of catecholamines in physiological solutions, even at an ultra-low concentration of around 2nM. The adsorption of analytes within the MOFs led to consistent voltage shifts, effectively mitigating the Debye shielding effect, regardless of the ionic strength of the sensing media. Furthermore, our research demonstrated the potential of a diverse MOF sensor array to distinguish chemically similar neurotransmitters through unique adsorption patterns, attributed to the tunable physicochemical properties of MOFs, such as pore size and surface characteristics. Notably, our study showcased the MOF sensor array's ability to simultaneously discriminate neurotransmitters amidst the presence of biologically relevant substances and artificial cerebrospinal fluid, highlighting its robustness in complex environments.
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (66) , 4995
Multi-Marker Biosensor Integrated Explainable AI-Based Cancer Screening System
The Prostate Imaging Reporting and Data System (PI-RADS) score, which is widely used for prostate MRI screening, has established itself as a standard approach for detecting prostate cancer (PCa) due to its reliable diagnostic performance. However, PI-RADS 3 lesions present a significant clinical challenge, as the system delivers only 30 to 40% diagnostic accuracy and is frequently associated with a high rate of false positives. To tackle this issue, we introduce a prostate cancer screening system powered by explainable artificial intelligence (XAI), which incorporates a highly sensitive electrochemical biosensor based on a dual-gate field-effect transistor (DGFET). This innovative system is designed to improve the identification of ambiguous lesions by analyzing the electrochemical sensing profiles of three specific urinary exosomal biomarkers. By generating interpretable results, it allows clinicians to make more confident and evidence-based decisions. Our findings reveal that the XAI-powered PCa screening system achieves impressive diagnostic accuracy, with an area under the curve (AUC) of 0.93, as demonstrated using 102 blinded samples through a non-invasive process. Remarkably, in cases involving PI-RADS 3 lesions, the system more than doubled the diagnostic accuracy compared to traditional PI-RADS scoring methods. Furthermore, the system identified TMEM256 as a crucial biomarker in the accurate diagnosis of PI-RADS 3 lesions, offering clear insight into its decision-making rationale. This study underscores the promise of integrating XAI with electrochemical biosensing to aid healthcare professionals in delivering more informed and evidence-backed diagnoses for prostate cancer, particularly in complex cases.
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (66) , 4995
Multi-Marker Biosensor Integrated Explainable AI-Based Cancer Screening System
The Prostate Imaging Reporting and Data System (PI-RADS) score, which is widely used for prostate MRI screening, has established itself as a standard approach for detecting prostate cancer (PCa) due to its reliable diagnostic performance. However, PI-RADS 3 lesions present a significant clinical challenge, as the system delivers only 30 to 40% diagnostic accuracy and is frequently associated with a high rate of false positives. To tackle this issue, we introduce a prostate cancer screening system powered by explainable artificial intelligence (XAI), which incorporates a highly sensitive electrochemical biosensor based on a dual-gate field-effect transistor (DGFET). This innovative system is designed to improve the identification of ambiguous lesions by analyzing the electrochemical sensing profiles of three specific urinary exosomal biomarkers. By generating interpretable results, it allows clinicians to make more confident and evidence-based decisions. Our findings reveal that the XAI-powered PCa screening system achieves impressive diagnostic accuracy, with an area under the curve (AUC) of 0.93, as demonstrated using 102 blinded samples through a non-invasive process. Remarkably, in cases involving PI-RADS 3 lesions, the system more than doubled the diagnostic accuracy compared to traditional PI-RADS scoring methods. Furthermore, the system identified TMEM256 as a crucial biomarker in the accurate diagnosis of PI-RADS 3 lesions, offering clear insight into its decision-making rationale. This study underscores the promise of integrating XAI with electrochemical biosensing to aid healthcare professionals in delivering more informed and evidence-backed diagnoses for prostate cancer, particularly in complex cases.
- Open Access
- 10 September 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 267, 116773
Explainable artificial intelligence-driven prostate cancer screening using exosomal multi-marker based dual-gate FET biosensor
- 10 September 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 267, 116773
Open AccessExplainable artificial intelligence-driven prostate cancer screening using exosomal multi-marker based dual-gate FET biosensor
- 21 December 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 456
Modular conductive MOF-gated field-effect biosensor for sensitive discrimination on the small molecular scale
- 21 December 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 456
Modular conductive MOF-gated field-effect biosensor for sensitive discrimination on the small molecular scale
- 28 December 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (1) , 50-57
SARS-CoV-2 Variant Screening Using a Virus-Receptor-Based Electrical Biosensor
SARS-CoV-2 variants are of particular interest because they can potentially increase the transmissibility and virulence of COVID-19 or reduce the effectiveness of available vaccines. However, screening SARS-CoV-2 variants is a challenge because biosensors target viral components that can mutate. One promising strategy is to screen variants via angiotensin-converting enzyme 2 (ACE2), a virus receptor shared by all known SARS-CoV-2 variants. Here we designed a highly sensitive and portable COVID-19 screening biosensor based on the virus receptor. We chose a dual-gate field-effect transistor to overcome the low sensitivity of virus-receptor-based biosensors. To optimize the biosensor, we introduced a synthetic virus that mimics the important features of SARS-CoV-2 (size, bilayer structure, and composition). The developed biosensor successfully detected SARS-CoV-2 in 20 min and showed sensitivity comparable to that of molecular diagnostic tests (∼165 copies/mL). Our results indicate that a virus-receptor-based biosensor can be an effective strategy for screening infectious diseases to prevent pandemics.
- 28 December 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (1) , 50-57
SARS-CoV-2 Variant Screening Using a Virus-Receptor-Based Electrical Biosensor
SARS-CoV-2 variants are of particular interest because they can potentially increase the transmissibility and virulence of COVID-19 or reduce the effectiveness of available vaccines. However, screening SARS-CoV-2 variants is a challenge because biosensors target viral components that can mutate. One promising strategy is to screen variants via angiotensin-converting enzyme 2 (ACE2), a virus receptor shared by all known SARS-CoV-2 variants. Here we designed a highly sensitive and portable COVID-19 screening biosensor based on the virus receptor. We chose a dual-gate field-effect transistor to overcome the low sensitivity of virus-receptor-based biosensors. To optimize the biosensor, we introduced a synthetic virus that mimics the important features of SARS-CoV-2 (size, bilayer structure, and composition). The developed biosensor successfully detected SARS-CoV-2 in 20 min and showed sensitivity comparable to that of molecular diagnostic tests (∼165 copies/mL). Our results indicate that a virus-receptor-based biosensor can be an effective strategy for screening infectious diseases to prevent pandemics.