Jen-Yuh Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jen-Yuh Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ching-Yu Lee
Taipei Medical University Hospital
1 shared publication - Christopher Wu
Department of Surgery University of Alabama at Birmingham Birmingham Alabama USA
1 shared publication - Meng-Huang Wu
Department of Orthopedics, Taipei Medical University Hospital, Taipei, Taiwan
1 shared publication - Nobuei Fukui
Department of Orthopaedic Surgery, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
1 shared publication - Shih-Hsiang Chou
Department of Orthopedics, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
1 shared publication - Tsung-Jen Huang
Department of orthopedics, Taipei Medical University Hospital, Taipei 11031, Taiwan
1 shared publication
Latest Publications
- Open Access
- 31 December 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (1) , 220
Comparison of Robotic and Conventional Unicompartmental Knee Arthroplasty Outcomes in Patients with Osteoarthritis: A Retrospective Cohort Study
Robotic-arm-assisted unicompartmental knee arthroplasty (RUKA) was developed to increase the accuracy of bone alignment and implant positioning. This retrospective study explored whether RUKA has more favorable overall outcomes than conventional unicompartmental knee arthroplasty (CUKA). A total of 158 patients with medial compartment osteoarthritis were recruited, of which 85 had undergone RUKA with the Mako system and 73 had undergone CUKA. The accuracy of component positioning and bone anatomical alignment was compared using preoperative and postoperative radiograph. Clinical outcomes were evaluated using questionnaires, which the patients completed preoperatively and then postoperatively at six months, one year, and two years. In total, 52 patients from the RUKA group and 61 from the CUKA group were eligible for analysis. The preoperative health scores and Kellgren–Lawrence scores were higher in the RUKA group. RUKA exhibited higher implant positioning accuracy, thus providing a superior femoral implant angle, properly aligned implant placement, and a low rate of overhang. RUKA also achieved higher accuracy in bone anatomical alignment (tibial axis angle and anatomical axis angle) than CUKA, but surgical time was longer, and blood loss was greater. No significant differences were observed in the clinical outcomes of the two procedures.
- 31 December 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (1) , 220
Open AccessComparison of Robotic and Conventional Unicompartmental Knee Arthroplasty Outcomes in Patients with Osteoarthritis: A Retrospective Cohort Study
Robotic-arm-assisted unicompartmental knee arthroplasty (RUKA) was developed to increase the accuracy of bone alignment and implant positioning. This retrospective study explored whether RUKA has more favorable overall outcomes than conventional unicompartmental knee arthroplasty (CUKA). A total of 158 patients with medial compartment osteoarthritis were recruited, of which 85 had undergone RUKA with the Mako system and 73 had undergone CUKA. The accuracy of component positioning and bone anatomical alignment was compared using preoperative and postoperative radiograph. Clinical outcomes were evaluated using questionnaires, which the patients completed preoperatively and then postoperatively at six months, one year, and two years. In total, 52 patients from the RUKA group and 61 from the CUKA group were eligible for analysis. The preoperative health scores and Kellgren–Lawrence scores were higher in the RUKA group. RUKA exhibited higher implant positioning accuracy, thus providing a superior femoral implant angle, properly aligned implant placement, and a low rate of overhang. RUKA also achieved higher accuracy in bone anatomical alignment (tibial axis angle and anatomical axis angle) than CUKA, but surgical time was longer, and blood loss was greater. No significant differences were observed in the clinical outcomes of the two procedures.