Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yula Cherpelis Serpanos has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Deborah Senzer

    Adelphi University, Department of Communication Sciences and Disorders, Garden City, NY

    5 shared publications
  • Brittany Renne

    Department of Communication Sciences and Disorders, Adelphi University, Garden City, NY

    3 shared publications
  • Diane Davis

    Department of Communication Sciences and Disorders, Adelphi University, Garden City, New York

    2 shared publications
  • Janet R. Schoepflin

    Department of Communication Sciences and Disorders, Adelphi University, Garden City, New York

    2 shared publications
  • Abbey L. Berg

    Pace University, New York, NY

    1 shared publication
  • Abbey L. Berg

    Department of Communication Sciences and Disorders, College of Health Professions, Pace University, New York, USA

    1 shared publication

Latest Publications

  • Outcomes From an Interprofessional Preschool Hearing Health Education Program

    by Yula C. Serpanos, Susan Hendler Lederer

    Purpose: Outcomes from an interprofessional preschool hearing health education curriculum, Love My Ears (LME), are presented. LME was developed by an audiologist, speech-language pathologist, and early childhood educator and was presented previously. The importance and efficacy of early hearing health education are discussed. Method: LME was delivered as a 5-week pull-out program for three separate groups of six children each (total = 18) in a preschool educational setting. Three broad concept areas were taught: sound/hearing, volume/sound safety, and steps for hearing protection. Postprogram assessments were conducted and reported for 15 children ( M age = 4.9 years). The assessment evaluated knowledge of 12 concepts within the three broad concept areas. Descriptive statistics were used to evaluate the efficacy of the LME program. The number and percentage of children that correctly identified each of the concept items were tallied. A correct overall response of 80% or greater was considered indicative of the successful achievement of a concept item. Results: Outcomes revealed the greatest accuracy (≥ 80%) in descriptive concepts related to sound/hearing (2/4), volume/sound safety (2/4), and hearing protection (4/4), supporting the efficacy of preschool hearing health education. Topic-specific vocabulary was less well learned. Conclusion: These outcomes revealed that hearing health education using a specifically designed interprofessional curriculum such as LME is effective in a preschool population.

  • Open Access

    Effect of Sound Preference on Loudness Tolerance and Preferred Listening Levels Using Personal Listening Devices

    by Yula C. Serpanos, Thomas DiBlasi, Jasmin Butler

    Background/Objectives: This study examined the effect of sound preference on loudness tolerance (LTLs) and preferred listening levels (PLLs) using personal listening devices (PLDs). The implication of this relationship on hearing health promotion counseling and practices using PLDs is discussed. Methods: Participants were 50 individuals, aged 21 to 90 years, with normal hearing or hearing loss. Listeners rated several sound samples (i.e., music, running speech, and machinery noise) played through a PLD using earphones according to their sound preference (i.e., enjoyable, acceptable, and unpleasant) and then self-adjusted the volume setting to their LTL and PLL for a sound sample in each sound preference category. Results: Most listeners judged music (70%) as enjoyable, running speech (54%) as acceptable, and machinery noise (84%) as unpleasant. No significant differences were found in LTLs according to sound preference, but PLLs for enjoyable sounds occurred at significantly higher levels compared with those deemed acceptable or unpleasant. Conclusions: Listeners using PLDs perceived LTLs and PLLs differently according to their sound preferences. PLLs occurred at significantly higher volumes for sounds deemed enjoyable when using PLDs. The implication is that hearing health counseling should include information to PLD users on the potential of altered loudness perception with enjoyable sounds, which may lead to higher and riskier PLD listening levels.


  • Open Access

    Adapting Audiology Procedures During the Pandemic: Validity and Efficacy of Testing Outside a Sound Booth

    by Yula C. Serpanos, Melissa Hobbs, Karina Nunez, Lucia Gambino, Jasmin Butler

    Purpose: This investigation aims to provide outcomes from a clinical perspective on the validity and efficacy of a wireless automated audiometer system that could be used in multiple settings when a sound booth is not accessible. Testing was conducted in a clinical setting under modified protocols meeting safety precautions during the COVID-19 pandemic. Method: Four doctoral students in audiology served as examiners. Participants were 69 adults between the ages of 20 and 69 years, with normal hearing (≤ 25 dB HL; n = 110 ears) or hearing loss (> 25 dB HL; n = 25 ears). Two versions of a pure-tone air-conduction threshold test following a modified Hughson-Westlake approach were performed and compared at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz (a) in a sound-treated test booth using standard manual audiometry and (b) in a quiet, nonsound-treated clinical room (sound booth free) using automated KUDUwave audiometry. Participants were asked to complete a five-item feedback questionnaire, and examiners were interviewed to report on their experience. Results: Clinical validity to within ±10 dB of standard audiometry was demonstrated for 94.5% of the total thresholds ( n = 937) measured with the sound booth–free approach. Less accuracy (73.3%) was observed using a ±5 dB comparison. When comparing the mean thresholds, there were significant differences ( p < .01) between the mean thresholds at most frequencies, with mean sound booth thresholds being higher than the sound booth–free mean thresholds. A strong threshold correlation (.91–.98) was found between the methods across frequencies. Participant and examiner feedback supported the efficacy of the sound booth–free technology. Conclusions: Findings support sound booth–free, automated software-controlled audiometry with active noise monitoring as a valid and efficient procedure for pure-tone hearing threshold assessment. This method offers an effective alternative when circumstances require more transportable hearing assessment technology or do not allow for standard manual audiometry in a sound booth.


  • The Accuracy of Smartphone Sound Level Meter Applications (SLMAs) in Measuring Sound Levels in Clinical Rooms

    by Yula C. Serpanos, Janet R. Schoepflin, Steven R. Cox, Diane Davis

    Background The accuracy of smartphone sound level meter applications (SLMAs) has been investigated with varied results, based on differences in platform, device, app, available features, test stimuli, and methodology. Purpose This article determines the accuracy of smartphone SLMAs with and without calibration of external and internal microphones for measuring sound levels in clinical rooms. Research Design Quasi-experimental research design comparing the accuracy of two smartphone SLMAs with and without calibration of external and internal microphones. Data Collection and Analysis Two iOS-based smartphone SLMAs (NIOSH SLM and SPL Meter) on an iPhone 6S were used with and without calibrated external and internal microphones. Measures included: (1) white noise (WN) stimuli from 20 to 100 dB sound pressure level in a sound-treated test booth and (2) sound levels in quiet in four nonsound-treated clinical rooms and in simulated background sound conditions using music at 45, 55, and 80 dBA. Chi-square analysis was used to determine a significant difference (p ≤ 0.05) in sound measures between the SLMAs and a Type 1 SLM. Results Measures of WN signals and room sound level measures in quiet and simulated background sound conditions were significantly more accurate at levels ≥ 40 dBA using the SLMAs with calibrated external and internal microphones. However, SLMA measures with and without calibration of external and internal microphones overestimated sound levels < 40 dBA. Conclusion The SLMAs studied with calibrated external or internal microphones are able to verify the room environment for audiologic screening at 1,000, 2,000, and 4,000 Hz at 20 dB hearing level (American Academy of Audiology and American Speech-Language-Hearing Association) using supra-aural earphones (American National Standards Institute S3.1‐1999 [R2018]). However, the tested SLMAs overestimated low-level sound < 40 dBA, even when the external or internal microphones were calibrated. Clinicians are advised to calibrate the microphones prior to using measurement systems involving smartphones and SLMAs to measure room sound levels and to monitor background noise levels throughout the provision of clinical services.


  • Accuracy of Smartphone Self-Hearing Test Applications Across Frequencies and Earphone Styles in Adults

    by Jessica Barczik, Yula C. Serpanos

    Purpose: The purpose of this study is to evaluate smartphone-based self-hearing test applications (apps) for accuracy in threshold assessment and validity in screening for hearing loss across frequencies and earphone transducer styles. Method: Twenty-two adult participants (10 = normal hearing ; 12 = sensorineural hearing loss ; n = 44 ears) underwent conventional audiometry and performed 6 self-administered hearing tests using two iPhone-based apps (App 1 = uHear [Version 2.0.2, Unitron]; App 2 = uHearingTest [Version 1.0.3, WooFu Tech, LLC.]) each with 3 different transducers (earbud earphones, supra-aural headphones, circumaural headphones). Hearing sensitivity results using the smartphone apps across frequencies and transducers were compared with conventional audiometry. Results: Differences in accuracy were revealed between the hearing test apps across frequencies and earphone styles. The uHear app using the iPhone standard EarPod earbud earphones was accurate to conventional thresholds ( p > .002 with Bonferroni correction) at 1000, 2000, 4000, and 6000 Hz and found valid (81%–100% sensitivity, specificity, positive and negative predictive values) for screening mild or greater hearing loss (> 25 dB HL) at 500, 1000, 2000, 4000, and 6000 Hz. The uHearingTest app was accurate in threshold assessment and determined valid for screening mild or greater hearing loss (> 25 dB HL) using supra-aural headphones at 2000, 4000, and 8000 Hz. Conclusions: Self-hearing test apps can be accurate in hearing threshold assessment and screening for mild or greater hearing loss (> 25 dB HL) when using appropriate transducers. To ensure accuracy, manufacturers should specify earphone model instructions to users of smartphone-based self-hearing test apps.


  • The Accuracy of Smartphone Sound Level Meter Applications With and Without Calibration

    by Yula C. Serpanos, Brittany Renne, Janet R. Schoepflin, Diane Davis

    Purpose: The purpose of this study is to determine the accuracy of smartphone sound level meter applications (SLMAs) with calibration features across stimulus levels and for ambient room noise measures in the clinical setting. Method: The accuracy of 3 iOS-based smartphone SLMAs (SLMA1: Analyzer [Version 2.7.2, DSP Mobile], SLMA2: Sound Level Meter Pro [Version 2.2, Mint Muse LLC], and SLMA3: SPL Meter [Version 9.3, Andrew Smith, Studio Six Digital]), using a single smartphone device (iPhone 6S Model A1688, iOS 9.3.4, Apple), was evaluated with and without calibration using a 1000-Hz narrowband noise (NBN) and white noise (WN) stimuli over a range of sound levels (20–100 dB) and in ambient noise measures of 8 speech and hearing room environments. A simultaneous and corresponding SLMA and Type 1 sound level meter (SLM) measure per condition were documented with a photo image; each condition was replicated 5 times. Mean SLMA and SLM measures were compared. SLMA measures were considered accurate if within ± 2 dB of the SLM. Results: Measures of NBN and WN signals using these SLMAs were accurate at levels above 40–50 dB when calibrated. NBN and WN signals using some SLMAs were significantly ( p < .05) more accurate with calibration at levels > 40 to 50 dB. SLMA measures with or without calibration adjustment were inaccurate and overestimated room ambient noise levels < 50 dB. Conclusions: These findings suggest that some SLMAs are accurate for measuring NBN and WN stimuli within the range of 50–100 dB in sound-treated environments when calibrated. However, outcomes indicated that some SLMAs, even with calibration, overestimated low ambient noise levels and may not accurately verify quiet room environments < 50 dB for clinical services. These results should not be generalized for all smartphone types, and continued research on SLMAs using next-generation smartphone devices is warranted.


  • Interprofessional Peer-Assisted Learning as a Model of Instruction in Doctor of Audiology Programs

    by Yula C. Serpanos, Deborah Senzer, Daryl M. Gordon

    Purpose: This study reports on interprofessional peer-assisted learning (PAL) as a model of instruction in the preparation of doctoral audiology students. Method: Ten Doctor of Audiology (AuD) students provided training in audiologic screening for 53 graduate speech-language pathology students in 9 individual PAL sessions. Pre- and post-surveys assessed the peer teaching experience for AuD students in 5 areas of their confidence in audiologic screening: knowledge, skill, making a referral based on outcomes, teaching, and supervising. Pre- and post-learning outcomes in audiologic screening for the speech-language pathology student trainees determined the effectiveness of training by their AuD student peers. Results: Survey outcomes revealed significant ( p < .001) improvement in the overall confidence of AuD student peer instructors. Speech-language pathology students trained by their AuD peers exhibited significant ( p = .003) improvements in their knowledge and skill and making outcome-based referrals in audiologic screening, supporting the effectiveness of the PAL paradigm. Conclusions: In addition to meeting required accreditation and professional certification competency standards, the PAL instructional model offers an innovative curricular approach in interprofessional education and in the teaching and supervisory preparation of students in doctoral audiology programs.


  • Influence of Hearing Risk Information on the Motivation and Modification of Personal Listening Device Use

    by Yula C. Serpanos, Abbey L. Berg, Brittany Renne

    Purpose: The purpose of this study was (a) to investigate the behaviors, knowledge, and motivators associated with personal listening device (PLD) use and (b) to determine the influence of different types of hearing health risk education information (text with or without visual images) on motivation to modify PLD listening use behaviors in young adults. Method: College-age students ( N = 523) completed a paper-and-pencil survey tapping their behaviors, knowledge, and motivation regarding listening to music or media at high volume using PLDs. Participants rated their motivation to listen to PLDs at lower volume levels following each of three information sets: text only, behind-the-ear hearing aid image with text, and inner ear hair cell damage image with text. Results: Acoustically pleasing and emotional motives were the most frequently cited (38%–45%) reasons for listening to music or media using a PLD at high volume levels. The behind-the-ear hearing aid image with text information was significantly ( p < .0001) more motivating to participants than text alone or the inner ear hair cell damage image with text. Conclusions: Evocative imagery using hearing aids may be an effective approach in hearing protective health campaigns for motivating safer listening practices with PLDs in young adults.


  • The Efficacy of Routine Screening for High-Frequency Hearing Loss in Adults and Children

    by Yula C. Serpanos, Deborah Senzer, Brittany Renne, Rebecca Langer, Roxanne Hoffman

    Purpose: This study was conducted to investigate the efficacy of routine screening for high-frequency hearing loss (HFHL) including 3000, 6000, and 8000 Hz frequencies with conventional test frequencies (1000, 2000, and 4000 Hz) in adults and children in a university outreach program. Method: Screening outcomes were examined in 2 cohorts of adults (Cohort 1, N = 315, M = 66.2 years; Cohort 2, N = 67, M = 68.3 years) and children (Cohort 1, N = 177, M = 6.5 years; Cohort 2, N = 57, M = 6.9 years) with a high-frequency screen protocol (1000–8000 Hz at 25 dB HL for adults and 20 dB HL for children) using supra-aural headphones. A rescreen was conducted in Cohort 2 with a modified protocol using insert earphones and monitored ambient noise levels. Results: Average total test time significantly increased ( p < .0001) and nearly doubled with inclusion of 3000-, 6000-, and 8000-Hz frequencies, adding approximately 1 min. Rescreen referral rates decreased by approximately 2%–16% at 1000–8000 Hz (approximately 13%–16% at 6000 and 8000 Hz) using the modified protocol in adults and children, supporting false-positive responses using supra-aural headphones. Conclusion: Screening for HFHL should include insert earphones in order to prevent potential errors, particularly at 6000 and 8000 Hz.


  • Survey of Speech-Language Pathology Graduate Program Training in Outer and Middle Ear Screening

    by Yula C. Serpanos, Deborah Senzer

    Purpose: The purpose of this study was to determine the national training practices of speech-language pathology graduate programs in outer and middle ear screening. Method: Directors of all American Speech-Language-Hearing Association–accredited speech-language pathology graduate programs (N = 254; Council on Academic Accreditation in Audiology and Speech-Language Pathology, 2013) were surveyed on instructional formats in outer and middle ear screening. Results: The graduate speech-language pathology program survey yielded 84 (33.1%) responses. Results indicated that some programs do not provide any training in the areas of conventional screening otoscopy using a handheld otoscope (15.5%; n = 13) or screening tympanometry (11.9%; n = 10), whereas close to one half (46.4%; n = 39) reported no training in screening video otoscopy. Outcomes revealed that approximately one third or more of speech-language pathology graduate programs do not provide experiential opportunities in screening handheld otoscopy (36.9%) or tympanometry (32.1%), and most (78.6%) do not provide experiential opportunities in video otoscopy. Conclusions: The implication from the graduate speech-language pathology program survey findings is that some speech-language pathologists will graduate from academic programs without the acquired knowledge or experiential learning required to establish skill in 1 or more areas of screening otoscopy and tympanometry. Graduate speech-language pathology programs should consider appropriate training opportunities for students to acquire and demonstrate skill in outer and middle ear screening.