ВБВладимир Викторович Белобородов

Владимир Викторович Белобородов

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Владимир Викторович Белобородов has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Aleksey G. Filippenko

    Meshalkin National Medical Research Center

    9 shared publications
  • Vitaliy V. Shabanov

    Academician E.N. Meshalkin National Medical Research Center, Novosibirsk

    9 shared publications
  • Alexander Romanov

    Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации

    8 shared publications
  • Igor L. Mikheenko

    Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации, Новосибирск

    6 shared publications
  • E. V. Fisher

    Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации, Новосибирск

    3 shared publications
  • V.I. Murtazin

    Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации, Новосибирск

    3 shared publications

Latest Publications

  • Open Access

    THE ROLE OF THE LEFT ATRIAL APPENDAGE IN THE PATHOGENESIS OF ATRIAL FIBRILLATION, THE EFFECTIVENESS OF ABLATION AND THE DEVELOPMENT OF THROMBOEMBOLIC COMPLICATIONS

    by Алексей Германович Филиппенко, Владимир Викторович Белобородов, Дмитрий Анатольевич Елесин, Илья Геннадьевич Стенин, Наталия Васильевна Широкова, Вера Викторовна Баранова, Виталий Викторович Шабанов

    HighlightsLeft atrial appendage resection is a safe and effective method of excluding the appendage from the systemic circulation, it reduces the number of cerebral ischemic events and increases the effectiveness of atrial fibrillation treatment. AbstractAccording to a number of studies, left atrial appendage can be the source of atrial fibrillation. Moreover, in atrial tachyarrhythmias, the appendage is the main source of thrombosis that causes cerebral ischemic events. In an attempt to solve these two issues, specialists developed various devices to exclude the left atrial appendage from the systemic circulation and attempted to ablate the arrhythmogenic area. The aim of this review is to analyze current literature data on the abovementioned issues and our own experience of left atrial appendage resection during thoracoscopic pulmonary vein ablation in patients with persistent atrial fibrillation.


  • Open Access

    Remote magnetic-guided navigation versus manual radiofrequency ablation approach in the interventional treatment of patients with atrial fibrillation and enlarged left atrium: propensity-score matching assessment

    by A.B. Romanov, V.V. Beloborodov, V.V. Shabanov, A.G. Filippenko, D.A. Elesin, V.A. Boboshko, S.YE. Khrushchev, P.S. Ruzankin, С.е. Хрущев

    Introduction: Pulmonary vein ostia isolation (PVI) is the main method for catheter ablation (CA) in patients with atrial fibrillation (AF) who are refractory to antiarrhythmic drug therapy (AAD). The data regarding comparison of the remote magnetic-guided navigation (RMN) and manual (MAN) radiofrequency ablation approaches for PVI in patients with AF and enlarged left atrium (LA) are limited.Objective: The study was aimed to comparison of the safety and long-term efficacy of the radiofrequency CA associated with RMN and MAN using in patients with AF and enlarged LA.Methods: The retrospective cohort included 534 patients (mean age 59.2 ± 8.7 years, 41.6% female) with different AF forms and LA >4.5 cm who underwent PVI between 2016 and 2019. The patients were divided into two groups: the RMN group (n = 267) and MAN group (n = 267). The primary safety objective was associated with preventing perisurgical complications, and the primary efficacy objective was disengagement from AF / atrial flutter (AFl) / AT (atrial tachycardia), lasting > 30 seconds, in the 3-month period after the index procedure without AAD. The comparison of the results with 1:1 propensity score matching (PSM) was applied on the basis of 11 covariates. After PSM, 235 patients were selected for each group. The entire cohort was additionally divided into the subgroups of paroxysmal AF (n = 355) and non-paroxysmal AF (n = 179) to increase efficacy assessment. After PSM, 310 and 136 patients with paroxysmal and non-paroxysmal AF were analyzed, respectively.Results: In the entire cohort after PSM (n = 470) patients were balanced completely according to AF forms. The mean values of LA diameter were 4.98 ± 0.61 cm and 4.94 ± 0.58 cm in the RMN and MAN groups, respectively. The long-term efficacy assessment was performed in 448 patients of the both groups excluding 22 (4.7%) patients due to failed contacts. The median follow-up period was 24 months (minimum 3 and maximum 72 months). In the matched cohorts, perisurgical complications were detected in 11 (4.7%) patients of the MAN group and 2 (0.9%) patients of the RMN group (Р = 0.021, OR = 5.7; 95% CI [1.22, 53.5]). The disengagement from AF/AFl/AT after 36 months of the follow up amounted to 62.6% in the RMN group and 47.9% in the MAN group (for entire follow up, P = 0.005, HR = 1.54; 95% CI [1.14, 2.08]). For paroxysmal AF subgroup (n = 310), the disengagement from AF/AFl/AT after 36 months of the follow was 67.1% in the RMN group and 60.6% in the MAN group (for entire follow up, P = 0.15, HR = 1.34; 95% CI [0.90, 1.98]). In the non-paroxysmal AF subgroup (n = 136), the disengagement from AF/AFl/AT after 36 months of the follow up was higher in the RMN group as compared to the MAN group (59.6% and 30.4%, respectively, for entire follow up, P = 0.005, HR = 2.01; 95% CI [1.23, 3.29]) predominantly due to persistent AF.Conclusion: The present propensity-score matching study evidentiated that RMN CA was superior over manual CA for the interventional treatment of patients with AF and enlarged LA with respect to perisurgical complications and long-term disengagement from AF/AFl/AT predominantly due to non-paroxysmal AF. Prospective randomized studies are recommended for the comparison of the outcomes related to RMN and manual CA in patients with AF and enraged LA. Received 24 April 2024. Accepted 8 May 2024. Funding: Work by P.S. Ruzankin and S.E. Khrushchev was carried out within the framework of the state assignment of the Sobolev Institute of Mathematics of the Siberian Branch of the Russian Academy of Sciences, project FWNF-2024-0001. Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: A.B. Romanov, V.V. Beloborodov, V.V. Shabanov, A.G. FilippenkoData collection and analysis: V.V. Beloborodov, A.B. Romanov, D.A. Elesin, V.A. Boboshko, V.V. Shabanov, A.G. Filippenko Statistical analysis: P.S. Ruzankin, S.Ye. Khrushchev, A.B. RomanovDrafting the article: A.B. Romanov, V.V. Beloborodov, P.S. Ruzankin, S.Ye. KhrushchevCritical revision of the article: A.B. Romanov, V.V. Beloborodov, P.S. Ruzankin, S.Ye. KhrushchevFinal approval of the version to be published: A.B. Romanov, V.V. Beloborodov, V.V. Shabanov, A.G. Filippenko, D.A. Elesin, V.A. Boboshko, S.Ye. Khrushchev, P.S. Ruzankin


  • Open Access

    The impact of spinal cord stimulation on a chronic model of atrial fibrillation in a mini-pig experiment

    by V.V. Shabanov, A.G. Filippenko, V.V. Beloborodov, T.U. Khalkhoghaev, V.I. Murtazin

    Introduction: Despite the advancement interventional methods for treating atrial fibrillation, the effectiveness of catheter ablation remains poor, especially in patients with persistent and long-persistent atrial fibrillation. Thus, experts continue to explore new treatments for this arrhythmia. The issue of experimental studies investigating the association between spinal cord stimulation and atrial fibrillation is mainly attributed to the lack of optimal algorithms for spinal cord stimulation in animal experiments. Therefore, it is important to develop adequate algorithms for spinal cord stimulation in the chronic model of atrial fibrillation.Objective: To evaluate the impact of spinal cord stimulation on the model of atrial fibrillation in mini-pigs.Methods: In a series of experiments, 6 (100%) successful implantations of electrodes and pacemakers, and spinal cord stimulation electrodes were performed. The electrodes were used to stimulate the atria, creating a model of atrial fibrillation, while the spinal cord stimulation was carried out using an electrode implanted into the spinal canal. During the experiment, an electrophysiological study was performed using an implanted pacemaker. The inducibility of atrial fibrillation was assessed before and after the experiment using various spinal cord stimulation algorithms.Results: There were no complications associated with surgery or stimulation of the atria and spinal cord. Spinal stimulation had a modeling effect on the autonomic nervous system, significantly changing the average heart rate, Wenckebach point, and effective refractory period. When comparing spinal stimulation algorithms, algorithm 1 was found to significantly reduce the atrial fibrillation inducibility.Conclusion: Spinal cord stimulation had a modeling effect on the autonomic nervous system, significantly changing the average heart rate, Wenckebach point, and effective refractory period. Inducibility of atrial fibrillation decreases with changes in the spinal pacing algorithm. Received 15 September 2023. Revised 30 October 2023. Accepted 31 October 2023. Funding: The study was supported by Russian Science Foundation (project No. 22-25-00672). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: A.G. Filippenko, V.V. Shabanov, V.I. MurtazinData collection and analysis: A.G. Filippenko, T.U. Khalkhoghaev, V.V. BeloborodovStatistical analysis: A.G. Filippenko, V.V. ShabanovDrafting the article: A.G. Filippenko, V.V. BeloborodovCritical revision of the article: V.V. ShabanovFinal approval of the version to be published: V.V. Shabanov, A.G. Filippenko, V.V. Beloborodov, T.U. Khalkhoghaev, V.I. Murtazin


  • Open Access

    Modulation of the autonomic nervous system for preventing perioperative atrial fibrillation: a review of literature

    by V.V. Shabanov, V.V. Beloborodov, T.U. Khalkhoghaev, V.I. Murtazin, A.G. Filippenko

    Introduction: Autonomic control of the heart is exerted by the neurocardiac axis, which comprises reflexes at three levels of cardiac activity: central (higher structures of the forebrain, brainstem, and spinal cord), intrathoracic extracardiac (stellate and dorsal root ganglia), and intracardiac. Neuromodulation of the autonomic nervous system (ANS) (ganglion plexus ablation, epicardial drug infusion for temporary neurotoxicity, low-level vagus nerve stimulation, stellate ganglion blockade, baroreceptor stimulation, spinal cord stimulation, renal and pulmonary artery nerve fiber denervation) is a new therapeutic approach for managing heart rhythm disorders and cardiovascular pathologies. Atrial fibrillation (AF) occurs in up to 30% of patients after open cardiac surgery and is associated with increased morbidity and mortality in the long-term follow-up. Objective: To evaluate the safety and efficacy of the different neuromodulation approaches for preventing postoperative atrial fibrillation (POAF) in clinical and experimental settings.Conclusion: ANS neuromodulation techniques have demonstrated high efficacy and safety for preventing POAF. Received 21 August 2023. Revised 16 October 2023. Accepted 31 October 2023. Funding: The study was supported by Russian Science Foundation (project No. 22-25-00672). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: V.V. Shabanov, A.G. Filippenko, V.V. BeloborodovDrafting the article: V.V. Shabanov, A.G. Filippenko, T.U. Khalkhoghaev, V.I. MurtazinCritical revision of the article: V.V. ShabanovFinal approval of the version to be published: V.V. Shabanov, V.V. Beloborodov, T.U. Khalkhoghaev, V.I. Murtazin, A.G. Filippenko

  • Open Access

    Remote magnetic-guided catheter ablation versus manual ablation in patients with repaired congenital heart disease and atrial tachyarrhythmias: propensity-matched observational study of long-term results

    by A. B. Romanov, A. G. Filippenko, V. V. Shabanov, V. V. Beloborodov, V. A. Boboshko, S. E. Khrushchev, P. S. Ruzankin

    Aim. To compare the long-term outcomes of the catheter ablation (CA) using remote magnetic-guided navigation (RMN) and manual radiofrequency CA (MAN) in patients with congenital heart defect (CHD) and incisional atrial tach-yarrhythmias (AT).Methods. In this retrospective study cohort, 67 patients were included with CHD and AT. CHD were classified based on complexity (simple, moderate, and complex) according to ACC/AHA guidelines 2008. Fifty-seven (85%) patients underwent at least one surgical procedure for CHD correction before CA. The patients were divided into the two groups regarding CA approach: the MAN group (n=42) and the RMN group (n=25). The primary endpoitnts was long-term freedom from any AT, including atrial fibrillation. Key secondary endpoints included perioperative and late complications. To compare freedom from any AT between the groups, 1:3 propensity score matching was applied, and 63 patients were matched. The matching was exact on CHD complexity. The weighted matched observations were assessed with univariate Cox regression with any AT as the outcome.Results. The median follow-up period was 20 months. In the matched MAN and RMN groups, 92.3% and 83.3% patients, respectively, had incisional АТ (p=0.27), the other patients having additionally AF. The mean fluoroscopy time was statistically significant lower in the RMN group compared with MAN (р=0.009) with longer procedural duration in the RMN group (pConclusion. RMN CA was superior over manual CA with respect to long-term freedom from AT in patients with CHD with similar safety profile.


  • Open Access

    New atrial fibrillation model with endocardial approach by CRT bi-electrode atrial pacing in mini-pigs

    by D.V. Losik, V.V. Beloborodov, E.V. Fisher, V.I. Murtazin, A.G. Filippenko, I.L. Mikheenko, V.V. Shabanov, A.B. Romanov

    Objective: To evaluate the model of atrial fibrillation (AF) in mini-pigs with endocardial approach implantation of CRT-P using bi-electrodes pacing through RV/LV connectors.Methods: All surgical interventions were minimally invasive and conducted under general anaesthesia. CRT-P was implanted endocardially, using X-ray. First electrode was fixed in the right atrial appendage. The second one — in the interatrial septum or the right atrial free wall. Both of them were connected with CRT-P through RV/LV. Bi-electrode atrial stimulation was realized during a week with a basic heart rate of 150 bpm and a delay between electrodes of 80 ms (mean 450 bpm), which corresponds to the heart rate (HR) of AF. Electrophysiological study was performed during the experiment to analyze the cardiac conduction system. AF inducibility was evaluated before and after stimulation.Results: A series of experiments demonstrated that there were no complications following the device and electrodes implantation. There was a non-sustained paroxysm of AF before permanent pacing in one of three pigs. After pacing we noted a tendency to increase the baseline HR (average frequency from 94 ± 4 to 98 ± 6 bpm). Non-sustained paroxysm of AF was induced in all cases. The sustained AF with 92 min burden was induced in one pig.Conclusion: Endocardial bi-electrode atrial pacing in mini-pigs has proven to be safe. This AF model improves AF inducibility and can be considered as an alternative to epicardial stimulation for experiments employing AF models. Received 4 December 2022. Revised 17 January 2023. Accepted 18 January 2023. Funding: The study was supported by Russian Science Foundation (project No. 22-25-00672). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: V.V. Beloborodov, D.V. Losik, E.V. FisherData collection and analysis: E.V. Fisher, V.V. Beloborodov, D.V. Losik, A.G. FilippenkoDrafting the article: D.V. Losik, E.V. Fisher, V.I. Murtazin, V.V. BeloborodovCritical revision of the article: A.B. Romanov, D.V. Losik, V.V. Shabanov, I.L. MikheenkoFinal approval of the version to be published: D.V. Losik, V.V. Beloborodov, E.V. Fisher, V.I. Murtazin, A.G. Filippenko, I.L. Mikheenko, V.V. Shabanov, A.B. Romanov


  • Open Access

    The first experience of using robotic magnetic navigation for interventional treatment of post-incisional atrial flutter in patients with congenital heart defects after surgical correction: case series

    by А. Б. Романов, А. Г. Филиппенко, В. В. Белобородов, I.L. Mikheenko, V.V. Shabanov

    Post-incisional heart rhythm disturbances are one of the most frequent complications after open cardiac surgery. Lession in the atrial myocardium create conditions for slowing impulse conduction, formation and circulation of reentry. Case series included 8 patients after correction of complex congenital heart disease (CHD) with post-incisional atrial flutter (AF), despite treatment with antiarrhythmic drugs. All patients underwent interventional AF treatment using the robotic magnetic navigation (RMN) system. Perioperative complications, duration of surgery, time of fluoroscopy and efficacy (free of atrial tachyarrhythmias 3 months after the ablation procedure) of treatment were assessed during a follow-up period of 12 months. The article presents a series of clinical cases of RMN application for the treatment of post-incisional AF in patients with CHD after open cardiac surgery. The first Russian experience of using RMN for the treatment of post-incisional AF in patients with CHD after open cardiac surgery demonstrated safety and high efficiency both in the early and long-term follow-up periods. More experience and multicenter studies in a large cohort of patients are needed to determine the role of RMN as the first line of therapy for performing catheter ablation in this category of patients. Received 12 November 2021. Accepted 6 December 2021. Informed consent: The patient’s informed consent to use the records for medical purposes is obtained. Funding: The work is supported by a grant of the President of the Russian Federation No. МД-1997.2020.7 Conflict of interest: Authors declare no conflict of interest. Contribution of the authorsLiterature review: V.V. Beloborodov, A.G. FilippenkoDrafting the article: A.B. Romanov, V.V. Beloborodov, A.G. FilippenkoCritical revision of the article: A.B. Romanov, A.G. Filippenko, V.V. Beloborodov, V.V. ShabanovSurgical treatment: A.B. Romanov, V.V. ShabanovFinal approval of the version to be published: A.B. Romanov, A.G. Filippenko, V.V. Beloborodov, I.L. Mikheenko, V.V. Shabanov

  • Open Access

    Remote magnetic navigation for treatment of patients with atrial fibrillation

    by В. В. Белобородов, V.V. Shabanov, N.A. Yelemessov, А. Г. Филиппенко, I.L. Mikheenko, E.V. Fisher, А. Б. Романов

    Atrial fibrillation (AF) remains an important medical and social health problem occupying a leading position among all cardiac arrhythmias in clinical practice. AF increases overall mortality by 1.9 times and the risk of stroke by 5 times, leads to disability among the working-age population, and reduces the quality of life. Pulmonary veins isolation is the main approach in the treatment of AF symptomatic patients who are resistant to antiarrhythmic therapy. However, the use of this technique is associated with the need for long-term use of fluoroscopy and monitoring of the contact force of the ablation catheter with the heart tissue for an effective and safe exposure on the arrhythmia substrate. In addition, the complication rate can reach up to 5% even when using non-fluoroscopic navigation systems. Over the past decade, robotic magnetic navigation was established as a safe and effective technology in the treatment of patients with different cardiac arrhythmias. The advantages of this technology are the flexibility and mobility of the ablation catheter to reach difficult areas during ablation procedure, as well as high efficiency and safety, with a low fluoroscopy exposure time. This review analyses the current literature and documents the experience of using robotic magnetic navigation for the treatment of patients with different forms of AF. We conducted searches on Scopus, Web of Science databases and PubMed. The reviewed studies demonstrated that the use of robotic magnetic navigation is a safe and highly effective method of treating patients with AF. It also helps to reduce the time of fluoroscopy during ablation procedure. Received 26 August 2021. Revised 21 September 2021. Accepted 22 September 2021. Funding: This work was carried out within the framework of the state task of Ministry of Health of Russian Federation No. 121031300225-8. Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: V.V. Beloborodov, A.G. Filippenko, A.B. RomanovData collection and analysis: V.V. Beloborodov, N.А. Yelemessov, E.V. Fisher, A.G. Filippenko, V.V. Shabanov, A.B. RomanovStatistical analysis: A.B. Romanov, I.L. MikheenkoDrafting the article: V.V. Beloborodov, A.G. Filippenko, A.B. RomanovCritical revision of the article: A.B. Romanov, I.L. Mikheenko, A.G. Filippenko, V.V. ShabanovFinal approval of the version to be published: V.V. Beloborodov, V.V. Shabanov, N.А. Yelemessov, A.G. Filippenko, I.L. Mikheenko, E.V. Fisher, A.B. Romanov


  • Open Access

    The role of cardiac biomarkers and epicardial fat in the diagnosis of heart failure in patients with various types of atrial fibrillation

    by D. V. Losik, E. V. Fisher, I. L. Mikheenko, N. A. Nikitin, S. M. Minin, V. V. Beloborodov, A. B. Romanov

    Aim. To assess the level of various cardiac biomarkers and the volume of epicardial adipose tissue (EAT) in patients with heart failure (HF) depending on the type of atrial fibrillation (AF).Material and methods. This prospective observational study included 69 patients with symptomatic AF, as well as with manifestations of New York Heart Association (NYHA) class II-III HF. All patients were examined before catheter ablation for AF. The following investigations were performed: echocardiography, computed tomography, myocardial perfusion scintigraphy, immunochemical analysis of cardiac biomarkers (brain natriuretic peptide (BNP), high-sensitivity troponin I (hs-TnI)), as well as biochemical analysis of high-sensitivity C reactive protein (hsCRP). Patients were divided into 2 groups, depending on the AF type, into paroxysmal and non-paroxysmal (persistent and long-standing persistent).Results. The analysis included 69 patients with various AF types and symptomatic HF. There were significantly more patients with HF confirmed by an elevated BNP level in the group with non-paroxysmal type (27 (71%) vs 5 (16%), pConclusion. The type of AF plays a role in the interpretation of cardiac specific enzymes, and BNP levels and EAT volume are higher in patients with the non-paroxysmal form.


  • Open Access

    Remote magnetic navigation ablation of incisional atrial flutters in adolescent with a giant right atrium after surgical correction of tetralogy of Fallot and Ebstein's anomaly

    by A. B. Romanov, A. V. Bogachev-Prokopiev, S. M. Ivantsov, V. V. Beloborodov, I. L. Mikheenko, V. V. Shabanov

    We describe a clinical case of a 17-years-old adolescent with congenital heart disease after three open-heart surgery procedures for correction of tetralogy of Fallot and Ebstein's anomaly who presented with drug-resistant, persistent atrial flutter and giant right atrium (8.2 cm by transthoracic echocardiography). The successful ablation procedure of the two types of incisional atrial flutter was performed using remote magnetic navigation without any complications with 2.2 minutes of fluoroscopy. The patient remained free of any arrhythmias without antiarrhythmic drugs during 12 months of follow-up with a reduction of right atrium size (5.8 cm by transthoracic echocardiography).