Harim Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Harim Kim has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Ho Yun Lee
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
3 shared publications - Eun Young Ko
Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
2 shared publications Joon Young Choi
Department of Nuclear Medicine and Molecular Imaging, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
2 shared publications- Beomseok Sohn
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Boo-Kyung Han
Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Boo-Kyung Han
Department of Radiology and Center for Imaging Science, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul 06351, Republic of Korea
1 shared publication
Latest Publications
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (3) , 2429-2442
Equilibrium Contrastive Learning for Imbalanced Image Classification
The data imbalance issue is critical in image classification. Contrastive learning (CL) is a predominant technique in image classification, but they showed limited classification performance when the class distribution in a training dataset is skewed (i.e., an imbalanced dataset). Recently, several supervised CL methods have been proposed particularly to promote an ideal regular simplex geometric configuration in the representation space—characterized by intra-class feature collapse and uniform inter-class mean spacing—especially for imbalanced datasets. In particular, existing prototype-based methods include class representatives, i.e., prototypes, as additional samples to achieve a more balanced treatment of all classes. However, the existing supervised CL methods for imbalanced datasets still suffer from two major limitations. First, they do not consider the alignment between the class means/prototypes and linear classifiers, which could lead to poor generalization. Second, existing prototype-based methods treat class prototypes as only one additional sample per class, making their influence depend on the number of class instances in a batch and causing unbalanced contributions across classes. To address these limitations, we propose Equilibrium Contrastive Learning (ECL), a supervised CL framework designed to promote geometric equilibrium in the representation space, where class features, means, and classifiers are harmoniously balanced under data imbalance. The proposed ECL framework uses two main strategies. First, ECL promotes the representation geometric equilibrium (i.e., a regular simplex geometry characterized by collapsed class samples and uniformly distributed class means), while balancing the contributions of class-average features and class prototypes. Second, ECL establishes a classifier-class center geometric equilibrium by aligning classifier weights and class prototypes in the representation space. We ran experiments with three long-tailed natural image datasets, the CIFAR-10-LT, CIFAR-100-LT and ImageNet-LT benchmark datasets, and the two imbalanced medical image classification datasets, the ISIC 2019 benchmark and our constructed lung cancer chest computed tomography dataset. Results with the five imbalanced datasets show that ECL outperforms existing state-of-the-art supervised CL methods designed for imbalanced/long-tailed classification. Codes are available at this link.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (3) , 2429-2442
Equilibrium Contrastive Learning for Imbalanced Image Classification
The data imbalance issue is critical in image classification. Contrastive learning (CL) is a predominant technique in image classification, but they showed limited classification performance when the class distribution in a training dataset is skewed (i.e., an imbalanced dataset). Recently, several supervised CL methods have been proposed particularly to promote an ideal regular simplex geometric configuration in the representation space—characterized by intra-class feature collapse and uniform inter-class mean spacing—especially for imbalanced datasets. In particular, existing prototype-based methods include class representatives, i.e., prototypes, as additional samples to achieve a more balanced treatment of all classes. However, the existing supervised CL methods for imbalanced datasets still suffer from two major limitations. First, they do not consider the alignment between the class means/prototypes and linear classifiers, which could lead to poor generalization. Second, existing prototype-based methods treat class prototypes as only one additional sample per class, making their influence depend on the number of class instances in a batch and causing unbalanced contributions across classes. To address these limitations, we propose Equilibrium Contrastive Learning (ECL), a supervised CL framework designed to promote geometric equilibrium in the representation space, where class features, means, and classifiers are harmoniously balanced under data imbalance. The proposed ECL framework uses two main strategies. First, ECL promotes the representation geometric equilibrium (i.e., a regular simplex geometry characterized by collapsed class samples and uniformly distributed class means), while balancing the contributions of class-average features and class prototypes. Second, ECL establishes a classifier-class center geometric equilibrium by aligning classifier weights and class prototypes in the representation space. We ran experiments with three long-tailed natural image datasets, the CIFAR-10-LT, CIFAR-100-LT and ImageNet-LT benchmark datasets, and the two imbalanced medical image classification datasets, the ISIC 2019 benchmark and our constructed lung cancer chest computed tomography dataset. Results with the five imbalanced datasets show that ECL outperforms existing state-of-the-art supervised CL methods designed for imbalanced/long-tailed classification. Codes are available at this link.
- Open Access
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (7) , 610-620
Agentic Artificial Intelligence for the Automated Generation of Accurate Summary Podcasts of Radiology Research Papers
To evaluate whether a custom agentic artificial intelligence (AI) pipeline can overcome the limitations of general-purpose large language model tools, when compared with a generic commercial tool (Google NotebookLM [NBLM]), for generating podcast-style summaries of radiology research articles. Twenty-two PDF-format original research articles published in the April 2025 issue of Radiology were processed using our Programmable, Phoneme-Aware PDF-to-Podcast Pipeline (P5) and NBLM to generate 44 audio episodes. P5 utilizes a multi-agent workflow for script generation, quality assurance, pronunciation enhancement, and audio synthesis. Four radiologists from a pool of 25 (7 generalists and 18 specialists) were randomly assigned to evaluate each blinded audio episode, yielding 176 total evaluations. The primary outcomes were the number of hallucinations (factual errors) per episode and the percentage of hallucination-free episodes. Secondary outcomes included the number of inappropriate statements, mispronunciations, and flow disruptions; the composite quality score (Quality Assessment of Educational Podcasts [QAEP]); the key results coverage score; and overall listener preference. Data were analyzed using generalized linear mixed models. The P5 method produced significantly fewer hallucinations per episode compared with NBLM (mean, 0.32 vs. 0.93; P < 0.001) and a higher proportion of hallucination-free episodes (71.6% [63/88] vs. 56.8% [50/88]; P = 0.013), consistently across generalists and specialists. P5 demonstrated significantly fewer mispronunciations (mean, 0.11 vs. 1.62; P < 0.001) and flow disruptions (mean, 0.19 vs. 1.06; P < 0.001) per episode, as well as higher mean QAEP composite scores (4.62 vs. 4.28; P < 0.001), compared with NBLM, consistently across generalists and specialists. Raters preferred P5 over NBLM in 72.7% (64/88) of comparisons (P = 0.003). Our custom agentic AI pipeline generated podcast-style summaries of radiology research articles with significantly higher quality and greater listener preference than the generic commercial tool.
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (7) , 610-620
Open AccessAgentic Artificial Intelligence for the Automated Generation of Accurate Summary Podcasts of Radiology Research Papers
To evaluate whether a custom agentic artificial intelligence (AI) pipeline can overcome the limitations of general-purpose large language model tools, when compared with a generic commercial tool (Google NotebookLM [NBLM]), for generating podcast-style summaries of radiology research articles. Twenty-two PDF-format original research articles published in the April 2025 issue of Radiology were processed using our Programmable, Phoneme-Aware PDF-to-Podcast Pipeline (P5) and NBLM to generate 44 audio episodes. P5 utilizes a multi-agent workflow for script generation, quality assurance, pronunciation enhancement, and audio synthesis. Four radiologists from a pool of 25 (7 generalists and 18 specialists) were randomly assigned to evaluate each blinded audio episode, yielding 176 total evaluations. The primary outcomes were the number of hallucinations (factual errors) per episode and the percentage of hallucination-free episodes. Secondary outcomes included the number of inappropriate statements, mispronunciations, and flow disruptions; the composite quality score (Quality Assessment of Educational Podcasts [QAEP]); the key results coverage score; and overall listener preference. Data were analyzed using generalized linear mixed models. The P5 method produced significantly fewer hallucinations per episode compared with NBLM (mean, 0.32 vs. 0.93; P < 0.001) and a higher proportion of hallucination-free episodes (71.6% [63/88] vs. 56.8% [50/88]; P = 0.013), consistently across generalists and specialists. P5 demonstrated significantly fewer mispronunciations (mean, 0.11 vs. 1.62; P < 0.001) and flow disruptions (mean, 0.19 vs. 1.06; P < 0.001) per episode, as well as higher mean QAEP composite scores (4.62 vs. 4.28; P < 0.001), compared with NBLM, consistently across generalists and specialists. Raters preferred P5 over NBLM in 72.7% (64/88) of comparisons (P = 0.003). Our custom agentic AI pipeline generated podcast-style summaries of radiology research articles with significantly higher quality and greater listener preference than the generic commercial tool.
- Open Access
- 15 January 2025
- Published by Korean Cancer Association in Cancer Research and Treatment
- Vol. 57 (1) , 57-69
Enhancing Identification of High-Risk cN0 Lung Adenocarcinoma Patients Using MRI-Based Radiomic Features
Purpose This study aimed to develop a magnetic resonance imaging (MRI)–based radiomics model to predict high-risk pathologic features for lung adenocarcinoma: micropapillary and solid pattern (MPsol), spread through air space, and poorly differentiated patterns.Materials and Methods As a prospective study, we screened clinical N0 lung cancer patients who were surgical candidates and had undergone both 18F-fluorodeoxyglucose (FDG) positron emission tomography–computed tomography (PET/CT) and chest CT from August 2018 to January 2020. We recruited patients meeting our proposed imaging criteria indicating high-risk, that is, poorer prognosis of lung adenocarcinoma, using CT and FDG PET/CT. If possible, these patients underwent an MRI examination from which we extracted 77 radiomics features from T1-contrast-enhanced and T2-weighted images. Additionally, patient demographics, maximum standardized uptake value on FDG PET/CT, and the mean apparent diffusion coefficient value on diffusion-weighted image, were considered together to build prediction models for high-risk pathologic features.Results Among 616 patients, 72 patients met the imaging criteria for high-risk lung cancer and underwent lung MRI. The magnetic resonance (MR)–eligible group showed a higher prevalence of nodal upstaging (29.2% vs. 4.2%, p < 0.001), vascular invasion (6.5% vs. 2.1%, p=0.011), high-grade pathologic features (p < 0.001), worse 4-year disease-free survival (p < 0.001) compared with non-MR-eligible group. The prediction power for MR-based radiomics model predicting high-risk pathologic features was good, with mean area under the receiver operating curve (AUC) value measuring 0.751-0.886 in test sets. Adding clinical variables increased the predictive performance for MPsol and the poorly differentiated pattern using the 2021 grading system (AUC, 0.860 and 0.907, respectively).Conclusion Our imaging criteria can effectively screen high-risk lung cancer patients and predict high-risk pathologic features by our MR-based prediction model using radiomics.
- 15 January 2025
- Published by Korean Cancer Association in Cancer Research and Treatment
- Vol. 57 (1) , 57-69
Open AccessEnhancing Identification of High-Risk cN0 Lung Adenocarcinoma Patients Using MRI-Based Radiomic Features
Purpose This study aimed to develop a magnetic resonance imaging (MRI)–based radiomics model to predict high-risk pathologic features for lung adenocarcinoma: micropapillary and solid pattern (MPsol), spread through air space, and poorly differentiated patterns.Materials and Methods As a prospective study, we screened clinical N0 lung cancer patients who were surgical candidates and had undergone both 18F-fluorodeoxyglucose (FDG) positron emission tomography–computed tomography (PET/CT) and chest CT from August 2018 to January 2020. We recruited patients meeting our proposed imaging criteria indicating high-risk, that is, poorer prognosis of lung adenocarcinoma, using CT and FDG PET/CT. If possible, these patients underwent an MRI examination from which we extracted 77 radiomics features from T1-contrast-enhanced and T2-weighted images. Additionally, patient demographics, maximum standardized uptake value on FDG PET/CT, and the mean apparent diffusion coefficient value on diffusion-weighted image, were considered together to build prediction models for high-risk pathologic features.Results Among 616 patients, 72 patients met the imaging criteria for high-risk lung cancer and underwent lung MRI. The magnetic resonance (MR)–eligible group showed a higher prevalence of nodal upstaging (29.2% vs. 4.2%, p < 0.001), vascular invasion (6.5% vs. 2.1%, p=0.011), high-grade pathologic features (p < 0.001), worse 4-year disease-free survival (p < 0.001) compared with non-MR-eligible group. The prediction power for MR-based radiomics model predicting high-risk pathologic features was good, with mean area under the receiver operating curve (AUC) value measuring 0.751-0.886 in test sets. Adding clinical variables increased the predictive performance for MPsol and the poorly differentiated pattern using the 2021 grading system (AUC, 0.860 and 0.907, respectively).Conclusion Our imaging criteria can effectively screen high-risk lung cancer patients and predict high-risk pathologic features by our MR-based prediction model using radiomics.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (3) , e230094
AI-assisted Analysis to Facilitate Detection of Humeral Lesions on Chest Radiographs
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop an artificial intelligence (AI) system for humeral tumor detection on chest radiographs (CRs) and evaluate the impact on reader performance. Materials and Methods In this retrospective study, 14,709 CRs (January 2000-December 2021) were collected from 13,468 patients, including CT-proven normal (n = 13,116) and humeral tumor (n = 1,593) cases. The data were divided into training and test groups. A novel training method called false-positive activation area reduction (FPAR) was introduced to enhance the diagnostic performance by focusing on the humeral region. The AI program and ten radiologists were assessed using holdout test set 1, wherein the radiologists were tested twice (with and without AI test results). The performance of the AI system was evaluated using holdout test set 2, comprising 10,497 normal images. Receiver operating characteristic (ROC) analyses were conducted for evaluating model performance. Results FPAR application in the AI program improved its performance compared with a conventional model based on the area under the receiver operating characteristic curve (0.87 versus 0.82, P = 0.04). The proposed AI system also demonstrated improved tumor localization accuracy (80% versus 57%, P < .001). In holdout test set 2, the proposed AI system exhibited a false positive rate of 2%. AI assistance improved the radiologists' sensitivity, specificity, and accuracy by 8.9%, 1.2%, and 3.5%, respectively (P < .05 for all). Conclusion The proposed AI tool incorporating FPAR improved humeral tumor detection on CRs and reduced false positives in tumor visualization. It may serve as a supportive diagnostic tool to alert radiologists about humeral abnormalities. ©RSNA, 2024.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (3) , e230094
AI-assisted Analysis to Facilitate Detection of Humeral Lesions on Chest Radiographs
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop an artificial intelligence (AI) system for humeral tumor detection on chest radiographs (CRs) and evaluate the impact on reader performance. Materials and Methods In this retrospective study, 14,709 CRs (January 2000-December 2021) were collected from 13,468 patients, including CT-proven normal (n = 13,116) and humeral tumor (n = 1,593) cases. The data were divided into training and test groups. A novel training method called false-positive activation area reduction (FPAR) was introduced to enhance the diagnostic performance by focusing on the humeral region. The AI program and ten radiologists were assessed using holdout test set 1, wherein the radiologists were tested twice (with and without AI test results). The performance of the AI system was evaluated using holdout test set 2, comprising 10,497 normal images. Receiver operating characteristic (ROC) analyses were conducted for evaluating model performance. Results FPAR application in the AI program improved its performance compared with a conventional model based on the area under the receiver operating characteristic curve (0.87 versus 0.82, P = 0.04). The proposed AI system also demonstrated improved tumor localization accuracy (80% versus 57%, P < .001). In holdout test set 2, the proposed AI system exhibited a false positive rate of 2%. AI assistance improved the radiologists' sensitivity, specificity, and accuracy by 8.9%, 1.2%, and 3.5%, respectively (P < .05 for all). Conclusion The proposed AI tool incorporating FPAR improved humeral tumor detection on CRs and reduced false positives in tumor visualization. It may serve as a supportive diagnostic tool to alert radiologists about humeral abnormalities. ©RSNA, 2024.
- Open Access
- 14 October 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (41) , e31095
Accuracy and reproducibility of shear wave elastography according to the size and elasticity of lesions: A phantom study
While the extrinsic factors affecting reproducibility of shear wave elastography (SWE) have been well documented, there are few resources assessing intrinsic characteristics of the lesion affecting the reproducibility and accuracy of SWE. In this regard, this study aimed to evaluate the accuracy of measured elasticity and the reproducibility of SWE according to the lesion size and stiffness. Two breast radiologists examined 20 targets of 4 different levels of stiffness and 5 different sizes (2.5, 4, 7, 11, and 18 mm) in a customized elasticity phantom. The B-mode image, color elastography image, and kPa measurement were obtained twice by each examiner with a 1-week interval. Inter- and intra-observer reproducibility and the accuracy of measured kPa were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Subgroup analysis was run to evaluate the effect of lesion size and stiffness on the reproducibility and accuracy of measured kPa. Inter- and intraobserver reproducibility for measuring kPa showed excellent agreement (ICC: 0.9742 and 0.9582; ICC: 0.9932 and 0.9294). The size and stiffness of the targets did not affect reproducibility. The overall accuracy of measured kPa was very high (ICC: 0.8049). In the subgroup analysis, targets that were ≤4 mm in size showed lower accuracy (ICC: 0.542), whereas targets that were 7 and 11 mm in size showed higher accuracy (ICC: 0.9832 and 0.9656, respectively). SWE shows excellent reproducibility regardless of lesion size or stiffness in phantom targets. The accuracy of measured kPa is high in lesions that are 7 and 11 mm in size but is low in lesions that are ≤4 mm in size.
- 14 October 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (41) , e31095
Open AccessAccuracy and reproducibility of shear wave elastography according to the size and elasticity of lesions: A phantom study
While the extrinsic factors affecting reproducibility of shear wave elastography (SWE) have been well documented, there are few resources assessing intrinsic characteristics of the lesion affecting the reproducibility and accuracy of SWE. In this regard, this study aimed to evaluate the accuracy of measured elasticity and the reproducibility of SWE according to the lesion size and stiffness. Two breast radiologists examined 20 targets of 4 different levels of stiffness and 5 different sizes (2.5, 4, 7, 11, and 18 mm) in a customized elasticity phantom. The B-mode image, color elastography image, and kPa measurement were obtained twice by each examiner with a 1-week interval. Inter- and intra-observer reproducibility and the accuracy of measured kPa were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Subgroup analysis was run to evaluate the effect of lesion size and stiffness on the reproducibility and accuracy of measured kPa. Inter- and intraobserver reproducibility for measuring kPa showed excellent agreement (ICC: 0.9742 and 0.9582; ICC: 0.9932 and 0.9294). The size and stiffness of the targets did not affect reproducibility. The overall accuracy of measured kPa was very high (ICC: 0.8049). In the subgroup analysis, targets that were ≤4 mm in size showed lower accuracy (ICC: 0.542), whereas targets that were 7 and 11 mm in size showed higher accuracy (ICC: 0.9832 and 0.9656, respectively). SWE shows excellent reproducibility regardless of lesion size or stiffness in phantom targets. The accuracy of measured kPa is high in lesions that are 7 and 11 mm in size but is low in lesions that are ≤4 mm in size.
- Open Access
- 18 July 2022
- Published by Korean Breast Cancer Society in Journal of Breast Cancer
- Vol. 25 (5) , 436-442
Multicentric Breast Cancer of the Axillary and Pectoral Breasts: A Case Report and Literature Review
Kim H, et al. J Breast Cancer. 2022 Jul;25:e33. https://doi.org/10.4048/jbc.2022.25.e33
- 18 July 2022
- Published by Korean Breast Cancer Society in Journal of Breast Cancer
- Vol. 25 (5) , 436-442
Open AccessMulticentric Breast Cancer of the Axillary and Pectoral Breasts: A Case Report and Literature Review
Kim H, et al. J Breast Cancer. 2022 Jul;25:e33. https://doi.org/10.4048/jbc.2022.25.e33
- Open Access
- 30 December 2021
- Published by Wiley in Thoracic Cancer
- Vol. 13 (4) , 643-647
The rarest of rare cases within the one thousand faces of atypical carcinoid: Pseudomesotheliomatous manifestation in a pregnant woman
Carcinoid tumors in pregnant women are rare, and there have been no previous studies of atypical carcinoid tumor reported in pregnancy. Also, pseudomesotheliomatous manifestation in atypical carcinoid is an extremely rare finding, there being only two cases reported. Here, we present the first case of pseudomesotheliomatous manifestation of atypical carcinoid in a pregnant woman. Upon image analysis, we found that atypical carcinoids with multiple metastatic lesions can exhibit variability in vascularity and metabolism, resulting in heterogeneous image characteristics among metastatic lesions, even those with identical histology. In addition, even with extensive metastasis, patients can exhibit good performance explained by long-standing presentation of indolent cancer.
- 30 December 2021
- Published by Wiley in Thoracic Cancer
- Vol. 13 (4) , 643-647
Open AccessThe rarest of rare cases within the one thousand faces of atypical carcinoid: Pseudomesotheliomatous manifestation in a pregnant woman
Carcinoid tumors in pregnant women are rare, and there have been no previous studies of atypical carcinoid tumor reported in pregnancy. Also, pseudomesotheliomatous manifestation in atypical carcinoid is an extremely rare finding, there being only two cases reported. Here, we present the first case of pseudomesotheliomatous manifestation of atypical carcinoid in a pregnant woman. Upon image analysis, we found that atypical carcinoids with multiple metastatic lesions can exhibit variability in vascularity and metabolism, resulting in heterogeneous image characteristics among metastatic lesions, even those with identical histology. In addition, even with extensive metastasis, patients can exhibit good performance explained by long-standing presentation of indolent cancer.