Tracie Profaizer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tracie Profaizer has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
A. Kumánovics
Department of Pathology, ARUP Institute for Clinical and Experimental Pathology, University of Utah School of Medicine, Salt Lake City, UT, USA
3 shared publicationsAttila Kumánovics
ARUP Institute for Clinical and Experimental Pathology, Department of Pathology, University of Utah School of Medicine, 500 Chipeta Way, Salt Lake City, UT 84108, USA
3 shared publications- Eszter Lázár-Molnár
Department of Pathology, University of Utah, Salt Lake City, UT, USA; Histocompatibility and Immunogenetics Laboratory, University of Utah Health, Salt Lake City, UT, USA
3 shared publications E. Lázár‐Molnár
Department of Pathology, ARUP Institute for Clinical and Experimental Pathology, University of Utah School of Medicine, Salt Lake City, UT, USA
2 shared publicationsJ. C. Delgado
Department of Pathology, ARUP Institute for Clinical and Experimental Pathology, University of Utah School of Medicine, Salt Lake City, UT, USA
2 shared publications- Julio C. Delgado
Department of Pathology, University of Utah , Salt Lake City, UT
2 shared publications
Latest Publications
- 24 December 2021
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (3) , 698-710
Evaluation of a Novel Multiplex Platform for Simultaneous Detection of IgG Antibodies Against the 4 Main SARS-CoV-2 Antigens
Background: Numerous serology assays are available for detection of SARS-CoV-2 antibodies but are limited in that only 1 or 2 target antigen(s) can be tested at a time. Here, we describe a novel multiplex assay that simultaneously detects and quantifies IgG antibodies to SARS-CoV-2 antigens, spike (S), nucleocapsid (N), receptor-binding domain (RBD), and N-terminal domain (NTD) in a single well. Methods: Sensitivity was determined using samples (n = 124) from confirmed SARS-CoV-2 RT-PCR positive individuals. Prepandemic (n = 100) and non-COVID respiratory infection positive samples (n = 100) were used to evaluate specificity. Samples were analyzed using COVID-19 IgG multiplex serology assay from Meso Scale Discovery (MSD) and using commercial platforms from Abbott, EUROIMMUN, and Siemens. Results: At >14 days post-PCR, MSD assay displayed >98.0% sensitivity [S 100% (95% CI 98.0%–100.0%); N 98.0% (95% CI 97.2%–98.9%); RBD 94.1% (95% CI 92.6%–95.6%); NTD 98.0% (95% CI, 97.2%–98.9%)] and 99% specificity (95% CI 99.3%–99.7%) for antibodies to all 4 antigens. Parallel assessment of antibodies to more than 1 antigen improved the sensitivity to 100% (95% CI 98.0%–100.0%) while maintaining 98% (95% CI 97.6%–98.4%) specificity regardless of the combinations used. When AU/mL concentrations of IgG antibodies from the MSD assay were compared against the corresponding IgG signals acquired from the single target commercial assays, the following correlations were observed: Abbott (vs MSD N, R2 = 0.73), Siemens (vs MSD RBD, R2 = 0.92), and EUROIMMUN (vs MSD S, R2 = 0.82). Conclusion: MSD assay offers an accurate and a comprehensive assessment of SARS-CoV-2 antibodies with higher sensitivity and equivalent specificity compared to the commercial IgG serology assays.
- 24 December 2021
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (3) , 698-710
Evaluation of a Novel Multiplex Platform for Simultaneous Detection of IgG Antibodies Against the 4 Main SARS-CoV-2 Antigens
Background: Numerous serology assays are available for detection of SARS-CoV-2 antibodies but are limited in that only 1 or 2 target antigen(s) can be tested at a time. Here, we describe a novel multiplex assay that simultaneously detects and quantifies IgG antibodies to SARS-CoV-2 antigens, spike (S), nucleocapsid (N), receptor-binding domain (RBD), and N-terminal domain (NTD) in a single well. Methods: Sensitivity was determined using samples (n = 124) from confirmed SARS-CoV-2 RT-PCR positive individuals. Prepandemic (n = 100) and non-COVID respiratory infection positive samples (n = 100) were used to evaluate specificity. Samples were analyzed using COVID-19 IgG multiplex serology assay from Meso Scale Discovery (MSD) and using commercial platforms from Abbott, EUROIMMUN, and Siemens. Results: At >14 days post-PCR, MSD assay displayed >98.0% sensitivity [S 100% (95% CI 98.0%–100.0%); N 98.0% (95% CI 97.2%–98.9%); RBD 94.1% (95% CI 92.6%–95.6%); NTD 98.0% (95% CI, 97.2%–98.9%)] and 99% specificity (95% CI 99.3%–99.7%) for antibodies to all 4 antigens. Parallel assessment of antibodies to more than 1 antigen improved the sensitivity to 100% (95% CI 98.0%–100.0%) while maintaining 98% (95% CI 97.6%–98.4%) specificity regardless of the combinations used. When AU/mL concentrations of IgG antibodies from the MSD assay were compared against the corresponding IgG signals acquired from the single target commercial assays, the following correlations were observed: Abbott (vs MSD N, R2 = 0.73), Siemens (vs MSD RBD, R2 = 0.92), and EUROIMMUN (vs MSD S, R2 = 0.82). Conclusion: MSD assay offers an accurate and a comprehensive assessment of SARS-CoV-2 antibodies with higher sensitivity and equivalent specificity compared to the commercial IgG serology assays.
- 1 July 2020
- Published by Elsevier in Human Immunology
- Vol. 81 (7) , 354-360
Clinical utility of next generation sequencing based HLA typing for disease association and pharmacogenetic testing
- 1 July 2020
- Published by Elsevier in Human Immunology
- Vol. 81 (7) , 354-360
Clinical utility of next generation sequencing based HLA typing for disease association and pharmacogenetic testing
- 30 December 2019
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 66 (1) , 229-238
A Multiplex, Droplet Digital PCR Assay for the Detection of T-Cell Receptor Excision Circles and Kappa-Deleting Recombination Excision Circles
Background: T-cell receptor excision circles (TREC) and κ-deleting recombination receptor excision circles (KREC) concentrations can be used to assess and diagnose immune deficiencies, monitor thymic and bone marrow immune reconstitution, or follow responses to drug therapy. We developed an assay to quantify TREC, KREC, and a reference gene in a single reaction using droplet digital PCR (ddPCR). Methods: PCR was optimized for 3 targets: TREC, KREC, and ribonuclease P/MRP subunit p30 (RPP30) as the reference gene. Multiplexing was accomplished by varying the target’s fluorophore and concentration. Correlation with clinical results was evaluated using 47 samples from healthy donors, 59 samples with T-cell and B-cell markers within the reference interval from the flow cytometry laboratory, 20 cord blood samples, and 34 samples submitted for exome sequencing for severe combined immunodeficiency disease (SCID). Results: The limit of the blank was 4 positive droplets, limit of detection 9 positive droplets, and limit of quantification 25 positive droplets, or 2.0 copies/μ L. TREC and KREC copies/μ L were as expected in the healthy donors and cord blood samples and concordant with the healthy flow cytometry results. Of the samples from the SCID Panel, 56.5% had a TREC count <20 copies/μ L and 17.7% had a KREC count <20 copies/μ L, suggestive of low T- and B-cell numbers, respectively. Conclusions: Our multiplex ddPCR assay is an analytically sensitive and specific method for the absolute quantification of TREC and KREC. To the best of our knowledge, this paper is the first to describe the simultaneous quantification of TREC, KREC, and a reference gene by use of ddPCR.
- 30 December 2019
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 66 (1) , 229-238
A Multiplex, Droplet Digital PCR Assay for the Detection of T-Cell Receptor Excision Circles and Kappa-Deleting Recombination Excision Circles
Background: T-cell receptor excision circles (TREC) and κ-deleting recombination receptor excision circles (KREC) concentrations can be used to assess and diagnose immune deficiencies, monitor thymic and bone marrow immune reconstitution, or follow responses to drug therapy. We developed an assay to quantify TREC, KREC, and a reference gene in a single reaction using droplet digital PCR (ddPCR). Methods: PCR was optimized for 3 targets: TREC, KREC, and ribonuclease P/MRP subunit p30 (RPP30) as the reference gene. Multiplexing was accomplished by varying the target’s fluorophore and concentration. Correlation with clinical results was evaluated using 47 samples from healthy donors, 59 samples with T-cell and B-cell markers within the reference interval from the flow cytometry laboratory, 20 cord blood samples, and 34 samples submitted for exome sequencing for severe combined immunodeficiency disease (SCID). Results: The limit of the blank was 4 positive droplets, limit of detection 9 positive droplets, and limit of quantification 25 positive droplets, or 2.0 copies/μ L. TREC and KREC copies/μ L were as expected in the healthy donors and cord blood samples and concordant with the healthy flow cytometry results. Of the samples from the SCID Panel, 56.5% had a TREC count <20 copies/μ L and 17.7% had a KREC count <20 copies/μ L, suggestive of low T- and B-cell numbers, respectively. Conclusions: Our multiplex ddPCR assay is an analytically sensitive and specific method for the absolute quantification of TREC and KREC. To the best of our knowledge, this paper is the first to describe the simultaneous quantification of TREC, KREC, and a reference gene by use of ddPCR.
- 1 December 2018
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 38 (4) , 565-578
Human Leukocyte Antigen Typing by Next-Generation Sequencing
- 1 December 2018
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 38 (4) , 565-578
Human Leukocyte Antigen Typing by Next-Generation Sequencing
- 28 May 2017
- Published by Wiley in International Journal of Immunogenetics
- Vol. 44 (4) , 164-168
HLA genotyping using the Illumina HLA TruSight next‐generation sequencing kits: A comparison
Summary: Illumina first introduced their TruSight human leucocyte antigen (HLA) next‐generation sequencing (NGS) typing kit in 2015 and subsequently followed up with a new version in 2016. Here we report on our experience comparing the two versions of the Illumina HLA NGS kits.
- 28 May 2017
- Published by Wiley in International Journal of Immunogenetics
- Vol. 44 (4) , 164-168
HLA genotyping using the Illumina HLA TruSight next‐generation sequencing kits: A comparison
Summary: Illumina first introduced their TruSight human leucocyte antigen (HLA) next‐generation sequencing (NGS) typing kit in 2015 and subsequently followed up with a new version in 2016. Here we report on our experience comparing the two versions of the Illumina HLA NGS kits.
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 105
P091 Comparison of four HLA next-generation sequencing typing methods
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 105
P091 Comparison of four HLA next-generation sequencing typing methods
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 94
P079 Experience using the illumina HLA trusight NGS kits: Version 1 vs. version 2
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 94
P079 Experience using the illumina HLA trusight NGS kits: Version 1 vs. version 2
HLA genotyping in the clinical laboratory: comparison of next‐generation sequencing methods
Implementation of human leukocyte antigen (HLA) genotyping by next‐generation sequencing (NGS) in the clinical lab brings new challenges to the laboratories performing this testing. With the advent of commercially available HLA‐NGS typing kits, labs must make numerous decisions concerning capital equipment and address labor considerations. Therefore, careful and unbiased evaluation of available methods is imperative. In this report, we compared our in‐house developed HLA NGS typing with two commercially available kits from Illumina and Omixon using 10 International Histocompatibility Working Group (IHWG) and 36 clinical samples. Although all three methods employ long range polymerase chain reaction (PCR) and have been developed on the Illumina MiSeq platform, the methodologies for library preparation show significant variations. There was 100% typing concordance between all three methods at the first field when a HLA type could be assigned. Overall, HLA typing by NGS using in‐house or commercially available methods is now feasible in clinical laboratories. However, technical variables such as hands‐on time and indexing strategies are sufficiently different among these approaches to impact the workflow of the clinical laboratory.
HLA genotyping in the clinical laboratory: comparison of next‐generation sequencing methods
Implementation of human leukocyte antigen (HLA) genotyping by next‐generation sequencing (NGS) in the clinical lab brings new challenges to the laboratories performing this testing. With the advent of commercially available HLA‐NGS typing kits, labs must make numerous decisions concerning capital equipment and address labor considerations. Therefore, careful and unbiased evaluation of available methods is imperative. In this report, we compared our in‐house developed HLA NGS typing with two commercially available kits from Illumina and Omixon using 10 International Histocompatibility Working Group (IHWG) and 36 clinical samples. Although all three methods employ long range polymerase chain reaction (PCR) and have been developed on the Illumina MiSeq platform, the methodologies for library preparation show significant variations. There was 100% typing concordance between all three methods at the first field when a HLA type could be assigned. Overall, HLA typing by NGS using in‐house or commercially available methods is now feasible in clinical laboratories. However, technical variables such as hands‐on time and indexing strategies are sufficiently different among these approaches to impact the workflow of the clinical laboratory.
- 1 December 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (12) , 897-902
Report on the effects of fragment size, indexing, and read length on HLA sequencing on the Illumina MiSeq
- 1 December 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (12) , 897-902
Report on the effects of fragment size, indexing, and read length on HLA sequencing on the Illumina MiSeq
- 1 October 2014
- Published by Elsevier in Human Immunology
- Vol. 75, 118
P096