Andrei S. Shulgin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrei S. Shulgin has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Dmitry Dmitrievich Shkarupa
Saint Petersburg State University
17 shared publications - Nikita Dmitrievich Kubin
Saint Petersburg State University
15 shared publications - Rustam Shakhaliev
Saint Petersburg State University
13 shared publications - Denis A. Suchkov
Saint Petersburg State University
7 shared publications - Ivan Antonovich Labetov
Pirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State University
7 shared publications - Gleb Valerevich Kovalev
Saint Petersburg State University
4 shared publications
Latest Publications
- 9 July 2026
- Published by Rostov State Medical University in Urology Herald
- Vol. 14 (2)
Complications associated with suburethral sling implantation: a comprehensive analysis
Introduction . Stress urinary incontinence is widely prevalent among women, and the use of mid-urethral slings (MUS) is associated with a risk of complications, which necessitates clarification of their causes and consequences for quality of life. Objective . To perform a comprehensive analysis of complications associated with synthetic MUS implantation, identifying the structure of complications, contributing factors, and their impact on quality of life. Materials & methods . A retrospective study was conducted on 148 female patients who underwent surgical sling removal due to complications between 2022 and 2024. Clinical characteristics, concomitant procedures, urodynamic data, and results from standardized questionnaires (UDI-6, ICIQ-SF, PISQ-12) and the Visual Analog Scale for pain (VAS) were analyzed. Results. The most common complications were chronic pain syndrome (29.1%), obstructive voiding (26.4%), and mesh extrusion (16.2%). A combination of two or more complications was identified in 68% of patients, most commonly pain combined with obstruction (21.6%). Incorrect sling positioning was detected in 17.5% of women. Among patients operated on by surgeons with less than 5 years of experience, the frequency of obstruction and pain was 2.3 times higher (p = 0.03). Concomitant sling implantation during pelvic organ prolapse repair was found to be associated with a higher risk of complications (p = 0.037). Conservative treatment administered before explantation proved ineffective in most cases. The time to detection of complications ranged from 3 months to 1.5 years, with some erosions being asymptomatic and diagnosed incidentally. Conclusions . The study results demonstrate the multifactorial nature of complications after MUS implantation. Significant risk factors were identified, including suboptimal implant positioning, limited surgeon experience, and concomitant procedures. The findings emphasize the need for careful preoperative planning, adherence to surgical technique, and long-term postoperative follow-up.
- 9 July 2026
- Published by Rostov State Medical University in Urology Herald
- Vol. 14 (2)
Complications associated with suburethral sling implantation: a comprehensive analysis
Introduction . Stress urinary incontinence is widely prevalent among women, and the use of mid-urethral slings (MUS) is associated with a risk of complications, which necessitates clarification of their causes and consequences for quality of life. Objective . To perform a comprehensive analysis of complications associated with synthetic MUS implantation, identifying the structure of complications, contributing factors, and their impact on quality of life. Materials & methods . A retrospective study was conducted on 148 female patients who underwent surgical sling removal due to complications between 2022 and 2024. Clinical characteristics, concomitant procedures, urodynamic data, and results from standardized questionnaires (UDI-6, ICIQ-SF, PISQ-12) and the Visual Analog Scale for pain (VAS) were analyzed. Results. The most common complications were chronic pain syndrome (29.1%), obstructive voiding (26.4%), and mesh extrusion (16.2%). A combination of two or more complications was identified in 68% of patients, most commonly pain combined with obstruction (21.6%). Incorrect sling positioning was detected in 17.5% of women. Among patients operated on by surgeons with less than 5 years of experience, the frequency of obstruction and pain was 2.3 times higher (p = 0.03). Concomitant sling implantation during pelvic organ prolapse repair was found to be associated with a higher risk of complications (p = 0.037). Conservative treatment administered before explantation proved ineffective in most cases. The time to detection of complications ranged from 3 months to 1.5 years, with some erosions being asymptomatic and diagnosed incidentally. Conclusions . The study results demonstrate the multifactorial nature of complications after MUS implantation. Significant risk factors were identified, including suboptimal implant positioning, limited surgeon experience, and concomitant procedures. The findings emphasize the need for careful preoperative planning, adherence to surgical technique, and long-term postoperative follow-up.
- 25 December 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (4)
Development of a classification of slings used in the surgical treatment of stress urinary incontinence in men.
Introduction. Stress urinary incontinence (SUI) in men, primarily post-prostatectomy, remains a common and socially significant complication. Among surgical treatment options, alongside the artificial urinary sphincter, various sling systems are widely used. However, there is currently no unified classification of these implants in the literature, which complicates their comparative analysis, the choice of optimal tactics, and the development of new devices. Aim. To develop a comprehensive classification of male slings used for the surgical treatment of stress urinary incontinence (Comprehensive Male Sling Classification, CMSC) based on the systematization of their key design and functional parameters. Materials and methods. To create the classification, a systematic analysis of data from the most relevant publications found in PubMed, Google Scholar, and the Russian Science Citation Index (RSCI) databases was conducted using keywords related to male slings and post-prostatectomy incontinence. The selection criterion was the completeness of the description of sling parameters suitable for classification. Results. An original CMSC classification is proposed, based on six key parameters combined into the mnemonic formula «A_MAP_oF_sLing»: Adjustability, Material, Approach, Principle of action, Fixation, Location. Based on this classification, the main slings used in clinical practice (InVance®, UroSling® male, REMEEX®, Argus®, AdVance®/XP, A.M.I.® ATOMS, I-STOP TOMS®, Virtue® quadratic) were analyzed and categorized. For each of them, a detailed characterization according to CMSC is provided, including design, mechanism of action, advantages, disadvantages, and efficacy data. The systematization results are presented in a summary table. Conclusions. The proposed CMSC classification is a universal and logically structured tool for systematizing existing and future male sling systems. It allows for the standardization of implant descriptions, facilitates their comparison and selection for specific clinical cases, and forms a basis for further research in the field of surgical treatment of male stress urinary incontinence.
- 25 December 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (4)
Development of a classification of slings used in the surgical treatment of stress urinary incontinence in men.
Introduction. Stress urinary incontinence (SUI) in men, primarily post-prostatectomy, remains a common and socially significant complication. Among surgical treatment options, alongside the artificial urinary sphincter, various sling systems are widely used. However, there is currently no unified classification of these implants in the literature, which complicates their comparative analysis, the choice of optimal tactics, and the development of new devices. Aim. To develop a comprehensive classification of male slings used for the surgical treatment of stress urinary incontinence (Comprehensive Male Sling Classification, CMSC) based on the systematization of their key design and functional parameters. Materials and methods. To create the classification, a systematic analysis of data from the most relevant publications found in PubMed, Google Scholar, and the Russian Science Citation Index (RSCI) databases was conducted using keywords related to male slings and post-prostatectomy incontinence. The selection criterion was the completeness of the description of sling parameters suitable for classification. Results. An original CMSC classification is proposed, based on six key parameters combined into the mnemonic formula «A_MAP_oF_sLing»: Adjustability, Material, Approach, Principle of action, Fixation, Location. Based on this classification, the main slings used in clinical practice (InVance®, UroSling® male, REMEEX®, Argus®, AdVance®/XP, A.M.I.® ATOMS, I-STOP TOMS®, Virtue® quadratic) were analyzed and categorized. For each of them, a detailed characterization according to CMSC is provided, including design, mechanism of action, advantages, disadvantages, and efficacy data. The systematization results are presented in a summary table. Conclusions. The proposed CMSC classification is a universal and logically structured tool for systematizing existing and future male sling systems. It allows for the standardization of implant descriptions, facilitates their comparison and selection for specific clinical cases, and forms a basis for further research in the field of surgical treatment of male stress urinary incontinence.
- Open Access
- 30 July 2025
- Published by Rostov State Medical University in Urology Herald
- Vol. 13 (3) , 159-164
Urethrovaginal fistula: is fistuloplasty always indicated?
Introduction. A urethrovaginal fistula is a type of genitourinary fistula characterised by an abnormal communication between the urethra and the vagina. The principal clinical features include urinary leakage through the vagina, partial or complete stress urinary incontinence (SUI) precipitated by coughing, sneezing, or physical exertion, as well as dysuria and spraying of the urinary stream.Objective. We present a clinical case demonstrating the possibility of addressing the patient’s primary complaint through the placement of an adjustable suburethral sling (SUS) without closure of the urethral fistula.Case presentation. A 44-year-old female patient was diagnosed with SUI, urethrovaginal fistula, and meatal obliteration. At the time of examination, she reported significant urinary leakage during coughing, sneezing, and physical exertion, altered urinary stream direction, and urine leakage from the vagina following micturition. The symptoms first appeared in 2005 postpartum, complicated by urethral prolapse with subsequent excision of the necrotic distal segment. On examination, the external urethral meatus was obliterated. A fistulous opening was observed 15 mm proximal to the obliterated urethral meatus. The urethral length measured 25 mm. The cough stress test was positive. Quality of life questionnaire scores were as follows: POPDI-6 — 8.33, CRADI-8 — 25, UDI-6 — 50, PFDI-20 — 83.33; PISQ-12 — 23; ICIQ-SF — 10. The patient underwent implantation of an adjustable SUS. Postoperatively, sling tension was adjusted. At 12-month follow-up, the cough stress test was negative. Voiding was unobstructed with no residual urine. A significant improvement in quality of life was noted according to questionnaire scores: POPDI-6 — 5, CRADI-8 — 0, UDI-6 — 4, PISQ-12 — 38, ICIQ-SF — 2.Conclusion. This clinical case demonstrates the successful use of an adjustable SUS to address the primary complaint of SUI in a patient with a urethrovaginal fistula.
- 30 July 2025
- Published by Rostov State Medical University in Urology Herald
- Vol. 13 (3) , 159-164
Open AccessUrethrovaginal fistula: is fistuloplasty always indicated?
Introduction. A urethrovaginal fistula is a type of genitourinary fistula characterised by an abnormal communication between the urethra and the vagina. The principal clinical features include urinary leakage through the vagina, partial or complete stress urinary incontinence (SUI) precipitated by coughing, sneezing, or physical exertion, as well as dysuria and spraying of the urinary stream.Objective. We present a clinical case demonstrating the possibility of addressing the patient’s primary complaint through the placement of an adjustable suburethral sling (SUS) without closure of the urethral fistula.Case presentation. A 44-year-old female patient was diagnosed with SUI, urethrovaginal fistula, and meatal obliteration. At the time of examination, she reported significant urinary leakage during coughing, sneezing, and physical exertion, altered urinary stream direction, and urine leakage from the vagina following micturition. The symptoms first appeared in 2005 postpartum, complicated by urethral prolapse with subsequent excision of the necrotic distal segment. On examination, the external urethral meatus was obliterated. A fistulous opening was observed 15 mm proximal to the obliterated urethral meatus. The urethral length measured 25 mm. The cough stress test was positive. Quality of life questionnaire scores were as follows: POPDI-6 — 8.33, CRADI-8 — 25, UDI-6 — 50, PFDI-20 — 83.33; PISQ-12 — 23; ICIQ-SF — 10. The patient underwent implantation of an adjustable SUS. Postoperatively, sling tension was adjusted. At 12-month follow-up, the cough stress test was negative. Voiding was unobstructed with no residual urine. A significant improvement in quality of life was noted according to questionnaire scores: POPDI-6 — 5, CRADI-8 — 0, UDI-6 — 4, PISQ-12 — 38, ICIQ-SF — 2.Conclusion. This clinical case demonstrates the successful use of an adjustable SUS to address the primary complaint of SUI in a patient with a urethrovaginal fistula.
- Open Access
- 25 June 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (2)
Clinical study of a new generation partially absorbable synthetic implant (ligature delivery system) for the correction of apical pelvic organs prolapse.
Introduction. Pelvic organ prolapse (POP) is a common condition that significantly impairs women's quality of life. Despite the effectiveness of synthetic implants, their use is limited due to the high risk of complications. In recent years, partially absorbable suture delivery systems have been actively developed to reduce implant-associated complications. Objective. To evaluate the clinical efficacy and safety of unilateral hybrid pelvic floor reconstruction using a partially absorbable suture delivery system. Materials and Methods. The study included 30 patients with stage 2–4 apical POP (POP-Q classification). Unilateral hybrid pelvic floor reconstruction was performed using the suture delivery system. Anatomical efficacy was assessed using the POP-Q system 12 months postoperatively. Additional assessments included quality of life (PFDI-20, ICIQ-SF) and patient satisfaction (IMPSS, PGI-I). MRI of the pelvic organs with intravenous contrast was performed in two patients. Results. At 12 months, anatomical efficacy was achieved in 96.7% of patients (p<0.001). No cases of implant erosion or chronic pelvic pain were detected. Significant improvement in quality of life was observed across all PFDI-20 subscales (p<0.001). VAS scores remained statistically unchanged. Patient satisfaction levels were high. MRI data showed the formation of a band with distinct, uniform contrast agent accumulation in the late venous phase, characteristic of scar tissue. Conclusion. Unilateral hybrid pelvic floor reconstruction using a partially absorbable suture delivery system is a safe and effective method for POP correction, significantly improving patients' quality of life.
- 25 June 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (2)
Open AccessClinical study of a new generation partially absorbable synthetic implant (ligature delivery system) for the correction of apical pelvic organs prolapse.
Introduction. Pelvic organ prolapse (POP) is a common condition that significantly impairs women's quality of life. Despite the effectiveness of synthetic implants, their use is limited due to the high risk of complications. In recent years, partially absorbable suture delivery systems have been actively developed to reduce implant-associated complications. Objective. To evaluate the clinical efficacy and safety of unilateral hybrid pelvic floor reconstruction using a partially absorbable suture delivery system. Materials and Methods. The study included 30 patients with stage 2–4 apical POP (POP-Q classification). Unilateral hybrid pelvic floor reconstruction was performed using the suture delivery system. Anatomical efficacy was assessed using the POP-Q system 12 months postoperatively. Additional assessments included quality of life (PFDI-20, ICIQ-SF) and patient satisfaction (IMPSS, PGI-I). MRI of the pelvic organs with intravenous contrast was performed in two patients. Results. At 12 months, anatomical efficacy was achieved in 96.7% of patients (p<0.001). No cases of implant erosion or chronic pelvic pain were detected. Significant improvement in quality of life was observed across all PFDI-20 subscales (p<0.001). VAS scores remained statistically unchanged. Patient satisfaction levels were high. MRI data showed the formation of a band with distinct, uniform contrast agent accumulation in the late venous phase, characteristic of scar tissue. Conclusion. Unilateral hybrid pelvic floor reconstruction using a partially absorbable suture delivery system is a safe and effective method for POP correction, significantly improving patients' quality of life.
- Open Access
- 17 June 2025
- Published by Consilium Medicum in GYNECOLOGY
- Vol. 27 (2) , 148-152
Hybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation in the management of post-hysterectomy prolapse: A retrospective study
Aim. To evaluate the anatomical effectiveness and safety of hybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation in women with post-hysterectomy prolapse. Materials and methods. This retrospective study included 62 female patients with stage II–IV vaginal vault prolapse (according to the POP-Q classification) who underwent a novel surgical technique. The primary endpoint was anatomical success; secondary endpoints included changes in quality of life (PFDI-20, ICIQ-SF questionnaires) and patient satisfaction with treatment outcomes. Results. The mean follow-up period was 14.86 months. Anatomical success was achieved in 93.5% of cases. No cases of implant erosion or chronic pelvic pain were reported. Significant improvement in pelvic floor dysfunction symptoms was observed across all PFDI-20 subscales (p0.001). Vaginal length significantly increased postoperatively. Recurrence of prolapse occurred in 6.5% of cases and required reoperation. Two cases of intraoperative bladder injury were noted, which did not affect the final outcomes. Conclusion. Hybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation demonstrated high anatomical efficacy and safety in the correction of post-hysterectomy prolapse. However, further prospective studies with control groups and longer follow-up are needed to confirm these findings.
- 17 June 2025
- Published by Consilium Medicum in GYNECOLOGY
- Vol. 27 (2) , 148-152
Open AccessHybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation in the management of post-hysterectomy prolapse: A retrospective study
Aim. To evaluate the anatomical effectiveness and safety of hybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation in women with post-hysterectomy prolapse. Materials and methods. This retrospective study included 62 female patients with stage II–IV vaginal vault prolapse (according to the POP-Q classification) who underwent a novel surgical technique. The primary endpoint was anatomical success; secondary endpoints included changes in quality of life (PFDI-20, ICIQ-SF questionnaires) and patient satisfaction with treatment outcomes. Results. The mean follow-up period was 14.86 months. Anatomical success was achieved in 93.5% of cases. No cases of implant erosion or chronic pelvic pain were reported. Significant improvement in pelvic floor dysfunction symptoms was observed across all PFDI-20 subscales (p0.001). Vaginal length significantly increased postoperatively. Recurrence of prolapse occurred in 6.5% of cases and required reoperation. Two cases of intraoperative bladder injury were noted, which did not affect the final outcomes. Conclusion. Hybrid pelvic floor reconstruction using a vaginal flap with unilateral apical fixation demonstrated high anatomical efficacy and safety in the correction of post-hysterectomy prolapse. However, further prospective studies with control groups and longer follow-up are needed to confirm these findings.
- 1 January 2025
- Published by Dynasty Publishing House in Voprosy Ginekologii, Akušerstva i Perinatologii
- Vol. 24 (3)
Laparovaginal hybrid pelvic floor reconstruction. A single-center retrospective study
Sacrocolpopexy is the gold standard treatment for pelvic organ prolapse (POP). However, this technique involves extensive dissection of the pelvic floor structures, which has led to a modification of the standard technique. Objective. To study the efficacy and safety of combined laparovaginal hybrid pelvic floor reconstruction. Patients and methods. The study enrolled 74 patients who underwent surgical intervention. The technique included anterior and posterior colporrhaphy, perineoplasty, and simplified sacrohysteropexy. Data from the validated PFDI-20, PISQ-12 and ICIQ-SF questionnaires, analysis of prolapse stages according to the POP-Q system, and the presence of complications were used to evaluate the efficacy. Results. The mean duration of surgery was 162.2 ± 45.2 minutes. Recurrent prolapse that required repeat intervention was recorded in 5% of patients within 12–18 months of follow-up. The symptoms of de novo stress urinary incontinence (SUI) were detected in 4% of patients, and 2.7% experienced worsening of pre-existing SUI. No cases of implant erosion and dyspareunia were recorded. Patients reported a significant improvement in the quality of life, which was confirmed by questionnaire findings. Conclusion. The use of combined laparovaginal strategy makes it possible to perform the reconstruction of pelvic floor in all its sections and to achieve high anatomical and functional results with less complications. Key words: pelvic organ prolapse, mesh implant, sacrohysteropexy, combined laparovaginal reconstruction
- 1 January 2025
- Published by Dynasty Publishing House in Voprosy Ginekologii, Akušerstva i Perinatologii
- Vol. 24 (3)
Laparovaginal hybrid pelvic floor reconstruction. A single-center retrospective study
Sacrocolpopexy is the gold standard treatment for pelvic organ prolapse (POP). However, this technique involves extensive dissection of the pelvic floor structures, which has led to a modification of the standard technique. Objective. To study the efficacy and safety of combined laparovaginal hybrid pelvic floor reconstruction. Patients and methods. The study enrolled 74 patients who underwent surgical intervention. The technique included anterior and posterior colporrhaphy, perineoplasty, and simplified sacrohysteropexy. Data from the validated PFDI-20, PISQ-12 and ICIQ-SF questionnaires, analysis of prolapse stages according to the POP-Q system, and the presence of complications were used to evaluate the efficacy. Results. The mean duration of surgery was 162.2 ± 45.2 minutes. Recurrent prolapse that required repeat intervention was recorded in 5% of patients within 12–18 months of follow-up. The symptoms of de novo stress urinary incontinence (SUI) were detected in 4% of patients, and 2.7% experienced worsening of pre-existing SUI. No cases of implant erosion and dyspareunia were recorded. Patients reported a significant improvement in the quality of life, which was confirmed by questionnaire findings. Conclusion. The use of combined laparovaginal strategy makes it possible to perform the reconstruction of pelvic floor in all its sections and to achieve high anatomical and functional results with less complications. Key words: pelvic organ prolapse, mesh implant, sacrohysteropexy, combined laparovaginal reconstruction
- Open Access
- 29 November 2024
- Published by Rostov State Medical University in Urology Herald
- Vol. 12 (5) , 63-73
Comparison of pathomorphologic properties of non-resorbable and partially resorbable implants for reconstructive surgery of pelvic organ prolapse and stress urinary incontinence: an animal model study
Introduction. It is well-known that the use of transvaginal mesh implants is not devoid of specific complications that meaningfully impair the quality of life of female patients. The volume of permanent material used has been shown to correlate closely with the risk of implant-associated complications. Thus, there is a need to develop a new generation of implants that retain the advantages of a permanent mesh implant but with minimal risk of implant-associated complications. Meanwhile, there are insufficient data on the organism's response to this type of synthetic implant.Objective. To compare the histological changes in the soft tissues of the rabbit anterior abdominal wall in the implantation zone of the new generation partially resorbable implant and non-absorbable polypropylene mesh implant on the animal model.Materials & methods. We have previously developed a partially resorbable ligature delivery system for axial fixation of pelvic floor structures, performed technical analysis, and compared biomechanical and pathomorphological properties after implantation in an animal model experiment. The present study was conducted on 39 male rabbits of Chinchilla breed, randomised into three groups according to the type of implanted material: a partially resorbable ligature delivery system Axilen and Axilen Rapid [Lintex, LLC], and a non-resorbable polypropylene mesh implant Urosling. After the rabbits were removed from the experiment, the obtained biomaterial was subjected to histological study.Results. In the group with partially resorbable implants Axilen and Axilen Rapid, less inflammation and better tissue integration were observed compared to the polypropylene implant Urosling. This indicates a potential reduction in the risk of postoperative complications and an improvement in the quality of life for patients.Conclusion. The results of the experimental study confirm the advantages of using partially resorbable implants over traditional polypropylene meshes in pelvic floor reconstructive surgery. However, further research is needed to confirm the long-term safety and effectiveness of the new generation of implants.
- 29 November 2024
- Published by Rostov State Medical University in Urology Herald
- Vol. 12 (5) , 63-73
Open AccessComparison of pathomorphologic properties of non-resorbable and partially resorbable implants for reconstructive surgery of pelvic organ prolapse and stress urinary incontinence: an animal model study
Introduction. It is well-known that the use of transvaginal mesh implants is not devoid of specific complications that meaningfully impair the quality of life of female patients. The volume of permanent material used has been shown to correlate closely with the risk of implant-associated complications. Thus, there is a need to develop a new generation of implants that retain the advantages of a permanent mesh implant but with minimal risk of implant-associated complications. Meanwhile, there are insufficient data on the organism's response to this type of synthetic implant.Objective. To compare the histological changes in the soft tissues of the rabbit anterior abdominal wall in the implantation zone of the new generation partially resorbable implant and non-absorbable polypropylene mesh implant on the animal model.Materials & methods. We have previously developed a partially resorbable ligature delivery system for axial fixation of pelvic floor structures, performed technical analysis, and compared biomechanical and pathomorphological properties after implantation in an animal model experiment. The present study was conducted on 39 male rabbits of Chinchilla breed, randomised into three groups according to the type of implanted material: a partially resorbable ligature delivery system Axilen and Axilen Rapid [Lintex, LLC], and a non-resorbable polypropylene mesh implant Urosling. After the rabbits were removed from the experiment, the obtained biomaterial was subjected to histological study.Results. In the group with partially resorbable implants Axilen and Axilen Rapid, less inflammation and better tissue integration were observed compared to the polypropylene implant Urosling. This indicates a potential reduction in the risk of postoperative complications and an improvement in the quality of life for patients.Conclusion. The results of the experimental study confirm the advantages of using partially resorbable implants over traditional polypropylene meshes in pelvic floor reconstructive surgery. However, further research is needed to confirm the long-term safety and effectiveness of the new generation of implants.
- Open Access
- 2 October 2024
- Published by Springer Nature in Trials
- Vol. 25 (1) , 1-11
The influence of simultaneous posterior colporrhaphy and perineoplasty on the efficiency and safety of mesh-augmented sacrospinal fixation (apical sling) in advanced POP repair
Pelvic organ prolapse (POP) is one of the most common pathologies of the pelvic floor, and it can be found among 40–60% of women who have given birth. Correction of the defect of the DeLancey level II without reconstruction of the apical defect is doomed to failure. Also, in the structure of pelvic floor defects, there is often an incompetency of the perineal body, as a consequence of traumatic delivery. Perineoplasty is considered to be the main method of correction for perineal body incompetency. However, it is worth mentioning that there are no randomized trials, which estimate the influence of simultaneous correction of the perineal body on the effectiveness of transvaginal apical fixation. It is planned to include 310 patients in this trial. Patients who met the inclusion/exclusion criteria will be randomized into 2 groups: 1st group—patients who will undergo mesh-augmented sacrospinal fixation with anterior and posterior colporrhaphy without perineoplasty, 2nd group—patients who will undergo mesh-augmented sacrospinal fixation with anterior and posterior colporrhaphy and perineoplasty. Patients will be called to an appointment 6, 12, and 24 months after discharge. The aim of this trial is to evaluate the efficiency and safety of simultaneous perineoplasty on the clinical and anatomical efficacy of mesh-augmented sacrospinal fixation in advanced pelvic organ prolapse repair. Based on previous studies, it was difficult to estimate and comprehend whether colpoperinoplasty actually reduces the risk of prolapse recurrence. NCT05422209. Registered on 18 May 2022.
- 2 October 2024
- Published by Springer Nature in Trials
- Vol. 25 (1) , 1-11
Open AccessThe influence of simultaneous posterior colporrhaphy and perineoplasty on the efficiency and safety of mesh-augmented sacrospinal fixation (apical sling) in advanced POP repair
Pelvic organ prolapse (POP) is one of the most common pathologies of the pelvic floor, and it can be found among 40–60% of women who have given birth. Correction of the defect of the DeLancey level II without reconstruction of the apical defect is doomed to failure. Also, in the structure of pelvic floor defects, there is often an incompetency of the perineal body, as a consequence of traumatic delivery. Perineoplasty is considered to be the main method of correction for perineal body incompetency. However, it is worth mentioning that there are no randomized trials, which estimate the influence of simultaneous correction of the perineal body on the effectiveness of transvaginal apical fixation. It is planned to include 310 patients in this trial. Patients who met the inclusion/exclusion criteria will be randomized into 2 groups: 1st group—patients who will undergo mesh-augmented sacrospinal fixation with anterior and posterior colporrhaphy without perineoplasty, 2nd group—patients who will undergo mesh-augmented sacrospinal fixation with anterior and posterior colporrhaphy and perineoplasty. Patients will be called to an appointment 6, 12, and 24 months after discharge. The aim of this trial is to evaluate the efficiency and safety of simultaneous perineoplasty on the clinical and anatomical efficacy of mesh-augmented sacrospinal fixation in advanced pelvic organ prolapse repair. Based on previous studies, it was difficult to estimate and comprehend whether colpoperinoplasty actually reduces the risk of prolapse recurrence. NCT05422209. Registered on 18 May 2022.
- 4 December 2023
- Published by Wiley in Neurourology and Urodynamics
- Vol. 43 (2) , 311-319
Tunable tension tape versus transobturator tape in treatment of stress urinary incontinence in women: Randomized controlled trial
Introduction: The synthetic mid‐urethral slings are currently considered to be the most widely used technique for the surgical treatment of stress urinary incontinence (SUI). The most challenging aspect of the existing approaches is to achieve the optimal tension of the sling which treatment results are directly dependent on. To solve this problem, sling systems enabling an adjustment of the tension in the early postoperative period were created. A comparative study of the effectiveness and safety of such a system and a nonadjustable sling seems to be a relevant task.Materials and Methods: A double‐blind, randomized, multicenter trial enrolled 320 patients with a mean age of 55.2 ± 11.2 years and confirmed SUI. Patients were randomized into two groups: the first group underwent a standard synthetic suburethral sling (transobturator tape [TOT]) procedure and the second group underwent a tunable tension tape sling (TTT) procedure. All patients underwent stress test, uroflowmetry and ultrasound scan to determine the postvoid residual volume. Urinary Distress Inventory Short Form 6, International Consultation on Incontinence Questionnaire—Short Form, Pelvic Organ Prolapse Incontinence Sexual Questionnaire 12 questionnaires were used to assess subjective efficacy.Results: Enhancement of prosthesis tension in the second group was required in 44 (28%) patients. Due to the possibility of tightening of the sling in the early postoperative period, the operation was effective in 143 (89%) patients in the adjustable sling group and in 109 (68%) patients in Group 1, p < 0.001. Loosening of the sling tension was performed in 25 (16%) patients in Group 2. The signs of obstructive voiding symptoms at the follow‐up time of 36 months remained in Group 1 in 13 (8%) patients. Subjective satisfaction with treatment on the PGI‐I scale was higher in Group 2: 100 (62%) versus 132 (82%), p < 0.001.Conclusion: A synthetic mid‐urethral TTT is superior to a standard nonadjustable sling in long‐term effectiveness and safety.
- 4 December 2023
- Published by Wiley in Neurourology and Urodynamics
- Vol. 43 (2) , 311-319
Tunable tension tape versus transobturator tape in treatment of stress urinary incontinence in women: Randomized controlled trial
Introduction: The synthetic mid‐urethral slings are currently considered to be the most widely used technique for the surgical treatment of stress urinary incontinence (SUI). The most challenging aspect of the existing approaches is to achieve the optimal tension of the sling which treatment results are directly dependent on. To solve this problem, sling systems enabling an adjustment of the tension in the early postoperative period were created. A comparative study of the effectiveness and safety of such a system and a nonadjustable sling seems to be a relevant task.Materials and Methods: A double‐blind, randomized, multicenter trial enrolled 320 patients with a mean age of 55.2 ± 11.2 years and confirmed SUI. Patients were randomized into two groups: the first group underwent a standard synthetic suburethral sling (transobturator tape [TOT]) procedure and the second group underwent a tunable tension tape sling (TTT) procedure. All patients underwent stress test, uroflowmetry and ultrasound scan to determine the postvoid residual volume. Urinary Distress Inventory Short Form 6, International Consultation on Incontinence Questionnaire—Short Form, Pelvic Organ Prolapse Incontinence Sexual Questionnaire 12 questionnaires were used to assess subjective efficacy.Results: Enhancement of prosthesis tension in the second group was required in 44 (28%) patients. Due to the possibility of tightening of the sling in the early postoperative period, the operation was effective in 143 (89%) patients in the adjustable sling group and in 109 (68%) patients in Group 1, p < 0.001. Loosening of the sling tension was performed in 25 (16%) patients in Group 2. The signs of obstructive voiding symptoms at the follow‐up time of 36 months remained in Group 1 in 13 (8%) patients. Subjective satisfaction with treatment on the PGI‐I scale was higher in Group 2: 100 (62%) versus 132 (82%), p < 0.001.Conclusion: A synthetic mid‐urethral TTT is superior to a standard nonadjustable sling in long‐term effectiveness and safety.
- Open Access
- 25 June 2023
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 16 (2)
Midurethral synthetic tuneable tension tape in treatment of stress urinary incontinence in women.
Introduction. The use of midurethral synthetic slings is currently considered to be the most widespread treatment option for stress urinary incontinence (SUI). The most difficult in the existing approaches is to achieve the optimal tension of the sling, on which the result of treatment directly depends. To solve this problem, sling systems with the possibility of tension adjustment in the early postoperative period were created. A comparative study of the effectiveness and safety of such a system and a sling without the possibility of adjustment seems to be a relevant task. Materials and Methods. The study involved 320 female patients with a mean age of 55.2±11.2 years and a confirmed diagnosis of SUI. The patients were allocated into two groups: the first group underwent a synthetic suburethral sling by the standard technique (TOT); the second group received a suburethral sling with early mobilization (TTT). All patients underwent stress test, uroflowmetry and ultrasound investigation to determine the volume of residual urine. UDI-6, ICIQ-SF, PISQ-12 questionnaires were filled out to assess subjective efficiency. Results. In the second group, 28% of the patients needed to increase the tension of the prosthesis. Due to the possibility of tightening the sling in the early postoperative period, the operation was ineffective at the delayed follow-up stage at 36 months only in 11% of the women in the TTT group and in 32% of the patients in the LTT group, p<0.001. Loosening the sling tension was required in every fourth patient in the TTT group. Signs of obstructive urination at the stage of 36 months persisted in 13 patients in the TOT group and were completely absent in the TTT group. Subjective satisfaction with treatment was higher in the TTT group and amounted to 82%. Conclusion. A synthetic mid-urethral tuneable tension tape is superior to a classic sling without adjustment capability in long-term efficacy and safety.
- 25 June 2023
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 16 (2)
Open AccessMidurethral synthetic tuneable tension tape in treatment of stress urinary incontinence in women.
Introduction. The use of midurethral synthetic slings is currently considered to be the most widespread treatment option for stress urinary incontinence (SUI). The most difficult in the existing approaches is to achieve the optimal tension of the sling, on which the result of treatment directly depends. To solve this problem, sling systems with the possibility of tension adjustment in the early postoperative period were created. A comparative study of the effectiveness and safety of such a system and a sling without the possibility of adjustment seems to be a relevant task. Materials and Methods. The study involved 320 female patients with a mean age of 55.2±11.2 years and a confirmed diagnosis of SUI. The patients were allocated into two groups: the first group underwent a synthetic suburethral sling by the standard technique (TOT); the second group received a suburethral sling with early mobilization (TTT). All patients underwent stress test, uroflowmetry and ultrasound investigation to determine the volume of residual urine. UDI-6, ICIQ-SF, PISQ-12 questionnaires were filled out to assess subjective efficiency. Results. In the second group, 28% of the patients needed to increase the tension of the prosthesis. Due to the possibility of tightening the sling in the early postoperative period, the operation was ineffective at the delayed follow-up stage at 36 months only in 11% of the women in the TTT group and in 32% of the patients in the LTT group, p<0.001. Loosening the sling tension was required in every fourth patient in the TTT group. Signs of obstructive urination at the stage of 36 months persisted in 13 patients in the TOT group and were completely absent in the TTT group. Subjective satisfaction with treatment was higher in the TTT group and amounted to 82%. Conclusion. A synthetic mid-urethral tuneable tension tape is superior to a classic sling without adjustment capability in long-term efficacy and safety.