Martin Grabenwöger
Martin Grabenwöger has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
Bernhard Winkler
Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund) , Vienna 1210
5 shared publications- Bernhard Winkler
Department of Cardiovascular Surgery, Clinic Floridsdorf, 1210 Vienna, Austria
5 shared publications Zsuzsanna Arnold
Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund) , Vienna 1210
5 shared publications- Daniela Geisler
Department of Cardiovascular Surgery, Clinic Floridsdorf, 1210 Vienna, Austria
4 shared publications - Gabriel Weiss
Department of Cardiovascular Surgery, Clinic Floridsdorf , Vienna, Austria
4 shared publications - Markus Mach
Medical University of Vienna, Austria (M.A., M.M.).
4 shared publications
Latest Publications
- 21 October 2026
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 68 (11-12)
Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection
Objectives: Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion. Methods: A retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure. Results: Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair, and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < .001). There was no stroke, spinal cord ischaemia, or retrograde type A dissection. Thirty-day, in-hospital, and overall mortality were 10%, 14%, and 19%, respectively, with 1 fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months. Conclusions: Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small, heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
- 21 October 2026
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 68 (11-12)
Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection
Objectives: Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion. Methods: A retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure. Results: Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair, and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < .001). There was no stroke, spinal cord ischaemia, or retrograde type A dissection. Thirty-day, in-hospital, and overall mortality were 10%, 14%, and 19%, respectively, with 1 fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months. Conclusions: Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small, heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
- Open Access
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 474
Reintervention for Failed Aortic Bioprostheses: Distinct Patient Profiles for Redo Surgery and Valve-in-Valve TAVR in an All-Comers Cohort
Background/Objectives: Aortic valve therapy increasingly follows a lifetime management concept. As all bioprostheses ultimately degenerate, optimal outcomes rely on the appropriate selection and timing of treatment modality. This study evaluates outcomes of redo surgical aortic valve replacement (redo-SAVR) and valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) in a consecutive, unselected real-world cohort treated for bioprosthetic valve failure (BVF). Methods: A single-center retrospective analysis of all patients undergoing redo-SAVR or ViV-TAVR for BVF between June 2019 and December 2024 was conducted. The primary endpoint was survival at 30 days and at 1, 3, and 5 years; the secondary endpoint was time to reintervention. Cox proportional hazards models were used; proportionality was tested; subgroups were defined by indication and presence of concomitant procedures. Results: Eighty-three patients were included (redo-SAVR n = 42; ViV-TAVR n = 41). All active endocarditis cases were managed surgically. In isolated procedures, 30-day survival was 95.5% after redo-SAVR (100% when excluding endocarditis) and 100% after ViV-TAVR; 5-year survival was 81.3% and 94.1%, respectively (94.4% for isolated redo-SAVR excluding endocarditis). Because hazards were non-proportional and risk sets were sparse beyond 5 years, we fitted a time-split Cox model (0–5 years). In multivariable analysis, endocarditis (HR 4.45, 95% CI 1.16–17.04) and NYHA IV (HR 4.87, 95% CI 0.98–24.17)—not treatment modality—were associated with mortality. Conclusions: In a real-world, all-comers setting, early outcomes for isolated reinterventions were favorable with both pathways. Mortality patterns were case-mix driven—especially by endocarditis and the need for concomitant surgery. Accordingly, ViV-TAVR and redo-SAVR should be viewed not as competing procedures but as complementary, scenario-specific options within a lifetime management strategy.
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 474
Open AccessReintervention for Failed Aortic Bioprostheses: Distinct Patient Profiles for Redo Surgery and Valve-in-Valve TAVR in an All-Comers Cohort
Background/Objectives: Aortic valve therapy increasingly follows a lifetime management concept. As all bioprostheses ultimately degenerate, optimal outcomes rely on the appropriate selection and timing of treatment modality. This study evaluates outcomes of redo surgical aortic valve replacement (redo-SAVR) and valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) in a consecutive, unselected real-world cohort treated for bioprosthetic valve failure (BVF). Methods: A single-center retrospective analysis of all patients undergoing redo-SAVR or ViV-TAVR for BVF between June 2019 and December 2024 was conducted. The primary endpoint was survival at 30 days and at 1, 3, and 5 years; the secondary endpoint was time to reintervention. Cox proportional hazards models were used; proportionality was tested; subgroups were defined by indication and presence of concomitant procedures. Results: Eighty-three patients were included (redo-SAVR n = 42; ViV-TAVR n = 41). All active endocarditis cases were managed surgically. In isolated procedures, 30-day survival was 95.5% after redo-SAVR (100% when excluding endocarditis) and 100% after ViV-TAVR; 5-year survival was 81.3% and 94.1%, respectively (94.4% for isolated redo-SAVR excluding endocarditis). Because hazards were non-proportional and risk sets were sparse beyond 5 years, we fitted a time-split Cox model (0–5 years). In multivariable analysis, endocarditis (HR 4.45, 95% CI 1.16–17.04) and NYHA IV (HR 4.87, 95% CI 0.98–24.17)—not treatment modality—were associated with mortality. Conclusions: In a real-world, all-comers setting, early outcomes for isolated reinterventions were favorable with both pathways. Mortality patterns were case-mix driven—especially by endocarditis and the need for concomitant surgery. Accordingly, ViV-TAVR and redo-SAVR should be viewed not as competing procedures but as complementary, scenario-specific options within a lifetime management strategy.
- Open Access
- 1 September 2025
- Published by AME Publishing Company in Annals of Cardiothoracic Surgery
- Vol. 14 (5) , 335-342
From back table innovation to contemporary application: a review of the frozen elephant trunk technique
The frozen elephant trunk (FET) technique represents a significant advancement in the surgical management of complex aortic pathologies involving the aortic arch and descending thoracic aorta. This review traces the evolution of the FET procedure from its conceptual origins in the conventional elephant trunk (ET) technique to its current application as a hybrid, single-stage intervention. The FET technique integrates open surgical repair with endovascular technology, allowing for simultaneous aortic arch replacement and stent-graft deployment into the descending aorta. Key indications include acute and chronic aortic dissections, arch aneurysms, and malperfusion syndromes. Surgical considerations such as cannulation strategy, cerebral protection, and spinal cord preservation are discussed in detail, with emphasis on techniques that enhance safety and outcomes. The development of commercially available FET prostheses—such as E-vita Open Neo, Thoraflex Hybrid, and Frozenix—has improved procedural versatility and enabled individualized treatment strategies. Innovations in graft design, including proximalization of distal anastomosis and integration of side branches, have further simplified the procedure and broadened its applicability. Despite variability in outcomes across patient populations, the FET procedure is associated with favorable early and mid-term results, including reduced inter-stage mortality and enhanced aortic remodeling. The technique continues to evolve, driven by advances in device technology and a growing emphasis on tailored, patient-specific surgical approaches.
- 1 September 2025
- Published by AME Publishing Company in Annals of Cardiothoracic Surgery
- Vol. 14 (5) , 335-342
Open AccessFrom back table innovation to contemporary application: a review of the frozen elephant trunk technique
The frozen elephant trunk (FET) technique represents a significant advancement in the surgical management of complex aortic pathologies involving the aortic arch and descending thoracic aorta. This review traces the evolution of the FET procedure from its conceptual origins in the conventional elephant trunk (ET) technique to its current application as a hybrid, single-stage intervention. The FET technique integrates open surgical repair with endovascular technology, allowing for simultaneous aortic arch replacement and stent-graft deployment into the descending aorta. Key indications include acute and chronic aortic dissections, arch aneurysms, and malperfusion syndromes. Surgical considerations such as cannulation strategy, cerebral protection, and spinal cord preservation are discussed in detail, with emphasis on techniques that enhance safety and outcomes. The development of commercially available FET prostheses—such as E-vita Open Neo, Thoraflex Hybrid, and Frozenix—has improved procedural versatility and enabled individualized treatment strategies. Innovations in graft design, including proximalization of distal anastomosis and integration of side branches, have further simplified the procedure and broadened its applicability. Despite variability in outcomes across patient populations, the FET procedure is associated with favorable early and mid-term results, including reduced inter-stage mortality and enhanced aortic remodeling. The technique continues to evolve, driven by advances in device technology and a growing emphasis on tailored, patient-specific surgical approaches.
- Open Access
Left Ventricular Reverse Remodeling after Surgical Aortic Valve Replacement for Aortic Regurgitation—An Explorative Study
Background: The timing of treatment for chronic aortic valve regurgitation (AR), especially in asymptomatic patients, is gaining attention since less invasive strategies have become available. The aim of the present study was to evaluate left ventricular reverse remodeling after aortic valve replacement (AVR) for severe AR. Methods: Patients (n = 25) who underwent surgical AVR for severe AR with left ventricular ejection fraction (LVEF) less than 55% were included in this study. Preprocedural and follow-up clinical and echocardiographic measurements of LVEF and left ventricular (LV) diameters were retrospectively analyzed. Results: Mean LVEF increased significantly following surgical AVR (p < 0.0001). LV diameters showed a clear regression (p = 0.0088). Younger patients and those receiving a mechanical valve tended to have less improved LVEF on follow-up than patients over 60 years or the ones who were implanted with a biological prosthesis (p = 0.0239 and p = 0.069, respectively). Gender had no effect on the degree of LVEF improvement (p = 0.4908). Conclusions: We demonstrated significant LV reverse remodeling following AVR for AR. However, more data are needed on LV functional and geometrical improvement comparing the different types of valve prostheses to provide an optimal treatment strategy.
Open AccessLeft Ventricular Reverse Remodeling after Surgical Aortic Valve Replacement for Aortic Regurgitation—An Explorative Study
Background: The timing of treatment for chronic aortic valve regurgitation (AR), especially in asymptomatic patients, is gaining attention since less invasive strategies have become available. The aim of the present study was to evaluate left ventricular reverse remodeling after aortic valve replacement (AVR) for severe AR. Methods: Patients (n = 25) who underwent surgical AVR for severe AR with left ventricular ejection fraction (LVEF) less than 55% were included in this study. Preprocedural and follow-up clinical and echocardiographic measurements of LVEF and left ventricular (LV) diameters were retrospectively analyzed. Results: Mean LVEF increased significantly following surgical AVR (p < 0.0001). LV diameters showed a clear regression (p = 0.0088). Younger patients and those receiving a mechanical valve tended to have less improved LVEF on follow-up than patients over 60 years or the ones who were implanted with a biological prosthesis (p = 0.0239 and p = 0.069, respectively). Gender had no effect on the degree of LVEF improvement (p = 0.4908). Conclusions: We demonstrated significant LV reverse remodeling following AVR for AR. However, more data are needed on LV functional and geometrical improvement comparing the different types of valve prostheses to provide an optimal treatment strategy.
- Open Access
- 2 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
First-in-men experience with a novel frozen elephant trunk prosthesis featuring an endovascular side branch for left subclavian artery connection
OBJECTIVES: The objective of this study was to enhance the efficiency of aortic arch replacement through the development of a novel frozen elephant trunk (FET) prosthesis with an endovascular side branch for left subclavian artery (LSA) connection. After successful pre-clinical testing, the feasibility and safety of implementing this innovative prosthesis in human subjects were investigated. METHODS: Between September 2020 and September 2021, 4 patients (mean age 67) with conditions such as penetrating ulcer, non A–non B aortic dissection and chronic arch aneurysm underwent surgery utilizing the customized device. Surgeries were performed under high moderate hypothermia (27°C), employing bilateral selective antegrade cerebral perfusion (SACP) and distal aortic perfusion. Anastomosis of the FET prosthesis with the aortic arch occurred in zone 1, followed by separate reimplantation of the left common carotid artery and the brachiocephalic artery. RESULTS: All patients were discharged in good clinical condition. The mean aortic cross-clamp, antegrade selective cerebral perfusion and distal aortic perfusion times were 111, 71 and 31 min, respectively. Endovascular extension of the side branch for the LSA was required in all cases to prevent endoleak formation. One patient received a stent graft extension at the end of the operation, while 2 others underwent the procedure during their hospital stay. One patient was diagnosed with an endoleak at the first follow-up after 3 months, and endoleak sealing was achieved via the brachial artery with an extension stent graft. CONCLUSIONS: Preliminary clinical outcomes suggest that the newly designed FET prosthesis shows promise in simplifying total arch replacement. These initial findings provide a foundation for planned clinical studies to further assess the effectiveness of this modified surgical hybrid graft, with particular attention to the length and diameter of the LSA sidearm.
- 2 August 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
Open AccessFirst-in-men experience with a novel frozen elephant trunk prosthesis featuring an endovascular side branch for left subclavian artery connection
OBJECTIVES: The objective of this study was to enhance the efficiency of aortic arch replacement through the development of a novel frozen elephant trunk (FET) prosthesis with an endovascular side branch for left subclavian artery (LSA) connection. After successful pre-clinical testing, the feasibility and safety of implementing this innovative prosthesis in human subjects were investigated. METHODS: Between September 2020 and September 2021, 4 patients (mean age 67) with conditions such as penetrating ulcer, non A–non B aortic dissection and chronic arch aneurysm underwent surgery utilizing the customized device. Surgeries were performed under high moderate hypothermia (27°C), employing bilateral selective antegrade cerebral perfusion (SACP) and distal aortic perfusion. Anastomosis of the FET prosthesis with the aortic arch occurred in zone 1, followed by separate reimplantation of the left common carotid artery and the brachiocephalic artery. RESULTS: All patients were discharged in good clinical condition. The mean aortic cross-clamp, antegrade selective cerebral perfusion and distal aortic perfusion times were 111, 71 and 31 min, respectively. Endovascular extension of the side branch for the LSA was required in all cases to prevent endoleak formation. One patient received a stent graft extension at the end of the operation, while 2 others underwent the procedure during their hospital stay. One patient was diagnosed with an endoleak at the first follow-up after 3 months, and endoleak sealing was achieved via the brachial artery with an extension stent graft. CONCLUSIONS: Preliminary clinical outcomes suggest that the newly designed FET prosthesis shows promise in simplifying total arch replacement. These initial findings provide a foundation for planned clinical studies to further assess the effectiveness of this modified surgical hybrid graft, with particular attention to the length and diameter of the LSA sidearm.
- Open Access
- 3 June 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 65 (6)
E-vita OPEN NEO in the treatment of acute or chronic aortic pathologies: first interim results of the NEOS study
The aim of this multicentre study was to demonstrate the safety and clinical performance of E-vita OPEN NEO Stent Graft System (Artivion, Inc.) in the treatment of aneurysm or dissection, both acute and chronic, in the ascending aorta, aortic arch and descending thoracic aorta. In this observational study of 12 centres performed in Europe and in Asia patients were enrolled between December 2020 and March 2022. All patients underwent frozen elephant trunk using E-vita OPEN NEO Stent Graft System. Primary end point was the rate of all-cause mortality at 30 days and secondary end points included further clinical and safety data are reported up to 3–6 months postoperatively. A total of 100 patients (66.7% male; mean age, 57.7 years) were enrolled at 12 sites. A total of 99 patients underwent surgery using the E-vita OPEN NEO for acute or subacute type A aortic dissection (n = 37), chronic type A aortic dissection (n = 33) or thoracic aortic aneurysm (n = 29), while 1 patient did not undergo surgery. Device technical success at 24 h was achieved in 97.0%. At discharge, new disabling stroke occurred in 4.4%, while new paraplegia and new paraparesis was reported in 2.2% and 2.2%, respectively. Renal failure requiring permanent (>90 days) dialysis or hemofiltration at discharge was observed in 3.3% of patients. Between discharge and the 3–6 months visit, no patients experienced new disabling stroke, new paraplegia or new paraparesis. The 30-day mortality was 5.1% and the estimated 6-month survival rate was 91.6% (standard deviation: 2.9). Total arch replacement with the E-vita OPEN NEO can be performed with excellent results in both the acute and chronic setting. This indicates that E-vita OPEN NEO can be used safely, including in the setting of acute type A aortic dissection.
- 3 June 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 65 (6)
Open AccessE-vita OPEN NEO in the treatment of acute or chronic aortic pathologies: first interim results of the NEOS study
The aim of this multicentre study was to demonstrate the safety and clinical performance of E-vita OPEN NEO Stent Graft System (Artivion, Inc.) in the treatment of aneurysm or dissection, both acute and chronic, in the ascending aorta, aortic arch and descending thoracic aorta. In this observational study of 12 centres performed in Europe and in Asia patients were enrolled between December 2020 and March 2022. All patients underwent frozen elephant trunk using E-vita OPEN NEO Stent Graft System. Primary end point was the rate of all-cause mortality at 30 days and secondary end points included further clinical and safety data are reported up to 3–6 months postoperatively. A total of 100 patients (66.7% male; mean age, 57.7 years) were enrolled at 12 sites. A total of 99 patients underwent surgery using the E-vita OPEN NEO for acute or subacute type A aortic dissection (n = 37), chronic type A aortic dissection (n = 33) or thoracic aortic aneurysm (n = 29), while 1 patient did not undergo surgery. Device technical success at 24 h was achieved in 97.0%. At discharge, new disabling stroke occurred in 4.4%, while new paraplegia and new paraparesis was reported in 2.2% and 2.2%, respectively. Renal failure requiring permanent (>90 days) dialysis or hemofiltration at discharge was observed in 3.3% of patients. Between discharge and the 3–6 months visit, no patients experienced new disabling stroke, new paraplegia or new paraparesis. The 30-day mortality was 5.1% and the estimated 6-month survival rate was 91.6% (standard deviation: 2.9). Total arch replacement with the E-vita OPEN NEO can be performed with excellent results in both the acute and chronic setting. This indicates that E-vita OPEN NEO can be used safely, including in the setting of acute type A aortic dissection.
- Top Cited Papers
- 26 February 2024
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 118 (1) , 5-115
EACTS/STS Guidelines for Diagnosing and Treating Acute and Chronic Syndromes of the Aortic Organ
- 26 February 2024
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 118 (1) , 5-115
Top Cited PapersEACTS/STS Guidelines for Diagnosing and Treating Acute and Chronic Syndromes of the Aortic Organ
- 2 November 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 64 (6)
Invited commentary to: 4D-flow cardiac magnetic resonance for the assEssmeNt of AOrtic valve repair with OzAki TEchnique
Gabriel Weiss, Zsuzsanna Arnold, Martin Grabenwöger, Bernhard Winkler; 4D-flow Cardiac Magnetic Resonance for the assEssmeNt of AOrtic Valve Repair with OzAki T
- 2 November 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 64 (6)
Invited commentary to: 4D-flow cardiac magnetic resonance for the assEssmeNt of AOrtic valve repair with OzAki TEchnique
Gabriel Weiss, Zsuzsanna Arnold, Martin Grabenwöger, Bernhard Winkler; 4D-flow Cardiac Magnetic Resonance for the assEssmeNt of AOrtic Valve Repair with OzAki T
- Open Access
- 20 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (12) , 4143
Long-Term Results with 187 Frozen Elephant Trunk Procedures
The frozen elephant trunk (FET) technique is an established therapeutic option in the treatment of complex aortic diseases. We report our long-term clinical outcomes after FET repair. A total of 187 consecutive patients underwent FET repair at our department between 8/2005 and 3/2023. Indications included acute and chronic aortic dissections and thoracic aneurysms. Endpoints included operative morbidity and mortality, long-term survival, and the need for reinterventions. Operative mortality, spinal cord injury and permanent stroke rates were: 9.6%, 2.7% and 10.2%, respectively. At five years, overall survival was 69.9 ± 3.9% and freedom from aortic-related death was 82.5 ± 3.0%, whereas at ten years, overall survival was 53.0 ± 5.5% and freedom from aortic-related death was 75.8 ± 4.8%. Sixty-one reinterventions on the thoracic aorta were necessary. Freedom from secondary interventions at ten years was 44.7 ± 6.4% overall (63.1 ± 10.0% for acute dissections, 40.8 ± 10.3% for chronic dissections and 28.9 ± 13.1% for aneurysms, respectively). The high reintervention rate for chronic dissections and for aneurysms is related to the pre-existing aortic pathology. Late aortic growth of untreated segments with potentially fatal outcome occurs even after ten years, so careful annual follow-up is mandatory in this patient cohort.
- 20 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (12) , 4143
Open AccessLong-Term Results with 187 Frozen Elephant Trunk Procedures
The frozen elephant trunk (FET) technique is an established therapeutic option in the treatment of complex aortic diseases. We report our long-term clinical outcomes after FET repair. A total of 187 consecutive patients underwent FET repair at our department between 8/2005 and 3/2023. Indications included acute and chronic aortic dissections and thoracic aneurysms. Endpoints included operative morbidity and mortality, long-term survival, and the need for reinterventions. Operative mortality, spinal cord injury and permanent stroke rates were: 9.6%, 2.7% and 10.2%, respectively. At five years, overall survival was 69.9 ± 3.9% and freedom from aortic-related death was 82.5 ± 3.0%, whereas at ten years, overall survival was 53.0 ± 5.5% and freedom from aortic-related death was 75.8 ± 4.8%. Sixty-one reinterventions on the thoracic aorta were necessary. Freedom from secondary interventions at ten years was 44.7 ± 6.4% overall (63.1 ± 10.0% for acute dissections, 40.8 ± 10.3% for chronic dissections and 28.9 ± 13.1% for aneurysms, respectively). The high reintervention rate for chronic dissections and for aneurysms is related to the pre-existing aortic pathology. Late aortic growth of untreated segments with potentially fatal outcome occurs even after ten years, so careful annual follow-up is mandatory in this patient cohort.
- Open Access
- 26 February 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 170-183
Global and local stiffening of ex vivo-perfused stented human thoracic aortas: A mock circulation study
- 26 February 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 170-183
Open AccessGlobal and local stiffening of ex vivo-perfused stented human thoracic aortas: A mock circulation study