BABrook W. Abegaz

Brook W. Abegaz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Brook W. Abegaz has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modified Q-Learning Method for Automatic Voltage Regulation in Wide-Area Multigeneration Systems

    by Brook W. Abegaz, Sina Zarrabian

    The state-estimation and optimal control of multigeneration systems are challenging for wide-area systems having numerous distributed automatic voltage regulators (AVR). This paper proposes a modified Q-learning method and algorithm that aim to improve the convergence of the approach and enhance the dynamic response and stability of the terminal voltage of multiple generators in the experimental Western System Coordinating Council (WSCC) and large-scale IEEE 39-bus test systems. The large-scale experimental testbed consists of a six-area, 39-bus system having ten generators that are connected to ten AVRs. The implementation shows promising results in providing stable terminal voltage profiles and other system parameters across a wide range of AVR systems under different test scenarios including N-1 contingency and fault conditions. The approach could provide significant stability improvement for wide-area systems as compared to the implementation of conventional methods such as using standalone AVR and/or power system stabilizers (PSS) for the wide-area control of power systems.


  • A Parallelized Self-Driving Vehicle Controller Using Unsupervised Machine Learning

    by Brook W. Abegaz

    In this article, a self-driving vehicle controller that optimizes the path a vehicle follows from its initial position to its destination is presented. The methods include clustering-based k-means, hierarchical, Gaussian matrix model, and self-organizing mapping. The real-time parallel implementation of the unsupervised machine learning algorithms could provide fast response times of under one microsecond during the lateral, longitudinal, and angular motion control of the autonomous vehicle. It was observed that a random selection of one of the machine learning methods may not always guarantee the optimality of the position and velocity variables as compared to the desired values. The proposed parallel implementation and optimization of the algorithms could have a significant contribution towards making transportation mobility more reliable and sustainable for future vehicular systems.


  • Open Access

    Clustering methods for the efficient voltage regulation in smart grids

    by Brook W. Abegaz

    In this paper, clustering methods are presented to enhance the stability of automatic voltage regulators using the efficient adjustment of their respective gains. The results show that implementations of some of the clustering algorithms provide better reliability and stability for the feedback‐based voltage regulators as compared to the other methods, namely, a model predictive controller (MPC), a gaussian mixture model (GMM), a self‐organizing mapping (SOM) and hierarchical clustering (HC) methods. Specifically, the K‐Means clustering approach (KM) provided superior stability but a slower rise time of the output voltage of the voltage regulators as compared to the other methods. Furthermore, coordination of the clustering methods is tested for a 10 machine, 39 bus power grid system. The results show that the clustering approach could be applied to improve the efficiency of voltage regulation methods in smart grids and related cyber‐physical systems.


  • Open Access

    Dynamic switching control of buck converters using unsupervised machine learning methods

    by Brook W. Abegaz

    This study presents the implementation of a new unsupervised machine learning based system called a buck converter controller using unsupervised machine learning (ABCML) to control the operation of a type of switching voltage regulators, commonly called buck converters. The system uses the voltage and current state variables of buck converters to evaluate four switching‐based clustering algorithms, namely a Gaussian mixture model, a self‐organising mapping (SOM), a k ‐means clustering and a hierarchical clustering algorithm. Step response results of the controller implementation with the buck converter show that the SOM controller improves the performance of the voltage regulator system by 99.77% in terms of voltage overshoot and by 63.24% in terms of fall time, whereas the hierarchical clustering algorithm improves the settling time of the output voltage by 3.91%. This finding of optimal machine learning implementation approaches and their comparison could be used to improve the stability and the performance of switching voltage regulation systems which are widely used in electronic systems of today.


  • Voltage Regulator Thermal Matrix based Thread Allocation Optimization for a Multi-Core Processor

    by B. Abegaz, J. Kueber

    In this paper, the performance optimization of multi-core processors is addressed with respect to their temporal and thermal behavior. This paper uses the location of voltage regulators to monitor temperature fluctuations by determining the task allocation on the processors. The algorithm protects the processor from overheating and simultaneously ensures that the program runs at an optimal speed. The proposed technique has a comparatively fast runtime of O(logn) as compared to other task optimization algorithms. A four-threaded task delegated to an eight core processor with sixteen voltage regulators is optimized for allocation in approximately 2 milliseconds, regardless of the number of instructions in each thread. The proposed technique will efficiently delegate tasks to processors while maintaining the safe operating areas and temperature ranges in the processor.

  • Detection of Saturation and Reconstruction of the Secondary Current of a CT

    by Ganesh Balu Kumbhar, Satish M. Mahajan

    During a short circuit condition, core of a Current Transformer (CT) may become saturated due to large primary current containing a significant DC component. The saturation of the core distorts the secondary current which may cause malfunction of the protective devices connected to the CT. As a result of significant advances in the technology and deployment of digital relays in the last decade, the distorted secondary current can be reconstructed in a very short time. Several methods, which take into account the non-linear behavior of the CT, have been researched in the recent past. Processing time, accuracy, and online implementation are of prime importance while selecting a particular algorithm. In this paper, a comprehensive review of the different algorithms used for the detection of saturation as well as reconstruction of the distorted secondary current is presented.

  • Transient Stability Constrained Line-Flow-Based Optimal Power Flow Analysis

    by Lazarus O. Uzoechi, Satish M. Mahajan, Ghadir Radman

    This paper establishes a new method that adopts the line-flow-based (LFB) approach to develop a transient stability constrained optimal power flow (OPF) analysis called LFB-TSCOPF. The transient energy function (TEF) serves as a direct means of carrying out the stability analysis. The reduction technique was adopted in which the classical machine model was reduced to the internal node model. The proposed method was tested on the WECC 9-bus, three-machine, IEEE 14-bus, five-machine, and the New England 39-bus, ten-machine test systems. The results were compared with other known results from different methods in literature. The results of the active power and total optimal costs are quite promising and consistent with other known methods. The LFB-TSCOPF re-dispatches real power by applying the energy margin performance index as an indication of the generator unit(s) to be rescheduled. The LFB-TSCOPF provides a more comprehensive linear model, reduces computation time and can be useful for online stability studies.

  • A Transient Stability Constrained, Line-Flow-Based Fast Contingency Screening and Power Flow Evaluation

    by Lazarus O. Uzoechi, Satish M. Mahajan

    A new methodology for a possible fast evaluation of a power flow is presented. The proposed method involves a transient stability constrained line-flow-based (LFB) fast contingency screening. This ‘direct’ method incorporates transient energy function (TEF) to carry out the evaluation of a power system. The proposed LFB method was tested on the WECC 9-bus, three machine, the IEEE 14-bus, five machine, and the IEEE 39-bus, ten machine systems. Results of the proposed LFB were compared with those obtained from the conventional Newton-Raphson (N-R) method. It was observed that the stable re-dispatch could be obtained by the LFB method within half the computation time as compared to the time required for the N-R method. Since the LFB method was based upon identification of the stable equilibrium points of the TEF, the proposed method appears to be inherently capable of delivering a stable power dispatch. In addition, a new index called critical energy performance index (CEPI) has been introduced to indicate the level of stability and to assist in the decisions related to the re-dispatch.

  • Optimal Perturbation Tolerance in VSC-Connected Hybrid Networks Using an Expert System on Chip

    by Brook W. Abegaz, Satish M. Mahajan

    A major challenge in the stable operation of hybrid power networks is that such systems operate under the influence of perturbations from source fluctuations and from dynamic storage operations. In the current practice, hybrid power networks are operated and controlled by higher-level supervisory control systems using approaches such as droop control logic that may not make use of the accurate network models, full state measurements, and learning mechanisms to deal with the convoluted perturbations on voltage source converters (VSCs). These perturbations could result from natural variations, parameter uncertainties, grid faults, variable loadings, controller settings, and other exogenous disturbances. So far, these perturbations have been considered as lumped terms that do not represent the correlation of perturbations across the network components. In this paper, an integrated, on-chip expert system (EXPSOC) is proposed to compute the correlation between power variables in separate modules, to perform state estimation of power and voltage variables and to improve the tolerance of perturbations in the hybrid networks. Results show the optimality of the approach in controlling dynamic power perturbations and in keeping the stability of the voltage, frequency and power variables at the level of grid connected VSCs.


  • Electromechanical Wave Analysis Through Transient Magnetic Modeling

    by Adam J. Thomas, Satish M. Mahajan

    Sudden changes in the status of an electrical power system involving generation, loading, or fault conditions result in disturbances in the system, which often cause undesired operation. These disturbances propagate through the system in the form of waves in the phase angle of the voltage until they disperse and normal conditions are restored. Electromechanical characteristics of these waves have been modeled in the past through discrete and continuum approaches. In this paper, a simplified method for numerically solving the governing continuum equations is presented. These equations are represented as electromagnetic equations so that software designed for electromagnetics can be used for continuum power systems. The ability to use commercial software leads to several advantages, among them increased flexibility and reduced computational time, as well as avoiding the need to work directly with tensor fields and Gaussian filters. Continuum network equations can be represented as either an electrostatic or magnetostatic problem, while continuum dynamics, such as generator swing equations, can be represented as electric circuits. The proposed model was tested on the highly anisotropic 27-bus New England system and compared with the continuum model of the same system, with comparable results.