Ashwin Iyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ashwin Iyer has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Krysten Lambeth
Lampe Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, USA
3 shared publications - Nitin Sharma
UNC/NC State Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, USA
3 shared publications - Qiang Zhang
The University of Alabama
2 shared publications - Kang Kim
Department of Bioengineering, University of Pittsburgh, Pittsburgh, USA
1 shared publication - Mayank Singh
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
1 shared publication Ziyue Sun
UNC and NC State Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
1 shared publication
Latest Publications
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 145-150
Dynamic Active Subspaces for Model Predictive Allocation in Over-Actuated Systems
In this letter, we analyze dynamic optimization problem for robotic systems utilizing dynamic active subspaces (DyAS) to obtain a lower-dimensional control input space by performing a global sensitivity analysis. In doing so, we set up a Model Predictive Control Allocation (MPCA) problem wherein the actuators are dynamically allocated to track a desired stabilizing torque while satisfying state and control constraints. To improve computational efficiency of the MPCA, we develop Koopman operator-based linear prediction dynamics of an over-actuated nonlinear robotic system. We demonstrate the derived results on a hybrid neuroprosthesis model for a trajectory tracking task wherein we show a muscle fatigue-based joint torque allocation among motor and functional electrical stimulation (FES) actuators.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 145-150
Dynamic Active Subspaces for Model Predictive Allocation in Over-Actuated Systems
In this letter, we analyze dynamic optimization problem for robotic systems utilizing dynamic active subspaces (DyAS) to obtain a lower-dimensional control input space by performing a global sensitivity analysis. In doing so, we set up a Model Predictive Control Allocation (MPCA) problem wherein the actuators are dynamically allocated to track a desired stabilizing torque while satisfying state and control constraints. To improve computational efficiency of the MPCA, we develop Koopman operator-based linear prediction dynamics of an over-actuated nonlinear robotic system. We demonstrate the derived results on a hybrid neuroprosthesis model for a trajectory tracking task wherein we show a muscle fatigue-based joint torque allocation among motor and functional electrical stimulation (FES) actuators.
- 30 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (3) , 989-1005
Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction
Open- or closed-loop functional electrical stimulation (FES) has been widely investigated to treat drop foot syndrome, which is typically caused by weakness or paralysis of ankle dorsiflexors. However, conventional closed-loop FES control mainly uses kinematic feedback, which does not directly capture time-varying changes in muscle activation. In this study, we explored the use of ultrasound (US) echogenicity as an indicator of FES-evoked muscle activation and hypothesized that including US-derived muscle activation, in addition to kinematic feedback, would improve the closed-loop FES control performance compared to the closed-loop control that relies only on the kinematic feedback. A sampled-data observer (SDO) was derived to continuously estimate FES-evoked muscle activations from low-sampled US echogenicity signals. In addition, a dynamic surface controller (DSC) and a delay compensation (DC) term were incorporated with the SDO, denoted as the US-based DSC-DC, to drive the actual ankle dorsiflexion trajectory to the desired profile. The trajectory tracking error convergence of the closed-loop system was proven to be uniformly ultimately bounded based on the Lyapunov–Krasovskii stability analysis. The US-based DSC-DC controller was validated on five participants with no disabilities to control their ankle dorsiflexion during walking on a treadmill. The US-based DSC-DC controller significantly reduced the root-mean-square error of the ankle joint trajectory tracking by 46.52% ± 7.99% ( $p < 0.001$ ) compared to the traditional DSC-DC controller with only kinematic feedback but no US measurements. The results also verified the disturbance rejection performance of the US-based DSC-DC controller when a plantarflexion disturbance was added. Our control design, for the first time, provides a methodology to integrate US in an FES control framework, which will likely benefit persons with drop foot and those with other mobility disorders.
- 30 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (3) , 989-1005
Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction
Open- or closed-loop functional electrical stimulation (FES) has been widely investigated to treat drop foot syndrome, which is typically caused by weakness or paralysis of ankle dorsiflexors. However, conventional closed-loop FES control mainly uses kinematic feedback, which does not directly capture time-varying changes in muscle activation. In this study, we explored the use of ultrasound (US) echogenicity as an indicator of FES-evoked muscle activation and hypothesized that including US-derived muscle activation, in addition to kinematic feedback, would improve the closed-loop FES control performance compared to the closed-loop control that relies only on the kinematic feedback. A sampled-data observer (SDO) was derived to continuously estimate FES-evoked muscle activations from low-sampled US echogenicity signals. In addition, a dynamic surface controller (DSC) and a delay compensation (DC) term were incorporated with the SDO, denoted as the US-based DSC-DC, to drive the actual ankle dorsiflexion trajectory to the desired profile. The trajectory tracking error convergence of the closed-loop system was proven to be uniformly ultimately bounded based on the Lyapunov–Krasovskii stability analysis. The US-based DSC-DC controller was validated on five participants with no disabilities to control their ankle dorsiflexion during walking on a treadmill. The US-based DSC-DC controller significantly reduced the root-mean-square error of the ankle joint trajectory tracking by 46.52% ± 7.99% ( $p < 0.001$ ) compared to the traditional DSC-DC controller with only kinematic feedback but no US measurements. The results also verified the disturbance rejection performance of the US-based DSC-DC controller when a plantarflexion disturbance was added. Our control design, for the first time, provides a methodology to integrate US in an FES control framework, which will likely benefit persons with drop foot and those with other mobility disorders.
- Open Access
Ultrasound Echogenicity as an Indicator of Muscle Fatigue during Functional Electrical Stimulation
Functional electrical stimulation (FES) is a potential neurorehabilitative intervention to enable functional movements in persons with neurological conditions that cause mobility impairments. However, the quick onset of muscle fatigue during FES is a significant challenge for sustaining the desired functional movements for more extended periods. Therefore, a considerable interest still exists in the development of sensing techniques that reliably measure FES-induced muscle fatigue. This study proposes to use ultrasound (US) imaging-derived echogenicity signal as an indicator of FES-induced muscle fatigue. We hypothesized that the US-derived echogenicity signal is sensitive to FES-induced muscle fatigue under isometric and dynamic muscle contraction conditions. Eight non-disabled participants participated in the experiments, where FES electrodes were applied on their tibialis anterior (TA) muscles. During a fatigue protocol under either isometric and dynamic ankle dorsiflexion conditions, we synchronously collected the isometric dorsiflexion torque or dynamic dorsiflexion angle on the ankle joint, US echogenicity signals from TA muscle, and the applied stimulation intensity. The experimental results showed an exponential reduction in the US echogenicity relative change (ERC) as the fatigue progressed under the isometric () and dynamic () conditions. The experimental results also implied a strong linear relationship between US ERC and TA muscle fatigue benchmark (dorsiflexion torque or angle amplitude), with values of and under isometric and dynamic conditions, respectively. The findings in this study indicate that the US echogenicity signal is a computationally efficient signal that strongly represents FES-induced muscle fatigue. Its potential real-time implementation to detect fatigue can facilitate an FES closed-loop controller design that considers the FES-induced muscle fatigue.Open AccessUltrasound Echogenicity as an Indicator of Muscle Fatigue during Functional Electrical Stimulation
Functional electrical stimulation (FES) is a potential neurorehabilitative intervention to enable functional movements in persons with neurological conditions that cause mobility impairments. However, the quick onset of muscle fatigue during FES is a significant challenge for sustaining the desired functional movements for more extended periods. Therefore, a considerable interest still exists in the development of sensing techniques that reliably measure FES-induced muscle fatigue. This study proposes to use ultrasound (US) imaging-derived echogenicity signal as an indicator of FES-induced muscle fatigue. We hypothesized that the US-derived echogenicity signal is sensitive to FES-induced muscle fatigue under isometric and dynamic muscle contraction conditions. Eight non-disabled participants participated in the experiments, where FES electrodes were applied on their tibialis anterior (TA) muscles. During a fatigue protocol under either isometric and dynamic ankle dorsiflexion conditions, we synchronously collected the isometric dorsiflexion torque or dynamic dorsiflexion angle on the ankle joint, US echogenicity signals from TA muscle, and the applied stimulation intensity. The experimental results showed an exponential reduction in the US echogenicity relative change (ERC) as the fatigue progressed under the isometric () and dynamic () conditions. The experimental results also implied a strong linear relationship between US ERC and TA muscle fatigue benchmark (dorsiflexion torque or angle amplitude), with values of and under isometric and dynamic conditions, respectively. The findings in this study indicate that the US echogenicity signal is a computationally efficient signal that strongly represents FES-induced muscle fatigue. Its potential real-time implementation to detect fatigue can facilitate an FES closed-loop controller design that considers the FES-induced muscle fatigue.