TLTaekhee Lee

Taekhee Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Taekhee Lee has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Martin Harper

    Department of Environmental Engineering Sciences, University of Florida , Black Hall, 1128 Center Drive, Gainesville, FL 32611

    15 shared publications
  • Jhy-Charm Soo

    A Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Centers for Disease Control and Prevention , Morgantown , West Virginia

    5 shared publications
  • Michael Kashon

    D Biostatistics and Epidemiology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health , Centers for Disease Control and Prevention , Morgantown , West Virginia

    5 shared publications
  • Emanuele Cauda

    Health Hazards Prevention Branch, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention , 626 Cochrans Mill Road, Pittsburgh, PA 15236

    4 shared publications
  • William P. Chisholm

    A Exposure Assessment Branch , Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention , Morgantown , West Virginia

    4 shared publications
  • Daniel Farcas

    Department of Occupational and Environmental Health Sciences, West Virginia University, Morgantown, WV 26505, USA

    2 shared publications

Latest Publications

  • Recommended flow rate of the aluminum cyclone for improved exposure assessment

    by Sena Yang, Martin Harper, Emanuele Cauda, Taekhee Lee

    Samples of the respirable fraction of airborne particles to which workers are exposed are an important component of many health protection programs, especially in those workplaces where there is a risk of health problems from exposure to respirable crystalline silica. The most common technique for size-selection of the respirable dust fraction is to use a miniature cyclone preselector, many of which are based on the “Higgens-Dewell” (HD) design. A variant of the HD cyclone, commonly referred to as the “aluminum (or aluminium) cyclone,” was developed in Scandinavia. Early work showed that a flow rate of 2.2 l min−1 would be appropriate to meet the size-separation convention standardized under the International Organization for Standardization (ISO), while a later, non-peer-reviewed study suggested 2.5 l min−1 and this flow rate is currently recommended by the manufacturers. The International Sampler Comparison Group is working on revising the European Standard EN13205 on sampler performance testing for consideration as an ISO standard. In this work, 5 aluminum cyclone units were tested at 2.5 l min−1 and the cyclones were further tested at 2.3 and 2.2 l min−1 to determine the optimal flow rate. While the flow rate of 2.3 l min−1 had the lowest overall mean bias, a flow rate of 2.2 l min−1 gave bias <±10% over the whole area of size distributions of interest. This supports earlier findings and suggests that 2.2 l min−1 is the most accurate flow rate for sampling with the aluminum cyclone. However, 2.3 l min−1 also meets the specification of EN13205 in that the area of bias >±10% is minimal. The consequence of continuing to use the aluminum cyclone at 2.5 l min−1 is an underestimate of respirable particles when compared with the ISO convention.


  • Asbestos identification in bulk samples using FTIR and multivariate data analysis

    by Salman Alquwayi, Cody Wolfe, Sena Yang, Bryan Bandli, Steven E. Mischler, Taekhee Lee


  • A cough simulator constructed from off-the-shelf and 3D-printed components

    by Lee Portnoff, Taekhee Lee

    The development of low-cost research equipment is crucial for enhancing accessibility in scientific research, particularly in the field of respiratory disease transmission. This study presents a novel, customizable cough simulator designed for ad-hoc studies that require precise control over ejection velocity and aerosol size. Constructed from off-the-shelf parts and 3D-printed components, this programmable, piston-driven simulator offers an affordable solution for researchers. Its performance has been validated, demonstrating suitability for evaluating fluid flow and monitoring ejected particles that correspond to the velocities of mouth breathing and coughing. Potential applications for this device include assessments of aerosol ventilation, disinfection, and the efficacy of personal protective equipment, all of which contribute to advancing scientific understanding and public health outcomes.

  • Evaluation of a prototype local ventilation system to mitigate retail store worker exposure to airborne particles

    by Taekhee Lee, Teresa L. Barone, David S. Yantek, Lee Portnoff, Yi Zheng

    The objective of this study is to evaluate a prototype local ventilation system (LVS) intended to reduce retail store workers’ exposures to aerosols. The evaluation was carried out in a large aerosol test chamber where relatively uniform concentrations of polydisperse sodium chloride and glass-sphere particles were generated to test the system with nano- and micro-size particles. In addition, a cough simulator was constructed to mimic aerosols released by mouth breathing and coughing. Particle reduction efficiencies of the LVS were determined in four different experimental conditions using direct reading instruments and inhalable samplers. The particle reduction efficiency (%) depended on the position beneath the LVS, but the percentage was consistently high at the LVS center as follows: 1) > 98% particle reduction relative to background aerosols, 2) > 97% in the manikin’s breathing zone relative to background aerosols, 3) > 97% during mouth breathing and coughing simulation, and 4) > 97% with a plexiglass barrier installation. Lower particle reduction (<70%) was observed when the LVS airflow was disturbed by background ventilation airflow. The lowest particle reduction (<20%) was observed when the manikin was closest to the simulator during coughing.


  • Asbestos fiber length and width comparison between manual and semi-automated measurements

    by Taekhee Lee, Teresa Barone, Elaine Rubinstein, Steven Mischler

    The objective of the present study is to find a fast and accurate procedure to measure the length and width of asbestos fibers using images acquired by a scanning electron microscope (SEM), a phase contrast microscope (PCM), and a polarized light microscope (PLM). The accuracy of the procedure was evaluated by comparing fiber length and width measurements to manual measurements. Four different types of images were used in the evaluation: 1) backscattered electron SEM images of fibrous tremolite, 2) secondary electron SEM images of fibrous grunerite, 3) PCM images of fibrous grunerite, and 4) PLM images of fibrous grunerite. Fiber length and width were measured with ImageJ (manual measurement) and Image-Pro software and were compared on an individual fiber basis and over the number-length and number-width distribution of each sample. The results of the comparison showed that the individual length and width measurements with ImageJ and Image-Pro software had a nearly 1:1 relationship except for the width measurement in PLM images (8% of the variance in ImageJ width measurements was not explained by Image-Pro width measurements). Similarly, the number-length distributions were not significantly different (p > 0.05) between ImageJ and Image-Pro, but the number-width distributions were significantly different (p < 0.05) for PLM and secondary electron SEM images. Although the image analysis procedure for measuring fiber length and width with Image-Pro is not a fully automated procedure and still requires some manual intervention, it can be a more efficient and equally accurate alternative to time-consuming manual fiber length and width measurements for well dispersed fibers with high aspect ratios.


  • Size Separation of Amosite by Filtration and Shaking Methods

    by Taekhee Lee, Rachel Walker, Jon Hummer, Elizabeth Ashley, Steven Mischler

    The objectives of this study are (1) to separate fibrous grunerite (amosite) by its length using filtration and shaking techniques utilized in a previous study and (2) to create two distinct length groups (short and long) of the amosite with higher output in a cost-effective way. The shaking system included an electrodynamic exciter, a linear power amplifier, and an audio-frequency signal generator and was attached to a cowl sampler as a funnel loaded with a polycarbonate filter. A suspension of amosite was passed through the 10-μm pore size polycarbonate filter in the shaking system and was transferred to a filtration system through five different pore sizes of polycarbonate membrane filters in series from the top: 10-, 5-, 2-, 1-, and 0.2-μm pore sizes. Each polycarbonate filter was tightly clamped with two conductive 25-mm spacers with a 25-mm stainless steel support screen to prevent leakage. The amosite length and diameter were manually measured with images from a field emission scanning electron microscope (FESEM). A sequence of fields was selected at random locations, and an image of each field was acquired. The length and width of approximately 500 fibers for each sample were measured with ImageJ software. Two significantly different length groups (short and long) of amosite were collected (p <0.05). Approximately 95% of separated amosite (n = 499) using the filtration system were shorter than 5 μm (short fiber group), and approximately 80% of separated amosite (n = 503) using the shaking system were longer than 5 μm (long fiber group).


  • Aerodynamic size separation of glass fiber aerosols

    by Taekhee Lee, Bon Ki Ku, Rachel Walker, Pramod Kulkarni, Teresa Barone, Steven Mischler

    The objective of this study was to investigate the efficacy of an aerodynamic separation scheme for obtaining aerosols with nearly monodisperse fiber lengths as test samples for mechanistic toxicological evaluations. The approach involved the separation of aerosolized glass fibers using an Aerodynamic Aerosol Classifier (AAC) or a multi-cyclone sampling array, followed by the collection of separated samples on filter substrates, and the measurement of each sample fiber length distribution. A glass fiber aerosol with a narrow range of aerodynamic sizes was selected and sampled with the AAC or multi-cyclone sampling array in two separate setups. The fiber length and diameter were measured using a field emission scanning electron microscope. The glass fiber aerosol was separated in distinct groups of eight with the AAC and of four with the multi-cyclone sampling array. The geometric standard deviations of the fiber length distributions of the separated aerosols ranged from 1.49 to 1.69 for the AAC and from 1.6 to 1.8 for multi-cyclone sampling array. While the separation of glass fiber aerosols with an AAC is likely to produce two different length fiber groups and the length resolution may be acceptable, the overall mass throughput of these separation schemes is limited.


  • Comparative cytotoxicity of respirable surface-treated/untreated calcium carbonate rock dust particles in vitro

    by Timur O. Khaliullin, Elena R. Kisin, Naveena Yanamala, Supraja Guppi, Martin Harper, Taekhee Lee, Anna A. Shvedova