Wan Nurshazwani Wan Zakaria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wan Nurshazwani Wan Zakaria has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Razali Tomari
Universiti Tun Hussein Onn Malaysia
15 shared publications Mohd Razali Md Tomari
Faculty of Electrical and Electronic Engineering, University of Tun Hussein Onn, 86400 Parit Raja, Batu Pahat, Johor, Malaysia
9 shared publicationsNurmiza Othman
Universiti Tun Hussein Onn Malaysia
9 shared publications- Anis Azwani Muhd Suberi
Univ. Tun Hussein Onn Malaysia (Malaysia)
8 shared publications - Nik Farhan Nik Fuad
Hospital Sultanah Nora Ismail, 86400, Batu Pahat, Malaysia
8 shared publications Razali Tomari
8 shared publications
Latest Publications
- Open Access
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 105564-105578
FDE-RCF: A Navel Orange Defect Edge Detection Algorithm Based on Feature Depth Enhancement
A new edge detection method is proposed for the inspection of navel orange surface defects, enabling precise defect localization, classification type, and size estimation. This study facilitates accurate and efficient grading and sorting, thereby ensuring product quality and extending storage life. To overcome the limitations of existing edge detection methods in handling small, blurred, and color-similar defects, a novel Feature Depth-Enhanced Edge Detection Model (FDE-RCF) is introduced. This model enhances the Richer Convolutional Features (RCF) network by removing its final pooling layers to preserve fine-grained details and integrating three key modules: (1) Dilated Convolution for improved global context, (2) Efficient Channel Attention (ECA) module to selectively focus on defect-relevant features, and (3) Scale Enhancement Module (SEM) for robust edge detection across varying object sizes. A residual fusion structure is also introduced to better capture intricate edge patterns. Experimental results demonstrate that FDE-RCF outperforms conventional models. On navel orange defect datasets, it achieves higher ODS (83.04%), OIS (84.97%), and AP (86.64%), with improvements of 2.32%, 2.44%, and 2.48% respectively, over the baseline RCF. On the standard BSDS500 benchmark, it achieves additional ODS and OIS by 1.81% and 1.78%, while maintaining real-time processing speeds at 28 FPS. The proposed FDE-RCF model generates coherent and continuous edge representations and accurately capture subtle and small-scale defects, highlighting its suitability for integration in automated fruit grading and visual quality inspection systems.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 105564-105578
Open AccessFDE-RCF: A Navel Orange Defect Edge Detection Algorithm Based on Feature Depth Enhancement
A new edge detection method is proposed for the inspection of navel orange surface defects, enabling precise defect localization, classification type, and size estimation. This study facilitates accurate and efficient grading and sorting, thereby ensuring product quality and extending storage life. To overcome the limitations of existing edge detection methods in handling small, blurred, and color-similar defects, a novel Feature Depth-Enhanced Edge Detection Model (FDE-RCF) is introduced. This model enhances the Richer Convolutional Features (RCF) network by removing its final pooling layers to preserve fine-grained details and integrating three key modules: (1) Dilated Convolution for improved global context, (2) Efficient Channel Attention (ECA) module to selectively focus on defect-relevant features, and (3) Scale Enhancement Module (SEM) for robust edge detection across varying object sizes. A residual fusion structure is also introduced to better capture intricate edge patterns. Experimental results demonstrate that FDE-RCF outperforms conventional models. On navel orange defect datasets, it achieves higher ODS (83.04%), OIS (84.97%), and AP (86.64%), with improvements of 2.32%, 2.44%, and 2.48% respectively, over the baseline RCF. On the standard BSDS500 benchmark, it achieves additional ODS and OIS by 1.81% and 1.78%, while maintaining real-time processing speeds at 28 FPS. The proposed FDE-RCF model generates coherent and continuous edge representations and accurately capture subtle and small-scale defects, highlighting its suitability for integration in automated fruit grading and visual quality inspection systems.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2564 (1)
Development of hand gesture controlled robotic arm for hemiplegia patients
Hand gesture-controlled robotic arm is designed to improve the motor function of hemiplegic patients. In this paper, the Leap Motion sensor is the device utilized to collect data for hand gesture recognition. Therapists suggested a combination of wrist revolving rehabilitation exercises that can also be recognized by the Leap Motion sensor, which are: radial-ulnar deviation, flexion-extension, and grasping-releasing of the palm. This study focuses on the EMU HS4 3-DOF robotic arm usage to enable the robot in imitating the hemiplegic patient hand gesture movements. The Leap Motion sensor detects the patient’s functioning hand over the USB bus and sends data to the Leap Motion service on the host PC. Information is processed and sent to a running Leap-enabled application, Processing. Received data undergoes algorithm in Processing, and data is sent to Arduino IDE to move the robot motors as the output according to the hand input given. Normalization of hand, motor, and robot angle positions is crucial in standardizing the collected data. Three test subjects with healthy hands and of different gender and age commit the experiment to validate the system. The experimental results yield three training sessions with three sets of trials for each training. The average Leap Motion sensor and robot position output readings for the three training are recorded and analyzed. As a result, the robot gripper action obeys the desired grab strength by 100%. The yaw and pitch deviations show an RMSE of 3.31 degrees and 3.98 degrees respectively. This system has many potentials for future development and advancement, such as a 6-DOF robot arm implementation that can cater to the pronation and supination movements of the wrist. Also, hemiplegia patients should test on the system to contribute better feedback data and advise on improving the training sessions.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2564 (1)
Open AccessDevelopment of hand gesture controlled robotic arm for hemiplegia patients
Hand gesture-controlled robotic arm is designed to improve the motor function of hemiplegic patients. In this paper, the Leap Motion sensor is the device utilized to collect data for hand gesture recognition. Therapists suggested a combination of wrist revolving rehabilitation exercises that can also be recognized by the Leap Motion sensor, which are: radial-ulnar deviation, flexion-extension, and grasping-releasing of the palm. This study focuses on the EMU HS4 3-DOF robotic arm usage to enable the robot in imitating the hemiplegic patient hand gesture movements. The Leap Motion sensor detects the patient’s functioning hand over the USB bus and sends data to the Leap Motion service on the host PC. Information is processed and sent to a running Leap-enabled application, Processing. Received data undergoes algorithm in Processing, and data is sent to Arduino IDE to move the robot motors as the output according to the hand input given. Normalization of hand, motor, and robot angle positions is crucial in standardizing the collected data. Three test subjects with healthy hands and of different gender and age commit the experiment to validate the system. The experimental results yield three training sessions with three sets of trials for each training. The average Leap Motion sensor and robot position output readings for the three training are recorded and analyzed. As a result, the robot gripper action obeys the desired grab strength by 100%. The yaw and pitch deviations show an RMSE of 3.31 degrees and 3.98 degrees respectively. This system has many potentials for future development and advancement, such as a 6-DOF robot arm implementation that can cater to the pronation and supination movements of the wrist. Also, hemiplegia patients should test on the system to contribute better feedback data and advise on improving the training sessions.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2564 (1)
Result and analysis of automated rubber tapping mechanism
The extraction of rubber trees is considered a highly skilled task, and because of that, many countries nowadays are short of labour. The rubber production will get affected if the labour is lack tapping training. As a result of this study, a new automated tapping mechanism is proposed. The mechanism consists of Arduino Uno, stepper motors, motor drivers, tapping knives, linear guides, and infrared sensors. The mechanism may be connected to the rubber tree and used to regulate and monitor the tapping operation. This session will test the mechanism to cut three different surfaces: air, dry foam, and natural rubber tree. The test is focused on the distance of the cutting line, the time taken to make one cutting line, the cutting speed, and the cutting depth. The testing findings proved the efficacy of the proposed device, with accurate diagonal cuts of 30 degrees.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2564 (1)
Open AccessResult and analysis of automated rubber tapping mechanism
The extraction of rubber trees is considered a highly skilled task, and because of that, many countries nowadays are short of labour. The rubber production will get affected if the labour is lack tapping training. As a result of this study, a new automated tapping mechanism is proposed. The mechanism consists of Arduino Uno, stepper motors, motor drivers, tapping knives, linear guides, and infrared sensors. The mechanism may be connected to the rubber tree and used to regulate and monitor the tapping operation. This session will test the mechanism to cut three different surfaces: air, dry foam, and natural rubber tree. The test is focused on the distance of the cutting line, the time taken to make one cutting line, the cutting speed, and the cutting depth. The testing findings proved the efficacy of the proposed device, with accurate diagonal cuts of 30 degrees.
- 8 July 2020
- Published by Springer Nature
- p. 671-682
Evaluation of Leap Motion Controller Usability in Development of Hand Gesture Recognition for Hemiplegia Patients
- 8 July 2020
- Published by Springer Nature
- p. 671-682
Evaluation of Leap Motion Controller Usability in Development of Hand Gesture Recognition for Hemiplegia Patients
- 8 July 2020
- Published by Springer Nature
- p. 819-829
Improvement of Magnetic Field Induction for MPI Application Using Maxwell Coils Paired-Sub-coils System Arrangement
- 8 July 2020
- Published by Springer Nature
- p. 819-829
Improvement of Magnetic Field Induction for MPI Application Using Maxwell Coils Paired-Sub-coils System Arrangement
- Open Access
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (3) , 1180-1187
Development of a 3D bio-printer using CoreXY mechanism and syringe-based extrusion
3D Bio-printer is said to have potential in the applications of medical studies and tissue engineering. A 3D Bio-printer could be used to print the artificial organs for organs transplant and cell tissue culture for generating new cell tissue. It could help in future medical and biological research. This paper presents the development process, i.e. working principle of Fused Deposition Modelling (FDM), mechanical, electrical and related applied software, of a 3D Bio-printer using syringe-based extruder and Core XY mechanism. Up to date, FDM is a popular technique because it is easily implemented, precise and accurate. The printed product revealed high repeativity, where (sample mean, sample standard deviation) is ( mm. The procedure could help future customized 3D Bio-printer.
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (3) , 1180-1187
Open AccessDevelopment of a 3D bio-printer using CoreXY mechanism and syringe-based extrusion
3D Bio-printer is said to have potential in the applications of medical studies and tissue engineering. A 3D Bio-printer could be used to print the artificial organs for organs transplant and cell tissue culture for generating new cell tissue. It could help in future medical and biological research. This paper presents the development process, i.e. working principle of Fused Deposition Modelling (FDM), mechanical, electrical and related applied software, of a 3D Bio-printer using syringe-based extruder and Core XY mechanism. Up to date, FDM is a popular technique because it is easily implemented, precise and accurate. The printed product revealed high repeativity, where (sample mean, sample standard deviation) is ( mm. The procedure could help future customized 3D Bio-printer.
- 1 April 2020
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 9 (2) , 611–618
Investigation of white blood cell biomaker model for acute lymphoblastic leukemia detection based on convolutional neural network
Acute Lymphoblastic Leukemia (ALL) is a disease that is defined by uncontrollable growth of malignant and immature White Blood Cells (WBCs) which is called lymphoblast. Traditionally, lymphoblast analysis is done manually and highly dependent on the pathologist’s skill and experience which sometimes yields inaccurate result. For that reason, in this project an algorithm to automatically detect WBC and subsequently examine ALL disease using Convolutional Neural Network (CNN) is proposed. Several pretrained CNN models which are VGG, GoogleNet and Alexnet were analaysed to compare its performance for differentiating lymphoblast and non-lymphoblast cells from IDB database. The tuning is done by experimenting the convolution layer, pooling layer and fully connected layer. Technically, 70% of the images are used for training and another 30% for testing. From the experiments, it is found that the best pretrained models are VGG and GoogleNet compared to AlexNet by achieving 100% accuracy for training. As for testing, VGG obtained the highest performance which is 99.13% accuracy. Apart from that, VGG also proven to have better result based on the training graph which is more stable and contains less error compared to the other two models.
- 1 April 2020
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 9 (2) , 611–618
Investigation of white blood cell biomaker model for acute lymphoblastic leukemia detection based on convolutional neural network
Acute Lymphoblastic Leukemia (ALL) is a disease that is defined by uncontrollable growth of malignant and immature White Blood Cells (WBCs) which is called lymphoblast. Traditionally, lymphoblast analysis is done manually and highly dependent on the pathologist’s skill and experience which sometimes yields inaccurate result. For that reason, in this project an algorithm to automatically detect WBC and subsequently examine ALL disease using Convolutional Neural Network (CNN) is proposed. Several pretrained CNN models which are VGG, GoogleNet and Alexnet were analaysed to compare its performance for differentiating lymphoblast and non-lymphoblast cells from IDB database. The tuning is done by experimenting the convolution layer, pooling layer and fully connected layer. Technically, 70% of the images are used for training and another 30% for testing. From the experiments, it is found that the best pretrained models are VGG and GoogleNet compared to AlexNet by achieving 100% accuracy for training. As for testing, VGG obtained the highest performance which is 99.13% accuracy. Apart from that, VGG also proven to have better result based on the training graph which is more stable and contains less error compared to the other two models.
- Open Access
- 1 April 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (1) , 318-325
Retina blood vessel extraction based on kirsch’s template method
Analysis on the retina blood vessels from fundus images have been widely used in the medical community to detect the disorder condition in the blood vessels. An automated tracing of retina blood vessel can help to provide valuable computer-assisted diagnosis for the ophthalmic disorders. Thus, it helps to reduce the time for the ophthalmologist to analyses and diagnose the result of the fundus image of patient. The purpose of this research is to build an algorithm to trace the retina blood vessels. The method to be used in this research consist of two parts which are the pre-processing part and the feature extraction by using the Kirsch’s template. Combining the pre-processing at the early stage and feature extraction at the next stage is applied to extract the edges of the blood vessels. The proposed algorithm was verified by using two online databases, DRIVE and HRF to validate the performance measures. Hence, proposed method is capable to extract the retina blood vessel and give the accuracy of 0.7917, the sensitivity of 0.9077 and the specificity of 0.7215. In conclusion, the extraction of the blood vessels is highly recommended as the early screening stage for the eye diseases beneficially.
- 1 April 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (1) , 318-325
Open AccessRetina blood vessel extraction based on kirsch’s template method
Analysis on the retina blood vessels from fundus images have been widely used in the medical community to detect the disorder condition in the blood vessels. An automated tracing of retina blood vessel can help to provide valuable computer-assisted diagnosis for the ophthalmic disorders. Thus, it helps to reduce the time for the ophthalmologist to analyses and diagnose the result of the fundus image of patient. The purpose of this research is to build an algorithm to trace the retina blood vessels. The method to be used in this research consist of two parts which are the pre-processing part and the feature extraction by using the Kirsch’s template. Combining the pre-processing at the early stage and feature extraction at the next stage is applied to extract the edges of the blood vessels. The proposed algorithm was verified by using two online databases, DRIVE and HRF to validate the performance measures. Hence, proposed method is capable to extract the retina blood vessel and give the accuracy of 0.7917, the sensitivity of 0.9077 and the specificity of 0.7215. In conclusion, the extraction of the blood vessels is highly recommended as the early screening stage for the eye diseases beneficially.
- Open Access
- 1 March 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1502 (1)
Lymphoblast cell morphology identification to detect Acute Lymphoblastic Leukemia (ALL) using various color segmentation
Acute Lymphoblastic Leukemia (ALL) is a disease that is defined by the uncontrollable growth of abnormal cell of lymphocyte, which is called lymphoblast. ALL patients cannot be left untreated as it can be fatal, and hence, early detection is very crucial for proper treatment suggestion. Conventionally, ALL analysis is manually done, which is time-consuming and highly dependent on the pathologist’s skills. Furthermore, it will be hard to pathologist as the number of sample increases, and also there are other cells inside the blood smear image, which will create confusion to them. Haematology counter is great to assist the process, but unfortunately, the cost is unbearable for some countries. For that reason, in this project, a computer-aided ALL detection with fast response is proposed. The system consists of five main modules which are image acquisition, pre-processing, segmentation, feature extraction and classification. For the process flow, firstly the color space correction based on l*a*b* color space is applied to standardize the color of the input image. Next, WBC segmentation is employed to locate the WBC region and consequently divided it into two parts which are the nucleus and cytoplasm based on a combination of color space analysis and Otsu thresholding. However, the segmented image contains noises and hence, is eliminated by using a combination of morphological filter and Connected Component Labelling (CCL). Then, the feature extraction process is made to study the nature of each individual cell using features derive from color, texture and geometrical properties. Lastly, lymphoblast classification is incurred to categorized the lymphoblast and the non-lymphoblast cell by employing Support Vector Machine (SVM) with a linear kernel function. As mentioned before, WBC segmentation is divided into two parts, and nucleus detection accuracy is higher than cytoplasm detection accuracy, which is 98.87% and 74.12% respectively. The presence of color space correction is analyzed, and the result is better with 96.92% accuracy for the presence of color space correction compared to 93.55% accuracy for without color space correction result. Classification performance is able to achieve 98.72% of accuracy.
- 1 March 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1502 (1)
Open AccessLymphoblast cell morphology identification to detect Acute Lymphoblastic Leukemia (ALL) using various color segmentation
Acute Lymphoblastic Leukemia (ALL) is a disease that is defined by the uncontrollable growth of abnormal cell of lymphocyte, which is called lymphoblast. ALL patients cannot be left untreated as it can be fatal, and hence, early detection is very crucial for proper treatment suggestion. Conventionally, ALL analysis is manually done, which is time-consuming and highly dependent on the pathologist’s skills. Furthermore, it will be hard to pathologist as the number of sample increases, and also there are other cells inside the blood smear image, which will create confusion to them. Haematology counter is great to assist the process, but unfortunately, the cost is unbearable for some countries. For that reason, in this project, a computer-aided ALL detection with fast response is proposed. The system consists of five main modules which are image acquisition, pre-processing, segmentation, feature extraction and classification. For the process flow, firstly the color space correction based on l*a*b* color space is applied to standardize the color of the input image. Next, WBC segmentation is employed to locate the WBC region and consequently divided it into two parts which are the nucleus and cytoplasm based on a combination of color space analysis and Otsu thresholding. However, the segmented image contains noises and hence, is eliminated by using a combination of morphological filter and Connected Component Labelling (CCL). Then, the feature extraction process is made to study the nature of each individual cell using features derive from color, texture and geometrical properties. Lastly, lymphoblast classification is incurred to categorized the lymphoblast and the non-lymphoblast cell by employing Support Vector Machine (SVM) with a linear kernel function. As mentioned before, WBC segmentation is divided into two parts, and nucleus detection accuracy is higher than cytoplasm detection accuracy, which is 98.87% and 74.12% respectively. The presence of color space correction is analyzed, and the result is better with 96.92% accuracy for the presence of color space correction compared to 93.55% accuracy for without color space correction result. Classification performance is able to achieve 98.72% of accuracy.