Ali Murteza Altıngün
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ali Murteza Altıngün has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Emrah Kalemci
Faculty of Engineering and Natural Sciences Sabancı University Orhanlı-Tuzla 34956 İstanbul Turkey
3 shared publications A. Kanj
Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
2 shared publications- Efe Oztaban
Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Turkey
2 shared publications F. Carrel
Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
2 shared publicationsG. Amoyal
Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
2 shared publicationsJ. Schuler
Université de Strasbourg, CNRS, IPHC UMR 7178, F-67000 Strasbourg, France
2 shared publications
Latest Publications
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , E02001
Erratum: Development of a transportable neutron imager for localization of radioactive sources
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , E02001
Erratum: Development of a transportable neutron imager for localization of radioactive sources
- Open Access
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06024
Integration concept of the CBM Micro Vertex Detector
The Micro Vertex Detector (MVD) is the most upstream detector of the fixed-target Compressed Baryonic Matter Experiment (CBM) at the future Facility for Antiproton and Ion Research (FAIR). It enables high-precision low-momentum tracking in direct proximity of the target. Reaching the stringent requirements for the MVD, a material budget of 0.3–0.5% X 0 per layer, operating the dedicated CMOS MAPS ('MIMOSIS') in the target vacuum, the strong magnetic dipole field, and a harsh radiation environment (5 Mrad, 7×1013 n eq/cm2 per CBM year), poses an unprecedented integration challenge. In this paper, the integration concept of the detector will be outlined, elaborating on the selection and preparation of materials, assembly procedures, and quality assessment steps in the ongoing preparation of pre-series production and detector commissioning in 2028.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06024
Open AccessIntegration concept of the CBM Micro Vertex Detector
The Micro Vertex Detector (MVD) is the most upstream detector of the fixed-target Compressed Baryonic Matter Experiment (CBM) at the future Facility for Antiproton and Ion Research (FAIR). It enables high-precision low-momentum tracking in direct proximity of the target. Reaching the stringent requirements for the MVD, a material budget of 0.3–0.5% X 0 per layer, operating the dedicated CMOS MAPS ('MIMOSIS') in the target vacuum, the strong magnetic dipole field, and a harsh radiation environment (5 Mrad, 7×1013 n eq/cm2 per CBM year), poses an unprecedented integration challenge. In this paper, the integration concept of the detector will be outlined, elaborating on the selection and preparation of materials, assembly procedures, and quality assessment steps in the ongoing preparation of pre-series production and detector commissioning in 2028.
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , C01036
Development of a transportable neutron imager for localization of radioactive sources
Locating radioactive hot spots presents a significant challenge for the nuclear industry and security applications, such as waste management, decommissioning, radiation protection, and the management of nuclear accidents. The detection of fast-neutron emissions offers an alternative technique to gamma imaging for verifying the location of radioactive materials, particularly in cases where gamma imagers face challenges in detection. In this study, we present the performance of a prototype gamma-neutron imaging system based on a custom-fabricated plastic scintillator, designed to effectively discriminate between signals from gamma radiation, fast neutrons, and thermal neutrons. We conducted Geant4 simulations to investigate neutron interactions within the plastic scintillator and compared the simulation results with experimental data. Additionally, we performed experiments on the prototype using a proton beam at the CYRCé facility at IPHC, utilizing a CMOS Monolithic Active Pixel Sensor (MAPS) called MIMOSIS to analyze the beam profile. Through these efforts, we examined neutron interactions with our scintillator, validated the prototype's imaging capabilities under proton beam exposure, and conducted a calibration study of its energy response.
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , C01036
Development of a transportable neutron imager for localization of radioactive sources
Locating radioactive hot spots presents a significant challenge for the nuclear industry and security applications, such as waste management, decommissioning, radiation protection, and the management of nuclear accidents. The detection of fast-neutron emissions offers an alternative technique to gamma imaging for verifying the location of radioactive materials, particularly in cases where gamma imagers face challenges in detection. In this study, we present the performance of a prototype gamma-neutron imaging system based on a custom-fabricated plastic scintillator, designed to effectively discriminate between signals from gamma radiation, fast neutrons, and thermal neutrons. We conducted Geant4 simulations to investigate neutron interactions within the plastic scintillator and compared the simulation results with experimental data. Additionally, we performed experiments on the prototype using a proton beam at the CYRCé facility at IPHC, utilizing a CMOS Monolithic Active Pixel Sensor (MAPS) called MIMOSIS to analyze the beam profile. Through these efforts, we examined neutron interactions with our scintillator, validated the prototype's imaging capabilities under proton beam exposure, and conducted a calibration study of its energy response.
- 8 March 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (1) , 99-116
The Improved X-ray Detector (iXRD) on Sharjah-Sat-1, design principles, tests and ground calibration
- 8 March 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (1) , 99-116
The Improved X-ray Detector (iXRD) on Sharjah-Sat-1, design principles, tests and ground calibration
- Open Access
A Simulation Study for the Expected Performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the Orbital Background Radiation
Sharjah-Sat-1 is a 3U cubesat with a CdZnTe based hard X-ray detector, called iXRD (improved X-ray Detector) as a scientific payload with the primary objective of monitoring bright X-ray sources in the galaxy. We investigated the effects of the in-orbit background radiation on the iXRD based on Geant4 simulations. Several background components were included in the simulations such as the cosmic diffuse gamma-rays, galactic cosmic rays (protons and alpha particles), trapped protons and electrons, and albedo radiation arising from the upper layer of the atmosphere. The most dominant component is the albedo photon radiation which contributes at low and high energies alike in the instrument energy range of 20 keV - 200 keV. On the other hand, the cosmic diffuse gamma-ray contribution is the strongest between 20 keV and 60 keV in which most of the astrophysics source flux is expected. The third effective component is the galactic cosmic protons. The radiation due to the trapped particles, the albedo neutrons, and the cosmic alpha particles are negligible when the polar regions and the South Atlantic Anomaly region are excluded in the analysis. The total background count rates are ~0.36 and ~0.85 counts/s for the energy bands of 20 - 60 keV and 20 - 200 keV, respectively. We performed charge transportation simulations to determine the spectral response of the iXRD and used it in sensitivity calculations as well. The simulation framework was validated with experimental studies. The estimated sensitivity of 180 mCrab between the energy band of 20 keV - 100 keV indicates that the iXRD could achieve its scientific goals.
Open AccessA Simulation Study for the Expected Performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the Orbital Background Radiation
Sharjah-Sat-1 is a 3U cubesat with a CdZnTe based hard X-ray detector, called iXRD (improved X-ray Detector) as a scientific payload with the primary objective of monitoring bright X-ray sources in the galaxy. We investigated the effects of the in-orbit background radiation on the iXRD based on Geant4 simulations. Several background components were included in the simulations such as the cosmic diffuse gamma-rays, galactic cosmic rays (protons and alpha particles), trapped protons and electrons, and albedo radiation arising from the upper layer of the atmosphere. The most dominant component is the albedo photon radiation which contributes at low and high energies alike in the instrument energy range of 20 keV - 200 keV. On the other hand, the cosmic diffuse gamma-ray contribution is the strongest between 20 keV and 60 keV in which most of the astrophysics source flux is expected. The third effective component is the galactic cosmic protons. The radiation due to the trapped particles, the albedo neutrons, and the cosmic alpha particles are negligible when the polar regions and the South Atlantic Anomaly region are excluded in the analysis. The total background count rates are ~0.36 and ~0.85 counts/s for the energy bands of 20 - 60 keV and 20 - 200 keV, respectively. We performed charge transportation simulations to determine the spectral response of the iXRD and used it in sensitivity calculations as well. The simulation framework was validated with experimental studies. The estimated sensitivity of 180 mCrab between the energy band of 20 keV - 100 keV indicates that the iXRD could achieve its scientific goals.
- 7 January 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (1) , 117-140
A simulation study for the expected performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the orbital background radiation
- 7 January 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (1) , 117-140
A simulation study for the expected performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the orbital background radiation