Vladimir Syssoev
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vladimir Syssoev has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Orlov
FSUE «RFNC-VNIITF Named after Academ. E.I. Zababakhin», VNIC 900, Istra 143502, Russia
2 shared publications - Dmitry Sukharevsky
FSUE «RFNC-VNIITF Named after Academ. E.I. Zababakhin», VNIC 900, Istra 143502, Russia
2 shared publications - Evgeniy Basov
FSUE «RFNC-VNIITF Named after Academ. E.I. Zababakhin», VNIC 900, Istra 143502, Russia
2 shared publications - Kuznetsov Yu. A.
FSUE «RFNC-VNIITF Named after Academ. E.I. Zababakhin», VNIC 900, Istra 143502, Russia
2 shared publications - Naumova M. Yu.
FSUE «RFNC-VNIITF Named after Academ. E.I. Zababakhin», VNIC 900, Istra 143502, Russia
2 shared publications - Nikolay A. Bogatov
Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
2 shared publications
Latest Publications
- 1 December 2023
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 68 (S2) , S251-S256
Microwave Diagnostics of Electrical Discharges in an Artificial Cloud of Charged Water Drops
The microwave diagnostics of discharges occurring in an artificial cloud of charged water droplets created in an open air simulating the environment of thunderclouds is implemented. An artificial cloud with a droplet size of about 1 µm is opaque in the visible range, so intra-cloud discharges are not available for investigation by traditional methods in the spark discharge physics based on the registration of visible discharge radiation. Microwaves pass through such a cloud without noticeable attenuation, they interact only with the plasma of discharges occurring in the cloud. The probing microwave radiation had a wavelength of 8 mm. The attenuation of microwaves passed through the cloud was measured with temporary resolution of about 10 ns. The temporal characteristics of intracloud discharges were investigated.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 68 (S2) , S251-S256
Microwave Diagnostics of Electrical Discharges in an Artificial Cloud of Charged Water Drops
The microwave diagnostics of discharges occurring in an artificial cloud of charged water droplets created in an open air simulating the environment of thunderclouds is implemented. An artificial cloud with a droplet size of about 1 µm is opaque in the visible range, so intra-cloud discharges are not available for investigation by traditional methods in the spark discharge physics based on the registration of visible discharge radiation. Microwaves pass through such a cloud without noticeable attenuation, they interact only with the plasma of discharges occurring in the cloud. The probing microwave radiation had a wavelength of 8 mm. The attenuation of microwaves passed through the cloud was measured with temporary resolution of about 10 ns. The temporal characteristics of intracloud discharges were investigated.
- Open Access
Amplitude–Temporal and Spectral Characteristics of Pulsed UHF-SHF Radiation of a High-Voltage Streamer Discharge in Air under the Atmospheric Pressure
A special experimental setup with a three-electrode discharge gap was used to study the dynamic characteristics of the ultra-high- and super-high-frequency (UHF-SHF) electromagnetic radiation of a high-voltage discharge having the streamer form with reference to the dynamics of individual streamers at the nanosecond time resolution. We performed synchronous detection of the radiation waveforms using a wideband horn antenna, on the one hand, and high-speed photography of the discharge development in the discharge gap using an ICCD camera, on the other hand. It was found that the high-voltage discharge is a source of radiation in the frequency band up to 10 GHz, which is a series of individual ultrawideband (UWB) bursts having durations of less than 1 ns and leading fronts less than 100 ps long and appears when the streamers moving from the discharge anode (thin wire) meet the discharge cathode (plane). By the order of magnitude, the number of radiation bursts corresponds to the number of streamers that reach the electrode, according to the high-speed photography data. The qualitative data confirmed by simple theoretical estimations show that the sources of UWB radiation pulses are individual streamers at the moment of their contact with the electrode, and the radiation of the streamers can be regarded as transition radiation.
Open AccessAmplitude–Temporal and Spectral Characteristics of Pulsed UHF-SHF Radiation of a High-Voltage Streamer Discharge in Air under the Atmospheric Pressure
A special experimental setup with a three-electrode discharge gap was used to study the dynamic characteristics of the ultra-high- and super-high-frequency (UHF-SHF) electromagnetic radiation of a high-voltage discharge having the streamer form with reference to the dynamics of individual streamers at the nanosecond time resolution. We performed synchronous detection of the radiation waveforms using a wideband horn antenna, on the one hand, and high-speed photography of the discharge development in the discharge gap using an ICCD camera, on the other hand. It was found that the high-voltage discharge is a source of radiation in the frequency band up to 10 GHz, which is a series of individual ultrawideband (UWB) bursts having durations of less than 1 ns and leading fronts less than 100 ps long and appears when the streamers moving from the discharge anode (thin wire) meet the discharge cathode (plane). By the order of magnitude, the number of radiation bursts corresponds to the number of streamers that reach the electrode, according to the high-speed photography data. The qualitative data confirmed by simple theoretical estimations show that the sources of UWB radiation pulses are individual streamers at the moment of their contact with the electrode, and the radiation of the streamers can be regarded as transition radiation.
- 30 September 2022
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 13 (5) , 1380-1384
Streamer Discharge Plasma Generator
A description of the developed nanosecond high-voltage generator of low-temperature plasma based on a volume streamer discharge is given. Plasma is formed in a high-voltage three-electrode gap, one of which is at a floating potential. Plasma is formed when a special switch is triggered, which connects a floating potential electrode, pre-charged with positive streamers, to a grounded electrode. The operation of the generator in a pulse-periodic mode greatly simplifies its application in experimental studies. Its design and electrical circuit are described. The main electrical characteristics and parameters of streamer plasma radiation in the optical and ultraviolet ranges are presented. An example of a specific application of a generator plasma for solving problems of water purification from metal ions (by the example of manganese) using electric discharge technology is given. The use of a low-temperature plasma of a streamer discharge for experimental research in the field of propagation of an ultrahigh-frequency (microwave) signal in an ionized region of the atmosphere (thunderstorm cell) is described.
- 30 September 2022
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 13 (5) , 1380-1384
Streamer Discharge Plasma Generator
A description of the developed nanosecond high-voltage generator of low-temperature plasma based on a volume streamer discharge is given. Plasma is formed in a high-voltage three-electrode gap, one of which is at a floating potential. Plasma is formed when a special switch is triggered, which connects a floating potential electrode, pre-charged with positive streamers, to a grounded electrode. The operation of the generator in a pulse-periodic mode greatly simplifies its application in experimental studies. Its design and electrical circuit are described. The main electrical characteristics and parameters of streamer plasma radiation in the optical and ultraviolet ranges are presented. An example of a specific application of a generator plasma for solving problems of water purification from metal ions (by the example of manganese) using electric discharge technology is given. The use of a low-temperature plasma of a streamer discharge for experimental research in the field of propagation of an ultrahigh-frequency (microwave) signal in an ionized region of the atmosphere (thunderstorm cell) is described.
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Technical Physics
- Vol. 92 (3) , 294
Microwave diagnostics of electrical discharges in an artificial cloud of charged water drops
The microwave diagnostics of discharges occurring in an artificial cloud of charged water droplets created in an open air simulating the environment of thunderclouds is implemented. An artificial cloud with a droplet size of about 1 microns is opaque in the visible range, so intra-cloud discharges are not available for investigation by traditional methods in the spark discharge physics based on the registration of visible discharge radiation. Microwaves pass through such a cloud without noticeable attenuation, they interact only with the plasma of discharges occurring in the cloud. The probing microwave radiation had a wavelength of 8 mm. The attenuation of microwaves passed through the cloud was measured with temporary resolution of about 10 ns. The temporal characteristics of intra-cloud discharges were investigated. Keywords: spark, leader, streamer, electromagnetic wave.
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Technical Physics
- Vol. 92 (3) , 294
Microwave diagnostics of electrical discharges in an artificial cloud of charged water drops
The microwave diagnostics of discharges occurring in an artificial cloud of charged water droplets created in an open air simulating the environment of thunderclouds is implemented. An artificial cloud with a droplet size of about 1 microns is opaque in the visible range, so intra-cloud discharges are not available for investigation by traditional methods in the spark discharge physics based on the registration of visible discharge radiation. Microwaves pass through such a cloud without noticeable attenuation, they interact only with the plasma of discharges occurring in the cloud. The probing microwave radiation had a wavelength of 8 mm. The attenuation of microwaves passed through the cloud was measured with temporary resolution of about 10 ns. The temporal characteristics of intra-cloud discharges were investigated. Keywords: spark, leader, streamer, electromagnetic wave.
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Письма в журнал технической физики
- Vol. 48 (8) , 14
Стенд для исследования радиоизлучения длинной электрической искры
На созданном стенде в лабораторных условиях смоделированы с помощью электрической искры в длинном воздушном промежутке различные фазы развития разряда, характерные для молнии. С помощью специальной радиоаппаратуры исследовано радиоизлучение длинной электрической искры. Получено, что на стадиях развития искрового разряда в длинном промежутке регистрируется радиоизлучение как минимум до частоты 1.4 GHz. Данные по радиоизлучению в этом диапазоне имеют большое практическое значение для таких областей, как радиосвязь (при грозовой активности), радиолокация, грозопеленгация. Ключевые слова: длинная электрическая искра, разряд молнии, радиоизлучение, стримерный разряд, лидерный разряд, радиосвязь.
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Письма в журнал технической физики
- Vol. 48 (8) , 14
Стенд для исследования радиоизлучения длинной электрической искры
На созданном стенде в лабораторных условиях смоделированы с помощью электрической искры в длинном воздушном промежутке различные фазы развития разряда, характерные для молнии. С помощью специальной радиоаппаратуры исследовано радиоизлучение длинной электрической искры. Получено, что на стадиях развития искрового разряда в длинном промежутке регистрируется радиоизлучение как минимум до частоты 1.4 GHz. Данные по радиоизлучению в этом диапазоне имеют большое практическое значение для таких областей, как радиосвязь (при грозовой активности), радиолокация, грозопеленгация. Ключевые слова: длинная электрическая искра, разряд молнии, радиоизлучение, стримерный разряд, лидерный разряд, радиосвязь.
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 92 (3) , 386
Микроволновая диагностика разрядов в искусственном облаке заряженных водяных капель
Микроволновая диагностика разрядов в искусственном облаке заряженных водяных капель
- 1 January 2022
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 92 (3) , 386
Микроволновая диагностика разрядов в искусственном облаке заряженных водяных капель
Микроволновая диагностика разрядов в искусственном облаке заряженных водяных капель
- 13 November 2020
- Published by Publishing House Finance and Credit in National Interests: Priorities and Security
- Vol. 16 (11) , 2036-2059
To Russia's energy security given the impact of electromagnetic pulse of the high-altitude nuclear explosion
Subject. Escalating international tensions make nuclear attacks more possible, such as a high-altitude nuclear explosion, which mainly threatens with the electromagnetic pulse. It can destroy modern electrotechnical equipment, especially if it is fitted with microprocessor equipment. Objectives. The study presents considerations on the resilience of infrastructure systems provided they are exposed to the electromagnetic pulse of a high-altitude nuclear explosion. Methods. The study is based on methods of systematization, analysis and comparison. Results. We suggest writing infrastructure system requirements into all regulatory, legislative and legal documents on the energy security and electromagnetic compatibility in case of the electromagnetic pulse of a nuclear explosion. The issue can possible be solved as professionals gather sufficient theoretical, experimental and practical data. We provide the rationale for using properly upgraded testing facilities owned by the Russian Federal Nuclear Centre of Rosatom, and making a special task-force, which could be deal with ensuring the protection of civil targets. Conclusions and Relevance. We provide the rationale for field tests of electrical facilities of infrastructure systems, including energized ones and having different load. As a result of such field test, it will be possible to determine whether the existing (and future) protective facilities and systems are efficiently used to ensure the resilience of electrotechnical equipment to the electromagnetic impulse of a high-altitude nuclear explosion, deliberate destructive effects of powerful electromagnetic generators, lightning overvoltage.
- 13 November 2020
- Published by Publishing House Finance and Credit in National Interests: Priorities and Security
- Vol. 16 (11) , 2036-2059
To Russia's energy security given the impact of electromagnetic pulse of the high-altitude nuclear explosion
Subject. Escalating international tensions make nuclear attacks more possible, such as a high-altitude nuclear explosion, which mainly threatens with the electromagnetic pulse. It can destroy modern electrotechnical equipment, especially if it is fitted with microprocessor equipment. Objectives. The study presents considerations on the resilience of infrastructure systems provided they are exposed to the electromagnetic pulse of a high-altitude nuclear explosion. Methods. The study is based on methods of systematization, analysis and comparison. Results. We suggest writing infrastructure system requirements into all regulatory, legislative and legal documents on the energy security and electromagnetic compatibility in case of the electromagnetic pulse of a nuclear explosion. The issue can possible be solved as professionals gather sufficient theoretical, experimental and practical data. We provide the rationale for using properly upgraded testing facilities owned by the Russian Federal Nuclear Centre of Rosatom, and making a special task-force, which could be deal with ensuring the protection of civil targets. Conclusions and Relevance. We provide the rationale for field tests of electrical facilities of infrastructure systems, including energized ones and having different load. As a result of such field test, it will be possible to determine whether the existing (and future) protective facilities and systems are efficiently used to ensure the resilience of electrotechnical equipment to the electromagnetic impulse of a high-altitude nuclear explosion, deliberate destructive effects of powerful electromagnetic generators, lightning overvoltage.