Eshwar Jagerdeo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eshwar Jagerdeo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Madeline A. Montgomery
Federal Bureau of Investigation Laboratory, 2501 Investigation Parkway, Quantico, VA 22135, USA
4 shared publicationsJason E. Schaff
Federal Bureau of Investigation Laboratory, Quantico, VA, USA
3 shared publicationsMarc A. LeBeau
Federal Bureau of Investigation Laboratory, 2501 Investigation Parkway, Quantico, VA 22135, USA
3 shared publicationsJeffrey N. Leibowitz
Federal Bureau of Investigation Laboratory Quantico VA 22135 USA
2 shared publicationsMartin Sibum
Spark Holland Inc., Emmen, The Netherlands
2 shared publicationsAmanda Wriston
Federal Bureau of Investigation Laboratory, Quantico, VA, 22135, USA
1 shared publication
Latest Publications
- 4 January 2022
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (9) , e9244
Rapid screening procedures for a variety of complex forensic samples using laser diode thermal desorption (LDTD) coupled to different mass spectrometers
Rationale: The applications shared in this paper demonstrate the wide variety of samples that can be analyzed when Laser Diode Thermal Desorption (LDTD) is interfaced with a high‐resolution mass spectrometer and show the speed at which high quality data can be generated from complex matrices. Methods: Samples are solvent extracted and spotted in a 96‐well plate. In the case of biological fluids, hydrolysis followed by solid‐phase extraction is required. The solvent in the 96‐well plate is evaporated followed by mass spectrometric (MS) analysis with atmospheric pressure chemical ionization. Where applicable, the instrument is operated in data‐dependent mode, with a full‐scan mass spectrum followed by MS/MS spectra of the top 10 ions with a total runtime of 0.4 min. Results: Four applications (MAAQ and Tear Gas, twelve rodenticides, seven explosives, and 40 drugs of abuse) are reported in this paper. MAAQ, tear gas, and rodenticides were identified by full‐scan, followed by MS/MS experiments at levels of 125 μg/L, 125 μg/L, and 500 μg/L, respectively. Explosives were all identified at 102 μg/L by full‐scan experiments. The drugs of abuse were identified by multiple reaction monitoring (MRM) experiments at defined cutoff levels from 2 to 1000 μg/L. Conclusions: Interfacing LDTD with a mass spectrometer allows for rapid screening of a wide range of samples, with either minimal or complex sample preparation. Using a high‐resolution mass spectrometer with the combination to perform full‐scan and MS/MS experiments adds a high level of specificity.
- 4 January 2022
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (9) , e9244
Rapid screening procedures for a variety of complex forensic samples using laser diode thermal desorption (LDTD) coupled to different mass spectrometers
Rationale: The applications shared in this paper demonstrate the wide variety of samples that can be analyzed when Laser Diode Thermal Desorption (LDTD) is interfaced with a high‐resolution mass spectrometer and show the speed at which high quality data can be generated from complex matrices. Methods: Samples are solvent extracted and spotted in a 96‐well plate. In the case of biological fluids, hydrolysis followed by solid‐phase extraction is required. The solvent in the 96‐well plate is evaporated followed by mass spectrometric (MS) analysis with atmospheric pressure chemical ionization. Where applicable, the instrument is operated in data‐dependent mode, with a full‐scan mass spectrum followed by MS/MS spectra of the top 10 ions with a total runtime of 0.4 min. Results: Four applications (MAAQ and Tear Gas, twelve rodenticides, seven explosives, and 40 drugs of abuse) are reported in this paper. MAAQ, tear gas, and rodenticides were identified by full‐scan, followed by MS/MS experiments at levels of 125 μg/L, 125 μg/L, and 500 μg/L, respectively. Explosives were all identified at 102 μg/L by full‐scan experiments. The drugs of abuse were identified by multiple reaction monitoring (MRM) experiments at defined cutoff levels from 2 to 1000 μg/L. Conclusions: Interfacing LDTD with a mass spectrometer allows for rapid screening of a wide range of samples, with either minimal or complex sample preparation. Using a high‐resolution mass spectrometer with the combination to perform full‐scan and MS/MS experiments adds a high level of specificity.
- 6 July 2018
- Published by Springer Nature
- Vol. 1810, 75-87
UPLC-Orbitrap® Screening for over 35 Drugs of Abuse and Metabolites in Biological Fluids in Under 10 min
We present a UPLC®-High Resolution Mass Spectrometric method to simultaneously screen for 19 benzodiazepines, 12 opiates, cocaine and three metabolites, and 3 “Z-drug” hypnotic sedatives in both blood and urine specimens. Sample processing consists of a high-speed, high-temperature enzymatic hydrolysis for urine samples followed by a rapid supported liquid extraction (SLE). The combination of ultrahigh-resolution chromatography with high resolution mass spectrometry allows all analytes to be uniquely detected with a 10 min analytical run. Limits of detection for all target analytes are 3 ng/mL or better, with only 300 μL of specimen used for analysis. The combination of low sample volume with fast processing and analysis makes this method a suitable replacement for immunoassay screening of the targeted drug classes, while providing far superior specificity and better limits of detection than can routinely be obtained by immunoassay.
- 6 July 2018
- Published by Springer Nature
- Vol. 1810, 75-87
UPLC-Orbitrap® Screening for over 35 Drugs of Abuse and Metabolites in Biological Fluids in Under 10 min
We present a UPLC®-High Resolution Mass Spectrometric method to simultaneously screen for 19 benzodiazepines, 12 opiates, cocaine and three metabolites, and 3 “Z-drug” hypnotic sedatives in both blood and urine specimens. Sample processing consists of a high-speed, high-temperature enzymatic hydrolysis for urine samples followed by a rapid supported liquid extraction (SLE). The combination of ultrahigh-resolution chromatography with high resolution mass spectrometry allows all analytes to be uniquely detected with a 10 min analytical run. Limits of detection for all target analytes are 3 ng/mL or better, with only 300 μL of specimen used for analysis. The combination of low sample volume with fast processing and analysis makes this method a suitable replacement for immunoassay screening of the targeted drug classes, while providing far superior specificity and better limits of detection than can routinely be obtained by immunoassay.
- Open Access
- 4 April 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (9) , 782-790
Rapid analysis of forensic‐related samples using two ambient ionization techniques coupled to high‐resolution mass spectrometers
Rationale: This paper highlights the versatility of interfacing two ambient ionization techniques, Laser Diode Thermal Desorption (LDTD) and Atmospheric Solids Analysis Probe (ASAP), to high‐resolution mass spectrometers and demonstrate the method's capability to rapidly generate high‐quality data from multiple sample types with minimal, if any, sample preparation. Methods: For ASAP‐MS analysis of solid and liquid samples, the material was transferred to a capillary surface before being introduced into the mass spectrometer. For LDTD‐MS analysis, samples were solvent extracted, spotted in a 96‐well plate, and the solvent was evaporated before being introduced into the mass spectrometer. All analyses were performed using Atmospheric Pressure Chemical Ionization in positive mode. Results: Seven consumer "Spice" packets were combined and analyzed by both ASAP and LDTD, which identified 11 synthetic cannabinoids/cathinones by full MS and MS/MS experiments. To further show the usefulness of these techniques, black tar heroin was analyzed, which resulted in the identification of heroin and its impurities (monoacetylmorphine, papaverine, and noscapine). These experiments were performed on the LTQ‐Orbitrap to demonstrate the ability to perform both parallel and serial MS and MS n experiments. Conclusions: Interfacing LDTD and ASAP to high‐resolution mass spectrometers allows for expeditious analysis of a wide range of samples, with minimal or no sample preparation. Both allow for rapid full scan, MS/MS, and/or MS n experiments from a single sample introduction. Published in 2017. This article is a U.S. Government work and is in the public domain in the USA.
- 4 April 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (9) , 782-790
Open AccessRapid analysis of forensic‐related samples using two ambient ionization techniques coupled to high‐resolution mass spectrometers
Rationale: This paper highlights the versatility of interfacing two ambient ionization techniques, Laser Diode Thermal Desorption (LDTD) and Atmospheric Solids Analysis Probe (ASAP), to high‐resolution mass spectrometers and demonstrate the method's capability to rapidly generate high‐quality data from multiple sample types with minimal, if any, sample preparation. Methods: For ASAP‐MS analysis of solid and liquid samples, the material was transferred to a capillary surface before being introduced into the mass spectrometer. For LDTD‐MS analysis, samples were solvent extracted, spotted in a 96‐well plate, and the solvent was evaporated before being introduced into the mass spectrometer. All analyses were performed using Atmospheric Pressure Chemical Ionization in positive mode. Results: Seven consumer "Spice" packets were combined and analyzed by both ASAP and LDTD, which identified 11 synthetic cannabinoids/cathinones by full MS and MS/MS experiments. To further show the usefulness of these techniques, black tar heroin was analyzed, which resulted in the identification of heroin and its impurities (monoacetylmorphine, papaverine, and noscapine). These experiments were performed on the LTQ‐Orbitrap to demonstrate the ability to perform both parallel and serial MS and MS n experiments. Conclusions: Interfacing LDTD and ASAP to high‐resolution mass spectrometers allows for expeditious analysis of a wide range of samples, with minimal or no sample preparation. Both allow for rapid full scan, MS/MS, and/or MS n experiments from a single sample introduction. Published in 2017. This article is a U.S. Government work and is in the public domain in the USA.
- 1 August 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1027, 11-18
Rapid screening for drugs of abuse in biological fluids by ultra high performance liquid chromatography/Orbitrap mass spectrometry
- 1 August 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1027, 11-18
Rapid screening for drugs of abuse in biological fluids by ultra high performance liquid chromatography/Orbitrap mass spectrometry
- 11 December 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 29 (2) , 205-212
Rapid analysis of forensic samples using an atmospheric solid analysis probe interfaced to a linear ion trap mass spectrometer
RATIONALE: This paper highlights the simplicity of interfacing an Atmospheric Solid Analysis Probe (ASAP) to a Linear Ion Trap Mass Spectrometer and shows that this technique can be used for the rapid generation of high‐quality data from a range of sample types with minimal or no sample preparation. METHODS: For a solid sample or surface deposit, the process entails rubbing a capillary melting tube a few times on the sample to transfer material to the capillary surface and then introducing it into the source of the mass spectrometer. Similarly, for a liquid sample, a capillary tube is dipped into the sample to just coat the surface or a few microliters may be applied to the tip of a capillary before being analyzed by Atmospheric Pressure Chemical Ionization in both positive and negative mode. RESULTS: A rodenticide containing brodifacoum, black tar heroin and its impurities (morphine, codeine, noscapine, papaverine, and monoacetylmorphine), crack cocaine and 1‐methylaminoanthraquinone dyestuff were successfully analyzed directly without any sample preparation. All compounds were detected using full scan mass spectrometry (MS), followed by confirmation by MS/MS. Preliminary results suggest that this technique could be used for quantitation. CONCLUSIONS: Interfacing the ASAP to an ion trap mass spectrometer allows the ability to perform full scan, MS n experiments, and rapid positive/negative switching from a single sample introduction. Because of these features, this instrument is very useful for rapid, routine analysis and for confirmation with the use of in‐house MS/MS libraries. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
- 11 December 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 29 (2) , 205-212
Rapid analysis of forensic samples using an atmospheric solid analysis probe interfaced to a linear ion trap mass spectrometer
RATIONALE: This paper highlights the simplicity of interfacing an Atmospheric Solid Analysis Probe (ASAP) to a Linear Ion Trap Mass Spectrometer and shows that this technique can be used for the rapid generation of high‐quality data from a range of sample types with minimal or no sample preparation. METHODS: For a solid sample or surface deposit, the process entails rubbing a capillary melting tube a few times on the sample to transfer material to the capillary surface and then introducing it into the source of the mass spectrometer. Similarly, for a liquid sample, a capillary tube is dipped into the sample to just coat the surface or a few microliters may be applied to the tip of a capillary before being analyzed by Atmospheric Pressure Chemical Ionization in both positive and negative mode. RESULTS: A rodenticide containing brodifacoum, black tar heroin and its impurities (morphine, codeine, noscapine, papaverine, and monoacetylmorphine), crack cocaine and 1‐methylaminoanthraquinone dyestuff were successfully analyzed directly without any sample preparation. All compounds were detected using full scan mass spectrometry (MS), followed by confirmation by MS/MS. Preliminary results suggest that this technique could be used for quantitation. CONCLUSIONS: Interfacing the ASAP to an ion trap mass spectrometer allows the ability to perform full scan, MS n experiments, and rapid positive/negative switching from a single sample introduction. Because of these features, this instrument is very useful for rapid, routine analysis and for confirmation with the use of in‐house MS/MS libraries. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
- Open Access
- 28 November 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 39 (2) , 83-88
An Improved Method for the Analysis of GHB in Human Hair by Liquid Chromatography Tandem Mass Spectrometry†
The abuse of gamma-hydroxybutyric acid (GHB) and its suspicion in cases of suspected drug-facilitated sexual assault is of keen interest to forensic toxicology laboratories. This paper reports an extraction, separation and detection procedure for GHB in hair utilizing a combination of liquid–liquid extraction and solid-phase extraction using ethyl acetate and Oasis Max® cartridge, respectively, after the hair sample was digested. Analysis was by LC–MS-MS using a gradient separation on an Acclaim® TrinityTM P1 column performing three multiple-reaction monitoring (MRM) transitions each for GHB and its internal standard. The procedure was validated over a range from 0.4 to 50 ng/mg with estimated limit of detection (LOD) of 0.33 and an administratively set limit of quantitation (LOQ) of 1.2 ng/mg. Twenty hair specimens collected from individuals with no known exposure to GHB were analyzed for matrix interferences and to establish initial background levels of GHB. A wide range of endogenous GHB levels were observed in these samples (from less than the LOQ to 4.4 ng/mg). The results suggest the need for additional studies to better establish the full range of endogenous GHB levels in hair and that extreme caution is required in interpreting GHB findings in hair samples.
- 28 November 2014
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 39 (2) , 83-88
Open AccessAn Improved Method for the Analysis of GHB in Human Hair by Liquid Chromatography Tandem Mass Spectrometry†
The abuse of gamma-hydroxybutyric acid (GHB) and its suspicion in cases of suspected drug-facilitated sexual assault is of keen interest to forensic toxicology laboratories. This paper reports an extraction, separation and detection procedure for GHB in hair utilizing a combination of liquid–liquid extraction and solid-phase extraction using ethyl acetate and Oasis Max® cartridge, respectively, after the hair sample was digested. Analysis was by LC–MS-MS using a gradient separation on an Acclaim® TrinityTM P1 column performing three multiple-reaction monitoring (MRM) transitions each for GHB and its internal standard. The procedure was validated over a range from 0.4 to 50 ng/mg with estimated limit of detection (LOD) of 0.33 and an administratively set limit of quantitation (LOQ) of 1.2 ng/mg. Twenty hair specimens collected from individuals with no known exposure to GHB were analyzed for matrix interferences and to establish initial background levels of GHB. A wide range of endogenous GHB levels were observed in these samples (from less than the LOQ to 4.4 ng/mg). The results suggest the need for additional studies to better establish the full range of endogenous GHB levels in hair and that extreme caution is required in interpreting GHB findings in hair samples.
- 26 June 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (1) , 329-338
A fast method for screening and/or quantitation of tetrahydrocannabinol and metabolites in urine by automated SPE/LC/MS/MS
Marijuana is one of the most commonly used illicit substances. The high usage of this substance results in it being commonly encountered in clinical samples throughout the USA and Europe. Due to its wide availability and use, marijuana is also commonly encountered in forensic toxicology laboratories. The proposed method utilized an automated solid phase extraction (SPE) coupled to liquid chromatography/mass spectrometry (LC/MS). The automated SPE procedure was developed using Hysphere C8-EC sorbent, and the high performance liquid chromatography (HPLC) separation was performed using an Xterra MS C18 column with a total runtime of 10 min. The standard curves linearity generally fell between 6 and 500 ng/mL. The limits of detection ranged from 2 to 4 ng/mL, and the limits of quantitation ranged from 8 to 12 ng/mL. The bias and imprecision were determined using a simple analysis of variance (single factor). The results demonstrate bias as <11% and percent imprecision as <12% for all components at four quality control levels. This method has been in use for over 2 years and has been applied to numerous forensic samples. When compared to other published methods, it exceeds others in its simplicity and speed of analysis. This method takes advantage of robotics and automation for a total analysis time of 10 min, including sample preparation, separation, and detection. Automated solid phase extraction unit coupled to a triple quadrupole mass spectrometer
- 26 June 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (1) , 329-338
A fast method for screening and/or quantitation of tetrahydrocannabinol and metabolites in urine by automated SPE/LC/MS/MS
Marijuana is one of the most commonly used illicit substances. The high usage of this substance results in it being commonly encountered in clinical samples throughout the USA and Europe. Due to its wide availability and use, marijuana is also commonly encountered in forensic toxicology laboratories. The proposed method utilized an automated solid phase extraction (SPE) coupled to liquid chromatography/mass spectrometry (LC/MS). The automated SPE procedure was developed using Hysphere C8-EC sorbent, and the high performance liquid chromatography (HPLC) separation was performed using an Xterra MS C18 column with a total runtime of 10 min. The standard curves linearity generally fell between 6 and 500 ng/mL. The limits of detection ranged from 2 to 4 ng/mL, and the limits of quantitation ranged from 8 to 12 ng/mL. The bias and imprecision were determined using a simple analysis of variance (single factor). The results demonstrate bias as <11% and percent imprecision as <12% for all components at four quality control levels. This method has been in use for over 2 years and has been applied to numerous forensic samples. When compared to other published methods, it exceeds others in its simplicity and speed of analysis. This method takes advantage of robotics and automation for a total analysis time of 10 min, including sample preparation, separation, and detection. Automated solid phase extraction unit coupled to a triple quadrupole mass spectrometer
- 28 July 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (17) , 2697-2705
A semi‐automated solid‐phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole blood
Marijuana is one of the most commonly abused illicit substances in the USA, making cannabinoids important to detect in clinical and forensic toxicology laboratories. Historically, cannabinoids in biological fluids have been derivatized and analyzed by gas chromatography/mass spectrometry (GC/MS). There has been a gradual shift in many laboratories towards liquid chromatography/mass spectrometry (LC/MS) for this analysis due to its improved sensitivity and reduced sample preparation compared with GC/MS procedures. This paper reports a validated method for the analysis of Δ 9 ‐tetrahydrocannabinol (THC) and its two main metabolites, 11‐nor‐9‐carboxy‐Δ 9 ‐tetrahydrocannabinol (THC‐COOH) and 11‐hydroxy‐Δ 9 ‐tetrahydrocannabinol (THC‐OH), in whole blood samples. The method has also been validated for cannabinol (CBD) and cannabidiol (CDN), two cannabinoids that were shown not to interfere with the method. This method has been successfully applied to samples both from living people and from deceased individuals obtained during autopsy. This method utilizes online solid‐phase extraction (SPE) with LC/MS. Pretreatment of samples involves protein precipitation, sample concentration, ultracentrifugation, and reconstitution. The online SPE procedure was developed using Hysphere C8‐EC sorbent. A chromatographic gradient with an Xterra MS C 18 column was used for the separation. Four multiple‐reaction monitoring (MRM) transitions were monitored for each analyte and internal standard. Linearity generally fell between 2 and 200 ng/mL. The limits of detection (LODs) ranged from 0.5 to 3 ng/mL and the limits of quantitation (LOQs) ranged from 2 to 8 ng/mL. The bias and imprecision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and imprecision as <9%, for all components at each quantity control level. Published in 2009 by John Wiley & Sons, Ltd.
- 28 July 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (17) , 2697-2705
A semi‐automated solid‐phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole blood
Marijuana is one of the most commonly abused illicit substances in the USA, making cannabinoids important to detect in clinical and forensic toxicology laboratories. Historically, cannabinoids in biological fluids have been derivatized and analyzed by gas chromatography/mass spectrometry (GC/MS). There has been a gradual shift in many laboratories towards liquid chromatography/mass spectrometry (LC/MS) for this analysis due to its improved sensitivity and reduced sample preparation compared with GC/MS procedures. This paper reports a validated method for the analysis of Δ 9 ‐tetrahydrocannabinol (THC) and its two main metabolites, 11‐nor‐9‐carboxy‐Δ 9 ‐tetrahydrocannabinol (THC‐COOH) and 11‐hydroxy‐Δ 9 ‐tetrahydrocannabinol (THC‐OH), in whole blood samples. The method has also been validated for cannabinol (CBD) and cannabidiol (CDN), two cannabinoids that were shown not to interfere with the method. This method has been successfully applied to samples both from living people and from deceased individuals obtained during autopsy. This method utilizes online solid‐phase extraction (SPE) with LC/MS. Pretreatment of samples involves protein precipitation, sample concentration, ultracentrifugation, and reconstitution. The online SPE procedure was developed using Hysphere C8‐EC sorbent. A chromatographic gradient with an Xterra MS C 18 column was used for the separation. Four multiple‐reaction monitoring (MRM) transitions were monitored for each analyte and internal standard. Linearity generally fell between 2 and 200 ng/mL. The limits of detection (LODs) ranged from 0.5 to 3 ng/mL and the limits of quantitation (LOQs) ranged from 2 to 8 ng/mL. The bias and imprecision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and imprecision as <9%, for all components at each quantity control level. Published in 2009 by John Wiley & Sons, Ltd.
- 15 October 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 874 (1-2) , 15-20
An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood☆
- 15 October 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 874 (1-2) , 15-20
An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood☆
- Open Access
- 1 October 2008
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 32 (8) , 570-576
Rapid Analysis of Cocaine and Metabolites in Urine Using a Completely Automated Solid-Phase Extraction-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method
A rapid, simple, and completely automated method for the analysis of cocaine and its metabolites in urine has been developed. The method utilizes online solid-phase extraction (SPE) with liquid chromatographic separation and tandem mass spectrometric detection (MS-MS). An efficient online SPE procedure was developed using Hysphere™ MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50 × 3.00-mm i.d., 5 µm) column was used for the separation of all compounds. Detection was by positive ion mode electrospray ionization MS-MS. Multiple reaction monitoring (MRM) was used to enhance the selectivity and sensitivity of the method. Two MRM transitions were monitored for each analyte and one transition for each internal standard. Linearity was analyte-dependent but generally ranged from 7 to 1000 ng/mL. The limits of detection for the method ranged from 3 to 23 ng/mL and the limits of quantitation ranged from 7 to 69 ng/mL. Quality control (QC) samples were analyzed for each analyte in triplicate at 50, 200, and 800 ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrated bias as < 5% and % precision as < 9% for all components at each QC level.
- 1 October 2008
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 32 (8) , 570-576
Open AccessRapid Analysis of Cocaine and Metabolites in Urine Using a Completely Automated Solid-Phase Extraction-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method
A rapid, simple, and completely automated method for the analysis of cocaine and its metabolites in urine has been developed. The method utilizes online solid-phase extraction (SPE) with liquid chromatographic separation and tandem mass spectrometric detection (MS-MS). An efficient online SPE procedure was developed using Hysphere™ MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50 × 3.00-mm i.d., 5 µm) column was used for the separation of all compounds. Detection was by positive ion mode electrospray ionization MS-MS. Multiple reaction monitoring (MRM) was used to enhance the selectivity and sensitivity of the method. Two MRM transitions were monitored for each analyte and one transition for each internal standard. Linearity was analyte-dependent but generally ranged from 7 to 1000 ng/mL. The limits of detection for the method ranged from 3 to 23 ng/mL and the limits of quantitation ranged from 7 to 69 ng/mL. Quality control (QC) samples were analyzed for each analyte in triplicate at 50, 200, and 800 ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrated bias as < 5% and % precision as < 9% for all components at each QC level.