WLWentao Liu

Wentao Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wentao Liu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MRI-Based Interstitial Fluid Velocity Analysis for Drug Delivery Efficiency Evaluation in Tumor

    by Fangfei He, Xiaohan Zhou, Junwei Cheng, Peisen Zhang, Jun Zhao, Yan Liang, Yi Hou, Wentao Liu, Dong Han

    There are many flow behaviors in solid tumors, including intravascular, bloodstream, and interstitial convection. Studies have shown that tumor interstitial fluid (TIF) is an important part of tumor microenvironment regulation and affects drug delivery and metabolism between tumor cells. Magnetic resonance imaging (MRI) is suitable for detecting the flow rates of liquids in tissues. Clinical phase contrast PC-MRI technology has been designed to observe the blood flow in large vessels such as arteries and veins; however, it is not sensitive enough to deal with slow flow velocity. Our previously developed vertical plane echo PC-MRI technology, the Velocity Mapping sequence, improved the signal-to-noise ratio (SNR) for measuring slow interstitial fluid rate. In this study, this sequence was used to determine the TIF flow rate in MDA-MB-231 human breast tumor cells used in BALB/c nude male mice. Two different sizes of contrast agents were intravenously injected, and the relationship between their distribution and the TIF flow rate was studied for the first time. Combining the results of clinical scanning showed that small-molecule DTPA-Gd (diethylenetriaminepentaacetic acid-gadolinium) was distributed immediately around the tumor margin after the injection. This distribution was positively correlated to the high flow rate area of the TIF before administration. In contrast, nanoparticles NaGdF4-PEG (polyethylene glycol) entered the tumor and reached their peak at 3 h. Drug distribution was negatively correlated with the high-flow-rate region of the TIF. Investigation of the TIF velocity can help better understand the fluid behavior in tumors and its role in drug delivery.


  • Open Access

    Non-invasive assessment for intratumoural distribution of interstitial fluid flow

    by Jun Zhao, Yupeng Cao, Wentao Liu, Dong Han

    Interstitial fluid plays a vital role in drug delivery and tumour treatment. However, few non-invasive measurement methods are available for measuring low-velocity biological fluid flow. Therefore, this study aimed to develop a novel technology called interstitial flow velocity-MRI. The interstitial flow velocity-MRI sequence consists of a dual inversion recovery preparation and an improved stimulated echo sequence (ISTE) combined with phase-contrast MRI. A homemade flow phantom was used to assess the feasibility and sensitivity of interstitial flow velocity-MRI. In addition, xenografts of female BALB/c mouse models of 4T1 breast cancer administered losartan (40 mg/kg) or saline (n = 6) were subjected to imaging on a 7.0 T scanner to assess the in vivo interstitial fluid flow velocity. The results showed a significant correlation (P < 0.001) between the theoretical velocities and velocities measured using the flow phantom. Interstitial flow velocity-MRI could detect a velocity as low as 10.21 ± 2.65 μm/s with a spatial resolution of 0.313 mm. The losartan group had a lower mean interstitial fluid velocity than the control group (85 ± 16 vs 113 ± 24 μm/s). In addition, compared to the saline treatment, losartan treatment reduced the proportion of collagen fibres by 10% and 12% in the Masson and Sirius red staining groups, respectively. Interstitial flow velocity-MRI has the potential to determine interstitial fluid flow velocity non-invasively and exhibits an intuitive velocity map.


  • Dual-responsive fiber-reinforced hydrogel actuators by direct ion patterning

    by Mingyuan Zhao, Dong Han, Yuan Meng, Jing Liu, Yuting Zhu, Zhongxian Li, Kai Li, Wentao Liu, Zhuo Ao

    Nature inspired deformable heterogeneous smart hydrogels have attracted much attention in many fields such as biomedicine devices and soft actuators. However, normal spatial heterogeneous hydrogel structures can only respond to single factor and take one action as set in fabrication. Herein, we report a pre-stretched metal-liganded shape memory hydrogel with fiber reinforced, P(AAc-co-AAm)/CCNFs-Fe3+ (CCNFs: carboxylated cellulose nanofibers, AAc: acrylic acid, AAm: acrylamide), which can conduct shape deformation by solvent induction and ultraviolet (UV) light. The deformation pattern could be programmed by the deposing of ferroin ions. Also, the pre-stretched shape memory hydrogels could effectively produce cyclic actuation or complex shape actuation by UV light. More importantly, combining the solvent response with the light response enabled complex reversible actuations, such as simulating the bending and unfolding of fingers. The addition of CCNFs significantly enhanced the mechanical properties of the hydrogels. The hydrogels with 3 wt.% CCNFs showed an elongation at break of about 500% and a significant increase in tensile strength of 8.7-fold to 1.55 MPa after coordination with metal ions, which was able to meet the mechanical requirements of the bionic actuated hydrogels. This work demonstrated that combining light-programmed and light-responsive shape-memory hydrogels, complemented by another independent response property, could achieve complex and reversible programmed actuations.


  • High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations

    by Yupeng Cao, Xiaohan Zhou, Xiaoli Liu, Mei Yang, Wentao Liu, Dong Han

    Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin-spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.


  • Open Access

    A robust MRI contrast agent for specific display of the interstitial stream

    by Xiaohan Zhou, Junwei Cheng, Fangfei He, Zhuo Ao, Peisen Zhang, Jing Wang, Qing Li, Weinan Tang, Yiyan Zhou, Yan Liang, et al.

    PAA is modified by DTPA pre-chelation with Gd-based monomers to generate an MRI CA with a high r 1 and nanoscale diameter, introducing PAA-Gd, then applied via interstitial space injection to show interstitial stream. The path to kidneys is depicted.


  • Open Access

    Interstitial Fluid Behavior and Diseases

    by Wen‐Tao Liu, Yu‐Peng Cao, Xiao‐Han Zhou, Dong Han

    Living things comprise a typical hierarchical and porous medium, and their most fundamental logical architectures are interstitial structures encapsulating parenchymal structures. The recent discovery of the efficient transport mechanisms of interstitial streams has provided a new understanding of these complex activities. The substance transport of interstitial streams follows mesoscopic fluid behavior dynamics, which is intimately associated with material transfer in nanoconfined spaces and a unique signal transmission. Accordingly, the evaluation of interstitial stream transport behavior at the mesoscopic scale is essential. In this review, recent advances in physical and chemical properties, the substance transport model, and the characterization methods of interstitial streams at the mesoscopic scale, as well as the relationships between interstitial streams and disease are summarized. Interstitial stream transport can be used as a basis to fully mine hierarchal behavior in images to expand imaging behavior into an omics field. By starting from the perspective of soft matter, a new understanding can be gained of health and disease and quantitative physical markers for research, clinical diagnosis, and treatment can be provided, as well as prognosis evaluation in complex diseases such as cancer and Alzheimer's disease. This will provide a foundation for the development of medicine of soft matter.


  • Open Access

    Intervaginal space injection of a liquid metal can prevent breast cancer invasion and better-sustain concomitant resistance

    by Yupeng Cao, Xiajun Hu, Qiang Zhang, Wenda Hua, Nan Hu, Yifeng Nie, Xue Xu, Yonggang Xu, Chongqing Yang, Xiaohan Zhou, et al.

    CW invasion by the primary tumor was inhibited by ISI of an LM. DCs were activated by the LM to sustain CR.


  • Improved stimulated echo in diffusion magnetic resonance imaging: introducing a π pulse for SNR enhancement

    by Yupeng Cao, Yan Zhang, Yuqing Wang, Wentao Liu, Dong Han

    Purpose Anomalous diffusion in biological tissues can be examined by diffusion MRI for various applications, including tumor diagnosis and measurement of brain fiber pathways. However, the measurement of anomalous diffusion requires high b‐values for the diffusion gradient in MRI, and current MRI methods cannot provide a high SNR. This study aimed to improve on the standard stimulated echo (STE) to enhance the SNR in diffusion MRI with high b‐values. Methods Because of hardware limitations and human safety considerations, prolonging the diffusion time (Δ) is 1 of the few methods available to realize high b‐values. Here, we propose a new echo mechanism for diffusion MRI to enhance SNRs under long Δ. By introducing a π pulse at the midpoint between 2nd and 3rd π/2 pulses of STE, we refocus the magnetic moment vectors in the longitudinal plane before the third π/2 pulse is applied, which preserves the full echo signals. This sequence was compared with STE and spin echo (SE). Nine Δs were tested in a phantom. Multi b‐values with 2 Δs were tested in a mouse liver, brain, and tumor. Results Compared with STE and SE, the proposed improved STE (ISTE) exhibited an improved SNR in the phantom experiment and improved performance in the in vivo experiments. Conclusion By using the proposed echo mechanism in diffusion MRI, we enhanced the SNR of the images, which enables us to investigate diffusion behavior at higher b‐values and further facilitates the development of quantitative diffusion MRI and radiomics.


  • Clinical Features and Molecular Pathogenesis of Asidan/SCA36: A Novel Spinocerebellar Ataxia with Motor Neuron Involvement (P05.049)

    by Yoshio Ikeda, Yasuyuki Ohta, Wentao Liu, Hatasu Kobayashi, Miyuki Okamoto, Kazuhiro Takamatsu, Taisei Ota, Yasuhiro Manabe, Koichi Okamoto, Akio Koizumi, et al.