Manal Fayez Abu Samra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Manal Fayez Abu Samra has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Abdel Rahman
Menia Univ, Fac Med, Dept ENT, Al Minya, Egypt
1 shared publicationAlaa Wagih Fathy
Department of Radiology, Faculty of Medicine, Minia University, Minya, Egypt
1 shared publicationAmany Saber Gerges
Menia Univ, Fac Med, Dept Clin Oncol, Al Minya, Egypt
1 shared publicationEbtesam Ismaiel Hasan
Menia Univ, Fac Med, Dept Prevent Med, Al Minya, Egypt
1 shared publicationHosny Saied A. Ghany
Menia Univ, Fac Med, Dept Diagnost Radiol, Al Minya, Egypt
1 shared publicationHosny Sayed Abd El Ghany
Department of Radiology, Faculty of Medicine, Minia University, Minya, Egypt
1 shared publication
Latest Publications
- Open Access
- 4 January 2022
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 53 (1) , 1-9
Diagnostic accuracy of double inversion recovery (DIR) in detection of cortical gray matter lesions in patients with MS
Background: Conventional imaging techniques have a low sensitivity for detection of cortical and deep grey matter lesions in MS which hinder accurate assessment of the total lesion burden. Aim of this work was to assess the diagnostic accuracy of double inversion recovery (DIR) sequence in the detection of cortical grey matter lesions in MS patients. Results: Forty MS patients were prospectively included in this study. Imaging was performed using Philips Ingenia 1.5 T device. The sensitivity, specificity, PPV, NPV and accuracy of DIR sequence in detection of cortical grey matter lesions were 60%, 100%, 100%, 55.6% and 73.3%, respectively. The sensitivity, specificity, positive and negative predictive values as well as accuracy of Flair sequence were 50%, 100%, 100%, 50% and 66.7%, respectively. The sensitivity, specificity, positive and negative predictive values as well as accuracy of T2 sequence in the detection of cortical grey matter lesions were 22.5%, 100%, 100%, 39.2% and 48.3%, respectively. Conclusions: Detection rate of cortical gray matter lesions was significantly higher on DIR sequence than on T2 and Flair sequences.
- 4 January 2022
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 53 (1) , 1-9
Open AccessDiagnostic accuracy of double inversion recovery (DIR) in detection of cortical gray matter lesions in patients with MS
Background: Conventional imaging techniques have a low sensitivity for detection of cortical and deep grey matter lesions in MS which hinder accurate assessment of the total lesion burden. Aim of this work was to assess the diagnostic accuracy of double inversion recovery (DIR) sequence in the detection of cortical grey matter lesions in MS patients. Results: Forty MS patients were prospectively included in this study. Imaging was performed using Philips Ingenia 1.5 T device. The sensitivity, specificity, PPV, NPV and accuracy of DIR sequence in detection of cortical grey matter lesions were 60%, 100%, 100%, 55.6% and 73.3%, respectively. The sensitivity, specificity, positive and negative predictive values as well as accuracy of Flair sequence were 50%, 100%, 100%, 50% and 66.7%, respectively. The sensitivity, specificity, positive and negative predictive values as well as accuracy of T2 sequence in the detection of cortical grey matter lesions were 22.5%, 100%, 100%, 39.2% and 48.3%, respectively. Conclusions: Detection rate of cortical gray matter lesions was significantly higher on DIR sequence than on T2 and Flair sequences.
- Open Access
- 1 December 2018
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 49 (4) , 1030-1035
Role of DW-MRI and ADC value in monitoring therapy of head and neck squamous cell carcinoma
- 1 December 2018
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 49 (4) , 1030-1035
Open AccessRole of DW-MRI and ADC value in monitoring therapy of head and neck squamous cell carcinoma