Tae Kyoung Ha
Research Subjects
Tae Kyoung Ha has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ji Ho Choi
Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, 170, Jomaru-ro, Bucheon 14584, Republic of Korea
8 shared publications - Ji Eun Moon
Major in Statistics, Graduate School, Chungwoon University, Incheon, Republic of Korea
4 shared publications - Yeji Lee
Department of Psychology, Sungshin Women’s University, 2, Bomun-ro 34da-gil, Seongbuk-gu, Seoul 02844, Republic of Korea
3 shared publications - Seockhoon Chung
Department of Psychiatry, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
2 shared publications - Sooyeon Suh
Department of Psychology, Sungshin Women’s University, Seoul, Korea
2 shared publications - Sungkyoung Shin
Department of Psychology, Sungshin Women’s University, 2, Bomun-ro 34da-gil, Seongbuk-gu, Seoul 02844, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Analysis of Interrater Reliability and Interpretive Discrepancies in Polysomnography Scoring Across Clinical Subgroups
Background: Polysomnography (PSG) is the gold standard for diagnosing sleep disorders. However, the subjectivity of manual scoring can lead to inter-scorer variability, undermining diagnostic accuracy and subsequent clinical decisions. This study aims to quantitatively assess scoring concordance among multiple scorers across various clinical subgroups to identify the factors that contribute to interpretive discrepancies. Methods: We conducted a retrospective analysis of overnight diagnostic PSG data from adult patients at a tertiary university hospital sleep center. Interrater reliability was evaluated by three independent expert scorers for 30 subjects selected through stratified random sampling. The polysomnographic data were independently and blindly scored according to the American Academy of Sleep Medicine criteria, focusing on sleep stages, arousals, respiratory events, and leg movements, all scored in 30 s epochs. Interrater agreement was measured using Fleiss’ κ, along with 95% confidence intervals, and included subgroup analyses by diagnostic category. Results: The analysis included a total of 28,291 epochs from 30 adults across normal, insomnia, obstructive sleep apnea (OSA) [mild–severe], and periodic limb movement (PLM) disorder subgroups. The overall interrater agreement for sleep staging among the three scorers was nearly perfect (Fleiss’ κ = 0.932), with the highest concordance observed in stages W, N2, and R, and excellent agreement in stages N1 and N3. Respiratory events showed particularly high reliability, with near-perfect agreement for apnea (κ = 0.955) and substantial agreement for hypopnea, arousals, and PLMs. Pairwise analyses indicated the highest concordance between scorer 1 and scorer 3, while the agreement between scorer 1 and scorer 2 was lower, particularly for detecting arousals and limb movements. Subgroup analyses showed the highest and most stable agreement in moderate OSA, whereas severe OSA exhibited reduced reliability for sleep staging and arousal scoring, indicating increased scoring complexity with greater sleep fragmentation. Conclusions: Although expert PSG scoring demonstrates high overall reliability, significant variability persists in complex cases like severe OSA. These findings underscore the necessity for structured quality assurance and automated tools to improve diagnostic consistency in clinical practice.
Open AccessAnalysis of Interrater Reliability and Interpretive Discrepancies in Polysomnography Scoring Across Clinical Subgroups
Background: Polysomnography (PSG) is the gold standard for diagnosing sleep disorders. However, the subjectivity of manual scoring can lead to inter-scorer variability, undermining diagnostic accuracy and subsequent clinical decisions. This study aims to quantitatively assess scoring concordance among multiple scorers across various clinical subgroups to identify the factors that contribute to interpretive discrepancies. Methods: We conducted a retrospective analysis of overnight diagnostic PSG data from adult patients at a tertiary university hospital sleep center. Interrater reliability was evaluated by three independent expert scorers for 30 subjects selected through stratified random sampling. The polysomnographic data were independently and blindly scored according to the American Academy of Sleep Medicine criteria, focusing on sleep stages, arousals, respiratory events, and leg movements, all scored in 30 s epochs. Interrater agreement was measured using Fleiss’ κ, along with 95% confidence intervals, and included subgroup analyses by diagnostic category. Results: The analysis included a total of 28,291 epochs from 30 adults across normal, insomnia, obstructive sleep apnea (OSA) [mild–severe], and periodic limb movement (PLM) disorder subgroups. The overall interrater agreement for sleep staging among the three scorers was nearly perfect (Fleiss’ κ = 0.932), with the highest concordance observed in stages W, N2, and R, and excellent agreement in stages N1 and N3. Respiratory events showed particularly high reliability, with near-perfect agreement for apnea (κ = 0.955) and substantial agreement for hypopnea, arousals, and PLMs. Pairwise analyses indicated the highest concordance between scorer 1 and scorer 3, while the agreement between scorer 1 and scorer 2 was lower, particularly for detecting arousals and limb movements. Subgroup analyses showed the highest and most stable agreement in moderate OSA, whereas severe OSA exhibited reduced reliability for sleep staging and arousal scoring, indicating increased scoring complexity with greater sleep fragmentation. Conclusions: Although expert PSG scoring demonstrates high overall reliability, significant variability persists in complex cases like severe OSA. These findings underscore the necessity for structured quality assurance and automated tools to improve diagnostic consistency in clinical practice.
- Open Access
- 3 December 2025
- Published by Elsevier in Jornal de Pediatria
- Vol. 102 (1) , 101479
Respiratory mechanic instability in evaluating the effectiveness of adenotonsillectomy for pediatric obstructive sleep apnea
- 3 December 2025
- Published by Elsevier in Jornal de Pediatria
- Vol. 102 (1) , 101479
Open AccessRespiratory mechanic instability in evaluating the effectiveness of adenotonsillectomy for pediatric obstructive sleep apnea
- Open Access
Association Between Positive Airway Pressure Titration Sleep Data and Therapy Adherence in Patients with Obstructive Sleep Apnea
Background and Objectives: Although numerous studies have explored various predictors of positive airway pressure (PAP) adherence, the potential impact of objective sleep scoring data obtained during PAP titration on adherence has not been thoroughly investigated. The objective of this study was to evaluate the association between objective sleep parameters obtained from PAP titration, including sleep efficiency (SE), wake after sleep onset (WASO), and sleep latency (SL), and short-term PAP adherence in individuals with obstructive sleep apnea (OSA). Materials and Methods: A total of 227 individuals with a confirmed diagnosis of OSA underwent overnight PAP titration and were subsequently divided into adherence and non-adherence groups. Baseline demographic characteristics, clinical data, diagnostic polysomnography results, and PAP titration data were obtained for all subjects. Paired sample t-tests were utilized to assess differences in sleep parameters between diagnostic polysomnography and PAP titration within each group. Binomial logistic regression was used to evaluate the predictive value of changes in SE, WASO, and SL for PAP adherence and to determine optimal cut-off values. A χ2 analysis was conducted to assess the relationship between categorical improvements in SE and WASO and adherence to PAP therapy. Results: Among the study cohort, 176 (77.5%) participants were classified as adherent, while 51 (22.5%) participants were classified as non-adherent. SE during PAP titration (83.3 ± 12.6%) was significantly higher compared to baseline polysomnography (80.9 ± 12.4%, p = 0.020), and WASO was significantly reduced (63.9 ± 58.9 min vs. 77.7 ± 67.2 min, p = 0.016). No significant difference was observed in SL between the two groups. Logistic regression analysis indicated that increased SE (odds ratio [OR]: 1.025, p = 0.039) and decreased WASO (OR: 0.994, p = 0.027) both served as significant predictors of PAP adherence, but the overall predictive ability of these indicators was modest (area under the curve 0.60 for SE; 0.62 for WASO). The optimal thresholds distinguishing adherence were ΔSE ≥ 2.39% and ΔWASO < −1.5 min. Participants who exhibited improvements in SE (χ2 = 5.296, p = 0.021) and WASO (χ2 = 6.877, p = 0.009) demonstrated a significantly higher likelihood of adhering to PAP therapy. Conclusions: The findings demonstrate that objective increases in sleep quality, specifically elevated SE and decreased WASO during initial PAP titration, are significantly associated with short-term PAP adherence among patients with OSA.
Open AccessAssociation Between Positive Airway Pressure Titration Sleep Data and Therapy Adherence in Patients with Obstructive Sleep Apnea
Background and Objectives: Although numerous studies have explored various predictors of positive airway pressure (PAP) adherence, the potential impact of objective sleep scoring data obtained during PAP titration on adherence has not been thoroughly investigated. The objective of this study was to evaluate the association between objective sleep parameters obtained from PAP titration, including sleep efficiency (SE), wake after sleep onset (WASO), and sleep latency (SL), and short-term PAP adherence in individuals with obstructive sleep apnea (OSA). Materials and Methods: A total of 227 individuals with a confirmed diagnosis of OSA underwent overnight PAP titration and were subsequently divided into adherence and non-adherence groups. Baseline demographic characteristics, clinical data, diagnostic polysomnography results, and PAP titration data were obtained for all subjects. Paired sample t-tests were utilized to assess differences in sleep parameters between diagnostic polysomnography and PAP titration within each group. Binomial logistic regression was used to evaluate the predictive value of changes in SE, WASO, and SL for PAP adherence and to determine optimal cut-off values. A χ2 analysis was conducted to assess the relationship between categorical improvements in SE and WASO and adherence to PAP therapy. Results: Among the study cohort, 176 (77.5%) participants were classified as adherent, while 51 (22.5%) participants were classified as non-adherent. SE during PAP titration (83.3 ± 12.6%) was significantly higher compared to baseline polysomnography (80.9 ± 12.4%, p = 0.020), and WASO was significantly reduced (63.9 ± 58.9 min vs. 77.7 ± 67.2 min, p = 0.016). No significant difference was observed in SL between the two groups. Logistic regression analysis indicated that increased SE (odds ratio [OR]: 1.025, p = 0.039) and decreased WASO (OR: 0.994, p = 0.027) both served as significant predictors of PAP adherence, but the overall predictive ability of these indicators was modest (area under the curve 0.60 for SE; 0.62 for WASO). The optimal thresholds distinguishing adherence were ΔSE ≥ 2.39% and ΔWASO < −1.5 min. Participants who exhibited improvements in SE (χ2 = 5.296, p = 0.021) and WASO (χ2 = 6.877, p = 0.009) demonstrated a significantly higher likelihood of adhering to PAP therapy. Conclusions: The findings demonstrate that objective increases in sleep quality, specifically elevated SE and decreased WASO during initial PAP titration, are significantly associated with short-term PAP adherence among patients with OSA.
- Open Access
- 5 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3988
Demographic and Sleep Study Factors Influencing Short-Term Adherence to Positive Airway Pressure Therapy in Obstructive Sleep Apnea
Objective: Positive airway pressure (PAP) therapy effectively treats obstructive sleep apnea (OSA), yet adherence to the therapy presents significant challenges. This study identifies demographic and sleep study factors that influence short-term adherence to PAP therapy among patients with OSA by comparing data from adherent and non-adherent groups. Methods: Patients diagnosed with OSA via polysomnography who commenced PAP therapy after titration were divided into adherent and non-adherent groups. We employed propensity score matching in a 1:1 ratio based on age, gender, and body mass index (BMI), including a total of 150 patients in the analysis. Logistic regression analyses were conducted on all pertinent variables, excluding those with high multicollinearity. Non-significant variables were omitted from the final model, whose performance was evaluated using a receiver operating characteristic (ROC) curve, calculating the area under the curve (AUC). Results: Data from 150 participants (mean age 49.56 ± 14.31 years, 79% males, mean BMI 28.96 ± 5.11) were analyzed. Significant predictors of adherence included smoking status (odds ratio [OR] 0.267; 95% confidence interval [CI], 0.116–0.580; p = 0.001), Epworth sleepiness scale (OR 1.080; 95% CI, 1.004–1.166; p = 0.042), oxygen desaturation index (ODI) during titration (OR 0.906; 95% CI, 0.829–0.975, p = 0.015), and optimal PAP levels (OR 1.240; 95% CI, 1.007–1.119; p = 0.029). The ROC curve analysis indicated an AUC of 0.765, confirming the model’s effectiveness in distinguishing between adherent and non-adherent patients. Conclusions: Adherence is negatively affected by smoking, whereas higher daytime sleepiness, optimal PAP levels, and a lower ODI during titration are associated with better adherence, underscoring the importance of personalized treatment approaches.
- 5 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3988
Open AccessDemographic and Sleep Study Factors Influencing Short-Term Adherence to Positive Airway Pressure Therapy in Obstructive Sleep Apnea
Objective: Positive airway pressure (PAP) therapy effectively treats obstructive sleep apnea (OSA), yet adherence to the therapy presents significant challenges. This study identifies demographic and sleep study factors that influence short-term adherence to PAP therapy among patients with OSA by comparing data from adherent and non-adherent groups. Methods: Patients diagnosed with OSA via polysomnography who commenced PAP therapy after titration were divided into adherent and non-adherent groups. We employed propensity score matching in a 1:1 ratio based on age, gender, and body mass index (BMI), including a total of 150 patients in the analysis. Logistic regression analyses were conducted on all pertinent variables, excluding those with high multicollinearity. Non-significant variables were omitted from the final model, whose performance was evaluated using a receiver operating characteristic (ROC) curve, calculating the area under the curve (AUC). Results: Data from 150 participants (mean age 49.56 ± 14.31 years, 79% males, mean BMI 28.96 ± 5.11) were analyzed. Significant predictors of adherence included smoking status (odds ratio [OR] 0.267; 95% confidence interval [CI], 0.116–0.580; p = 0.001), Epworth sleepiness scale (OR 1.080; 95% CI, 1.004–1.166; p = 0.042), oxygen desaturation index (ODI) during titration (OR 0.906; 95% CI, 0.829–0.975, p = 0.015), and optimal PAP levels (OR 1.240; 95% CI, 1.007–1.119; p = 0.029). The ROC curve analysis indicated an AUC of 0.765, confirming the model’s effectiveness in distinguishing between adherent and non-adherent patients. Conclusions: Adherence is negatively affected by smoking, whereas higher daytime sleepiness, optimal PAP levels, and a lower ODI during titration are associated with better adherence, underscoring the importance of personalized treatment approaches.
- Open Access
- 31 December 2024
- Published by Korean Society of Sleep Medicine in Sleep Medicine Research
- Vol. 15 (4) , 237-241
Association Between Weight Loss and Changes in Optimal Positive Airway Pressure Levels in Patients With Obstructive Sleep Apnea
Background and Objective The relationship between weight loss and changes in optimal positive airway pressure (PAP) levels remains unclear. This study was designed to explore the association between weight loss and alterations in optimal PAP levels required to effectively manage obstructive sleep apnea (OSA).Methods Adult patients with OSA, who had undergone PAP therapy and achieved a significant weight loss of at least 5 kg, were included in the study. Data were retrospectively collected from their medical records, which included clinical information, findings from physical examinations, polysomnography results, and PAP usage data.Results Out of the initial cohort, 20 OSA patients (male:female=18:2), with an average age of 42.2±9.3 years and a body mass index of 34.2±5.1 kg/m2, were included in this analysis. Patients experiencing significant weight loss, from 100.6±15.6 to 86.5±12.9 kg (p<0.001), observed a considerable reduction in their optimal PAP levels from 12.0±1.6 to 9.9±1.2 cm H2O (p<0.001). Linear regression analysis revealed a correlation coefficient (r) of 0.428 with a p-value of 0.0596, where the regression equation was y (cm H2O)=0.820+0.093x (kg).Conclusions This study confirms that significant weight loss in OSA patients may reduce the required optimal PAP level for effective treatment. While this study has advanced our understanding of the impact of weight loss on OSA treatment, further research is needed to solidify these findings.
- 31 December 2024
- Published by Korean Society of Sleep Medicine in Sleep Medicine Research
- Vol. 15 (4) , 237-241
Open AccessAssociation Between Weight Loss and Changes in Optimal Positive Airway Pressure Levels in Patients With Obstructive Sleep Apnea
Background and Objective The relationship between weight loss and changes in optimal positive airway pressure (PAP) levels remains unclear. This study was designed to explore the association between weight loss and alterations in optimal PAP levels required to effectively manage obstructive sleep apnea (OSA).Methods Adult patients with OSA, who had undergone PAP therapy and achieved a significant weight loss of at least 5 kg, were included in the study. Data were retrospectively collected from their medical records, which included clinical information, findings from physical examinations, polysomnography results, and PAP usage data.Results Out of the initial cohort, 20 OSA patients (male:female=18:2), with an average age of 42.2±9.3 years and a body mass index of 34.2±5.1 kg/m2, were included in this analysis. Patients experiencing significant weight loss, from 100.6±15.6 to 86.5±12.9 kg (p<0.001), observed a considerable reduction in their optimal PAP levels from 12.0±1.6 to 9.9±1.2 cm H2O (p<0.001). Linear regression analysis revealed a correlation coefficient (r) of 0.428 with a p-value of 0.0596, where the regression equation was y (cm H2O)=0.820+0.093x (kg).Conclusions This study confirms that significant weight loss in OSA patients may reduce the required optimal PAP level for effective treatment. While this study has advanced our understanding of the impact of weight loss on OSA treatment, further research is needed to solidify these findings.
- 13 September 2023
- Published by Wiley in Journal of Sleep Research
- Vol. 33 (1) , e14039
Efficacy and safety of digital therapeutic application of Sleep Index‐Based Treatment for Insomnia (dSIBT‐I): a pilot study
Summary: The aim of this study was to evaluate the safety and efficacy of digital therapeutic application of Sleep Index‐Based Treatment for Insomnia (dSIBT‐I) and compare them with those of digital application of Cognitive Behavioural Therapy for Insomnia (dCBT‐I). This randomised prospective pilot study was conducted at the Asan Medical Center. A total of 50 patients with insomnia were recruited between December 2022 and January 2023 and randomly allocated to the dSIBT‐I or dCBT‐I group. The study was carried out for one month. The primary outcome was the significant reduction in Insomnia Severity Index score at Week 4 compared to baseline, while the secondary outcome was proportion of participants whose Insomnia Severity Index scores were reduced to F = 1.07, p = 0.382) and proportion of participants whose Insomnia Severity Index scores were reduced to F = 1.80, p = 0.615). However, at Week 2, the dSIBT‐I group showed better results than the dCBT‐I group in terms of both Insomnia Severity Index scores (p = 0.044) and proportion of participants whose Insomnia Severity Index scores were reduced to p = 0.017). No treatment‐emergent adverse events were reported in either group. The dSIBT‐I is a safe and effective therapy for insomnia, with rapid treatment effects.
- 13 September 2023
- Published by Wiley in Journal of Sleep Research
- Vol. 33 (1) , e14039
Efficacy and safety of digital therapeutic application of Sleep Index‐Based Treatment for Insomnia (dSIBT‐I): a pilot study
Summary: The aim of this study was to evaluate the safety and efficacy of digital therapeutic application of Sleep Index‐Based Treatment for Insomnia (dSIBT‐I) and compare them with those of digital application of Cognitive Behavioural Therapy for Insomnia (dCBT‐I). This randomised prospective pilot study was conducted at the Asan Medical Center. A total of 50 patients with insomnia were recruited between December 2022 and January 2023 and randomly allocated to the dSIBT‐I or dCBT‐I group. The study was carried out for one month. The primary outcome was the significant reduction in Insomnia Severity Index score at Week 4 compared to baseline, while the secondary outcome was proportion of participants whose Insomnia Severity Index scores were reduced to F = 1.07, p = 0.382) and proportion of participants whose Insomnia Severity Index scores were reduced to F = 1.80, p = 0.615). However, at Week 2, the dSIBT‐I group showed better results than the dCBT‐I group in terms of both Insomnia Severity Index scores (p = 0.044) and proportion of participants whose Insomnia Severity Index scores were reduced to p = 0.017). No treatment‐emergent adverse events were reported in either group. The dSIBT‐I is a safe and effective therapy for insomnia, with rapid treatment effects.
- Open Access
Validation Study on Automated Sleep Stage Scoring Using a Deep Learning Algorithm
Background and Objectives: Polysomnography is manually scored by sleep experts. However, manual scoring is a time-consuming and labor-intensive task. The goal of this study was to verify the accuracy of automated sleep-stage scoring based on a deep learning algorithm compared to manual sleep-stage scoring. Materials and Methods: A total of 602 polysomnography datasets from subjects (Male:Female = 397:205) aged 19 to 65 years (mean age, 43.8, standard deviation = 12.2) were included in the study. The performance of the proposed model was evaluated based on kappa value and bootstrapped point-estimate of median percent agreement with a 95% bootstrap confidence interval and R = 1000. The proposed model was trained using 482 datasets and validated using 48 datasets. For testing, 72 datasets were selected randomly. Results: The proposed model exhibited good concordance rates with manual scoring for stages W (94%), N1 (83.9%), N2 (89%), N3 (92%), and R (93%). The average kappa value was 0.84. For the bootstrap method, high overall agreement between the automated deep learning algorithm and manual scoring was observed in stages W (98%), N1 (94%), N2 (92%), N3 (99%), and R (98%) and total (96%). Conclusions: Automated sleep-stage scoring using the proposed model may be a reliable method for sleep-stage classification.
Open AccessValidation Study on Automated Sleep Stage Scoring Using a Deep Learning Algorithm
Background and Objectives: Polysomnography is manually scored by sleep experts. However, manual scoring is a time-consuming and labor-intensive task. The goal of this study was to verify the accuracy of automated sleep-stage scoring based on a deep learning algorithm compared to manual sleep-stage scoring. Materials and Methods: A total of 602 polysomnography datasets from subjects (Male:Female = 397:205) aged 19 to 65 years (mean age, 43.8, standard deviation = 12.2) were included in the study. The performance of the proposed model was evaluated based on kappa value and bootstrapped point-estimate of median percent agreement with a 95% bootstrap confidence interval and R = 1000. The proposed model was trained using 482 datasets and validated using 48 datasets. For testing, 72 datasets were selected randomly. Results: The proposed model exhibited good concordance rates with manual scoring for stages W (94%), N1 (83.9%), N2 (89%), N3 (92%), and R (93%). The average kappa value was 0.84. For the bootstrap method, high overall agreement between the automated deep learning algorithm and manual scoring was observed in stages W (98%), N1 (94%), N2 (92%), N3 (99%), and R (98%) and total (96%). Conclusions: Automated sleep-stage scoring using the proposed model may be a reliable method for sleep-stage classification.
- 31 December 2021
- Published by Korean Society of Sleep Medicine in Sleep Medicine Research
- Vol. 12 (2) , 118-124
Validation Study of a Contactless Monitoring Device for Vital Signs During Sleep and Sleep Architecture in Adults With Sleep-Disordered Breathing
Background and Objective Few clinical studies have investigated the accuracy of non-contact monitoring devices for vital signs during sleep and sleep architecture in adults with sleep-disordered breathing (SDB). The purpose of this study was to assess the accuracy of a contactless monitoring device for 1) heart rate, respiratory rate, and body temperature during sleep and 2) sleep architecture in adults with SDB.Methods Thirty-five consecutive adults, who visited a tertiary university hospital due to suspected SDB, underwent a complete physical examination and standard (level 1) polysomnography plus body temperature measurement with a contactless monitoring device (HoneyCube System).Results A total of 30 subjects (mean age = 46.43 ± 12.9 years; male: female = 22: 8) were finally included, and five subjects were excluded due to inadequate data in this study. The intraclass correlation coefficient values of heart rate, respiratory rate, and body temperature measured using the contactless monitoring device were 0.91 (95% confidence interval [CI]: 0.892, 0.928), 0.937 (95% CI: 0.919, 0.954), and 0.918 (95% CI: 0.895, 0.941), respectively. The mean kappa value for sleep architecture was 0.562 (95% CI: 0.529, 0.596).Conclusions The contactless monitoring device showed good (almost perfect) agreement in terms of heart rate, respiratory rate, and body temperature and moderate agreement in sleep architecture with contact measurements. These results suggest that the HoneyCube System is a good candidate device for sleep monitoring at home and in multiple accommodations.
- 31 December 2021
- Published by Korean Society of Sleep Medicine in Sleep Medicine Research
- Vol. 12 (2) , 118-124
Validation Study of a Contactless Monitoring Device for Vital Signs During Sleep and Sleep Architecture in Adults With Sleep-Disordered Breathing
Background and Objective Few clinical studies have investigated the accuracy of non-contact monitoring devices for vital signs during sleep and sleep architecture in adults with sleep-disordered breathing (SDB). The purpose of this study was to assess the accuracy of a contactless monitoring device for 1) heart rate, respiratory rate, and body temperature during sleep and 2) sleep architecture in adults with SDB.Methods Thirty-five consecutive adults, who visited a tertiary university hospital due to suspected SDB, underwent a complete physical examination and standard (level 1) polysomnography plus body temperature measurement with a contactless monitoring device (HoneyCube System).Results A total of 30 subjects (mean age = 46.43 ± 12.9 years; male: female = 22: 8) were finally included, and five subjects were excluded due to inadequate data in this study. The intraclass correlation coefficient values of heart rate, respiratory rate, and body temperature measured using the contactless monitoring device were 0.91 (95% confidence interval [CI]: 0.892, 0.928), 0.937 (95% CI: 0.919, 0.954), and 0.918 (95% CI: 0.895, 0.941), respectively. The mean kappa value for sleep architecture was 0.562 (95% CI: 0.529, 0.596).Conclusions The contactless monitoring device showed good (almost perfect) agreement in terms of heart rate, respiratory rate, and body temperature and moderate agreement in sleep architecture with contact measurements. These results suggest that the HoneyCube System is a good candidate device for sleep monitoring at home and in multiple accommodations.