IVIlona Velzeboer

Ilona Velzeboer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ilona Velzeboer has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reply on RC2

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

    A mobile atmospheric measurement platform combining an open-path ammonia (NH₃) analyzer (HT‑8700E) and a closed-path tunable infrared laser direct absorption spectroscopy (TILDAS) multi-gas system was deployed to enable simultaneous, high-frequency observations of NH₃, methane (CH₄), and carbon monoxide (CO) under real-world conditions. The open-path configuration minimizes inlet-related artefacts and enables fast-response NH₃ measurements. A comprehensive measurement framework is presented, including instrument integration, field calibration and validation using co-located reference measurements, data synchronization, plume identification, background removal, and plume-integrated enhancement analysis. The performance of the platform was evaluated during a 160 km mobile campaign in the Veluwe region of the Netherlands, a Natura 2000 nature reserve surrounded by intensive livestock farming. During the campaign, plumes from 49 individual sources and approximately 630 transient traffic-related events were detected, resolving short-lived concentration enhancements across agricultural, industrial, and traffic-dominated environments. Plume-integrated enhancement ratios (ΣNH₃:ΣCH₄) showed systematic differences among source types, with low ratios for livestock farms (∼0.04 for cattle and goats), intermediate values for industrial sources, and substantially higher ratios for manured fields (>2) and traffic plumes (>4). In addition, NH₃ emission factors derived for traffic increased with driving speed from approximately 0.12 g kg⁻¹ fuel at low speeds to ~0.28 g kg⁻¹ under highway conditions. These results demonstrate that simultaneous mobile measurements of NH₃, CH₄, and CO provide an effective approach for detecting and differentiating emission sources under real-world conditions. The combined observations reveal distinct source signatures and potential gaps in existing emission inventories. Although uncertainties remain due to atmospheric variability, calibration, limited temporal sampling, and overlap in source-specific ratios, the methodology shows strong potential for high-resolution characterization of heterogeneous NH₃ emissions through repeated mobile monitoring campaigns.

  • Open Access

    Reply on RC1

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

    A mobile atmospheric measurement platform combining an open-path ammonia (NH₃) analyzer (HT‑8700E) and a closed-path tunable infrared laser direct absorption spectroscopy (TILDAS) multi-gas system was deployed to enable simultaneous, high-frequency observations of NH₃, methane (CH₄), and carbon monoxide (CO) under real-world conditions. The open-path configuration minimizes inlet-related artefacts and enables fast-response NH₃ measurements. A comprehensive measurement framework is presented, including instrument integration, field calibration and validation using co-located reference measurements, data synchronization, plume identification, background removal, and plume-integrated enhancement analysis. The performance of the platform was evaluated during a 160 km mobile campaign in the Veluwe region of the Netherlands, a Natura 2000 nature reserve surrounded by intensive livestock farming. During the campaign, plumes from 49 individual sources and approximately 630 transient traffic-related events were detected, resolving short-lived concentration enhancements across agricultural, industrial, and traffic-dominated environments. Plume-integrated enhancement ratios (ΣNH₃:ΣCH₄) showed systematic differences among source types, with low ratios for livestock farms (∼0.04 for cattle and goats), intermediate values for industrial sources, and substantially higher ratios for manured fields (>2) and traffic plumes (>4). In addition, NH₃ emission factors derived for traffic increased with driving speed from approximately 0.12 g kg⁻¹ fuel at low speeds to ~0.28 g kg⁻¹ under highway conditions. These results demonstrate that simultaneous mobile measurements of NH₃, CH₄, and CO provide an effective approach for detecting and differentiating emission sources under real-world conditions. The combined observations reveal distinct source signatures and potential gaps in existing emission inventories. Although uncertainties remain due to atmospheric variability, calibration, limited temporal sampling, and overlap in source-specific ratios, the methodology shows strong potential for high-resolution characterization of heterogeneous NH₃ emissions through repeated mobile monitoring campaigns.

  • Open Access

    Comment on egusphere-2026-2838

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

    A mobile atmospheric measurement platform combining an open-path ammonia (NH₃) analyzer (HT‑8700E) and a closed-path tunable infrared laser direct absorption spectroscopy (TILDAS) multi-gas system was deployed to enable simultaneous, high-frequency observations of NH₃, methane (CH₄), and carbon monoxide (CO) under real-world conditions. The open-path configuration minimizes inlet-related artefacts and enables fast-response NH₃ measurements. A comprehensive measurement framework is presented, including instrument integration, field calibration and validation using co-located reference measurements, data synchronization, plume identification, background removal, and plume-integrated enhancement analysis. The performance of the platform was evaluated during a 160 km mobile campaign in the Veluwe region of the Netherlands, a Natura 2000 nature reserve surrounded by intensive livestock farming. During the campaign, plumes from 49 individual sources and approximately 630 transient traffic-related events were detected, resolving short-lived concentration enhancements across agricultural, industrial, and traffic-dominated environments. Plume-integrated enhancement ratios (ΣNH₃:ΣCH₄) showed systematic differences among source types, with low ratios for livestock farms (∼0.04 for cattle and goats), intermediate values for industrial sources, and substantially higher ratios for manured fields (>2) and traffic plumes (>4). In addition, NH₃ emission factors derived for traffic increased with driving speed from approximately 0.12 g kg⁻¹ fuel at low speeds to ~0.28 g kg⁻¹ under highway conditions. These results demonstrate that simultaneous mobile measurements of NH₃, CH₄, and CO provide an effective approach for detecting and differentiating emission sources under real-world conditions. The combined observations reveal distinct source signatures and potential gaps in existing emission inventories. Although uncertainties remain due to atmospheric variability, calibration, limited temporal sampling, and overlap in source-specific ratios, the methodology shows strong potential for high-resolution characterization of heterogeneous NH₃ emissions through repeated mobile monitoring campaigns.

  • Open Access

    Comment on egusphere-2026-2838

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

    A mobile atmospheric measurement platform combining an open-path ammonia (NH₃) analyzer (HT‑8700E) and a closed-path tunable infrared laser direct absorption spectroscopy (TILDAS) multi-gas system was deployed to enable simultaneous, high-frequency observations of NH₃, methane (CH₄), and carbon monoxide (CO) under real-world conditions. The open-path configuration minimizes inlet-related artefacts and enables fast-response NH₃ measurements. A comprehensive measurement framework is presented, including instrument integration, field calibration and validation using co-located reference measurements, data synchronization, plume identification, background removal, and plume-integrated enhancement analysis. The performance of the platform was evaluated during a 160 km mobile campaign in the Veluwe region of the Netherlands, a Natura 2000 nature reserve surrounded by intensive livestock farming. During the campaign, plumes from 49 individual sources and approximately 630 transient traffic-related events were detected, resolving short-lived concentration enhancements across agricultural, industrial, and traffic-dominated environments. Plume-integrated enhancement ratios (ΣNH₃:ΣCH₄) showed systematic differences among source types, with low ratios for livestock farms (∼0.04 for cattle and goats), intermediate values for industrial sources, and substantially higher ratios for manured fields (>2) and traffic plumes (>4). In addition, NH₃ emission factors derived for traffic increased with driving speed from approximately 0.12 g kg⁻¹ fuel at low speeds to ~0.28 g kg⁻¹ under highway conditions. These results demonstrate that simultaneous mobile measurements of NH₃, CH₄, and CO provide an effective approach for detecting and differentiating emission sources under real-world conditions. The combined observations reveal distinct source signatures and potential gaps in existing emission inventories. Although uncertainties remain due to atmospheric variability, calibration, limited temporal sampling, and overlap in source-specific ratios, the methodology shows strong potential for high-resolution characterization of heterogeneous NH₃ emissions through repeated mobile monitoring campaigns.

  • Open Access

    Novel mobile measurements of ammonia and methane: distinguishing agricultural and traffic sources in the Netherlands

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

    A mobile atmospheric measurement platform combining an open-path ammonia (NH₃) analyzer (HT‑8700E) and a closed-path tunable infrared laser direct absorption spectroscopy (TILDAS) multi-gas system was deployed to enable simultaneous, high-frequency observations of NH₃, methane (CH₄), and carbon monoxide (CO) under real-world conditions. The open-path configuration minimizes inlet-related artefacts and enables fast-response NH₃ measurements. A comprehensive measurement framework is presented, including instrument integration, field calibration and validation using co-located reference measurements, data synchronization, plume identification, background removal, and plume-integrated enhancement analysis. The performance of the platform was evaluated during a 160 km mobile campaign in the Veluwe region of the Netherlands, a Natura 2000 nature reserve surrounded by intensive livestock farming. During the campaign, plumes from 49 individual sources and approximately 630 transient traffic-related events were detected, resolving short-lived concentration enhancements across agricultural, industrial, and traffic-dominated environments. Plume-integrated enhancement ratios (ΣNH₃:ΣCH₄) showed systematic differences among source types, with low ratios for livestock farms (∼0.04 for cattle and goats), intermediate values for industrial sources, and substantially higher ratios for manured fields (>2) and traffic plumes (>4). In addition, NH₃ emission factors derived for traffic increased with driving speed from approximately 0.12 g kg⁻¹ fuel at low speeds to ~0.28 g kg⁻¹ under highway conditions. These results demonstrate that simultaneous mobile measurements of NH₃, CH₄, and CO provide an effective approach for detecting and differentiating emission sources under real-world conditions. The combined observations reveal distinct source signatures and potential gaps in existing emission inventories. Although uncertainties remain due to atmospheric variability, calibration, limited temporal sampling, and overlap in source-specific ratios, the methodology shows strong potential for high-resolution characterization of heterogeneous NH₃ emissions through repeated mobile monitoring campaigns.

  • Open Access

    Supplementary material to "Novel mobile measurements of ammonia and methane: distinguishing agricultural and traffic sources in the Netherlands"

    by Jun Zhang, Arjan Hensen, Baye Thera, Pim van Den Bulk, Daniëlle van Dinther, Ilona Velzeboer, Enrico Dammers, Gerrit Jan de Bruin, Paula Bronsveld, Martijn Schaap

  • Open Access

    Verifying and improving methane emission inventory data using atmospheric measurements in the Netherlands (IMEO-VIME-NL)

    by Katharina Heimerl, Guus J.M. Velders, Thomas Röckmann, Hannes Witt, Margreet van Zanten, Hugo Denier van der Gon, Ingrid Super, Sander Houweling, Arjan Hensen, Ilona Velzeboer, et al.

    Methane is an important greenhouse gas that contributes to about 12% to Dutch greenhouse gas emissions. In previous studies, top-down modelling and satellite inversions have indicated that methane emissions in the Netherlands as represented in bottom-up inventories might be underestimated. The IMEO-VIME-NL project aims to make use of the abundant data sets of methane measurements in the Netherlands to compile a national measurement-based methane emission baseline.A compilation of available measurement data shows that not all sectors are covered equally. While sectors like peatlands and wastewater treatment plants were frequently targeted by measurements, other sectors, like biodigesters and domestic combustion, are lacking measurement data. Sometimes data are mainly concentrated on a subsector, e.g. most measurement data for the agriculture sector, the main contributor to Dutch methane emissions, focus on dairy farms. This data set collection is then used for upscaling to national total emissions.An important outcome of the project is a compilation of upscaling methods that could potentially be transferred to other countries. Sensitivity studies are employed to test different data coverages and different activity data when upscaling to national total emissions. For wastewater treatment plant emissions, two different types of activity data are readily available, inhabitants and water usage. Using these activity data for estimating emissions results in similar emission estimates that are higher than the inventory emission. In a similar way, methane emission measurements and available activity data for other sectors are compiled together and upscaled to a measurement-based national methane emission baseline.

  • Open Access

    Quantifying H2 emissions of new and existing infrastructure

    by Ceres Woolley Maisch, Ilona Velzeboer, Pim van Den Bulk, Harmen van Mansom, Arjan Hensen, Thomas Röckmann

    The hydrogen value chain, including the production, distribution, storage and end use of H2, is growing around the world. Although hydrogen is viewed as a sustainable energy carrier, it has an indirect radiative effect. H2 is a leak prone gas, and emissions from leaks/purging/venting across the H2 value chain could lead to increased H2 mole fraction in the atmosphere. Through the reaction of H2 with OH, this would increase mole fractions of CH4, tropospheric ozone and stratospheric water vapour, all of which result in warming. Hence, the GWP20 and GWP100 of H2 are estimated to be around 37 and 12, respectively.Therefore, measurements of emissions of H2 from existing and new hydrogen infrastructure are needed. However, low levels of H2 are difficult to measure and suitable measurement technologies are becoming available only recently. One such technology is the Aerodyne Research TILDAS H2 monitor. This monitor has a high precision (down to 5 parts per billion which is 100 times below ambient), has fast time resolution (5 seconds), and can perform continuous 1 Hz air measurements. The instrument has been found to successfully observe a wide range of mole fraction enhancements of H2 on a mobile platform, and these plumes can be converted to emission rates with dispersion models and/or release of tracers at controlled rate. Emission rates from new and existing infrastructure such as refuelling and refilling stations, pipelines, electrolysers and buses will be presented here.

  • Open Access

    Improving consistency in methane emission quantification from the natural gas distribution systems across measurement devices

    by Judith Tettenborn, Daniel Zavala-Araiza, Daan Stroeken, Hossein Maazallahi, Carina van der Veen, Arjan Hensen, Ilona Velzeboer, Pim van Den Bulk, Felix Vogel, Lawson Gillespie, et al.

    Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to (i) identify leak locations for repair and (ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed, and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted with various devices in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, when different analysers were measuring in the same vehicle and from the same air inlet, the integrated spatial peak area was found to be a more robust metric across different methane gas analyser devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor to uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of five–seven plume transects for effective emission quantification to prioritize repair actions.


  • Open Access

    Reply on RC2

    by Judith Tettenborn, Daniel Zavala-Araiza, Daan Stroeken, Hossein Maazallahi, Carina van der Veen, Arjan Hensen, Ilona Velzeboer, Pim van Den Bulk, Felix Vogel, Lawson Gillespie, et al.

    Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to i) identify leak locations for repair and ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, the integrated spatial peak area was found to be a more robust metric across different methane gas analyzer devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor of uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of 5-7 plume transects for effective emission quantification to prioritize repair actions.